Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In...Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.展开更多
The Zhongjiang gas field is a typical large gas field in terrigenous strata of the Western Sichuan Depression.It remains debatable which member of the Upper Triassic Xujiahe Formation served as the source rocks and ho...The Zhongjiang gas field is a typical large gas field in terrigenous strata of the Western Sichuan Depression.It remains debatable which member of the Upper Triassic Xujiahe Formation served as the source rocks and how significant the member contributed to the gas accumulations in the Zhongjiang gas field.In this study,we analyzed the essential characteristics of the Lower Jurassic source rocks and the geochemical features of light hydrocarbons in natural gas from the 2nd(T_(3)χ^(2))and 4th members(T_(3)χ^(4))of the Upper Triassic Xujiahe Formation(T_(3)χ),as well as the Middle Jurassic Shaximiao(J_(2)s)and Qianfoya(J_(2)q)formations.Based on this,we explored the sources of the natural gas in the Zhongjiang gas field and determined the natural gas migration patterns and their effects on the properties of light hydrocarbons in the natural gas.The results indicate that the Lower Jurassic lacustrine source rocks of the Zhongjiang gas field contain humic organic matter,with vitrinite reflectance(R_(0))values ranging from 0.86%to 0.98%.Samples meeting the criterion for effective source rocks[total organic carbon(TOC)content≥0.75%]exhibited an average TOC content of merely 1.02%,suggesting significantly lower hydrocarbon generation potential than source rocks in the underlying T3x,which show higher thermal maturity and TOC contents.For natural gas samples from T_(3)χ^(2),T_(3)χ^(4),J_(2)s,and J_(2)q reservoirs,their C_(5-7)iso-alkane content was significantly higher than their n-alkane content,and their methylcyclohexane(MCH)index ranged from 59.0%to 77.3%,indicating the predominance of methylcyclohexane in C_(7)light hydrocarbons.As indicated by the origin identification and gas-source correlation based on the geochemical features of light hydrocarbons,the natural gas in the Zhongjiang gas field is typical coal-derived gas.The gas from the primary pay zone of the Shaximiao Formation,with significantly high K_(1),(P_(2)+N_(2))/C_(7),and P_(3)/C_(7)values,predominantly originated from the 5th member of the T3x and migrated in the free phase,with a small amount possibly sourced from the Lower Jurassic source rocks.The dissolution and adsorption during gas migration led to a decrease in the aromatic content in C_(6-7)light hydrocarbons and an increase in the isoheptane values.Therefore,their effects must be considered when determining the gas origin and thermal maturity based on the aromatic content in C_(6-7) light hydrocarbons and iso-heptane values.展开更多
We have studied laser-produced plasma based on mass-limited thin-film Gd targets for beyond the current extreme ultraviolet(EUV)light source of 13.5 nm wavelength based on tin.The influences of the laser intensity on ...We have studied laser-produced plasma based on mass-limited thin-film Gd targets for beyond the current extreme ultraviolet(EUV)light source of 13.5 nm wavelength based on tin.The influences of the laser intensity on the emission spectra centered around 6.7 nm from thin-film Gd targets were first investigated.It is found that the conversion efficiency of the produced plasma is saturated when the laser intensity goes beyond 2×10^(11)W cm^(-2).We have systematically compared the emission spectra of the laser-produced plasma with the changes in the thicknesses of the thin-film Gd targets.It is proved that a minimum-mass target with a thickness of 400 nm is sufficient to provide the maximum conversion efficiency,which also implies that this thickness is the ablation depth for the targets.These findings should be helpful in the exploration of next-generation EUV sources,as the thin-film Gd targets will reduce the debris during the plasma generation process compared with the bulk targets.展开更多
The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized pl...The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized plasma is extended in the presence of an ion–neutral collisional force and ionization source. The effects of electron nonextensive distribution, ionization frequency, ion–neutral collision, magnetic field angle and ion temperature on the Bohm criterion of the plasma sheath are numerically analyzed. The fluid equations are solved numerically in the plasma–wall transition region using a modified Bohm criterion as the boundary condition. The plasma sheath properties such as charged particle density, floating sheath potential and thickness are thoroughly investigated under different kinds of ion source terms, contributions of collisions, and magnetic fields. The results show that the effect of the ion source term on the properties of atmosphericpressure collisional plasma sheath is significant. As the ionization frequency increases, the Mach number of the Bohm criterion decreases and the range of possible values narrows. When the ion source is considered, the space charge density increases, the sheath potential drops more rapidly,and the sheath thickness becomes narrower. In addition, ion–neutral collision, magnetic field angle and ion temperature also significantly affect the sheath potential profile and sheath thickness.展开更多
