RADIONUCLIDES IN RICE IN HONG KONG
1
作者 余君岳 茅瑞恩 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第3期176-180,共5页
Radionuclide contents in imported rice are determined using the EG&G ORTEC photon spectrometer system. Most of the natural radionuclides are found to have specific activities below the detectable limit. 40K has va... Radionuclide contents in imported rice are determined using the EG&G ORTEC photon spectrometer system. Most of the natural radionuclides are found to have specific activities below the detectable limit. 40K has values ranging from 0.104to 32.97 Bq/kg; 137Cs from 0.009 to 0.52 Bq/kg; and 95Zr less than 0.077 Bq/kg. The annual effective dose for a male and a female adult is 18μSv and 12.7μSv, respectively. Both are less than the value recommended by the International Commission of Radiological Protection. 展开更多
关键词 photon spectrometer system RICE  ̄(40)K  ̄(137)Cs  ̄(95)Zr Weighted committed dose equivalent
下载PDF
Radiofrequency field enhanced chemical ionization with vacuum ultraviolet lamp for miniature time-of-flight mass spectrometer 被引量:1
2
作者 Lijuan Zhou Jichun Jiang +5 位作者 Kun Zhao Jinxu Li Chenxin Wu Haiyang Li Di Tian Keyong Hou 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第5期707-710,共4页
It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency f... It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis. 展开更多
关键词 Radio-frequency field enhanced chemical ionization Vacuum ultraviolet lamp Single photon ionization Miniature time-of-flight mass spectrometer On site analysis
原文传递