To preliminarily determine the appropriate dosage of carboplatin (CBP) at AUC of 5 mg-M1^-1·min^-1 in the combination chemotherapy for Chinese senile patients with non-small cell lung cancer (NSCLC). Thirty-f...To preliminarily determine the appropriate dosage of carboplatin (CBP) at AUC of 5 mg-M1^-1·min^-1 in the combination chemotherapy for Chinese senile patients with non-small cell lung cancer (NSCLC). Thirty-five Chinese senile patients with NSCLC in advanced stage (Ⅲ/Ⅳ) were given 96 cycles of combination chemotherapy. Chemotherapy schedules included Taxol+CBP, Gemzar+CBP and NVB+CBE The dose of CBP was at 5 mg.mL^-1·min^-1 of area under the concentration-time curve (AUC). Side effects and quality of life were observed before and after the chemotherapy. Myelosuppression was severe and commonly observed. Grade 3/4 of granulocytopenia was found in 47.9% (46/96) of the patients and grade 3/4 of thrombocytopenia was noted in 28.1% (27/96) of the subjects. However, other side effects were slight. The mean score of quality of life (QOL), according to the criteria of QOL for Chinese cancer patients had reduced 6.8. At 5 mg.mL^-1·min^-1 by AUC, the hematological toxicity of CBP was severe and it had some negative effects on the QOL. The administration of CBP at 5 mg.mL^-1·min^-1 by AUC may be too high for Chinese senile patients with non-small cell lung cancer.展开更多
An analytical study is presented on the modal dispersion characteristics, group velocity, and effective group, as well as the phase index of a ternary one dimensional plasma photonic crystal for an obliquely incident ...An analytical study is presented on the modal dispersion characteristics, group velocity, and effective group, as well as the phase index of a ternary one dimensional plasma photonic crystal for an obliquely incident electromagnetic wave considering the effect of collisions in plasma layers. The dispersion relation is derived by using the transfer matrix method and the boundary conditions based on electromagnetic theory. The dispersion curves are plotted for both the normal photonic band gap structure and the absorption photonic band gap structure. It is found that the increase in the angle of incidence shifts the photonic band gap toward higher frequencies. Also, the cutoff frequency is independent of collisions.展开更多
BACKGROUND Early identification of metabolic-associated fatty liver disease(MAFLD)is urgent.Atherogenic index of plasma(AIP)is a reference predictor of obesity-related diseases,but its predictive value for MAFLD remai...BACKGROUND Early identification of metabolic-associated fatty liver disease(MAFLD)is urgent.Atherogenic index of plasma(AIP)is a reference predictor of obesity-related diseases,but its predictive value for MAFLD remains unclear.No studies have reported whether its combination with waist circumference(WC)and body mass index(BMI)can improve the predictive performance for MAFLD.AIM To systematically explore the relationship between AIP and MAFLD and evaluate its predictive value for MAFLD and to pioneer a novel noninvasive predictive model combining AIP,WC,and BMI while validating its predictive performance for MAFLD.METHODS This cross-sectional study consecutively enrolled 864 participants.Multivariate logistic regression analysis and receiver operating characteristic curve were used to evaluate the relationship between AIP and MAFLD and its predictive power for MAFLD.The novel prediction model A-W-B combining AIP,WC,and BMI to predict MAFLD was established,and internal verification was completed by magnetic resonance imaging diagnosis.RESULTS Subjects with higher AIP exhibited a significantly increased risk of MAFLD,with an odds ratio of 12.420(6.008-25.675)for AIP after adjusting for various confounding factors.The area under receiver operating characteristic curve of the A-W-B model was 0.833(0.807-0.858),which was significantly higher than that of AIP,WC,and BMI(all P<0.05).Subgroup analysis illustrated that the A-W-B model had significantly higher area under receiver operating characteristic curves in female,young and nonobese subgroups(all P<0.05).The best cutoff values for the A-W-B model to predict MAFLD in males and females were 0.5932 and 0.4105,respectively.Additionally,in the validation set,the area under receiver operating characteristic curve of the A-W-B model to predict MAFLD was 0.862(0.791-0.916).The A-W-B level was strongly and positively associated with the liver proton density fat fraction(r=0.630,P<0.001)and significantly increased with the severity of MAFLD(P<0.05).CONCLUSION AIP was strongly and positively associated with the risk of MAFLD and can be a reference predictor for MAFLD.The novel prediction model A-W-B combining AIP,WC,and BMI can significantly improve the predictive ability of MAFLD and provide better services for clinical prediction and screening of MAFLD.展开更多
