期刊文献+
共找到201篇文章
< 1 2 11 >
每页显示 20 50 100
Polyethylene glycol has immunoprotective effects on sciatic allografts, but behavioral recovery and graft tolerance require neurorrhaphy and axonal fusion
1
作者 Tyler A.Smith Liwen Zhou +6 位作者 Cameron L.Ghergherehchi Michelle Mikesh Cathy Z.Yang Haley O.Tucker JuliAnne Allgood Jared S.Bushman George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第4期1192-1206,共15页
Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripher... Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripheral nerve allografts undergo immunological rejection by the host immune system.In contrast,peripheral nerve injuries repaired by polyethylene glycol fusion of peripheral nerve allografts exhibit excellent behavioral recovery within weeks,reduced immune responses,and many axons do not undergo Wallerian degeneration.The relative contribution of neurorrhaphy and polyethylene glycol-fusion of axons versus the effects of polyethylene glycol per se was unknown prior to this study.We hypothesized that polyethylene glycol might have some immune-protective effects,but polyethylene glycol-fusion was necessary to prevent Wallerian degeneration and functional/behavioral recovery.We examined how polyethylene glycol solutions per se affect functional and behavioral recovery and peripheral nerve allograft morphological and immunological responses in the absence of polyethylene glycol-induced axonal fusion.Ablation-type sciatic nerve injuries in outbred Sprague–Dawley rats were repaired according to a modified protocol using the same solutions as polyethylene glycol-fused peripheral nerve allografts,but peripheral nerve allografts were loose-sutured(loose-sutured polyethylene glycol)with an intentional gap of 1–2 mm to prevent fusion by polyethylene glycol of peripheral nerve allograft axons with host axons.Similar to negative control peripheral nerve allografts not treated by polyethylene glycol and in contrast to polyethylene glycol-fused peripheral nerve allografts,animals with loose-sutured polyethylene glycol peripheral nerve allografts exhibited Wallerian degeneration for all axons and myelin degeneration by 7 days postoperatively and did not recover sciatic-mediated behavioral functions by 42 days postoperatively.Other morphological signs of rejection,such as collapsed Schwann cell basal lamina tubes,were absent in polyethylene glycol-fused peripheral nerve allografts but commonly observed in negative control and loose-sutured polyethylene glycol peripheral nerve allografts at 21 days postoperatively.Loose-sutured polyethylene glycol peripheral nerve allografts had more pro-inflammatory and less anti-inflammatory macrophages than negative control peripheral nerve allografts.While T cell counts were similarly high in loose-sutured-polyethylene glycol and negative control peripheral nerve allografts,loose-sutured polyethylene glycol peripheral nerve allografts expressed some cytokines/chemokines important for T cell activation at much lower levels at 14 days postoperatively.MHCI expression was elevated in loose-sutured polyethylene glycol peripheral nerve allografts,but MHCII expression was modestly lower compared to negative control at 21 days postoperatively.We conclude that,while polyethylene glycol per se reduces some immune responses of peripheral nerve allografts,successful polyethylene glycol-fusion repair of some axons is necessary to prevent Wallerian degeneration of those axons and immune rejection of peripheral nerve allografts,and produce recovery of sensory/motor functions and voluntary behaviors.Translation of polyethylene glycol-fusion technologies would produce a paradigm shift from the current clinical practice of waiting days to months to repair ablation peripheral nerve injuries. 展开更多
关键词 allograft rejection AXOTOMY macrophage MYELIN nerve repair polyethylene glycol(PEG) sciatic nerve T cell transplantation Wallerian degeneration
下载PDF
Polyethylene glycol fusion repair of severed sciatic nerves accelerates recovery of nociceptive sensory perceptions in male and female rats of different strains
2
作者 Liwen Zhou Karthik Venkudusamy +9 位作者 Emily A.Hibbard Yessenia Montoya Alexa Olivarez Cathy Z.Yang Adelaide Leung Varun Gokhale Guhan Periyasamy Zeal Pathak Dale R.Sengelaub George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第9期2667-2681,共15页
Successful polyethylene glycol fusion(PEG-fusion)of severed axons following peripheral nerve injuries for PEG-fused axons has been reported to:(1)rapidly restore electrophysiological continuity;(2)prevent distal Walle... Successful polyethylene glycol fusion(PEG-fusion)of severed axons following peripheral nerve injuries for PEG-fused axons has been reported to:(1)rapidly restore electrophysiological continuity;(2)prevent distal Wallerian Degeneration and maintain their myelin sheaths;(3)promote primarily motor,voluntary behavioral recoveries as assessed by the Sciatic Functional Index;and,(4)rapidly produce correct and incorrect connections in many possible combinations that produce rapid and extensive recovery of functional peripheral nervous system/central nervous system connections and reflex(e.g.,toe twitch)or voluntary behaviors.The preceding companion paper describes sensory terminal field reo rganization following PEG-fusion repair of sciatic nerve transections or ablations;howeve r,sensory behavioral recovery has not been explicitly explored following PEG-fusion repair.In the current study,we confirmed the success of PEG-fusion surgeries according to criteria(1-3)above and more extensively investigated whether PEG-fusion enhanced mechanical nociceptive recovery following sciatic transection in male and female outbred Sprague-Dawley and inbred Lewis rats.Mechanical