期刊文献+
共找到4,337篇文章
< 1 2 217 >
每页显示 20 50 100
Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
1
作者 Sunil KANCHI Rohit SHUKLA Archana SHARMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期94-100,共7页
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In... Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources. 展开更多
关键词 coaxial plasma source triple Langmuir probe Faraday cup plasma density plasma temperature
下载PDF
Gas source of the Middle Jurassic Shaximiao Formation in the Zhongjiang large gas field of Western Sichuan Depression:Constraints from geochemical characteristics of light hydrocarbons
2
作者 Xiaoqi Wu Jun Yang +4 位作者 Ping Wang Huaji Li Yingbin Chen Chunhua Ni Huasheng Zeng 《Energy Geoscience》 EI 2024年第2期141-151,共11页
The Zhongjiang gas field is a typical large gas field in terrigenous strata of the Western Sichuan Depression.It remains debatable which member of the Upper Triassic Xujiahe Formation served as the source rocks and ho... The Zhongjiang gas field is a typical large gas field in terrigenous strata of the Western Sichuan Depression.It remains debatable which member of the Upper Triassic Xujiahe Formation served as the source rocks and how significant the member contributed to the gas accumulations in the Zhongjiang gas field.In this study,we analyzed the essential characteristics of the Lower Jurassic source rocks and the geochemical features of light hydrocarbons in natural gas from the 2nd(T_(3)χ^(2))and 4th members(T_(3)χ^(4))of the Upper Triassic Xujiahe Formation(T_(3)χ),as well as the Middle Jurassic Shaximiao(J_(2)s)and Qianfoya(J_(2)q)formations.Based on this,we explored the sources of the natural gas in the Zhongjiang gas field and determined the natural gas migration patterns and their effects on the properties of light hydrocarbons in the natural gas.The results indicate that the Lower Jurassic lacustrine source rocks of the Zhongjiang gas field contain humic organic matter,with vitrinite reflectance(R_(0))values ranging from 0.86%to 0.98%.Samples meeting the criterion for effective source rocks[total organic carbon(TOC)content≥0.75%]exhibited an average TOC content of merely 1.02%,suggesting significantly lower hydrocarbon generation potential than source rocks in the underlying T3x,which show higher thermal maturity and TOC contents.For natural gas samples from T_(3)χ^(2),T_(3)χ^(4),J_(2)s,and J_(2)q reservoirs,their C_(5-7)iso-alkane content was significantly higher than their n-alkane content,and their methylcyclohexane(MCH)index ranged from 59.0%to 77.3%,indicating the predominance of methylcyclohexane in C_(7)light hydrocarbons.As indicated by the origin identification and gas-source correlation based on the geochemical features of light hydrocarbons,the natural gas in the Zhongjiang gas field is typical coal-derived gas.The gas from the primary pay zone of the Shaximiao Formation,with significantly high K_(1),(P_(2)+N_(2))/C_(7),and P_(3)/C_(7)values,predominantly originated from the 5th member of the T3x and migrated in the free phase,with a small amount possibly sourced from the Lower Jurassic source rocks.The dissolution and adsorption during gas migration led to a decrease in the aromatic content in C_(6-7)light hydrocarbons and an increase in the isoheptane values.Therefore,their effects must be considered when determining the gas origin and thermal maturity based on the aromatic content in C_(6-7) light hydrocarbons and iso-heptane values. 展开更多
关键词 Zhongjiang gas field source rock Origin of natural gas light hydrocarbon geochemistry Natural gas migration
下载PDF
A laser-produced plasma source based on thin-film Gd targets for next-generation extreme ultraviolet lithography
3
作者 陈笑 黎遥 +5 位作者 侯鉴波 张哲 陆显扬 严羽 何亮 徐永兵 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第10期1-5,共5页
