期刊文献+
共找到1,153篇文章
< 1 2 58 >
每页显示 20 50 100
Soft-switching Grid-connected PV Inverter With Interleaved Flyback Topology 被引量:15
1
作者 古俊银 吴红飞 +1 位作者 陈国呈 邢岩 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0005-I0005,共1页
提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断... 提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断电压尖峰;提出基于数字处理器的反激变换器变开关频率谐振软开关控制策略,实现了开关管的零电压开通,同时改善了逆变器的电磁兼容特性;提出的交错并联反激逆变器有助于减小变压器和滤波器的体积,提高功率密度。详细分析变换器的工作原理,分析变开关频率谐振软开关控制方式的原理和实现条件,最后进行实验验证。 展开更多
关键词 拓扑结构 反激式 逆变器 软交换网 光伏 交错 软交换技术 低成本
下载PDF
Performance Assessment of a Real PV System Connected to a Low-Voltage Grid 被引量:1
2
作者 Gaber Magdy Mostafa Metwally +1 位作者 Adel A.Elbaset Esam Zaki 《Energy Engineering》 EI 2024年第1期13-26,共14页
The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Th... The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient. 展开更多
关键词 Low-voltage grid photovoltaic(pv)system total harmonic distortion grid-connected pv system
下载PDF
H6 Non-isolated Full Bridge Grid-connected PV Inverters With Low Leakage Currents 被引量:29
3
作者 ZHANG Li SUN Kai +2 位作者 FENG Lanlan XING Yan XU Ming 《中国电机工程学报》 EI CSCD 北大核心 2012年第15期I0001-I0022,21,共22页
为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有... 为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有利于热应力均衡,且仍满足续流阶段光伏电池输出端与电网脱离的要求。详细分析拓扑的工作原理,并推论给出H6非隔离光伏并网逆变器的其它3种拓扑结构;比较分析了H5拓扑、Heric拓扑和H6拓扑的损耗和成本。通过1kW通用样机平台对比验证了上述3种拓扑的效率和共模特性。实验结果表明,H6拓扑的变换效率高于H5拓扑、但略低于Heric拓扑,共模特性优于Heric拓扑、但略劣于H5拓扑。 展开更多
关键词 全桥逆变器 并网逆变器 漏电流 共模电压 光伏发电
下载PDF
A Review of Novel Leakage Current Suppression Techniques for Transformerless Photovoltaic Inverters 被引量:32
4
作者 WU Weiyang GUO Xiaoqiang 《中国电机工程学报》 EI CSCD 北大核心 2012年第18期I0001-I0022,170,共22页
漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探... 漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探讨不同调制策略对漏电流的影响,然后介绍几种典型的、能够有效抑制漏电流的电路拓扑结构,并分析各种拓扑的工作原理和特点。最后对漏电流抑制技术方面的发展趋势做了展望。 展开更多
关键词 新型变压器 光伏系统 漏电流 逆变器 技术 综述 低成本 电网
下载PDF
An Efficient Fuzzy Logic Fault Detection and Identification Method of Photovoltaic Inverters 被引量:1
5
作者 Mokhtar Aly Hegazy Rezk 《Computers, Materials & Continua》 SCIE EI 2021年第5期2283-2299,共17页
Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-ti... Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-tied photovoltaic(PV)inverters.Large installations and ambitious plans have been recently achieved for PV systems as clean and renewable power generation sources due to their improved environmental impacts and availability everywhere.Power converters represent the main parts for the grid integration of PV systems.However,PV power converters contain several power switches that construct their circuits.The power switches in PV systems are highly subjected to high stresses due to the continuously varying operating conditions.Moreover,the grid-tied systems represent nonlinear systems and the system model parameters are changing continuously.Consequently,the grid-tied PV systems have a nonlinear factor and the fault detection and identification(FDI)methods based on using mathematical models become more complex.The proposed fuzzy logic-based FDI(FL-FDI)method is based on employing the fuzzy logic concept for detecting and identifying the location of various switch faults.The proposed FL-FDI method is designed and extracted from the analysis and comparison of the various measured voltage/current components for the control purposes.Therefore,the proposed FL-FDI method does not require additional components or measurement circuits.Additionally,the proposed method can detect the faulty condition and also identify the location of the faulty switch for replacement and maintenance purposes.The proposed method can detect the faulty condition within only a single fundamental line period without the need for additional sensors and/or performing complex calculations or precise models.The proposed FL-FDI method is tested on the widely used T-type PV inverter system,wherein there are twelve different switches and the FDI process represents a challenging task.The results shows the superior and accurate performance of the proposed FL-FDI method. 展开更多
关键词 Fault detection and identification fuzzy logic T-type inverter photovoltaic(pv)
下载PDF
A Current sensorless MPPT Algorithm for Single-stage Grid-connected PV Inverters 被引量:1
6
