期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Controllable all-optical stochastic logic gates and their delay storages based on the cascaded VCSELs with optical-injection 被引量:5
1
作者 钟东洲 罗伟 许葛亮 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期342-354,共13页
Using the dynamical properties of the polarization bistability that depends on the detuning of the injected light,we propose a novel approach to implement reliable all-optical stochastic logic gates in the cascaded ve... Using the dynamical properties of the polarization bistability that depends on the detuning of the injected light,we propose a novel approach to implement reliable all-optical stochastic logic gates in the cascaded vertical cavity surface emitting lasers(VCSELs) with optical-injection.Here,two logic inputs are encoded in the detuning of the injected light from a tunable CW laser.The logic outputs are decoded from the two orthogonal polarization lights emitted from the optically injected VCSELs.For the same logic inputs,under electro-optic modulation,we perform various digital signal processing(NOT,AND,NAND,XOR,XNOR,OR,NOR) in the all-optical domain by controlling the logic operation of the applied electric field.Also we explore their delay storages by using the mechanism of the generalized chaotic synchronization.To quantify the reliabilities of these logic gates,we further demonstrate their success probabilities. 展开更多
关键词 all-optical stochastic logic gates delay storage polarization bistable success probability
下载PDF
Glucose detection in a highly scattering medium with diffuse photon-pair density wave
2
作者 Li-Ping Yu Jheng-Syong Wu +1 位作者 Sheng-Yi Chang Chien Chou 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第1期53-58,共6页
We propose a novel optical method for glucose measurement based on difuse photon-pair density wave(DPPDW)in a multiple scattering medium(MSM)where the light scattering of photon-pair is induced by refractive index mis... We propose a novel optical method for glucose measurement based on difuse photon-pair density wave(DPPDW)in a multiple scattering medium(MSM)where the light scattering of photon-pair is induced by refractive index mismatch between scatters and phantom solution.Experi-mentally,the DPPDW propagates in MSM via a two frequency laser(TFL)beam wherein highly correlated pairs of linear polarized photons are generated.The reduced scattering coefficientμ2s and absorption coefficientμ2a of DPPDW are measured simultaneously in terms of the amplitude and phase measurements of the detected heterodyne signal under arrangement at different dis-tances between the source and detection fibers in MSM.The results show that the sensitivity of glucose detection via glucose-induced change of reduced scattering coefficient(δμ′2)is 0.049%mM^(-1)in a 1%intralipid solution.In addition,the linear range ofδμ′2s vs glucose concentration implies that this DPPDW method can be used to monitor glucose concentration continuously and noninvasively subcutaneously. 展开更多
关键词 Difuse photon-pair density wave GLUCOSE multiple scattering polarization gating spatial coherence gating.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部