期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Molar volume of eutectic solvents as a function of molar composition and temperature 被引量:1
1
作者 Farouq S.Mjalli 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第12期1779-1785,共7页
The conventional Rackett model for predicting liquid molar volume has been modified to cater for the effect of molar composition of the Deep Eutectic Solvents(DES). The experimental molar volume data for a group of co... The conventional Rackett model for predicting liquid molar volume has been modified to cater for the effect of molar composition of the Deep Eutectic Solvents(DES). The experimental molar volume data for a group of commonly used DES has been used for optimizing the improved model. The data involved different molar compositions of each DES. The validation of the new model was performed on another set of DESs. The average relative deviation of the model on the training and validation datasets was approximately 0.1% while the Rackett model gave a relative deviation of more than 1.6%. The modified model deals with variations in DES molar composition and temperature in a more consistent way than the original Rackett model which exhibits monotonic performance degradation as temperature moves away from reference conditions. Having the composition of the DES as a model variable enhances the practical utilization of the predicting model in diverse design and process simulation applications. 展开更多
关键词 Molar volume Density physical properties Ionic liquids Eutectic solvents
下载PDF
New process development and process evaluation for capturing CO2 in flue gas from power plants using ionic liquid[emim][Tf2N] 被引量:2
2
作者 Lan Li Xiaoting Huang +3 位作者 Quanda Jiang Luyue Xia Jiawei Wang Ning Ai 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第3期721-732,共12页
Using the ionic liquid[emim][Tf2N]as a physical solvent,it was found by Aspen Plus simulation that it was possible to attempt to capture CO2 from the flue gas discharged from the coal-fired unit of the power plant.Usi... Using the ionic liquid[emim][Tf2N]as a physical solvent,it was found by Aspen Plus simulation that it was possible to attempt to capture CO2 from the flue gas discharged from the coal-fired unit of the power plant.Using the combination of model calculation and experimental determination,the density,isostatic heat capacity,viscosity,vapor pressure,thermal conductivity,surface tension and solubility of[emim][Tf2N]were obtained.Based on the NRTL model,the Henry coefficient and NRTL binary interaction parameters of CO2 dissolved in[emim][Tf2N]were obtained by correlating[emim][Tf2N]with the gas–liquid equilibrium data of CO2.Firstly,the calculated relevant data is imported into Aspen Plus,and the whole process model of the ionic liquid absorption process is established.Then the absorption process is optimized according to the temperature distribution in the absorption tower to obtain a new absorption process.Finally,the density,constant pressure heat capacity,surface tension,thermal conductivity,and viscosity of[emim][Tf2N]were changed to investigate the effect of ionic liquid properties on process energy consumption,solvent circulation and heat exchanger design.The results showed that based on the composition of the inlet gas stream to the absorbers,CO2 with a capture rate of 90%and a mass purity higher than 99.5%was captured.These results indicate that the[emim][Tf2N]could be used as a physical solvent for CO2 capture from coal-fired units.In addition,the results will provide a theoretical basis for the design of new ionic liquids for CO2 capture. 展开更多
关键词 Ionic liquids CO2 capture Aspen Plus process simulation New green physical solvents Flue gas
下载PDF
Novel manganese(Ⅱ)-based deep eutectic solvents: Synthesis and physical properties analysis 被引量:5
3
作者 Koon-Kee Kow Kamaliah Sirat 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第10期1311-1314,共4页
Type IV deep eutectic solvent(DES) involves the formation of metal-based eutectics from metal salts or metal salt hydrate in combination with various hydrogen-bond donors(HBDs) such as urea, ethylene glycol or ace... Type IV deep eutectic solvent(DES) involves the formation of metal-based eutectics from metal salts or metal salt hydrate in combination with various hydrogen-bond donors(HBDs) such as urea, ethylene glycol or acetamide. In current study, two distinguished approaches were used to synthesize potential DESs, given as the direct heating and the evaporating methods. Successful synthesized DESs were subjected for physical properties characterization by Fourier Transform Infrared(FTIR) Spectroscopy, thermal stability, viscosity,and conductivity analyses. Five novel manganese(II)-based DESs were successfully synthesized as reported in this study. Data obtained indicated that the Mn Cl2á4H2Oáacetamide DES exhibits the lowest freezing point(27.5℃), highest thermal stability(193℃ point of dehydration), lowest viscosity(E = 112.8cP) and the highest conductivity(0.12723 mS/cm). The findings obtained reveal the characteristics, nature or features of synthesized DESs as potential industrial solvents. 展开更多
关键词 Ionic liquid Deep eutectic solvents Manganese solvent synthesis physical properties
原文传递
Synthesis and characterization of novel ternary deep eutectic solvents 被引量:4
4
作者 Yu-Ting Liu Yan-An Chen Yan-Jun Xing 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第1期104-106,共3页
A series of room-temperature ternary deep eutectic solvents (TDESs) were prepared from imidazolium halides, zinc halides and amides. The [BMIM]Cl-ZnCl2-acetamide (1:1:1) system shows the lowest freezing point (... A series of room-temperature ternary deep eutectic solvents (TDESs) were prepared from imidazolium halides, zinc halides and amides. The [BMIM]Cl-ZnCl2-acetamide (1:1:1) system shows the lowest freezing point (-60℃) and lowest density in the series. The viscosity and conductivity of TDESs have an exponential relationship with temperature and can be fitted by Arrhenius equation. 展开更多
关键词 Ternary deep eutectic solvents Room-temperature Synthesis physical properties
原文传递
Techno-economic comparison of three technologies for precombustion CO2 capture from a lignite-fired IGCC 被引量:4
5
作者 Simon Roussanaly Monika Vitvarova +5 位作者 Rahul Anantharaman David Berstad Brede Hagen Jana Jakobsen Vaclav Novotny Geir Skaugen 《Frontiers of Chemical Science and Engineering》 SCIE EI CAS CSCD 2020年第3期436-452,共17页
This paper compares the techno-economic performances of three technologies for CO2 capture from a lignite-based IGCC power plant located in the Czech Republic:(1)Physical absorption with a Rectisol-based process;(2)Po... This paper compares the techno-economic performances of three technologies for CO2 capture from a lignite-based IGCC power plant located in the Czech Republic:(1)Physical absorption with a Rectisol-based process;(2)Polymeric CO2-selective membrane-based capture;(3)Low-temperature capture.The evaluations show that the IGCC plant with CO2 capture leads to costs of electricity between 91 and 120€·MWh−1,depending on the capture technology employed,compared to 65€·MWh−1 for the power plant without capture.This results in CO2 avoidance costs ranging from 42 to 84€·tCO2,avoided−1,mainly linked to the losses in net power output.From both energy and cost points of view,the low-temperature and Rectisol based CO2 capture processes are the most efficient capture technologies.Furthermore,partial CO2 capture appears as a good mean to ensure early implementation due to the limited increase in CO2 avoidance cost when considering partial capture.To go beyond the two specific CO2-selective membranes considered,a cost/membrane property map for CO2-selective membranes was developed.This map emphasise the need to develop high performance membrane to compete with solvent technology.Finally,the cost of the whole CCS chain was estimated at 54€·tCO2,avoided−1 once pipeline transport and storage are taken into consideration. 展开更多
关键词 carbon capture and storage(CCS) techno-economic comparison pre-combustion capture physical solvent low-temperature capture
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部