Photovoltaic tracking sensor monitoring the position of the sun in the sky was developed on the basis of GeS:Sb layered crystals. The operating principle of this sensor is based on the phenomenon of photovoltaic effec...Photovoltaic tracking sensor monitoring the position of the sun in the sky was developed on the basis of GeS:Sb layered crystals. The operating principle of this sensor is based on the phenomenon of photovoltaic effect in GeS:Sb crystals;the magnitude and sign of generated photo-emf depend on the position of the light probe relative to the ohmic contacts, deposited on (001) surface of the crystal.展开更多
Hydrogen has been recently attracted much attention with respect to high energy-conversion efficiency and low environmental burden. However, hydrogen gas is dangerous due to an explosive gas and a fast combustion rate...Hydrogen has been recently attracted much attention with respect to high energy-conversion efficiency and low environmental burden. However, hydrogen gas is dangerous due to an explosive gas and a fast combustion rate. Therefore, the development of hydrogen sensor with high accuracy and reliability that can detect hydrogen easily is required. Especially, a flexible hydrogen sensor is useful because it has a high degree of freedom with respect to the shape of location in which the sensor is to be located. A flexible hydrogen sensor—namely, a WO3 thin film formed on a PET film by the sol-gel method using photo irradiation—based on gasochromism of WO3 was developed. By irradiating a thin film, which was prepared by using WO3 precursor solution synthesized by the sol-gel method, with ultraviolet rays, a high-purity WO3 film could be prepared on PET at low temperature. The sensor was structured as a polystyrene (PS) film containing palladium (Pd) laminated on a WO3 film. The WO3 layer was porous, so the PS containing Pd atoms solution penetrated the WO3 layer. WO3 reacted with hydrogen gas and instantly turned blue as the transmittance of the WO3 layer changed. The sensor showed high reactivity even for hydrogen concentration below 4% (1%, 0.5%, 0.25%, and 0.1%), which was the lower limit of hydrogen ignition, and a linear relationship between hydrogen concentration and change in transmittance was found. Moreover, the resistance of the WO3 film significantly and instantaneously changed due to hydrogen-gas exposure, and the hydrogen concentration and resistance change showed a linear relationship. It is therefore possible to quantitatively detect low concentrations of hydrogen by using changes in transmittance and resistance as indices. Since these changes occur selectively under hydrogen at room temperature and normal pressure, they form the basis of a highly sensitive hydrogen sensor. Since the developed sensor is flexible, it has a high degree of freedom with respect to the shape of location in which the sensor is to be展开更多
Photo-Electric Microbe Sensor is a patented biotechnology that detects microbes in aqueous solution by measuring the change in photo-voltage in response to UV light stimulation of a platinum (Pt) disk surface on an el...Photo-Electric Microbe Sensor is a patented biotechnology that detects microbes in aqueous solution by measuring the change in photo-voltage in response to UV light stimulation of a platinum (Pt) disk surface on an electrode before and after immunoprecipitation of microbes. This study aimed to increase the sensitivity of microbe detection by pre-adsorbing recombinant Streptococcal Protein G (PG), to the Pt sensor surface. Streptococcal PG binds the Fc region of mammalian IgG molecules and we investigated the association of PG to Pt and the resulting ability to tether antibodies to the Pt-PG surface. An ELISA protocol was optimized to detect the presence of mouse monoclonal antibodies tethered to Pt immunoaffinity disks, and to determine the recommended blocking solution and reagent concentrations. Our results demonstrate that PG binds to bare Pt, increases IgG affinity to the Pt surface following Superblock Buffer application, and together offers design-options for Pt-based sensor technologies.展开更多
Beginning with the analysis on the principle of photoelectric sunshine duration sensor and combining with the problems occurred in use,various factors affecting the accuracy of observation are discussed. The digital s...Beginning with the analysis on the principle of photoelectric sunshine duration sensor and combining with the problems occurred in use,various factors affecting the accuracy of observation are discussed. The digital sunshine duration sensor solutions are put forward by analysis on the data detection and observation,the corrections on the error factors are discussed,such as directional response characteristic,stray light and temperature characteristic. As a consequence,the precision of the sunshine duration with automatic observation is improved.展开更多
The use of stress-induced changes in a crystal of a monolithic solid-state laser by external force as a way for micro-force detection and measurement is described. In fact, the application of an unknown force on the r...The use of stress-induced changes in a crystal of a monolithic solid-state laser by external force as a way for micro-force detection and measurement is described. In fact, the application of an unknown force on the resonator-amplifier crystal of a solid-state laser leads to a measurable change in the frequency of the beat note associated with the orthogonal polarisation components of the oscillating laser mode. Here we report our first measurements of the sensitivity of a photo-elastic force sensor, realised with a monolithic (4 × 4) mm plano-convex cylindrical crystal, and compare them with the results obtained by other authors for different configurations and dimensions of the laser sensor. The reported results are in a good mutual agreement but show notable discrepancies with theoretical predictions, especially for high sensitivities obtained when the dimensions of the laser sensor are small.展开更多
文摘Photovoltaic tracking sensor monitoring the position of the sun in the sky was developed on the basis of GeS:Sb layered crystals. The operating principle of this sensor is based on the phenomenon of photovoltaic effect in GeS:Sb crystals;the magnitude and sign of generated photo-emf depend on the position of the light probe relative to the ohmic contacts, deposited on (001) surface of the crystal.