We have studied laser-produced plasma based on mass-limited thin-film Gd targets for beyond the current extreme ultraviolet(EUV)light source of 13.5 nm wavelength based on tin.The influences of the laser intensity on ... We have studied laser-produced plasma based on mass-limited thin-film Gd targets for beyond the current extreme ultraviolet(EUV)light source of 13.5 nm wavelength based on tin.The influences of the laser intensity on the emission spectra centered around 6.7 nm from thin-film Gd targets were first investigated.It is found that the conversion efficiency of the produced plasma is saturated when the laser intensity goes beyond 2×10^(11)W cm^(-2).We have systematically compared the emission spectra of the laser-produced plasma with the changes in the thicknesses of the thin-film Gd targets.It is proved that a minimum-mass target with a thickness of 400 nm is sufficient to provide the maximum conversion efficiency,which also implies that this thickness is the ablation depth for the targets.These findings should be helpful in the exploration of next-generation EUV sources,as the thin-film Gd targets will reduce the debris during the plasma generation process compared with the bulk targets. 展开更多
关键词 extreme ultraviolet light source laser-produced plasma GADOLINIUM
下载PDF
Modeling of magnetized collisional plasma sheath with nonextensive electron distribution and ionization source
4
作者 陈龙 杨叶慧 +5 位作者 安宇豪 段萍 孙少娟 崔作君 阚子晨 高维富 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第3期21-31,共11页
The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized pl... The properties of an atmospheric-pressure collisional plasma sheath with nonextensively distributed electrons and hypothetical ionization source terms are studied in this work. The Bohm criterion for the magnetized plasma is extended in the presence of an ion–neutral collisional force and ionization source. The effects of electron nonextensive distribution, ionization frequency, ion–neutral collision, magnetic field angle and ion temperature on the Bohm criterion of the plasma sheath are numerically analyzed. The fluid equations are solved numerically in the plasma–wall transition region using a modified Bohm criterion as the boundary condition. The plasma sheath properties such as charged particle density, floating sheath potential and thickness are thoroughly investigated under different kinds of ion source terms, contributions of collisions, and magnetic fields. The results show that the effect of the ion source term on the properties of atmosphericpressure collisional plasma sheath is significant. As the ionization frequency increases, the Mach number of the Bohm criterion decreases and the range of possible values narrows. When the ion source is considered, the space charge density increases, the sheath potential drops more rapidly,and the sheath thickness becomes narrower. In addition, ion–neutral collision, magnetic field angle and ion temperature also significantly affect the sheath potential profile and sheath thickness. 展开更多
关键词 plasma sheath Bohm criterion NONEXTENSIVITY ionization source
下载PDF
Ghost imaging based on the control of light source bandwidth
5
作者 刘兆骐 白艳锋 +3 位作者 邹璇彭凡 周立宇 付芹 傅喜泉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期276-279,共4页
A scheme to improve the quality in ghost imaging(GI)by controlling the bandwidth of light source(BCGI)is proposed.The theoretical and numerical results show that the reconstruction result with high quality can be obta... A scheme to improve the quality in ghost imaging(GI)by controlling the bandwidth of light source(BCGI)is proposed.The theoretical and numerical results show that the reconstruction result with high quality can be obtained by adjusting the bandwidth range of the light source appropriately,and the selection criterion of the bandwidth is analyzed by the power distribution of the imaging target.A proof-of-principle experiment is implemented to verify the theoretical and numerical results.In addition,the BCGI also presents better anti-noise performance when compared with some popular GI methods. 展开更多
关键词 ghost imaging light source property spatial frequency domain
下载PDF
Wave field structure and power coupling features of blue-core helicon plasma driven by various antenna geometries and frequencies
6
作者 王超 刘佳 +3 位作者 苌磊 卢凌峰 张世杰 周帆涛 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期480-487,共8页
This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagat... This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagate in the core region,and it decays sharply outside the core.The power absorption is lower and steeper in radius for blue-core mode.Regarding the effects of antenna geometry for blue-core mode,it shows that half helix antenna yields the strongest wave field and power absorption,while loop antenna yields the lowest.Moreover,near axis,for antennas with m=+1,the wave field increases with axial distance.In the core region,the wave number approaches to a saturation value at much lower frequency for non-blue-core mode compared to blue-core mode.The total loading resistance is much lower for blue-core mode.These findings are valuable to understanding the physics of blue-core helicon discharge and optimizing the experimental performance of blue-core helicon plasma sources for applications such as space propulsion and material treatment. 展开更多
