期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Effects of microlens array orientation errors on plenoptic imaging of flame radiative properties and uncertainty analysis 被引量:2
1
作者 LI SuNing YUAN Yuan TAN HePing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2021年第10期2119-2141,共23页
Plenoptic imaging(PI)systems can flexibly record both spatial and angular information on flame radiation,enabling volumetric reconstruction of complex flames.The accuracy and efficiency of the reconstruction are signi... Plenoptic imaging(PI)systems can flexibly record both spatial and angular information on flame radiation,enabling volumetric reconstruction of complex flames.The accuracy and efficiency of the reconstruction are significantly affected by the orientation parameters of the microlens array(MLA)in the system.To investigate the influence of potential parameter errors on flame light fields,we establish a typical orientation error model and employ ray-splitting-based Monte Carlo method to simulate the entire and sectioned PI for the three-dimensional flame under four error conditions,in which different radiative properties of flame(extinction coefficient,scattering albedo,and scattering phase function)are considered.Through the proposed uncertainty evaluation scheme,the flame image characteristics,intensity,structure deviations,and their local distribution for four error types are analyzed.The results show that the extinction coefficient and the MLA error type determine the flame PI uncertainty features,while the scattering properties only change the deviation levels.The major impact of the extinction coefficient on the transfer and accumulation of uncertainty in flame-sectioned PI is also revealed. 展开更多
关键词 radiative transfer plenoptic imaging radiative properties uncertainty quantification parameter errors flame reconstruction
原文传递
Three-dimensional temperature reconstruction of diffusion flame from the light-field convolution imaging by the focused plenoptic camera 被引量:5
2
作者 SHI JingWen QI Hong +3 位作者 YU ZhiQiang AN XiangYang REN YaTao TAN HePing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2022年第2期302-323,共22页
The plenoptic imaging technique provides a promising approach to the non-invasive three-dimensional measurement, especially for the high-temperature combustion diagnosis. We establish a light-field convolution imaging... The plenoptic imaging technique provides a promising approach to the non-invasive three-dimensional measurement, especially for the high-temperature combustion diagnosis. We establish a light-field convolution imaging model for diffusion flame in this work, considering the radiation transfer process inside the diffusion flame and the light transfer process inside the focused plenoptic camera together. The radiation transfer process is described by the radiation transfer equation and solved by the generalized source multi-flux method. Wave optics theory is adopted to describe the light transfer process, combining Fresnel diffraction and the phase conversion of the lens. The flame light-field image is obtained by the light-field convolution imaging model and adopted as the measurement signal to reconstruct three-dimensional temperature field. The inverse problem of temperature reconstruction is solved by the least square QR decomposition method. The simulative temperature reconstruction work is conducted, including the inverse analysis, the uncertainty analysis, and the measurement noise influence. All the results show that the proposed measurement method is available to reconstruct three-dimensional temperature with satisfactory accuracy and acceptable uncertainty. Both symmetric and asymmetric distributed temperature fields are investigated, and the reconstructed results prove the validity and universality of the measurement method. 展开更多
关键词 temperature measurement plenoptic convolution imaging model diffusion flame uncertainty analysis inverse problem
原文传递
Experimental assessment of a 3-D plenoptic endoscopic imaging system 被引量:1
3
作者 Hanh N. D. Le Ryan Decker +1 位作者 Axel Krieger Jin U. Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第5期68-72,共5页
All endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera... All endoscopic imaging system using a plenoptic technique to reconstruct 3-D information is demonstrated and analyzed in this Letter. The proposed setup integrates a clinical surgical endoscope with a plenoptic camera to achieve a depth accuracy error of about 1 mm and a precision error of about 2 mm, within a 25 mm×25 mm field of view, operating at 11 frames per second. 展开更多
关键词 Experimental assessment of a 3-D plenoptic endoscopic imaging system FOV MLA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部