A scheme to improve the quality in ghost imaging(GI)by controlling the bandwidth of light source(BCGI)is proposed.The theoretical and numerical results show that the reconstruction result with high quality can be obta...A scheme to improve the quality in ghost imaging(GI)by controlling the bandwidth of light source(BCGI)is proposed.The theoretical and numerical results show that the reconstruction result with high quality can be obtained by adjusting the bandwidth range of the light source appropriately,and the selection criterion of the bandwidth is analyzed by the power distribution of the imaging target.A proof-of-principle experiment is implemented to verify the theoretical and numerical results.In addition,the BCGI also presents better anti-noise performance when compared with some popular GI methods.展开更多
This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagat...This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagate in the core region,and it decays sharply outside the core.The power absorption is lower and steeper in radius for blue-core mode.Regarding the effects of antenna geometry for blue-core mode,it shows that half helix antenna yields the strongest wave field and power absorption,while loop antenna yields the lowest.Moreover,near axis,for antennas with m=+1,the wave field increases with axial distance.In the core region,the wave number approaches to a saturation value at much lower frequency for non-blue-core mode compared to blue-core mode.The total loading resistance is much lower for blue-core mode.These findings are valuable to understanding the physics of blue-core helicon discharge and optimizing the experimental performance of blue-core helicon plasma sources for applications such as space propulsion and material treatment.展开更多
The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results s...The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results show that plasma exists inside the cavity when the sheath inside the hollow electrode hole is fully collapsed, which is an essential condition for the plasma density enhancement outside hollow electrodes. In addition, the existence of the electron density peak at the orifice is generated via the hollow cathode effect(HCE), which plays an important role in the density enhancement. It is also found that the radial width of bulk plasma at the orifice affects the magnitude of the density enhancement, and narrow radial plasma bulk width at the orifice is not beneficial to obtain high-density plasma outside hollow electrodes.Higher electron density at the orifice, combined with larger radial plasma bulk width at the orifice,causes higher electron density outside hollow electrodes. The results also imply that the HCE strength inside the cavity cannot be determined by the magnitude of the electron density outside hollow electrodes.展开更多
Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading t...Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading to significant energy consumption and environmental pollution.Non-thermal plasma(NTP) is a promising alternative approach to ammonia synthesis at low temperature and atmospheric pressure.In this study,the synergistic effect of nanosecond pulsed dielectric barrier discharge(np-DBD) and Ni-MOF-74 catalyst was investigated in ammonia synthesis by utilizing nitrogen and hydrogen as feedstock.The results demonstrated that the plasma catalytic-synthesis process parameters play a crucial role in the synthesis process of ammonia.The highest ammonia synthesis rate of 5145.16 μmol·g^(-1)·h^(-1)with an energy efficiency of 1.27 g·kWh^(-1)was observed in the presence of the Ni-MOF-74 catalyst,which was3.7 times higher than that without Ni-MOF-74 catalyst.The synergistic effect of Ni-MOF-74catalyst and nanosecond pulsed plasma was explored by in-situ plasma discharge diagnostics.展开更多
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k...Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.展开更多
We tested 288 pieces of the polished cabochon jadeite-jade with high quality green and smooth surfaces using the colorimeter Color i5 based on the CIE 1976 L*a*b* uniform color space. The color changes after altern...We tested 288 pieces of the polished cabochon jadeite-jade with high quality green and smooth surfaces using the colorimeter Color i5 based on the CIE 1976 L*a*b* uniform color space. The color changes after alternating three CIE standard light sources D65, A and CWF were compared, and the degree of metamerism was evaluated. The results show that the CIE standard light sources D65, A and CWF increase the chroma of green and turn bluish green into vivid green, which are similar or to nearly colorless and transparent glass-like samples with fine textures. When the three light sources were individually