Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering case...Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0.展开更多
Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed ...Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed with undesired interference components,often featuring as high-frequency fluctuations.Previous studies have revealed that sectional geometry(shape and size)greatly affects the high-frequency interference.In this study,low strain dynamic testing on full-scale X-section concrete is conducted in order to investigate the influences of high-frequency interference on velocity responses at the pile head.Emphasis is placed on the frequency and peak value of interference waves at various receiving points.Additionally,the effects of the geometrical,and mechanical properties of the pile shaft on high-frequency interference are elaborated on through the three-dimensional finite element method.The results show that the measured wave is obscured by interference waves superposed by two types of high-frequency components.The modulus and cross-sectional area are contributing factors to the frequency and peak value of the interference waves.On the other hand,the position with the least interference is determined,to some extent,by the accurate shape of the X-section.展开更多
The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temper...The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temperature and ice content of frozen ground,the interface contact relationship between pile foundation and frozen soil is complicated,making pile axial load measurements more uncertain than that in non-frozen ground.Therefore,it is necessary to gain an in-depth understanding of the current pile axial load test methods.Four methods are systematically reviewed:vibrating wire sensors,strain gauges,sliding micrometers,and optical fiber strain sensors.At the same time,the applicability of the four test methods in frozen soil regions is discussed in detail.The first two methods are mature and commonly used.The sliding micrometer is only suitable for short-term measurement.While the Fiber Bragg grating(FBG)strain gauge meets the monitoring requirements,the Brillouin optical time-domain reflectometer(BOTDR)needs further verification.This paper aims to provide a technical reference for selecting and applying different methods in the pile axial load test for the stability study and bearing capacity assessment of pile foundations in cold regions.展开更多
Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.T...Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.The results indicate that displacement amplitude of the pile head in sloping ground topography is larger than in horizontal ground.Differential displacement at various positions of the pile cap is observed in non-horizontal topography.Afterwards,a numerical algorithm is employed to further explore the essential response characteristics in group piles of different topography configurations,which has been verified by the test results.The lengths of the exposed and frictional segment,together with the thickness of the subsoil layer,are the dominant factors which cause non-axisymmetric vibration at the pile cap.展开更多
A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is in...A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is introduced in this paper. This construction method uses a combination of pile foundation construction together with common ground improvement methods, including deep mixing, preloading and sand compaction piling, and it is referred to as the composite ground pile method. Since an artificial ground with relatively high rigidity comparing with that of the original ground was formed around the pile in this method, and the seismic performance has not been made clear, thus the seismic performance of piles in composite ground was systematically analyzed through a series of centrifuge model tests and numerical analyses by using dynamic nonlinear finite element method, and a verification method for the seismic performance of piles in composite ground was proposed on the basis of the experimental and numerical results.展开更多
为从宏、细观角度揭示常法向刚度(Constant Normal Stiffness,CNS)条件下锯齿状砂岩-混凝土结构面剪切机制,首先采用湖南大学自主改造的CNS岩石直剪仪开展3组砂岩-混凝土结构面室内剪切试验.在此基础上,采用刚性墙替代法建立与室内试验...为从宏、细观角度揭示常法向刚度(Constant Normal Stiffness,CNS)条件下锯齿状砂岩-混凝土结构面剪切机制,首先采用湖南大学自主改造的CNS岩石直剪仪开展3组砂岩-混凝土结构面室内剪切试验.在此基础上,采用刚性墙替代法建立与室内试验相应的离散元数值模型,并引入3个显式运动学方程控制砂岩试样运动轨迹从而实现CNS条件加载,将数值模拟与试验结果对比验证了模型的合理性.随后,开展16个工况的数值剪切试验,通过观察剪切裂纹扩展和力链演化形态,从细观角度揭示结构面破坏模式和荷载传递机制,并从宏观角度分析锯齿几何尺寸(半波长λ、起伏角θ)和加载边界条件(初始法向应力σn0、法向刚度K)对剪切强度和法向膨胀的影响.结果表明:剪切裂纹按照“平稳增加—急剧增加—增幅减小”的发展趋势由结构面区域逐渐向岩石内部扩展,结构面破坏模式随起伏角的增大由滑移磨损向剪断破坏过渡,剪切强度随λ、θ、σn0和K的增加呈指数函数型增加.展开更多
基金The National Key Research and Development Program(No.2017YFC0703408)the National Natural Science Foundation of China(No.51478109,51678145,51878160)
文摘Based on the characteristics of pile-soil interaction and the Mohr-Coulomb strength theory,a new method of determining the side friction at a pile-soil interaction is proposed.Combined with the actual engineering cases,the effectiveness of the analogue test method is verified by comparing it with the traditional anchor pile method and self-balanced method.Taking the self-balanced test of the bridge pile foundation in the Songhua River as an example,the conversion factor of sandy soil and weathered mudstone are confirmed by the analogue test method.The results show that the conversion factor of sandy soil and weathered mudstone in the Songhua River area should consider the geological conditions and the construction technology,etc.The standard values are relatively conservative.It is suggested that the engineering application should be properly revised.The recommended range of the conversion factor of sandy soil in this area is 0.65 to 0.85,and that of weathered mudstone is 1.0.