文摘Hydrogen has been recently attracted much attention with respect to high energy-conversion efficiency and low environmental burden. However, hydrogen gas is dangerous due to an explosive gas and a fast combustion rate. Therefore, the development of hydrogen sensor with high accuracy and reliability that can detect hydrogen easily is required. Especially, a flexible hydrogen sensor is useful because it has a high degree of freedom with respect to the shape of location in which the sensor is to be located. A flexible hydrogen sensor—namely, a WO3 thin film formed on a PET film by the sol-gel method using photo irradiation—based on gasochromism of WO3 was developed. By irradiating a thin film, which was prepared by using WO3 precursor solution synthesized by the sol-gel method, with ultraviolet rays, a high-purity WO3 film could be prepared on PET at low temperature. The sensor was structured as a polystyrene (PS) film containing palladium (Pd) laminated on a WO3 film. The WO3 layer was porous, so the PS containing Pd atoms solution penetrated the WO3 layer. WO3 reacted with hydrogen gas and instantly turned blue as the transmittance of the WO3 layer changed. The sensor showed high reactivity even for hydrogen concentration below 4% (1%, 0.5%, 0.25%, and 0.1%), which was the lower limit of hydrogen ignition, and a linear relationship between hydrogen concentration and change in transmittance was found. Moreover, the resistance of the WO3 film significantly and instantaneously changed due to hydrogen-gas exposure, and the hydrogen concentration and resistance change showed a linear relationship. It is therefore possible to quantitatively detect low concentrations of hydrogen by using changes in transmittance and resistance as indices. Since these changes occur selectively under hydrogen at room temperature and normal pressure, they form the basis of a highly sensitive hydrogen sensor. Since the developed sensor is flexible, it has a high degree of freedom with respect to the shape of location in which the sensor is to be
文摘基于光电容积脉搏波描记法(Photo Plethysmo Graphy,PPG)的柔性传感器可进行心率(Heart Rate,HR)和血压(Blood Pressure,BP)检测,但是对其检测结果的标定报道甚少.据此,本文提出一种基于模拟血液循环的反射式PPG心率检测和血压标定系统.以蠕动泵来产生脉动流,通过调节其转速的大小来控制模拟血液输送的频率和压力,从而引起弹性乳胶管内模拟血液体积的变化,而改变反射光的信号周期与强度,贴近于人体脉搏测量过程的实际场景.该系统心率检测误差均值为0.27778,95%一致性界限为(-2.59562,3.15117),所测收缩压(Systolic Blood Pressure,SBP)和舒张压(Diastolic Blood Pressure,DBP)的拟合优度分别为0.97185和0.98111.经标定后的柔性PPG传感器对4名志愿者检测的SBP和DBP的平均偏差(Mean Deviation,MD)±标准差(Standard Deviation,SD)均值分别为(1.21±2.16)mmHg和(0.76±2.02)mmHg,均符合且远小于美国医疗仪器促进协会(Association for the Advancement of Medical Instrumentation,AAMI)所制定的衡量血压计精度的标准指标(5±8)mmHg.结果表明,该系统能够准确高效地标定柔性PPG传感器,为实现便携式可穿戴设备的精准血压检测提供标定基础.
文摘Photo-Electric Microbe Sensor is a patented biotechnology that detects microbes in aqueous solution by measuring the change in photo-voltage in response to UV light stimulation of a platinum (Pt) disk surface on an electrode before and after immunoprecipitation of microbes. This study aimed to increase the sensitivity of microbe detection by pre-adsorbing recombinant Streptococcal Protein G (PG), to the Pt sensor surface. Streptococcal PG binds the Fc region of mammalian IgG molecules and we investigated the association of PG to Pt and the resulting ability to tether antibodies to the Pt-PG surface. An ELISA protocol was optimized to detect the presence of mouse monoclonal antibodies tethered to Pt immunoaffinity disks, and to determine the recommended blocking solution and reagent concentrations. Our results demonstrate that PG binds to bare Pt, increases IgG affinity to the Pt surface following Superblock Buffer application, and together offers design-options for Pt-based sensor technologies.
文摘Beginning with the analysis on the principle of photoelectric sunshine duration sensor and combining with the problems occurred in use,various factors affecting the accuracy of observation are discussed. The digital sunshine duration sensor solutions are put forward by analysis on the data detection and observation,the corrections on the error factors are discussed,such as directional response characteristic,stray light and temperature characteristic. As a consequence,the precision of the sunshine duration with automatic observation is improved.
文摘The use of stress-induced changes in a crystal of a monolithic solid-state laser by external force as a way for micro-force detection and measurement is described. In fact, the application of an unknown force on the resonator-amplifier crystal of a solid-state laser leads to a measurable change in the frequency of the beat note associated with the orthogonal polarisation components of the oscillating laser mode. Here we report our first measurements of the sensitivity of a photo-elastic force sensor, realised with a monolithic (4 × 4) mm plano-convex cylindrical crystal, and compare them with the results obtained by other authors for different configurations and dimensions of the laser sensor. The reported results are in a good mutual agreement but show notable discrepancies with theoretical predictions, especially for high sensitivities obtained when the dimensions of the laser sensor are small.