The (DC-GDPAU) is a DC glow discharge plasma experiment that was designed, established, and operated in the Physics Department at Ain Shams University (Egypt). The aim of this experiment is to study and improve some p...The (DC-GDPAU) is a DC glow discharge plasma experiment that was designed, established, and operated in the Physics Department at Ain Shams University (Egypt). The aim of this experiment is to study and improve some properties of a printed circuit board (PCB) by exposing it to the plasma. The device consists of cylindrical discharge chamber with movable parallel circular copper electrodes (cathode and anode) fixed inside it. The distance between them is 12 cm. This plasma experiment works in a low-pressure range (0.15 - 0.70 Torr) for Ar gas with a maximum DC power supply of 200 W. The Paschen curves and electrical plasma parameters (current, volt, power, resistance) characterized to the plasma have been measured and calculated at each cm between the two electrodes. Besides, the electron temperature and ion density are obtained at different radial distances using a double Langmuir probe. The electron temperature (<em>KT<sub>e</sub></em>) was kept stable in range 6.58 to 10.44 eV;whereas the ion density (<em>ni</em>) was in range from 0.91 × 10<sup>10</sup> cm<sup><span style="white-space:nowrap;">−</span>3</sup> to 1.79 × 10<sup>10</sup> cm<sup><span style="white-space:nowrap;">−</span>3</sup>. A digital optical microscope (800×) was employed to draw a comparison between the pre-and after effect of exposure to plasma on the shaping of the circuit layout. The experimental results show that the electrical conductivity increased after plasma exposure, also an improvement in the adhesion force in the Cu foil surface. A significant increase in the conductivity can be directly related to the position of the sample surfaces as well as to the time of exposure. This shows the importance of the obtained results in developing the PCBs manufacturing that uses in different microelectronics devices like those onboard of space vehicles.展开更多
The voltage-current properties during plasma electrolytic discharge were determined by measuring the current density and cell voltage as functions of processing time and then by mathematical transformation. Correlatio...The voltage-current properties during plasma electrolytic discharge were determined by measuring the current density and cell voltage as functions of processing time and then by mathematical transformation. Correlation between discharge I-V property and the coatings microstructure on aluminum alloy during plasma electrolytic oxidation was determined by comparing the voltage-current properties at different process stages with SEM results of the corresponding coatings. The results show that the uniform passive film corresponds to a I-V property with one critical voltage, and a compound of porous layer and sintered ceramic particles corresponds to a I-V property with two critical voltages. The growth regularity of PEO cermet coatings was also studied.展开更多
The corrosion-protective performance of plasma-polymerized (PP) coatings on pretreated aluminum substrates has been investigated by cathodic polarization curve measurement. The surface composition and electronic prope...The corrosion-protective performance of plasma-polymerized (PP) coatings on pretreated aluminum substrates has been investigated by cathodic polarization curve measurement. The surface composition and electronic properties of the pretreated and PP film coated metal surfaces were also characterized by XPS and the temperature-programmed photoelectron emission (TPPE). A PP coating was prepared on the pretreated surfaces by plasma polymerization of a mixture of tetraethoxysilane (TEOS) monomer vapor and oxygen using a 13.56MHz radiofrequency generator. The polarization curve of PP film coated samples was measured in NaCl aqueous solution. The weight loss rate calculated from the value of the corrosion current of the curve was used to estimate the protective performance of the PP film coated samples. Argon plasma treatment of the metal surface gave much better corrosion-protective performance than pretreatments such as oxidation by heating in air and diamond scratching. The XPS analysis indicated that the silicon oxide assigned to SiO2 was formed on the PP film coated surface. The TPPE analysis revealed that the electron emission characteristics for the metal surfaces pretreated only were strongly influenced by the pretreatments, while all the PP film coated samples exhibited nearly the same electron emission trend with a much decreased intensity.展开更多