作者 GU Junyin CHEN Guocheng 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0019-I0019,共1页
关键词 电流传感器 功率逆变器 MPPT 光伏 单级 算法 最大功率点 并网
下载PDF
Extended Quality Characterization of Grid Connected PV Inverters
7
作者 Georg Lauss Roland Bruendlinger Benoit Bletterie Christoph Mayr 《电力电子技术》 CSCD 北大核心 2013年第3期11-14,20,共5页
The overall performance of photovoltaic (PV) inverter imphes many different technical issues.One of the key criterias is based on the measurement of the conversion and the maximum power point tracking (MPPT) effic... The overall performance of photovoltaic (PV) inverter imphes many different technical issues.One of the key criterias is based on the measurement of the conversion and the maximum power point tracking (MPPT) efficiency and its applicable evaluation in practice.Intense work has been done in the last few years to formulate applicable standards for measuring static and dynamic efficiencies worldwide.Besides that,this work is presenting on novel methods of analysis on non-trivial system characteristics impacting the final evaluation on the overall performance of the PV inverter.The elaborated testing procedures for complex system behavior under highly nonlinear conditions (unintentional partial shading, mismatching of DC strings) are explained and characterized.With the help of experimental results, the exclusive impact on the overall efficiency is illustrated and helpful statements are given on the resulting technical characteristics of MPP strategies. 展开更多
关键词 grid CONNECTED photovoltaic inverter conversion efficiency MAXIMUM power point tracking quality
下载PDF
Research and Design of Inverter Applied in Solar PV Systems Connected to Distribution Grid
8
作者 Nguyen Duc Minh Trinh Trong Chuong +2 位作者 Bui Van Huy Quach Duc Cuong Bui Dinh Thanh 《Journal of Electrical Engineering》 2019年第1期28-38,共11页
This paper presents the results of research on the application of inverter in the grid connected solar photovoltaics (PV) system. The main content of the article is to control the three-phase grid connected inverter t... This paper presents the results of research on the application of inverter in the grid connected solar photovoltaics (PV) system. The main content of the article is to control the three-phase grid connected inverter to meet the requirement of controlling the reactive power to zero at a node of the distribution network while maximizing the active power transmitted to the grid. The control circuits are synthesized on the dq coordinate system and verified on the simulation model by Matlab/Simulink. Both simulation and experimental prototype on 5 kW inverter, being connected to low voltage grid, have been built to show the good results and the practical readiness for implementation. 展开更多
关键词 SVPWM REACTIVE power solar pv grid CONNECTED inverter
下载PDF
Testing PV Central Inverters' Compliance with International Grid Codes
9
作者 Robin Grab Soenke Rogalla Roland Singer Gregor Doetter 《Journal of Energy and Power Engineering》 2014年第9期1552-1558,共7页
In many electrical grids worldwide, the rising amount of installed PV (photovoltaic) power entails a considerable influence of PV systems on grid quality and stability. Consequently, in the wake of the revised Germa... In many electrical grids worldwide, the rising amount of installed PV (photovoltaic) power entails a considerable influence of PV systems on grid quality and stability. Consequently, in the wake of the revised German medium voltage directives issued in 2009, new requirements for PV inverters have been established internationally. At Fraunhofer ISE's Inverter Laboratory, approximately 25 large PV inverters with a nominal power of up to 880 kVA have been characterized in the past three years. In this period, the focus of many inverter manufacturers has begun to shift from traditional European markets towards an international perspective. Therefore, experiences with numerous different grid codes have been gained by our team. This work summarizes the similarities and differences between these grid codes. Additionally, several requirements that have proved to be critical will be examined. Finally, the adequacy of these grid codes to guarantee the safe and reliable operation of electrical grids is discussed. 展开更多
关键词 Large grid-connected pv systems inverter grid stability grid integration electrical properties.