alternated, the lightness of the jadeite-jades showed little change, but the tone changed significantly. Metamerism occurred only in 3 pairs among the 16 samples that were selected by cluster analysis for quality, and the metamerism colors were highly consistent of L*D65∈(43.47, 46.75), C*D65∈(65.20, 68.80) and ho*D65∈(138.10, 140.23). We can conclude that the jadeite-jade green gradually turns to blue when the color temperature of the light source increases. But when considering both the light sources and the samples, D65 is more suitable to be the light source of jadeite-jade green when compared with the light sources CWF and A. Compared with the CIE standard green and high chroma green, high-quality jadeite-jade green has a slight yellow tone, low lightness and high chroma. The special metamerism index decreased to 1 when the light source alternated among D65, A and CWF. Therefore, the color of jadeite-jade green might be slightly influenced by alternating of the light sources.展开更多
BACKGROUND Conventionally, the low luminous intensity, low image resolution, and difficulty in operation have been reported with the ultrathin endoscope. However, it has markedly advanced recently. The improvement of ...BACKGROUND Conventionally, the low luminous intensity, low image resolution, and difficulty in operation have been reported with the ultrathin endoscope. However, it has markedly advanced recently. The improvement of the diagnostic ability is expected.AIM To compare the early gastric cancer diagnostic ability of an ultrathin endoscope loaded with a laser light source and that of the conventional endoscope.METHODS The target subjects were 375 consecutive patients who underwent endoscopy at our hospital for post-endoscopic submucosal dissection follow-up of gastric cancer from January to August 2018. During endoscopy, the ultrathin endoscope was used in 140 patients(37.3%), and the conventional endoscope was used in235 patients(62.7%). Patient background was adjusted using the propensity score matching method, and gastric cancer detection ability was evaluated in the two groups.RESULTS The gastric cancer detection rate was 7.8% in the ultrathin endoscope group and7.0% in the conventional endoscope group, and the mean intragastric observation time was 4.1 ± 1.7 min in the ultrathin endoscope group and 4.1 ± 1.9 min in the conventional endoscope group, showing no significant differences between the groups. Moreover, the biopsy implementation rate was 31.8% in the ultrathin endoscope group and 41.1% in the conventional endoscope group, and the biopsy prediction rate was 17.9% and 13.2%, respectively, showing no significant differences between the groups.CONCLUSION The gastric cancer diagnostic ability of the ultrathin endoscope loaded with a laser light source was comparable to that of the conventional endoscope. The observation time was also comparable. Thus, endoscopy using the ultrathin endoscope loaded with the laser light source would be the first option in screening examinations of gastric cancer due to its low invasion.展开更多
A method based on multiple images captured under different light sources at different incident angles was developed to recognize the coal density range in this study.The innovation is that two new images were construc...A method based on multiple images captured under different light sources at different incident angles was developed to recognize the coal density range in this study.The innovation is that two new images were constructed based on images captured under four single light sources.Reconstruction image 1 was constructed by fusing greyscale versions of the original images into one image,and Reconstruction image2 was constructed based on the differences between the images captured under the different light sources.Subsequently,the four original images and two reconstructed images were input into the convolutional neural network AlexNet to recognize the density range in three cases:-1.5(clean coal) and+1.5 g/cm^(3)(non-clean coal);-1.8(non-gangue) and+1.8 g/cm^(3)(gangue);-1.5(clean coal),1.5-1.8(middlings),and+1.8 g/cm^(3)(gangue).The results show the following:(1) The reconstructed images,especially Reconstruction image 2,can effectively improve the recognition accuracy for the coal density range compared with images captured under single light source.(2) The recognition accuracies for gangue and non-gangue,clean coal and non-clean coal,and clean coal,middlings,and gangue reached88.44%,86.72% and 77.08%,respectively.(3) The recognition accuracy increases as the density moves further away from the boundary density.展开更多
An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature ...An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones.展开更多
Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron dens...Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA.展开更多