关键词 helicon plasma helicon wave helicon discharge radio frequency plasma source
下载PDF
Plasma density enhancement in radio-frequency hollow electrode discharge
7
作者 贺柳良 何锋 欧阳吉庭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期44-51,共8页
The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results s... The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results show that plasma exists inside the cavity when the sheath inside the hollow electrode hole is fully collapsed, which is an essential condition for the plasma density enhancement outside hollow electrodes. In addition, the existence of the electron density peak at the orifice is generated via the hollow cathode effect(HCE), which plays an important role in the density enhancement. It is also found that the radial width of bulk plasma at the orifice affects the magnitude of the density enhancement, and narrow radial plasma bulk width at the orifice is not beneficial to obtain high-density plasma outside hollow electrodes.Higher electron density at the orifice, combined with larger radial plasma bulk width at the orifice,causes higher electron density outside hollow electrodes. The results also imply that the HCE strength inside the cavity cannot be determined by the magnitude of the electron density outside hollow electrodes. 展开更多
关键词 RF capacitively coupled plasma sources plasma density enhancement hollow cathodeeffect hollow electrode
下载PDF
Dielectric barrier discharge plasma-assisted catalytic ammonia synthesis:synergistic effect of Ni-MOF-74 catalyst and nanosecond pulsed plasma
8
作者 徐晓芳 孙萌 +4 位作者 宋勤龙 吴璇 陈冲冲 陈强 张海宝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期40-49,共10页
Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading t... Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading to significant energy consumption and environmental pollution.Non-thermal plasma(NTP) is a promising alternative approach to ammonia synthesis at low temperature and atmospheric pressure.In this study,the synergistic effect of nanosecond pulsed dielectric barrier discharge(np-DBD) and Ni-MOF-74 catalyst was investigated in ammonia synthesis by utilizing nitrogen and hydrogen as feedstock.The results demonstrated that the plasma catalytic-synthesis process parameters play a crucial role in the synthesis process of ammonia.The highest ammonia synthesis rate of 5145.16 μmol·g^(-1)·h^(-1)with an energy efficiency of 1.27 g·kWh^(-1)was observed in the presence of the Ni-MOF-74 catalyst,which was3.7 times higher than that without Ni-MOF-74 catalyst.The synergistic effect of Ni-MOF-74catalyst and nanosecond pulsed plasma was explored by in-situ plasma discharge diagnostics. 展开更多
关键词 AMMONIA SYNTHESIS low-temperature plasma nanosecond pulsed power source Ni-MOF-74
下载PDF
Storage time affects the level and diagnostic efficacy of plasma biomarkers for neurodegenerative diseases
9
作者 Lifang Zhao Mingkai Zhang +4 位作者 Qimeng Li Xuemin Wang Jie Lu Ying Han Yanning Cai 《Neural Regeneration Research》 SCIE CAS 2025年第8期2373-2381,共9页
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k... Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results. 展开更多
关键词 Alzheimer’s disease amyloid-β diagnostic ability glial fibrillary acidic protein NEURODEGENERATION neurofilament light chain plasma biomarkers single molecule array storage time tau
下载PDF
Metamerism Appreciation of Jadeite-Jade Green under the Standard Light Sources D_(65),A and CWF 被引量:6
10
作者 GUO Ying WANG Huan +1 位作者 LI Xiang DONG Shirong 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2016年第6期2097-2103,共7页