下载PDF
Inverter Power Stage Connected with PV-Grid
10
作者 K. Kirubasankar Dr. A. Senthil Kumar 《Circuits and Systems》 2016年第13期4113-4123,共11页
This paper focuses on the design of the inverter power stage connected with PV-grid which supports the contrived PV system. The increased number of grid connected photovoltaic (PV) inverters gave rise to problems conc... This paper focuses on the design of the inverter power stage connected with PV-grid which supports the contrived PV system. The increased number of grid connected photovoltaic (PV) inverters gave rise to problems concerning the stability and safety of the utility grid, as well as power quality issues. The proposed systems can overcome these issues and improve standard regulation methods for gird connected PV inverter. The maximum available voltage in the PV string is tracked by the power stage which has been planned and designed in such a way. The tracked voltage is boosted then. The important components to voltage source inverter (VSI) are boost inductor and input capacitor which are calculated. To get a clear sinusoidal output phase voltage of 230 V from a DC capacitance bus projected to deal with 400 V, the important inverter stage parameters have been planned and modeled in Mat lab. Each block stage of the converter is easily understandable by the Simlink of the dual stage DC-AC converter explanation. The control schemes which have been proposed would compromise with the inverter power stage which forms the neat grid system. The existing renewable energy sources in the laboratory are integrated by the proposed control. 展开更多
关键词 pv-grid Maximum Power Point Tracking inverter Power Stage Converter
下载PDF
Design of Grid-Connected Photovoltaic System
11
作者 Naseer Khan Muhammad Aamir +2 位作者 Faisal Mehmood Muhammad Aslam Muhammad Arif 《Journal of Power and Energy Engineering》 2017年第8期1-12,共12页
This paper presents a grid connected photovoltaic system (PV) with a proposed high voltage conversion ratio DC-DC converter which steps up the variable low input voltages of photovoltaic module to the required DC link... This paper presents a grid connected photovoltaic system (PV) with a proposed high voltage conversion ratio DC-DC converter which steps up the variable low input voltages of photovoltaic module to the required DC link voltage. This voltage is applied to an H-bridge inverter which converts DC voltage into AC voltage and a low pass filter is used to filter the output. By adjusting the duty ratio of switches in DC-DC converter, the magnitude of inverter’s output voltage is controlled. The frequency and phase synchronization are ensured by a feedback signal taken from the grid. In this way, inverter is synchronized and connected with the grid to meet the energy demand. The PV system has been designed and simulated. 展开更多
关键词 photovoltaic Systems (pv) High Voltage GAIN DC-DC CONVERTER PWM inverter SYNCHRONIZATION
下载PDF
Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal
12
作者 P. W. Tavares H. D. Ndiath +3 位作者 M. Kane B. Mbow A. T. Niang I. Youm 《International Journal of Clean Coal and Energy》 2020年第1期1-14,共14页
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura... This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection. 展开更多
关键词 Analysis of the PERFORMANCES The photovoltaic SOLAR Energy grid-CONNECTED pv System Senegal
下载PDF
Performance and Efficiency Simulation Study of a Smart-Grid Connected Photovoltaic System
13
作者 Warsame H. Ali Penrose Cofie +2 位作者 John H. Fuller Savitha Lokesh Emmanuel S. Kolawole 《Energy and Power Engineering》 2017年第2期71-85,共15页