The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light so...The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light source can be integrated with a time delay integration charge-coupled device (TDI CCD ) to capture the images of moving objects and facilitate inspection of the surface quality of tin steel strips. On-site application show the effectiveness of the TDI camera with the adaptive illumination light source in detecting the surface defects on tin steel strips of three different materials and with different tin coating weights.展开更多
This paper deals with the topic of RF plasma sources and their application inhigh-power neutral beam heating systems for nuclear fusion devices. RF sources represent aninteresting alternative to the conventional arc d...This paper deals with the topic of RF plasma sources and their application inhigh-power neutral beam heating systems for nuclear fusion devices. RF sources represent aninteresting alternative to the conventional arc discharge sources. Due to the absence of hotfilaments they exhibit an inherent simplicity both in mechanical and electrical aspects andconsequently offer advantages in terms of cost savings, gain in availability and reliability andreduced maintenance. This renders the RF plasma source attractive for any long pulse (> 10 sec) NBIsystem and in particular for the ITER NBI system. The latter, however, requires that the RF plasmasource is also capable of delivering negative rather than positive hydrogen ions. In the first partof the paper the types, characteristics and operation experience of RF plasma sources for positiveions in operation are described. The second part is devoted to the development for ITER NBI: thebasic requirements, physics and technology issues and the present status are discussed.展开更多
A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-fie...A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications.展开更多
Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to it...Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to its high electron emission current. An indirectly heated oxide coated cathode plasma source has been constructed on a linear magnetized plasma device. The electron emission current density can reach 2 A/cm2 to 6 A/cm2 in pulsed mode within pulse length 5-20 ms. A 10 cm diameter, 2 m long plasma column with density 10is m-3 to 1019 m3 and electron temperature Te --~ 3-7 eV is produced. The spatial uniformity of the emission ability is less than 4% and the discharge reproducibility is better than 97%. With a wide range of the plasma parameters, this kind of plasma source provides great flexibility for many basic plasma investigations. The detail of construction and initial characterization of oxide coated cathode are described in this paper.展开更多
Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal th...Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal the inside interaction between the plasma,magnetic field and microwave electric field.From the diagnosing result it can be found that the plasma density distribution is controlled by the plasma generation and electron loss volumes associated with the magnetic field and microwave power level.Based on the cold plasma hypothesis and diagnosing result,the microwave electric field intensity distribution in the plasma is calculated.The result shows that the plasma will significantly change the distribution of the microwave electric field intensity to form a bow shape.From the boundary region of the shape to the center,the electric field intensity varies from higher to lower and the diagnosed density inversely changes.If the bow and its inside lower electric field intensity region are close to the screen grid,the performance of ion beam extracting will be better.The study can provide useful information for the creating of 10 cm ECR ion source and understanding its mechanism.展开更多
By utilization of different excitation power sources, linear plasma sources can be differentiated into DC, RF, VHF, microwave and dual frequency types. Through installing several linear plasma sources in parallel or a...By utilization of different excitation power sources, linear plasma sources can be differentiated into DC, RF, VHF, microwave and dual frequency types. Through installing several linear plasma sources in parallel or adopting the so-called roll-to-roll (air-to-air) process, scale uniform linear plasma sources were realized and successfully applied to the deposition of large area uniform dielectric thin films, Furthermore, the magnetic field system can effectively reduce the recombination losses on the wall of the vacuum chamber and enhance the plasma density. Linear plasma sources with approximately one square meter deposition area with the plasma density of 1011 cm 3 have been developed, some of which have been used for the deposition of dielectric layers and large area plasma etching.展开更多
基金supported by Bhabha Atomic Research Centre, Department of Atomic Energy, Government of IndiaDepartment of Atomic Energy, Government of India for financial assistance under DAE Doctoral Fellowship Scheme-2018。
文摘Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.
基金funded by the National Natural Science Foundation of China(No.42172149,No.U2244209)the SINOPEC Science and Technology Project(No.P22132,No.P21077-1).