We tested 288 pieces of the polished cabochon jadeite-jade with high quality green and smooth surfaces using the colorimeter Color i5 based on the CIE 1976 L*a*b* uniform color space. The color changes after altern... We tested 288 pieces of the polished cabochon jadeite-jade with high quality green and smooth surfaces using the colorimeter Color i5 based on the CIE 1976 L*a*b* uniform color space. The color changes after alternating three CIE standard light sources D65, A and CWF were compared, and the degree of metamerism was evaluated. The results show that the CIE standard light sources D65, A and CWF increase the chroma of green and turn bluish green into vivid green, which are similar or to nearly colorless and transparent glass-like samples with fine textures. When the three light sources were individually alternated, the lightness of the jadeite-jades showed little change, but the tone changed significantly. Metamerism occurred only in 3 pairs among the 16 samples that were selected by cluster analysis for quality, and the metamerism colors were highly consistent of L*D65∈(43.47, 46.75), C*D65∈(65.20, 68.80) and ho*D65∈(138.10, 140.23). We can conclude that the jadeite-jade green gradually turns to blue when the color temperature of the light source increases. But when considering both the light sources and the samples, D65 is more suitable to be the light source of jadeite-jade green when compared with the light sources CWF and A. Compared with the CIE standard green and high chroma green, high-quality jadeite-jade green has a slight yellow tone, low lightness and high chroma. The special metamerism index decreased to 1 when the light source alternated among D65, A and CWF. Therefore, the color of jadeite-jade green might be slightly influenced by alternating of the light sources. 展开更多
关键词 Jadeite-Jade green CIE standard light source light source alteration special metamerism index
下载PDF
Early gastric cancer diagnostic ability of ultrathin endoscope loaded with laser light source 被引量:7
11
作者 Takuto Suzuki Yoshiyasu Kitagawa +1 位作者 Rino Nankinzan Taketo Yamaguchi 《World Journal of Gastroenterology》 SCIE CAS 2019年第11期1378-1386,共9页
BACKGROUND Conventionally, the low luminous intensity, low image resolution, and difficulty in operation have been reported with the ultrathin endoscope. However, it has markedly advanced recently. The improvement of ... BACKGROUND Conventionally, the low luminous intensity, low image resolution, and difficulty in operation have been reported with the ultrathin endoscope. However, it has markedly advanced recently. The improvement of the diagnostic ability is expected.AIM To compare the early gastric cancer diagnostic ability of an ultrathin endoscope loaded with a laser light source and that of the conventional endoscope.METHODS The target subjects were 375 consecutive patients who underwent endoscopy at our hospital for post-endoscopic submucosal dissection follow-up of gastric cancer from January to August 2018. During endoscopy, the ultrathin endoscope was used in 140 patients(37.3%), and the conventional endoscope was used in235 patients(62.7%). Patient background was adjusted using the propensity score matching method, and gastric cancer detection ability was evaluated in the two groups.RESULTS The gastric cancer detection rate was 7.8% in the ultrathin endoscope group and7.0% in the conventional endoscope group, and the mean intragastric observation time was 4.1 ± 1.7 min in the ultrathin endoscope group and 4.1 ± 1.9 min in the conventional endoscope group, showing no significant differences between the groups. Moreover, the biopsy implementation rate was 31.8% in the ultrathin endoscope group and 41.1% in the conventional endoscope group, and the biopsy prediction rate was 17.9% and 13.2%, respectively, showing no significant differences between the groups.CONCLUSION The gastric cancer diagnostic ability of the ultrathin endoscope loaded with a laser light source was comparable to that of the conventional endoscope. The observation time was also comparable. Thus, endoscopy using the ultrathin endoscope loaded with the laser light source would be the first option in screening examinations of gastric cancer due to its low invasion. 展开更多
关键词 CONVENTIONAL ENDOSCOPE GASTRIC cancer LASER light source Screening ULTRATHIN ENDOSCOPE
下载PDF
Fast recognition using convolutional neural network for the coal particle density range based on images captured under multiple light sources 被引量:6
12
作者 Feiyan Bai Minqiang Fan +1 位作者 Hongli Yang Lianping Dong 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2021年第6期1053-1061,共9页