Assuming that plasma particles are moving on continuous and non-differentiable curves, some dynamic properties in plasma ablation are analyzed via scale-relativity theory: the splitting of plasma plume, multi-peak str...Assuming that plasma particles are moving on continuous and non-differentiable curves, some dynamic properties in plasma ablation are analyzed via scale-relativity theory: the splitting of plasma plume, multi-peak structures, at various distances from the target surface and plasma oscillations through self-similarity. Our theoretical results are in good agreement with the experimental ones.展开更多
When we were studying the vacuum switch,we found that the vacuum diode can radiate a broadband microwave.The vacuum diode is comprised of a cathode with a trigger device and planar anode,there is not a metallic bellow...When we were studying the vacuum switch,we found that the vacuum diode can radiate a broadband microwave.The vacuum diode is comprised of a cathode with a trigger device and planar anode,there is not a metallic bellows waveguide structure in this device,so the radiation mechanism of the vacuum diode is different from the plasma filled microwave device.It is hard to completely imitate the theory of the plasma filled microwave device.This paper analyzes the breakdown process of the vacuum diode,establishes the mathematical model of the radiating microwave from the vacuum diode.Based on the analysis of the dispersion relation in the form of a refractive index,the electromagnetic waves generated in the vacuum diode will resonate.The included angle between the direction of the electromagnetic radiation and the initial motion direction of electron beam is 45 degrees.The paper isolates the electrostatic effect from the beam-plasma interaction when the electromagnetic radiation occurs.According to above analyses,the dispersion relations of radiation are obtained by solving the wave equation.The dispersion curves are also obtained based on the theoretical dispersion relations.The theoretical dispersion curves are consistent with the actual measurement time-frequency maps of the radiation.Theoretical deduction and experiments indicate that the reason for microwave radiating from the vacuum diode can be well explained by the interaction of the electron beam and magnetized plasma.展开更多
Straight plasma channels are widely used to guide relativistic intense laser pulses over several Rayleigh lengths for laser wakefield acceleration.Recently,a curved plasma channel with gradually varied curvature was s...Straight plasma channels are widely used to guide relativistic intense laser pulses over several Rayleigh lengths for laser wakefield acceleration.Recently,a curved plasma channel with gradually varied curvature was suggested to guide a fresh intense laser pulse and merge it into a straight channel for staged wakefield acceleration[Phys.Rev.Lett.120,154801(2018)].In this work,we report the generation of such a curved plasma channel from a discharged capillary.Both longitudinal and transverse density distributions of the plasma inside the channel were diagnosed by analyzing the discharging spectroscopy.Effects of the gas-filling mode,back pressure and discharging voltage on the plasma density distribution inside the specially designed capillary are studied.Experiments show that a longitudinally uniform and transversely parabolic plasma channel with a maximum channel depth of 47.5µm and length of 3 cm can be produced,which is temporally stable enough for laser guiding.Using such a plasma channel,a laser pulse with duration of 30 fs has been successfully guided along the channel with the propagation direction bent by 10.4◦.展开更多
基金a grant from a key research program of the Education Bureau of Hubei Province (D2006-02-002).
文摘To preliminarily determine the appropriate dosage of carboplatin (CBP) at AUC of 5 mg-M1^-1·min^-1 in the combination chemotherapy for Chinese senile patients with non-small cell lung cancer (NSCLC). Thirty-five Chinese senile patients with NSCLC in advanced stage (Ⅲ/Ⅳ) were given 96 cycles of combination chemotherapy. Chemotherapy schedules included Taxol+CBP, Gemzar+CBP and NVB+CBE The dose of CBP was at 5 mg.mL^-1·min^-1 of area under the concentration-time curve (AUC). Side effects and quality of life were observed before and after the chemotherapy. Myelosuppression was severe and commonly observed. Grade 3/4 of granulocytopenia was found in 47.9% (46/96) of the patients and grade 3/4 of thrombocytopenia was noted in 28.1% (27/96) of the subjects. However, other side effects were slight. The mean score of quality of life (QOL), according to the criteria of QOL for Chinese cancer patients had reduced 6.8. At 5 mg.mL^-1·min^-1 by AUC, the hematological toxicity of CBP was severe and it had some negative effects on the QOL. The administration of CBP at 5 mg.mL^-1·min^-1 by AUC may be too high for Chinese senile patients with non-small cell lung cancer.