文摘The Zhongjiang gas field is a typical large gas field in terrigenous strata of the Western Sichuan Depression.It remains debatable which member of the Upper Triassic Xujiahe Formation served as the source rocks and how significant the member contributed to the gas accumulations in the Zhongjiang gas field.In this study,we analyzed the essential characteristics of the Lower Jurassic source rocks and the geochemical features of light hydrocarbons in natural gas from the 2nd(T_(3)χ^(2))and 4th members(T_(3)χ^(4))of the Upper Triassic Xujiahe Formation(T_(3)χ),as well as the Middle Jurassic Shaximiao(J_(2)s)and Qianfoya(J_(2)q)formations.Based on this,we explored the sources of the natural gas in the Zhongjiang gas field and determined the natural gas migration patterns and their effects on the properties of light hydrocarbons in the natural gas.The results indicate that the Lower Jurassic lacustrine source rocks of the Zhongjiang gas field contain humic organic matter,with vitrinite reflectance(R_(0))values ranging from 0.86%to 0.98%.Samples meeting the criterion for effective source rocks[total organic carbon(TOC)content≥0.75%]exhibited an average TOC content of merely 1.02%,suggesting significantly lower hydrocarbon generation potential than source rocks in the underlying T3x,which show higher thermal maturity and TOC contents.For natural gas samples from T_(3)χ^(2),T_(3)χ^(4),J_(2)s,and J_(2)q reservoirs,their C_(5-7)iso-alkane content was significantly higher than their n-alkane content,and their methylcyclohexane(MCH)index ranged from 59.0%to 77.3%,indicating the predominance of methylcyclohexane in C_(7)light hydrocarbons.As indicated by the origin identification and gas-source correlation based on the geochemical features of light hydrocarbons,the natural gas in the Zhongjiang gas field is typical coal-derived gas.The gas from the primary pay zone of the Shaximiao Formation,with significantly high K_(1),(P_(2)+N_(2))/C_(7),and P_(3)/C_(7)values,predominantly originated from the 5th member of the T3x and migrated in the free phase,with a small amount possibly sourced from the Lower Jurassic source rocks.The dissolution and adsorption during gas migration led to a decrease in the aromatic content in C_(6-7)light hydrocarbons and an increase in the isoheptane values.Therefore,their effects must be considered when determining the gas origin and thermal maturity based on the aromatic content in C_(6-7) light hydrocarbons and iso-heptane values.
基金supported by National Natural Science Foundation of China(Nos.61427812,61805118,12104216 and 12241403)the Natural Science Foundation of Jiangsu Province of China(Nos.BK20192006,BK20180056 and BK20200307)。
文摘We have studied laser-produced plasma based on mass-limited thin-film Gd targets for beyond the current extreme ultraviolet(EUV)light source of 13.5 nm wavelength based on tin.The influences of the laser intensity on the emission spectra centered around 6.7 nm from thin-film Gd targets were first investigated.It is found that the conversion efficiency of the produced plasma is saturated when the laser intensity goes beyond 2×10^(11)W cm^(-2).We have systematically compared the emission spectra of the laser-produced plasma with the changes in the thicknesses of the thin-film Gd targets.It is proved that a minimum-mass target with a thickness of 400 nm is sufficient to provide the maximum conversion efficiency,which also implies that this thickness is the ablation depth for the targets.These findings should be helpful in the exploration of next-generation EUV sources,as the thin-film Gd targets will reduce the debris during the plasma generation process compared with the bulk targets.
基金supported by National Natural Science Foundation of China(Nos.11975062,11605021 and 11975088)the China Postdoctoral Science Foundation(No.2017M621120)。
文摘The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized plasma is extended in the presence of an ion–neutral collisional force and ionization source. The effects of electron nonextensive distribution, ionization frequency, ion–neutral collision, magnetic field angle and ion temperature on the Bohm criterion of the plasma sheath are numerically analyzed. The fluid equations are solved numerically in the plasma–wall transition region using a modified Bohm criterion as the boundary condition. The plasma sheath properties such as charged particle density, floating sheath potential and thickness are thoroughly investigated under different kinds of ion source terms, contributions of collisions, and magnetic fields. The results show that the effect of the ion source term on the properties of atmosphericpressure collisional plasma sheath is significant. As the ionization frequency increases, the Mach number of the Bohm criterion decreases and the range of possible values narrows. When the ion source is considered, the space charge density increases, the sheath potential drops more rapidly,and the sheath thickness becomes narrower. In addition, ion–neutral collision, magnetic field angle and ion temperature also significantly affect the sheath potential profile and sheath thickness.