A method based on multiple images captured under different light sources at different incident angles was developed to recognize the coal density range in this study.The innovation is that two new images were construc... A method based on multiple images captured under different light sources at different incident angles was developed to recognize the coal density range in this study.The innovation is that two new images were constructed based on images captured under four single light sources.Reconstruction image 1 was constructed by fusing greyscale versions of the original images into one image,and Reconstruction image2 was constructed based on the differences between the images captured under the different light sources.Subsequently,the four original images and two reconstructed images were input into the convolutional neural network AlexNet to recognize the density range in three cases:-1.5(clean coal) and+1.5 g/cm^(3)(non-clean coal);-1.8(non-gangue) and+1.8 g/cm^(3)(gangue);-1.5(clean coal),1.5-1.8(middlings),and+1.8 g/cm^(3)(gangue).The results show the following:(1) The reconstructed images,especially Reconstruction image 2,can effectively improve the recognition accuracy for the coal density range compared with images captured under single light source.(2) The recognition accuracies for gangue and non-gangue,clean coal and non-clean coal,and clean coal,middlings,and gangue reached88.44%,86.72% and 77.08%,respectively.(3) The recognition accuracy increases as the density moves further away from the boundary density. 展开更多
关键词 COAL Density range Image Multiple light sources Convolutional neural network
下载PDF
Finite element analysis of keyhole plasma arc welding based on an adaptive heat source mode 被引量:5
13
作者 胡庆贤 武传松 张裕明 《China Welding》 EI CAS 2007年第2期55-58,共4页
An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature ... An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones. 展开更多
关键词 keyhole plasma arc welding adaptive heat source mode finite element analysis
下载PDF
Diagnosis of Hydrogen Plasma in a Miniature Penning Ion Source by Double Probes 被引量:2
14
作者 金大志 杨中海 +1 位作者 肖坤祥 戴晶怡 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期48-51,共4页
Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron dens... Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA. 展开更多
关键词 Penning discharge ion source hydrogen plasma DIAGNOSIS double probes
下载PDF
Adaptive illumination light source for online machine vision inspection of tin steel strips 被引量:3
15
作者 PENG Tiegen HE Yonghui 《Baosteel Technical Research》 CAS 2013年第4期25-28,共4页
The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light so... The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light source can be integrated with a time delay integration charge-coupled device (TDI CCD ) to capture the images of moving objects and facilitate inspection of the surface quality of tin steel strips. On-site application show the effectiveness of the TDI camera with the adaptive illumination light source in detecting the surface defects on tin steel strips of three different materials and with different tin coating weights. 展开更多
关键词 adaptive illumination light source tin steel strip TDI camera
下载PDF
Development of Powerful RF Plasma Sources for Present and Future NBI Systems 被引量:2
16
作者 E.Speth NBI-Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第1期2135-2140,共6页
This paper deals with the topic of RF plasma sources and their application inhigh-power neutral beam heating systems for nuclear fusion devices. RF sources represent aninteresting alternative to the conventional arc d... This paper deals with the topic of RF plasma sources and their application inhigh-power neutral beam heating systems for nuclear fusion devices. RF sources represent aninteresting alternative to the conventional arc discharge sources. Due to the absence of hotfilaments they exhibit an inherent simplicity both in mechanical and electrical aspects andconsequently offer advantages in terms of cost savings, gain in availability and reliability andreduced maintenance. This renders the RF plasma source attractive for any long pulse (> 10 sec) NBIsystem and in particular for the ITER NBI system. The latter, however, requires that the RF plasmasource is also capable of delivering negative rather than positive hydrogen ions. In the first partof the paper the types, characteristics and operation experience of RF plasma sources for positiveions in operation are described. The second part is devoted to the development for ITER NBI: thebasic requirements, physics and technology issues and the present status are discussed. 展开更多
