期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Database system for managing 20,00020-inch PMTs at JUNO
1
作者 Jun Wang Nikolay Anfimov +16 位作者 Jing-Yuan Guo Yu Gu Hang Hu Min Li Qiu-Mei Ma Alexander Olshevskiy Zhao-Yuan Peng Zhong-Hua Qin Alexander Tietzsch Bjorn Wonsak Wei Wang Zhi-Min Wang Mei-Hang Xu Wan Xie Zheng-Yun You Hai-Qiong Zhang Rong Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第3期10-21,共12页
A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Li... A database system,known as the large PMT characterization and instrumentation database system(LPMT-CIDS),was designed and implemented for the Jiangmen Underground Neutrino Observatory(JUNO).The system is based on a Linux+Apache+MySQL+PHP(LAMP)server and focuses on modularization and architecture separation.It covers all the testing stages for the 20-inch photomultiplier tubes(PMTs)at JUNO and provides its users with data storage,analysis,and visualization services.Based on the successful use of the system in the 20-inch PMT testing program,its design approach and construction elements can be extended to other projects. 展开更多
关键词 LAMP photomultiplier tubes Jiangmen underground neutrino observatory Data visualization
下载PDF
Effect of annealing atmospheres on the scintillation properties of Ce^(3+)‑doped YAG nanoscintillator
2
作者 Billel Zahra Lakhdar Guerbous +1 位作者 Hicham Bousbia‑salah Allaoua Boukerika 《Radiation Detection Technology and Methods》 CSCD 2023年第3期447-456,共10页
Background In this study,three sample detectors have been prepared by using cerium-activated YAG nanoscintillator(Y_(3)Al_(5)O_(12):Ce^(3+))synthesized by sol-gel method and heat-treat at 900°C for 2 h in differe... Background In this study,three sample detectors have been prepared by using cerium-activated YAG nanoscintillator(Y_(3)Al_(5)O_(12):Ce^(3+))synthesized by sol-gel method and heat-treat at 900°C for 2 h in different atmospheres such as vacuum,air and nitrogen.Purpose Many studies about YAG:Ce^(3+)single crystal have been carried out,but the material at the nanoscale remains not enough understood.The objective of the present paper is to investigate the effects of annealing atmosphere on the scintillation properties and identify the suitable atmosphere that allow to design radiation detectors with high scintillation efficiency.Methods In order to accurately assess the scintillation properties,the nanoscintillator sample powders have been designed as a detector,in which,preparation operations such as surface homogenization and efficiency coupling with photomultiplier tube(PMT)window were developed.The study was performed usingγ-rays 662 keV released from137Cs radioactive source,the bi-alkali GDB-4FF PMT was used as a photodetector.Nuclear instrumentation chain was set up in order to collect the pulse height spectra,NaI:Tl single-crystal scintillator was used as a reference detector to estimate the scintillation light yield.The delayed coincidence method was used for measuring the scintillation decay time of nanoscintillator sample detectors.Results The sample detector annealed at vacuum atmosphere exhibits the best scintillation properties,the scintillation light yield was estimated to be 14,600±3400 ph/MeV and the fast component in the scintillation decay was 90 ns.Conclusion The vacuum is the suitable atmosphere which allows the development of radiation detectors with high scintillation efficiency. 展开更多
关键词 Nanoscintillator YAG:Ce^(3+) Scintillation properties γ-rays 662 keV photomultiplier tube Sample detectors Annealing atmosphere
原文传递
Magnetic shielding for DAMPE electromagnetic calorimeter PMTs
3
作者 王培龙 张云龙 +1 位作者 汪晓莲 许咨宗 《Chinese Physics C》 SCIE CAS CSCD 2014年第8期53-56,共4页
The magnetic characteristics of R5610A-01 photomultiplier tubes are studied in this paper. The experimental data shows that the gain of R5610A-01 loses about 53% when the magnetic field is 3 Gs along its +X axis. A c... The magnetic characteristics of R5610A-01 photomultiplier tubes are studied in this paper. The experimental data shows that the gain of R5610A-01 loses about 53% when the magnetic field is 3 Gs along its +X axis. A cylinder of one-layer permalloy strip is able to reduce the effect of a 3 Gs magnetic field on the PMT gain to less than 1%. 展开更多
关键词 photomultiplier tube magnetic shield CHARACTERISTICS
原文传递
A plastic scintillating fiber position detector in vacuum for the test beam facility at BEPCⅡ-LINAC
4
作者 柯尊建 李家才 +3 位作者 张少平 安广朋 唐兴华 杨涛 《Chinese Physics C》 SCIE CAS CSCD 2012年第1期67-70,共4页
Two plastic scintillating fiber position detectors for charged particles have been designed,built and installed inside the vacuum tube near two sides of the DM2 deflection magnet on the E3 beam line of the test beam f... Two plastic scintillating fiber position detectors for charged particles have been designed,built and installed inside the vacuum tube near two sides of the DM2 deflection magnet on the E3 beam line of the test beam facility at the BEPC-LINAC.A one-dimensional position resolution of~1 mm with a sensitive area of 60 mm×60 mm has been obtained for this detector. 展开更多
关键词 plastic scintillating fiber multi-anode photomultiplier tube VACUUM
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部