基金the National Natural Science Foundation of China(Grant Nos.61871431,61971184,and 62001162).
文摘A scheme to improve the quality in ghost imaging(GI)by controlling the bandwidth of light source(BCGI)is proposed.The theoretical and numerical results show that the reconstruction result with high quality can be obtained by adjusting the bandwidth range of the light source appropriately,and the selection criterion of the bandwidth is analyzed by the power distribution of the imaging target.A proof-of-principle experiment is implemented to verify the theoretical and numerical results.In addition,the BCGI also presents better anti-noise performance when compared with some popular GI methods.
基金Project supported by the National Natural Science Foundation of China(Grant No.92271113)the Fundamental Research Funds for the Central Universities(Grant No.2022CDJQY-003)+1 种基金Chongqing Entrepreneurship and Innovation Support Program for Overseas Returnees(Grant No.CX2022004)the Fund from Shanghai Engineering Research Center of Space Engine(Grant No.17DZ2280800).
文摘This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagate in the core region,and it decays sharply outside the core.The power absorption is lower and steeper in radius for blue-core mode.Regarding the effects of antenna geometry for blue-core mode,it shows that half helix antenna yields the strongest wave field and power absorption,while loop antenna yields the lowest.Moreover,near axis,for antennas with m=+1,the wave field increases with axial distance.In the core region,the wave number approaches to a saturation value at much lower frequency for non-blue-core mode compared to blue-core mode.The total loading resistance is much lower for blue-core mode.These findings are valuable to understanding the physics of blue-core helicon discharge and optimizing the experimental performance of blue-core helicon plasma sources for applications such as space propulsion and material treatment.
文摘The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results show that plasma exists inside the cavity when the sheath inside the hollow electrode hole is fully collapsed, which is an essential condition for the plasma density enhancement outside hollow electrodes. In addition, the existence of the electron density peak at the orifice is generated via the hollow cathode effect(HCE), which plays an important role in the density enhancement. It is also found that the radial width of bulk plasma at the orifice affects the magnitude of the density enhancement, and narrow radial plasma bulk width at the orifice is not beneficial to obtain high-density plasma outside hollow electrodes.Higher electron density at the orifice, combined with larger radial plasma bulk width at the orifice,causes higher electron density outside hollow electrodes. The results also imply that the HCE strength inside the cavity cannot be determined by the magnitude of the electron density outside hollow electrodes.
基金the financial support from the Beijing Municipal Natural Science Foundation (No. 1242015)National Undergraduate Innovation and Entrepreneurship Training Program of China (No. 202310015019)Discipline Construction of Material Science and Engineering(Nos. 21090122014 and 21090123007)。
文摘Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading to significant energy consumption and environmental pollution.Non-thermal plasma(NTP) is a promising alternative approach to ammonia synthesis at low temperature and atmospheric pressure.In this study,the synergistic effect of nanosecond pulsed dielectric barrier discharge(np-DBD) and Ni-MOF-74 catalyst was investigated in ammonia synthesis by utilizing nitrogen and hydrogen as feedstock.The results demonstrated that the plasma catalytic-synthesis process parameters play a crucial role in the synthesis process of ammonia.The highest ammonia synthesis rate of 5145.16 μmol·g^(-1)·h^(-1)with an energy efficiency of 1.27 g·kWh^(-1)was observed in the presence of the Ni-MOF-74 catalyst,which was3.7 times higher than that without Ni-MOF-74 catalyst.The synergistic effect of Ni-MOF-74catalyst and nanosecond pulsed plasma was explored by in-situ plasma discharge diagnostics.