文摘An analytical study is presented on the modal dispersion characteristics, group velocity, and effective group, as well as the phase index of a ternary one dimensional plasma photonic crystal for an obliquely incident electromagnetic wave considering the effect of collisions in plasma layers. The dispersion relation is derived by using the transfer matrix method and the boundary conditions based on electromagnetic theory. The dispersion curves are plotted for both the normal photonic band gap structure and the absorption photonic band gap structure. It is found that the increase in the angle of incidence shifts the photonic band gap toward higher frequencies. Also, the cutoff frequency is independent of collisions.
基金This study was approved by the Clinical Research Ethics Committee of China-Japan Friendship Hospital(2018-110-K79-1).
文摘BACKGROUND Early identification of metabolic-associated fatty liver disease(MAFLD)is urgent.Atherogenic index of plasma(AIP)is a reference predictor of obesity-related diseases,but its predictive value for MAFLD remains unclear.No studies have reported whether its combination with waist circumference(WC)and body mass index(BMI)can improve the predictive performance for MAFLD.AIM To systematically explore the relationship between AIP and MAFLD and evaluate its predictive value for MAFLD and to pioneer a novel noninvasive predictive model combining AIP,WC,and BMI while validating its predictive performance for MAFLD.METHODS This cross-sectional study consecutively enrolled 864 participants.Multivariate logistic regression analysis and receiver operating characteristic curve were used to evaluate the relationship between AIP and MAFLD and its predictive power for MAFLD.The novel prediction model A-W-B combining AIP,WC,and BMI to predict MAFLD was established,and internal verification was completed by magnetic resonance imaging diagnosis.RESULTS Subjects with higher AIP exhibited a significantly increased risk of MAFLD,with an odds ratio of 12.420(6.008-25.675)for AIP after adjusting for various confounding factors.The area under receiver operating characteristic curve of the A-W-B model was 0.833(0.807-0.858),which was significantly higher than that of AIP,WC,and BMI(all P<0.05).Subgroup analysis illustrated that the A-W-B model had significantly higher area under receiver operating characteristic curves in female,young and nonobese subgroups(all P<0.05).The best cutoff values for the A-W-B model to predict MAFLD in males and females were 0.5932 and 0.4105,respectively.Additionally,in the validation set,the area under receiver operating characteristic curve of the A-W-B model to predict MAFLD was 0.862(0.791-0.916).The A-W-B level was strongly and positively associated with the liver proton density fat fraction(r=0.630,P<0.001)and significantly increased with the severity of MAFLD(P<0.05).CONCLUSION AIP was strongly and positively associated with the risk of MAFLD and can be a reference predictor for MAFLD.The novel prediction model A-W-B combining AIP,WC,and BMI can significantly improve the predictive ability of MAFLD and provide better services for clinical prediction and screening of MAFLD.
文摘The (DC-GDPAU) is a DC glow discharge plasma experiment that was designed, established, and operated in the Physics Department at Ain Shams University (Egypt). The aim of this experiment is to study and improve some properties of a printed circuit board (PCB) by exposing it to the plasma. The device consists of cylindrical discharge chamber with movable parallel circular copper electrodes (cathode and anode) fixed inside it. The distance between them is 12 cm. This plasma experiment works in a low-pressure range (0.15 - 0.70 Torr) for Ar gas with a maximum DC power supply of 200 W. The Paschen curves and electrical plasma parameters (current, volt, power, resistance) characterized to the plasma have been measured and calculated at each cm between the two electrodes. Besides, the electron temperature and ion density are obtained at different radial distances using a double Langmuir probe. The electron temperature (<em>KT<sub>e</sub></em>) was kept stable in range 6.58 to 10.44 eV;whereas the ion density (<em>ni</em>) was in range from 0.91 × 10<sup>10</sup> cm<sup><span style="white-space:nowrap;">−</span>3</sup> to 1.79 × 10<sup>10</sup> cm<sup><span style="white-space:nowrap;">−</span>3</sup>. A digital optical microscope (800×) was employed to draw a comparison between the pre-and after effect of exposure to plasma on the shaping of the circuit layout. The experimental results show that the electrical conductivity increased after plasma exposure, also an improvement in the adhesion force in the Cu foil surface. A significant increase in the conductivity can be directly related to the position of the sample surfaces as well as to the time of exposure. This shows the importance of the obtained results in developing the PCBs manufacturing that uses in different microelectronics devices like those onboard of space vehicles.
