期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
1
作者 葛永帅 王志刚 +14 位作者 俞伯祥 谢宇广 章爱武 薛镇 刘颖彪 高龙 牛顺利 蔡啸 方建 孙希磊 吕绮雯 宁飞鹏 周莉 胡涛 吕军光 《Chinese Physics C》 SCIE CAS CSCD 2012年第11期1101-1105,共5页
A novel 2-D cosmic ray position detector has been built and studied. It is integrated from a CsI(Na) crystal pixel array, an optical fiber array, an image intensifier and an ICCD camera. The 2-D positions of one cos... A novel 2-D cosmic ray position detector has been built and studied. It is integrated from a CsI(Na) crystal pixel array, an optical fiber array, an image intensifier and an ICCD camera. The 2-D positions of one cosmic ray track is determined by the location of a fired CsI(Na) pixel. The scintillation light of these 1.0× 1.0 mm CsI(Na) pixels is delivered to the image intensifier through fibers. The light information is recorded in the ICCD camera in the form of images, from which the 2-D positions can be reconstructed. The background noise and cosmic ray images have been studied. The study shows that the cosmic ray detection efficiency can reach up to 11.4%, while the false accept rate is less than 1%. 展开更多
关键词 cosmic ray 2-D position CsI(Na) crystal pixel array optical fiber array image intensifier ICCD camera
原文传递
Study of the characteristics of a scintillation array and single pixels for nuclear medicine imaging applications 被引量:2
2
作者 祝杰 马红光 +3 位作者 马文彦 曾晖 汪兆民 许咨宗 《Chinese Physics C》 SCIE CAS CSCD 2009年第4期285-288,共4页
By using a pixelized Nal(T1) crystal array coupled to a R2486 PSPMT, the characteristics of the array and of a single pixel, such as the light output, energy resolution, peak-to-valley ratio (P/V) and imaging perf... By using a pixelized Nal(T1) crystal array coupled to a R2486 PSPMT, the characteristics of the array and of a single pixel, such as the light output, energy resolution, peak-to-valley ratio (P/V) and imaging performance of the detector were studied. The pixel size of the NaI(TI) scintillation pixel array is 2 mm×2 mm×5 mm. There are in total 484 pixels in a 22×22 matrix. In the pixel spectrum an average peak-to-valley ratio (P/V) of 16 was obtained. In the image of all the pixels, good values for the Peak-to- Valley ratios could be achieved, namely a mean of 17, a maximum of 45 and the average peak FWHM (the average value of intrinsic spatial resolution) of 2.3 mm. However, the PSPMT non-uniform response and the scintillation pixels array inhomogeneities degrade the imaging performance of the detector. 展开更多
关键词 CHARACTERISTICS scintillation pixels array light output peak-to-valley ratio
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部