基金supported by the National Key Research&Development Program of China,Nos.2021YFC2501205(to YC),2022YFC24069004(to JL)the STI2030-Major Project,Nos.2021ZD0201101(to YC),2022ZD0211800(to YH)+2 种基金the National Natural Science Foundation of China(Major International Joint Research Project),No.82020108013(to YH)the Sino-German Center for Research Promotion,No.M-0759(to YH)a grant from Beijing Municipal Science&Technology Commission(Beijing Brain Initiative),No.Z201100005520018(to JL)。
文摘Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.
基金financial support by "the Fundamental Research Funds for the Central Universities"
文摘We tested 288 pieces of the polished cabochon jadeite-jade with high quality green and smooth surfaces using the colorimeter Color i5 based on the CIE 1976 L*a*b* uniform color space. The color changes after alternating three CIE standard light sources D65, A and CWF were compared, and the degree of metamerism was evaluated. The results show that the CIE standard light sources D65, A and CWF increase the chroma of green and turn bluish green into vivid green, which are similar or to nearly colorless and transparent glass-like samples with fine textures. When the three light sources were individually alternated, the lightness of the jadeite-jades showed little change, but the tone changed significantly. Metamerism occurred only in 3 pairs among the 16 samples that were selected by cluster analysis for quality, and the metamerism colors were highly consistent of L*D65∈(43.47, 46.75), C*D65∈(65.20, 68.80) and ho*D65∈(138.10, 140.23). We can conclude that the jadeite-jade green gradually turns to blue when the color temperature of the light source increases. But when considering both the light sources and the samples, D65 is more suitable to be the light source of jadeite-jade green when compared with the light sources CWF and A. Compared with the CIE standard green and high chroma green, high-quality jadeite-jade green has a slight yellow tone, low lightness and high chroma. The special metamerism index decreased to 1 when the light source alternated among D65, A and CWF. Therefore, the color of jadeite-jade green might be slightly influenced by alternating of the light sources.
文摘BACKGROUND Conventionally, the low luminous intensity, low image resolution, and difficulty in operation have been reported with the ultrathin endoscope. However, it has markedly advanced recently. The improvement of the diagnostic ability is expected.AIM To compare the early gastric cancer diagnostic ability of an ultrathin endoscope loaded with a laser light source and that of the conventional endoscope.METHODS The target subjects were 375 consecutive patients who underwent endoscopy at our hospital for post-endoscopic submucosal dissection follow-up of gastric cancer from January to August 2018. During endoscopy, the ultrathin endoscope was used in 140 patients(37.3%), and the conventional endoscope was used in235 patients(62.7%). Patient background was adjusted using the propensity score matching method, and gastric cancer detection ability was evaluated in the two groups.RESULTS The gastric cancer detection rate was 7.8% in the ultrathin endoscope group and7.0% in the conventional endoscope group, and the mean intragastric observation time was 4.1 ± 1.7 min in the ultrathin endoscope group and 4.1 ± 1.9 min in the conventional endoscope group, showing no significant differences between the groups. Moreover, the biopsy implementation rate was 31.8% in the ultrathin endoscope group and 41.1% in the conventional endoscope group, and the biopsy prediction rate was 17.9% and 13.2%, respectively, showing no significant differences between the groups.CONCLUSION The gastric cancer diagnostic ability of the ultrathin endoscope loaded with a laser light source was comparable to that of the conventional endoscope. The observation time was also comparable. Thus, endoscopy using the ultrathin endoscope loaded with the laser light source would be the first option in screening examinations of gastric cancer due to its low invasion.