基金National Natural Science Foundation of China under Grant Nos.51622803 and 51878103China Postdoctoral Science Foundation under Grant No.2021M692689。
文摘Stress waves propagate along vertical,radial and circumferential directions when a non-uniformly distributed load is applied at one end of a three-dimensional shaft.As a result,the receiving signals are usually mixed with undesired interference components,often featuring as high-frequency fluctuations.Previous studies have revealed that sectional geometry(shape and size)greatly affects the high-frequency interference.In this study,low strain dynamic testing on full-scale X-section concrete is conducted in order to investigate the influences of high-frequency interference on velocity responses at the pile head.Emphasis is placed on the frequency and peak value of interference waves at various receiving points.Additionally,the effects of the geometrical,and mechanical properties of the pile shaft on high-frequency interference are elaborated on through the three-dimensional finite element method.The results show that the measured wave is obscured by interference waves superposed by two types of high-frequency components.The modulus and cross-sectional area are contributing factors to the frequency and peak value of the interference waves.On the other hand,the position with the least interference is determined,to some extent,by the accurate shape of the X-section.
基金This study was supported by the Strategic Priority Research Program of the Chinese Academy of Science(Grant No.XDA20020102)Science and Technology Project of State Grid Corporation of China(Contract No.SGQHDKYOSBJS201600077)+1 种基金National Natural Science Foundation of China(Grant No.41101065)the State Key Laboratory of Frozen Soil Engineering Foundation(Grant No.SKLFSE-ZT-34)。
文摘The measurement of pile axial load is of great significance to determining pile foundation design parameters such as skin friction and end bearing capacity and analyzing load transfer mechanisms.Affected by the temperature and ice content of frozen ground,the interface contact relationship between pile foundation and frozen soil is complicated,making pile axial load measurements more uncertain than that in non-frozen ground.Therefore,it is necessary to gain an in-depth understanding of the current pile axial load test methods.Four methods are systematically reviewed:vibrating wire sensors,strain gauges,sliding micrometers,and optical fiber strain sensors.At the same time,the applicability of the four test methods in frozen soil regions is discussed in detail.The first two methods are mature and commonly used.The sliding micrometer is only suitable for short-term measurement.While the Fiber Bragg grating(FBG)strain gauge meets the monitoring requirements,the Brillouin optical time-domain reflectometer(BOTDR)needs further verification.This paper aims to provide a technical reference for selecting and applying different methods in the pile axial load test for the stability study and bearing capacity assessment of pile foundations in cold regions.
基金National Science Foundation of China under Grant Nos.51622803 and 51778092Innovation Group Science Foundation of the Natural Science Foundation of Chongqing,China under Grant No.cstc2020jcyjcxttX0003China Scholarship Council(File No:201806050121)for financial support to visit Purdue University。
文摘Topography effects on the vertical vibration responses of pile group are revealed though numerical analysis and model tests.First,a series of model tests with different topography of ground and bedrock are conducted.The results indicate that displacement amplitude of the pile head in sloping ground topography is larger than in horizontal ground.Differential displacement at various positions of the pile cap is observed in non-horizontal topography.Afterwards,a numerical algorithm is employed to further explore the essential response characteristics in group piles of different topography configurations,which has been verified by the test results.The lengths of the exposed and frictional segment,together with the thickness of the subsoil layer,are the dominant factors which cause non-axisymmetric vibration at the pile cap.
文摘A new construction method of pile foundation in composite ground, in which, prior to installing piles, the ground is improved around the heads of the piles in soft ground or ground subject to liquefaction, which is introduced in this paper. This construction method uses a combination of pile foundation construction together with common ground improvement methods, including deep mixing, preloading and sand compaction piling, and it is referred to as the composite ground pile method. Since an artificial ground with relatively high rigidity comparing with that of the original ground was formed around the pile in this method, and the seismic performance has not been made clear, thus the seismic performance of piles in composite ground was systematically analyzed through a series of centrifuge model tests and numerical analyses by using dynamic nonlinear finite element method, and a verification method for the seismic performance of piles in composite ground was proposed on the basis of the experimental and numerical results.
文摘为从宏、细观角度揭示常法向刚度(Constant Normal Stiffness,CNS)条件下锯齿状砂岩-混凝土结构面剪切机制,首先采用湖南大学自主改造的CNS岩石直剪仪开展3组砂岩-混凝土结构面室内剪切试验.在此基础上,采用刚性墙替代法建立与室内试验相应的离散元数值模型,并引入3个显式运动学方程控制砂岩试样运动轨迹从而实现CNS条件加载,将数值模拟与试验结果对比验证了模型的合理性.随后,开展16个工况的数值剪切试验,通过观察剪切裂纹扩展和力链演化形态,从细观角度揭示结构面破坏模式和荷载传递机制,并从宏观角度分析锯齿几何尺寸(半波长λ、起伏角θ)和加载边界条件(初始法向应力σn0、法向刚度K)对剪切强度和法向膨胀的影响.结果表明:剪切裂纹按照“平稳增加—急剧增加—增幅减小”的发展趋势由结构面区域逐渐向岩石内部扩展,结构面破坏模式随起伏角的增大由滑移磨损向剪断破坏过渡,剪切强度随λ、θ、σn0和K的增加呈指数函数型增加.