The availability of non-renewable energy sources such as crude oil, natural gas, coal etc., is fast diminishing. So the renewable energy sources such as solar, hydropower, geothermal, wind, tidal energy, are gaining m... The availability of non-renewable energy sources such as crude oil, natural gas, coal etc., is fast diminishing. So the renewable energy sources such as solar, hydropower, geothermal, wind, tidal energy, are gaining more and more importance. Many new developments to convert these renewable energy sources into usable forms are taking place. Most renewable energy sources are used to produce electricity. In this paper, a performance and efficiency simulation study of a smart-grid connected photovoltaic system using Chroma DC programmable power supply, AC programmable source and an Aurora Inverter is proposed. The simulation is performed in MATLAB environment where the Current-Voltage (I-V) and Power-Voltage (P-V) curves from the solar array simulator are generated and plotted. The proposed topology has been verified with satisfactory results. In addition, temperature and irradiance effects on I-V and P-V characteristic curves are verified. Also, the efficiency curves of the photovoltaic grid interface inverter are generated in the study. The MATLAB code developed in this paper is a valuable tool for design engineers comparing different inverters, calculating the optimum efficiency of a given inverter type. 展开更多
关键词 Smart-grid photovoltaic System RENEWABLE and of Non-Renewable Energy CURRENT-VOLTAGE (I-V) and Power-Voltage (P-V) CURVES inverter Electricity
下载PDF
Low Voltage Ride through Control Capability of a Large Grid Connected PV System Combining DC Chopper and Current Limiting Techniques 被引量:1
14
作者 Ronald Ntare Nabil H. Abbasy Karim H. M. Youssef 《Journal of Power and Energy Engineering》 2019年第1期62-79,共18页
This paper presents the development and performance capability of a comprehensive Low voltage ride through (LVRT) control scheme that makes use of both the DC chopper and the current limiting based on the required rea... This paper presents the development and performance capability of a comprehensive Low voltage ride through (LVRT) control scheme that makes use of both the DC chopper and the current limiting based on the required reactive power during fault time. The study is conducted on an 8.5 MW single stage PV power plant (PVPP) connected to the Rwandan grid. In the event of fault disturbance, this control scheme helps to overcome the problems of excessive DC-link voltage by fast activation of the DC chopper operation. At the same instance, AC current is limited to the maximum rating of the inverter as a function of the injected reactive current. This helps overcome AC-over- current that may possibly lead to damage or disconnection of the inverter. The control scheme also ensures voltage support and power balance through the injection of reactive current as per grid code requirements. Selected simulations using MATLAB are carried out in the events of different kinds of fault caused voltage dips. Results demonstrate the effectiveness of the proposed LVRT control scheme. 展开更多
关键词 grid CONNECTED photovoltaic (pv) Power Plants (GCPSs) VOLTAGE Dips Low VOLTAGE RIDE Through (LVRT) grid Code (GC)
下载PDF
Study and Design of a DC/AC Energy Converter for PV System Connected to the Grid Using Harmonic Selected Eliminated (HSE) Approach 被引量:1
15
作者 Dominique Bonkoungou Éric Korsaga +3 位作者 Toussaint Guingané Sosthène Tassembédo Zacharie Koalaga François Zougmoré 《Open Journal of Applied Sciences》 2022年第3期301-316,共16页