文摘A method based on multiple images captured under different light sources at different incident angles was developed to recognize the coal density range in this study.The innovation is that two new images were constructed based on images captured under four single light sources.Reconstruction image 1 was constructed by fusing greyscale versions of the original images into one image,and Reconstruction image2 was constructed based on the differences between the images captured under the different light sources.Subsequently,the four original images and two reconstructed images were input into the convolutional neural network AlexNet to recognize the density range in three cases:-1.5(clean coal) and+1.5 g/cm^(3)(non-clean coal);-1.8(non-gangue) and+1.8 g/cm^(3)(gangue);-1.5(clean coal),1.5-1.8(middlings),and+1.8 g/cm^(3)(gangue).The results show the following:(1) The reconstructed images,especially Reconstruction image 2,can effectively improve the recognition accuracy for the coal density range compared with images captured under single light source.(2) The recognition accuracies for gangue and non-gangue,clean coal and non-clean coal,and clean coal,middlings,and gangue reached88.44%,86.72% and 77.08%,respectively.(3) The recognition accuracy increases as the density moves further away from the boundary density.
文摘An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones.
文摘Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA.
文摘The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light source can be integrated with a time delay integration charge-coupled device (TDI CCD ) to capture the images of moving objects and facilitate inspection of the surface quality of tin steel strips. On-site application show the effectiveness of the TDI camera with the adaptive illumination light source in detecting the surface defects on tin steel strips of three different materials and with different tin coating weights.
文摘This paper deals with the topic of RF plasma sources and their application inhigh-power neutral beam heating systems for nuclear fusion devices. RF sources represent aninteresting alternative to the conventional arc discharge sources. Due to the absence of hotfilaments they exhibit an inherent simplicity both in mechanical and electrical aspects andconsequently offer advantages in terms of cost savings, gain in availability and reliability andreduced maintenance. This renders the RF plasma source attractive for any long pulse (> 10 sec) NBIsystem and in particular for the ITER NBI system. The latter, however, requires that the RF plasmasource is also capable of delivering negative rather than positive hydrogen ions. In the first partof the paper the types, characteristics and operation experience of RF plasma sources for positiveions in operation are described. The second part is devoted to the development for ITER NBI: thebasic requirements, physics and technology issues and the present status are discussed.
基金National High-tech Research & Development Plan(863 Projeet)(No.2008AA062317)National Natural Science Foundation of China(No.50578020)
文摘A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications.
基金supported by National Natural Science Foundation of China(No.11275200)
文摘Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to its high electron emission current. An indirectly heated oxide coated cathode plasma source has been constructed on a linear magnetized plasma device. The electron emission current density can reach 2 A/cm2 to 6 A/cm2 in pulsed mode within pulse length 5-20 ms. A 10 cm diameter, 2 m long plasma column with density 10is m-3 to 1019 m3 and electron temperature Te --~ 3-7 eV is produced. The spatial uniformity of the emission ability is less than 4% and the discharge reproducibility is better than 97%. With a wide range of the plasma parameters, this kind of plasma source provides great flexibility for many basic plasma investigations. The detail of construction and initial characterization of oxide coated cathode are described in this paper.
基金the National Natural Science Foundation of China(Grant No.11875222)。
文摘Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal the inside interaction between the plasma,magnetic field and microwave electric field.From the diagnosing result it can be found that the plasma density distribution is controlled by the plasma generation and electron loss volumes associated with the magnetic field and microwave power level.Based on the cold plasma hypothesis and diagnosing result,the microwave electric field intensity distribution in the plasma is calculated.The result shows that the plasma will significantly change the distribution of the microwave electric field intensity to form a bow shape.From the boundary region of the shape to the center,the electric field intensity varies from higher to lower and the diagnosed density inversely changes.If the bow and its inside lower electric field intensity region are close to the screen grid,the performance of ion beam extracting will be better.The study can provide useful information for the creating of 10 cm ECR ion source and understanding its mechanism.
基金supported by National Natural Science Foundation of China(No.11205201)
文摘By utilization of different excitation power sources, linear plasma sources can be differentiated into DC, RF, VHF, microwave and dual frequency types. Through installing several linear plasma sources in parallel or adopting the so-called roll-to-roll (air-to-air) process, scale uniform linear plasma sources were realized and successfully applied to the deposition of large area uniform dielectric thin films, Furthermore, the magnetic field system can effectively reduce the recombination losses on the wall of the vacuum chamber and enhance the plasma density. Linear plasma sources with approximately one square meter deposition area with the plasma density of 1011 cm 3 have been developed, some of which have been used for the deposition of dielectric layers and large area plasma etching.