基金Project(10572141) supported by the National Natural Science Foundation of China
文摘The voltage-current properties during plasma electrolytic discharge were determined by measuring the current density and cell voltage as functions of processing time and then by mathematical transformation. Correlation between discharge I-V property and the coatings microstructure on aluminum alloy during plasma electrolytic oxidation was determined by comparing the voltage-current properties at different process stages with SEM results of the corresponding coatings. The results show that the uniform passive film corresponds to a I-V property with one critical voltage, and a compound of porous layer and sintered ceramic particles corresponds to a I-V property with two critical voltages. The growth regularity of PEO cermet coatings was also studied.
文摘The corrosion-protective performance of plasma-polymerized (PP) coatings on pretreated aluminum substrates has been investigated by cathodic polarization curve measurement. The surface composition and electronic properties of the pretreated and PP film coated metal surfaces were also characterized by XPS and the temperature-programmed photoelectron emission (TPPE). A PP coating was prepared on the pretreated surfaces by plasma polymerization of a mixture of tetraethoxysilane (TEOS) monomer vapor and oxygen using a 13.56MHz radiofrequency generator. The polarization curve of PP film coated samples was measured in NaCl aqueous solution. The weight loss rate calculated from the value of the corrosion current of the curve was used to estimate the protective performance of the PP film coated samples. Argon plasma treatment of the metal surface gave much better corrosion-protective performance than pretreatments such as oxidation by heating in air and diamond scratching. The XPS analysis indicated that the silicon oxide assigned to SiO2 was formed on the PP film coated surface. The TPPE analysis revealed that the electron emission characteristics for the metal surfaces pretreated only were strongly influenced by the pretreatments, while all the PP film coated samples exhibited nearly the same electron emission trend with a much decreased intensity.
基金support of Posdru Cuantumdoc“Doctoral Studies for European Performances in Research and Inovation”ID79407 project funded by the European Social Found and Romanian Government.
文摘Assuming that plasma particles are moving on continuous and non-differentiable curves, some dynamic properties in plasma ablation are analyzed via scale-relativity theory: the splitting of plasma plume, multi-peak structures, at various distances from the target surface and plasma oscillations through self-similarity. Our theoretical results are in good agreement with the experimental ones.
基金Supported by National Nature Science Foundation of China(No.11075123)the Young Scientists Fund of Nature Science Foundation of China(No.51207171)
文摘When we were studying the vacuum switch,we found that the vacuum diode can radiate a broadband microwave.The vacuum diode is comprised of a cathode with a trigger device and planar anode,there is not a metallic bellows waveguide structure in this device,so the radiation mechanism of the vacuum diode is different from the plasma filled microwave device.It is hard to completely imitate the theory of the plasma filled microwave device.This paper analyzes the breakdown process of the vacuum diode,establishes the mathematical model of the radiating microwave from the vacuum diode.Based on the analysis of the dispersion relation in the form of a refractive index,the electromagnetic waves generated in the vacuum diode will resonate.The included angle between the direction of the electromagnetic radiation and the initial motion direction of electron beam is 45 degrees.The paper isolates the electrostatic effect from the beam-plasma interaction when the electromagnetic radiation occurs.According to above analyses,the dispersion relations of radiation are obtained by solving the wave equation.The dispersion curves are also obtained based on the theoretical dispersion relations.The theoretical dispersion curves are consistent with the actual measurement time-frequency maps of the radiation.Theoretical deduction and experiments indicate that the reason for microwave radiating from the vacuum diode can be well explained by the interaction of the electron beam and magnetized plasma.