Nowadays, distributing network-connected photovoltaic (PV) systems are expanded by merging a PV system and a Direct Current (DC)/Alternating Current (AC) energy converter. DC/AC conversion of PV energy is in great dem... Nowadays, distributing network-connected photovoltaic (PV) systems are expanded by merging a PV system and a Direct Current (DC)/Alternating Current (AC) energy converter. DC/AC conversion of PV energy is in great demand for AC applications. The supply of electrical machines and transfer energy to the distribution network is a typical case. In this work, we study and design a DC/AC energy converter using harmonic selective eliminated (HSE) method. To this end, we have combined two power stages connected in derivation. Each power stage is constituted of transistors and transformers. The connection by switching of the two rectangular waves, delivered by each of the stages, makes it possible to create a quasi-sinusoidal output voltage of the inverter. Mathematical equations based on the current-voltage characteristics of the inverter have been developed. The simulation model was validated using experimental data from a 25.2 kWp grid-coupled (PV) system, connected to Gridfit type inverters. The data were exported and implemented in programming software. A good agreement was observed and this shows all the robustness and the technical performances of the energy converter device. It emerges from this analysis that the inverter output voltage and the phase angle thus simulated are very important to control in order to orientate the transfer of the power flow from the continuous cell to cell to the alternating part. Simulated and field-testing results also show that increases in the value of the modulation factor (m) for low power output are highly significant. This study is an important tool for DC/AC inverter designers during initial planning stages. A short presentation of the design model of the inverter has been proposed in this article. 展开更多
关键词 inverter Modulation Index TRANSISTORS Power Stage Harmonic Selective Eliminated photovoltaic (pv) System
下载PDF
A SRF-PLL Control Scheme for DVR to Achieve Grid Synchronization and PQ Issues Mitigation in PV Fed Grid Connected System
16
作者 Saritha Natesan Jamuna Venkatesan 《Circuits and Systems》 2016年第10期2996-3015,共20页
This paper presents the Synchronous Reference Frame Theory (SRF) based Phase Locked Loop (PLL) to enhance the performance of Dynamic Voltage Controller (DVR). In a grid connected power conversion system, a critical co... This paper presents the Synchronous Reference Frame Theory (SRF) based Phase Locked Loop (PLL) to enhance the performance of Dynamic Voltage Controller (DVR). In a grid connected power conversion system, a critical component is the Phase-Locked Loop (PLL) that generates the grid voltage’s frequency and phase angle for the grid synchronization. For grid voltage control, accurate and fast responding PLLs are required to provide phase angle and frequency measurements of the grid voltage. Therefore, SRF based PLL is presented in this work and it calculates the phase angle accurately and effectively. This paper also presents a novel feedback mechanism for SRF-PLL which uses the estimated frequency and phase to achieve grid control. The fundamental signal of the grid voltage is extracted by low pass filter and a unit value controller to generate a unity sine reference signal for the feedback network. In particular, the performance of the SRF-PLL in the three-phase PV fed grid connected system is analyzed under the different power quality issues such as voltage sag and swell. In addition, a detailed study on synchronous reference frame theory is presented. An appropriate control algorithm for DVR is developed and the validity of the proposed configuration is verified through MATLAB simulation results as well as experimental results under different operating conditions. 展开更多
关键词 photovoltaic (pv) Multi-Level inverter Total Harmonic Distortion (THD) Power Quality dq Frame
下载PDF
Improved Interleaved Single-Ended Primary Inductor-Converter forSingle-Phase Grid-Connected System
