期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Radial Force Analysis of Polydioxanone Coronary Stent by Finite Element Method 被引量:2
1
作者 阙志文 张佩华 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期375-377,共3页
Coronary stent is used to treat stenosis artery by recovering the luminal diameter of artery and maintaining the normal blood flow. The geometry of coronary stent is an important factor for the radial force. In this s... Coronary stent is used to treat stenosis artery by recovering the luminal diameter of artery and maintaining the normal blood flow. The geometry of coronary stent is an important factor for the radial force. In this study,the relation between the radial force of stent and crown angle was discussed. The result showed that there was no particular rule between the radial force of stent and the crown angle. The maximum radial force of stent was obtained when the crown angle was 50. 04° and the minimum radial force was got when the crown angle was 75°. 展开更多
关键词 polydioxanone CORONARY STENT CROWN angle FINITE element method(FEM)
下载PDF
Comparison of post-urethroplasty complication rates in pediatric cases with hypospadias using Vicryl or polydioxanone sutures 被引量:1
2
作者 Mehdi Shirazi Abdolreza Haghpanah +3 位作者 Anahita Dehghani Sezaneh Haghpanah Mehdi Ghahartars Mahdi Rahmanian 《Asian Journal of Urology》 CSCD 2022年第2期165-169,共5页
Objective:Hypospadias is a common congenital problem among male newborns.Both rapid absorbable sutures(polyglactin,Vicryl)and delayed absorbable sutures(polydioxanone,PDO)are used in hypospadias repair based on the su... Objective:Hypospadias is a common congenital problem among male newborns.Both rapid absorbable sutures(polyglactin,Vicryl)and delayed absorbable sutures(polydioxanone,PDO)are used in hypospadias repair based on the surgeon's preference.This study was conducted to compare post-urethroplasty complication rates in pediatric patients with hypospadias using Vicryl or PDO sutures.Methods:This is a retrospective study which was designed and performed on 583 children aged 1-7 years old who had undergone hypospadias repair from January 2012 to December 2018.Required data were obtained from the patients'medical records.Results:Overall,post-surgical complications were observed in 60(10.3%)patients comprising urethro-cutaneous fistula(n=39,6.7%),meatal stenosis(n=10,1.7%),urethral stricture(n=7,1.2%),and glans dehiscence(n=4,0.7%).The mean age of the children with complications was 3.0±1.3 years.According to Kaplan-Meier estimate,the interval between surgery and development of complications was significantly shorter in the Vicryl group(p=0.037).Overall,complications were more prevalent in Vicryl suture than PDO suture(15.1%vs.5.3%,p<0.001).Regression model revealed that in comparison to the distal type,proximal hypospadias(odds ratio[OR]:103.9,95%confidence interval[CI]:32.2-334.9,p<0.001)and mid-shaft hypospadias(OR:82.9,95%CI:25.9-264.6,p<0.001)while using Vicryl suture instead of PDO suture(OR:62.4,95%CI:21.2-183.8,p<0.001)increased the odds of developing post-urethroplasty complications.Conclusion:We suggest PDO suture in the repair of hypospadias due to its lower complication rate,especially in cases of proximal and mid-shaft hypospadias which can get more complicated than the distal type. 展开更多
关键词 HYPOSPADIAS Urinary fistula Polyglactin polydioxanone
下载PDF
Evaluation of Relationship between the Geometry of Crown and Radial Force in a Polydioxanone Coronary Stent
3
作者 杨洁莹 阙志文 +1 位作者 陈南梁 张佩华 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期389-390,共2页
Polydioxanone(PDS),one of the bioabsorbable materials for coronary stent,is catching eyes of researchers recently. When designing the geometry of the PDS coronary stent,the length and the height of the crown are quite... Polydioxanone(PDS),one of the bioabsorbable materials for coronary stent,is catching eyes of researchers recently. When designing the geometry of the PDS coronary stent,the length and the height of the crown are quite important. However,rarely literatures have discussed the relationship between the two geometry parameters and the radial force of the bioabsorbable coronary stent. Therefore,a current effective tool of finite element method was applied in the evaluation of the relationship. By simulating 4 groups of models,it was obtained that the radial force of the coronary stent would not definitely increase with the rising value of Lcrownfrom 0. 8 mm to 2. 4mm. Meanwhile,Hcrownand radial force of the coronary stent had no linear relationship with each other. 展开更多
关键词 polydioxanone(PDS) CORONARY STENT finite element method the length of the CROWN the HEIGHT of the CROWN
下载PDF
Biodegradable stent for the treatment of a colonic stricture in Crohn's disease 被引量:9
4
作者 Catarina Rodrigues Ana Oliveira +2 位作者 Liliana Santos Eduardo Pires Joo Deus 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第5期265-269,共5页