关键词 neutral beam injection negative ions RF plasma source
下载PDF
Experimental Study of a Minitype Atmospheric Non-equilibrium Plasma Source 被引量:2
17
作者 白希尧 周建刚 +2 位作者 邱秀梅 刘栋 白敏冬 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第6期724-726,共3页
A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-fie... A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications. 展开更多
关键词 atmosphere high voltage ionizing source ion density gas particle momentum electric discharging non-equilibrium plasma
下载PDF
Oxide Coated Cathode Plasma Source of Linear Magnetized Plasma Device 被引量:1
18
作者 HU Guanghai JIN Xiaoli +4 位作者 YUAN Lin ZHANG Qiaofeng XIE Jinlin LI Hong LIU Wandong 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期918-923,共6页
Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to it... Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to its high electron emission current. An indirectly heated oxide coated cathode plasma source has been constructed on a linear magnetized plasma device. The electron emission current density can reach 2 A/cm2 to 6 A/cm2 in pulsed mode within pulse length 5-20 ms. A 10 cm diameter, 2 m long plasma column with density 10is m-3 to 1019 m3 and electron temperature Te --~ 3-7 eV is produced. The spatial uniformity of the emission ability is less than 4% and the discharge reproducibility is better than 97%. With a wide range of the plasma parameters, this kind of plasma source provides great flexibility for many basic plasma investigations. The detail of construction and initial characterization of oxide coated cathode are described in this paper. 展开更多
关键词 oxide coated cathode plasma source magnetized plasma pulse discharge
下载PDF
Interaction between plasma and electromagnetic field in ion source of 10 cm ECR ion thruster 被引量:2
19
作者 Hao Mou Yi-Zhou Jin +2 位作者 Juan Yang Xu Xia Yu-Liang Fu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期404-412,共9页
Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal th... Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal the inside interaction between the plasma,magnetic field and microwave electric field.From the diagnosing result it can be found that the plasma density distribution is controlled by the plasma generation and electron loss volumes associated with the magnetic field and microwave power level.Based on the cold plasma hypothesis and diagnosing result,the microwave electric field intensity distribution in the plasma is calculated.The result shows that the plasma will significantly change the distribution of the microwave electric field intensity to form a bow shape.From the boundary region of the shape to the center,the electric field intensity varies from higher to lower and the diagnosed density inversely changes.If the bow and its inside lower electric field intensity region are close to the screen grid,the performance of ion beam extracting will be better.The study can provide useful information for the creating of 10 cm ECR ion source and understanding its mechanism. 展开更多
关键词 electron cyclotron resonance plasma plasma diagnosing ion source
下载PDF
Linear Plasma Sources for Large Area Film Deposition:A Brief Review 被引量:1
20
作者 魏钰 左潇 +4 位作者 陈龙威 孟月东 方世东 沈洁 舒兴胜 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期356-362,共7页
By utilization of different excitation power sources, linear plasma sources can be differentiated into DC, RF, VHF, microwave and dual frequency types. Through installing several linear plasma sources in parallel or a... By utilization of different excitation power sources, linear plasma sources can be differentiated into DC, RF, VHF, microwave and dual frequency types. Through installing several linear plasma sources in parallel or adopting the so-called roll-to-roll (air-to-air) process, scale uniform linear plasma sources were realized and successfully applied to the deposition of large area uniform dielectric thin films, Furthermore, the magnetic field system can effectively reduce the recombination losses on the wall of the vacuum chamber and enhance the plasma density. Linear plasma sources with approximately one square meter deposition area with the plasma density of 1011 cm 3 have been developed, some of which have been used for the deposition of dielectric layers and large area plasma etching. 展开更多
关键词 linear plasma sources large area UNIFORM high density
下载PDF
上一页 1 2 217 下一页 到第
使用帮助 返回顶部