17
作者 T.J.Thomas Thangam K.Muthu Vel 《Intelligent Automation & Soft Computing》 SCIE 2023年第3期3459-3478,共20页
The generation of electricity based on renewable energy sources,parti-cularly Photovoltaic(PV)system has been greatly increased and it is simply insti-gated for both domestic and commercial uses.The power generated fr... The generation of electricity based on renewable energy sources,parti-cularly Photovoltaic(PV)system has been greatly increased and it is simply insti-gated for both domestic and commercial uses.The power generated from the PV system is erratic and hence there is a need for an efficient converter to perform the extraction of maximum power.An improved interleaved Single-ended Primary Inductor-Converter(SEPIC)converter is employed in proposed work to extricate most of power from renewable source.This proposed converter minimizes ripples,reduces electromagnetic interference due tofilter elements and the contin-uous input current improves the power output of PV panel.A Crow Search Algo-rithm(CSA)based Proportional Integral(PI)controller is utilized for controlling the converter switches effectively by optimizing the parameters of PI controller.The optimized PI controller reduces ripples present in Direct Current(DC)vol-tage,maintains constant voltage at proposed converter output and reduces over-shoots with minimum settling and rise time.This voltage is given to single phase grid via 1�Voltage Source Inverter(VSI).The command pulses of 1�VSI are produced by simple PI controller.The response of the proposed converter is thus improved with less input current.After implementing CSA based PI the efficiency of proposed converter obtained is 96%and the Total Harmonic Distor-tion(THD)is found to be 2:4%.The dynamics and closed loop operation is designed and modeled using MATLAB Simulink tool and its behavior is performed. 展开更多
关键词 Improved interleaved DC-DC SEPIC converter crow search algorithm PI controller voltage source inverter pv array single phase grid
下载PDF
光伏多功能并网逆变器不同出力状态下无功和谐波优化方法 被引量:4
18
作者 王果 武旭 +4 位作者 李龙 张梦圆 李旭哲 成柯 张建雄 《电力自动化设备》 EI CSCD 北大核心 2024年第1期80-87,共8页
利用光伏多功能并网逆变器所具有的电能质量治理、谐波谐振抑制的主动优势,结合逆变器在不同出力状态下光伏发电系统的输出特性,构建光伏多功能并网逆变器不同出力状态下的无功和谐波优化方法。在所提3层优化策略中,上层优化策略以光伏... 利用光伏多功能并网逆变器所具有的电能质量治理、谐波谐振抑制的主动优势,结合逆变器在不同出力状态下光伏发电系统的输出特性,构建光伏多功能并网逆变器不同出力状态下的无功和谐波优化方法。在所提3层优化策略中,上层优化策略以光伏并网有功功率最大化为目标函数,中层优化策略以电压谐波总畸变率和电压偏差达到相应电能质量规定指标为目标函数,下层优化策略以电压谐波总畸变率和电压偏差最小为目标函数,并采用自适应蚁群算法进行求解。基于IEEE 33节点系统进行算例分析,结果表明:基于逆变器不同出力状态的优化方法可以有效改善电网的电能质量,较好地提升电网运行的经济性;在系统稳定运行的基础上,光伏多功能并网逆变器在不同出力状态下分阶段、分主次地治理谐波和调整电压偏差,治理效果更佳。 展开更多
关键词 光伏发电系统 多功能并网逆变器 优化策略 无功优化 谐波治理
下载PDF
基于RBF神经网络的光伏并网系统自适应等效建模方法
19
作者 张姝 陈豪 肖先勇 《电力系统保护与控制》 EI CSCD 北大核心 2024年第4期77-86,共10页
针对广义负荷建模中的光伏并网系统模型难以适应不同逆变器控制和频率扰动的动态响应问题,提出了一种基于径向基函数(radialbasisfunction,RBF)神经网络的光伏并网系统自适应等效建模方法。首先,建立了光伏并网逆变器不同控制策略响应... 针对广义负荷建模中的光伏并网系统模型难以适应不同逆变器控制和频率扰动的动态响应问题,提出了一种基于径向基函数(radialbasisfunction,RBF)神经网络的光伏并网系统自适应等效建模方法。首先,建立了光伏并网逆变器不同控制策略响应波形的检测判据。然后,构建了以电压-频率扰动为输入,有功功率和无功功率为输出的光伏并网系统RBF神经网络模型。最后,在Matlab/Simulink中搭建了光伏并网系统模型,并将其接入IEEE14节点配电网进行仿真验证。结果表明,构建的光伏并网自适应等效模型能够有效辨识电压频率给定控制、有功无功给定控制、下垂控制策略类型,能够准确反映光伏并网系统在不同电压、频率扰动下的有功功率、无功功率的动态响应特性。 展开更多
关键词 光伏并网系统 等效建模 逆变器控制 电压-频率扰动 RBF神经网络
下载PDF
太阳光照环境对于光伏并网逆变器温升影响的研究
20
作者 杨雪蛟 田伟 +1 位作者 陈苏声 王婷婷 《环境技术》 2024年第9期77-80,共4页
光伏并网逆变器需长期工作在太阳光照暴露环境中,目前关于太阳光照对于光伏并网逆变器运行稳定性的影响的相关研究却几乎没有,光伏并网逆变器的相关检测、认证也无光照条件方面的要求。但部分光伏电站的运维人员却发现光伏并网逆变器在... 光伏并网逆变器需长期工作在太阳光照暴露环境中,目前关于太阳光照对于光伏并网逆变器运行稳定性的影响的相关研究却几乎没有,光伏并网逆变器的相关检测、认证也无光照条件方面的要求。但部分光伏电站的运维人员却发现光伏并网逆变器在较强光照条件下会出现降载、停机等故障,其引发的弃光限电问题愈发受到重视。本文通过研究在不同辐照度的太阳光照环境下光伏并网逆变器各部件温升的数据分析发现,在温升试验时,额外施加的太阳光照对光伏并网逆变器的温升有着额外的提升,且越高辐照度的太阳光照对光伏并网逆变器的温升影响越大。本文可为光伏并网逆变器的设计安装及电站运维提供参考。 展开更多
关键词 光伏并网逆变器 温升试验 太阳辐照度
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部