Biodegradable polydioxanone stents were developed for the treatment of refractory benign esophageal strictures but have been suggested as a new therapeutic option for intestinal strictures.The primary advantage of bio... Biodegradable polydioxanone stents were developed for the treatment of refractory benign esophageal strictures but have been suggested as a new therapeutic option for intestinal strictures.The primary advantage of biodegradable stents over self-expandable metallic stents is that removal is not required.There are,however,few data available on their use in the small or large bowel.We herein describe the case of a 33-yearold patient with long-standing Crohn's disease(CD) who developed a fibrotic stricture of the sigmoid too long to be amenable to balloon dilation.The use of a biodegradable polydioxanone stent was chosen to avoid surgery.Combined endoscopic and fluoroscopic placement of the stent was technically simple,safe and clinically successful,and no recurrence of obstructive symptoms occurred during a 16-mo follow-up.Further studies are needed to evaluate the long-term efficacy and safety of biodegradable stents in the treatment of intestinal strictures,particularly in the context of CD. 展开更多
关键词 Crohn’s disease FIBROSIS Intestinal OBSTRUCTION STENTS polydioxanone
下载PDF
Synthetic Absorbable Surgical Sutures
5
作者 于建明 《Journal of China Textile University(English Edition)》 EI CAS 1999年第1期59-65,共7页
This paper reviewed all types of the polymer - based synthetic absorbable surgical sutures that have been commercially produced. The chemical component, biological and mechanical properties, and using effect of these ... This paper reviewed all types of the polymer - based synthetic absorbable surgical sutures that have been commercially produced. The chemical component, biological and mechanical properties, and using effect of these sutures were discussed. The recent development and the possible coming research orientation in these areas were also presented. 展开更多
关键词 SYNTHETIC ABSORBABLE sutures’ POLY ( glycolic acid) polylactide polydioxanone poly(glycolide -co - tri-methylene carbonate) poly(glycolide -co - caprolactone) .
下载PDF
Clinical features and literature review related to the material differences in thread rhinoplasty:Two case reports
6
作者 Da Woon Lee Heongrae Ryu +1 位作者 Si-Hyong Jang Jun Hyuk Kim 《World Journal of Clinical Cases》 SCIE 2021年第31期9635-9644,共10页
BACKGROUND Thread rhinoplasty can trigger a reaction to thread material,which is a foreign body.We compared clinical features induced by absorbable and non-absorbable threads following thread rhinoplasty.CASE SUMMARY ... BACKGROUND Thread rhinoplasty can trigger a reaction to thread material,which is a foreign body.We compared clinical features induced by absorbable and non-absorbable threads following thread rhinoplasty.CASE SUMMARY Two patients who underwent different thread materials showed different clinical courses and different Hounsfield unit(HU)values in computed tomography.Patients with absorbable thread showed high HU values similar to a metallic material,and the HU value of inflammation was similar to vascular tissues with a lot of water(250).In the intraoperative field,absorbable thread materials and micro-abscesses were observed.In contrast,in the case of a non-absorbable thread,an object presumed to be thread was seen on the computed tomography(CT),and the HU value of inflammatory tissues was less than 100.In both patients,post-operative HU decreased to less than 100 and the clinical course improved.In both cases,histopathologic findings revealed foreign body granuloma associated with inflammation.CONCLUSION Absorbable threads were more aggressive and are more easily detected on CT. 展开更多
关键词 Thread rhinoplasty polydioxanone Polyprophylene Hounsfield unit Computed tomography
下载PDF
A review on biodegradable biliary stents: materials and future trends 被引量:3
7
作者 Ge Song Hugh Q.Zhao +1 位作者 Qing Liu Zhongyong Fan 《Bioactive Materials》 SCIE 2022年第11期488-495,共8页
Biliary stricture is defined as the reduction and narrowing of the bile duct lumen, which can be caused by many factors such as cancer and inflammation. Biliary stent placement can effectively alleviate benign and mal... Biliary stricture is defined as the reduction and narrowing of the bile duct lumen, which can be caused by many factors such as cancer and inflammation. Biliary stent placement can effectively alleviate benign and malignant biliary strictures. However, the commonly used plastic or metallic biliary stents are far from ideal and do not satisfy all clinical requirements,although several types of biodegradable biliary stents have been developed and used clinically. In this review, we summarized current development status of biodegradable stents with the emphasis on the stent materials. We also presented the future development trends based on the published literature. 展开更多
关键词 Biodegradable biliary stent Biliary strictures polydioxanone Poly(L-lactic acid) Drug-eluting stent
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部