文摘目的探讨肾小管及肾小球相关标志物在2型糖尿病(type 2 diabetes mellitus,T2DM)患者不同肾损伤阶段的诊断价值。方法选取于2018年4月1日至2019年10月31日入住首都医科大学附属北京同仁医院内分泌科的T2DM患者272例,完善临床生化指标及尿蛋白四项:尿微量白蛋白/肌酐(urinary albumin to creatinine ratio,ACR)、α1-微球蛋白/肌酐(urinary α1-microglobulin to creatinine ratio,UA1CR)、免疫球蛋白G/肌酐(urinary immunoglobulin G to creatinine ratio,UIGG)、转铁蛋白/肌酐(urinary transferrin to creatinine ratio,UTRF);进行眼底照相、核医学99mTc-EC检测肾有效血浆流量(effective renal plasma flow,ERPF)和99mTc-DTPA检测肾小球滤过率(glomerular filtration rate,GFR)。根据ACR和眼底检查结果分为4组:正常蛋白尿无糖尿病视网膜病变(diabetic retinopathy,DR)132例,即对照组(ACR≤30 mg/g);正常蛋白尿合并DR 32例,为糖尿病肾病(diabetic kidney disease,DKD)前期组;微量蛋白尿组78例(30<ACR≤300 mg/g)和大量蛋白尿组30例(ACR>300 mg/g)。比较四组间尿蛋白四项和ERPF、GFR的水平,通过受试者工作特征(receiver operating characteristic,ROC)曲线评价上述各指标在不同肾损伤阶段的诊断价值。结果尿蛋白四项和ERPF、GFR的水平在不同组间差异有统计学意义(P<0.05)。在尿蛋白正常组中,DR组中肾小管功能标志物UA1CR较对照组明显升高(P<0.01);肾小球功能标志物ACR、UTRF和GFR在两组间差异无统计学意义(P>0.05),DR组UIGG较对照组升高(P<0.01)。在微量蛋白尿组和大量蛋白尿组,尿蛋白四项随肾损伤程度增加而增加,而ERPF和GFR随肾损伤程度增加而降低。ROC曲线分析显示,在尿蛋白排出正常的T2DM患者中合并DR组中肾小管功能标志物UA1CR和ERPF的曲线下面积(area under the curve,AUC)分别为68.2%(P<0.01)和60.5%(P<0.05),而肾小球功能标志物ACR和GFR的AUC均小于60%,差异无统计学意义(P>0.05)。尿蛋白四项及GFR在微量和大量蛋白尿组的AUC均大于60%(P<0.05),ERPF在大量蛋白尿组AUC为67.2%(P<0.05)。结论T2DM极早期微血管改变即ACR正常仅有DR时,肾小管标志物UA1CR先于肾小球标志物ACR和GFR发生变化。肾损伤早期,肾小管标志物诊断效能优于肾小球;肾损伤后期,肾小球标志物诊断效能优于肾小管。提示DKD肾小管功能的改变可能早于肾小球。
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.11991074 and 12225505)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant Nos.XDA25010500,XDA25050000 and XDA17040504).
文摘Straight plasma channels are widely used to guide relativistic intense laser pulses over several Rayleigh lengths for laser wakefield acceleration.Recently,a curved plasma channel with gradually varied curvature was suggested to guide a fresh intense laser pulse and merge it into a straight channel for staged wakefield acceleration[Phys.Rev.Lett.120,154801(2018)].In this work,we report the generation of such a curved plasma channel from a discharged capillary.Both longitudinal and transverse density distributions of the plasma inside the channel were diagnosed by analyzing the discharging spectroscopy.Effects of the gas-filling mode,back pressure and discharging voltage on the plasma density distribution inside the specially designed capillary are studied.Experiments show that a longitudinally uniform and transversely parabolic plasma channel with a maximum channel depth of 47.5µm and length of 3 cm can be produced,which is temporally stable enough for laser guiding.Using such a plasma channel,a laser pulse with duration of 30 fs has been successfully guided along the channel with the propagation direction bent by 10.4◦.