nociceptive responses were assessed by measuring withdrawal thresholds using von Frey filaments on the dorsal and midplantar regions of the hindpaws.Dorsal von Frey filament tests were a more reliable method than plantar von Frey filament tests to assess mechanical nociceptive sensitivity following sciatic nerve transections.Baseline withdrawal thresholds of the sciatic-mediated lateral dorsal region differed significantly across strain but not sex.Withdrawal thresholds did not change significantly from baseline in chronic Unoperated and Sham-operated rats.Following sciatic transection,all rats exhibited severe hyposensitivity to stimuli at the lateral dorsal region of the hindpaw ipsilateral to the injury.However,PEG-fused rats exhibited significantly earlier return to baseline withdrawal thresholds than Negative Control rats.Furthermore,PEG-fused rats with significantly improved Sciatic Functional Index scores at or after 4 weeks postoperatively exhibited yet-earlier von Frey filament recove ry compared with those without Sciatic Functional Index recovery,suggesting a correlation between successful PEG-fusion and both motor-dominant and sensory-dominant behavioral recoveries.This correlation was independent of the sex or strain of the rat.Furthermore,our data showed that the acceleration of von Frey filament sensory recovery to baseline was solely due to the PEG-fused sciatic nerve and not saphenous nerve collateral outgrowths.No chronic hypersensitivity developed in any rat up to 12 weeks.All these data suggest that PEG-fusion repair of transection peripheral nerve injuries co uld have important clinical benefits. 展开更多
关键词 autophagia AXOTOMY collateral sprouting neuropathic pain peripheral nerve repair polyethylene glycol fusion(PEG-fusion) saphenous nerve sensory neurons sex and strain Wallerian degeneration
下载PDF
Polyethylene glycol fusion repair of severed rat sciatic nerves reestablishes axonal continuity and reorganizes sensory terminal fields in the spinal cord
3
作者 Emily A.Hibbard Liwen Zhou +5 位作者 Cathy Z.Yang Karthik Venkudusamy Yessenia Montoya Alexa Olivarez George D.Bittner Dale R.Sengelaub 《Neural Regeneration Research》 SCIE CAS 2025年第7期2095-2107,共13页
Peripheral nerve injuries result in the rapid degeneration of distal nerve segments and immediate loss of motor and sensory functions;behavioral recovery is typically poor.We used a plasmalemmal fusogen,polyethylene g... Peripheral nerve injuries result in the rapid degeneration of distal nerve segments and immediate loss of motor and sensory functions;behavioral recovery is typically poor.We used a plasmalemmal fusogen,polyethylene glycol(PEG),to immediately fuse closely apposed open ends of severed proximal and distal axons in rat sciatic nerves.We have previously reported that sciatic nerve axons repaired by PEG-fusion do not undergo Wallerian degeneration,and PEG-fused animals exhibit rapid(within 2–6 weeks)and extensive locomotor recovery.Furthermore,our previous report showed that PEG-fusion of severed sciatic motor axons was non-specific,i.e.,spinal motoneurons in PEG-fused animals were found to project to appropriate as well as inappropriate target muscles.In this study,we examined the consequences of PEG-fusion for sensory axons of the sciatic nerve.Young adult male and female rats(Sprague–Dawley)received either a unilateral single cut or ablation injury to the sciatic nerve and subsequent repair with or without(Negative Control)the application of PEG.Compound action potentials recorded immediately after PEG-fusion repair confirmed conduction across the injury site.The success of PEG-fusion was confirmed through Sciatic Functional Index testing with PEG-fused animals showing improvement in locomotor function beginning at 35 days postoperatively.At 2–42 days postoperatively,we anterogradely labeled sensory afferents from the dorsal aspect of the hindpaw following bilateral intradermal injection of wheat germ agglutinin conjugated horseradish peroxidase.PEG-fusion repair reestablished axonal continuity.Compared to unoperated animals,labeled sensory afferents ipsilateral to the injury in PEG-fused animals were found in the appropriate area of the dorsal horn,as well as inappropriate mediolateral and rostrocaudal areas.Unexpectedly,despite having intact peripheral nerves,similar reorganizations of labeled sensory afferents were also observed contralateral to the injury and repair.This central reorganization may contribute to the improved behavioral recovery seen after PEG-fusion repair,supporting the use of this novel repair methodology over currently available treatments. 展开更多
关键词 AXOTOMY dorsal horn peripheral nerve injury PLASTICITY polyethylene glycol(PEG) sciatic nerve sensory terminals wheat germ agglutinin horseradish peroxidase
下载PDF
Vertically aligned montmorillonite aerogel-encapsulated polyethylene glycol with directional heat transfer paths for efficient solar thermal energy harvesting and storage
4
作者 Qijing Guo Cong Guo +2 位作者 Hao Yi Feifei Jia Shaoxian Song 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期907-916,共10页
The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in mon... The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in montmorillonite aerogels(3D-Mt)through vacuum impregnation to prepare 3D-Mt/PEG composite PCMs.When used as a support matrix,3D-Mt can effectively prevent PEG leakage and act as a flame-retardant barrier to reduce the flammability of PEG.Simultaneously,3D-Mt/PEG demonstrates outstanding shape retention,increased thermal energy storage density,and commendable thermal and chemical stability.The phase transition enthalpy of 3D-Mt/PEG can reach 167.53 J/g and remains stable even after 50 heating-cooling cycles.Furthermore,the vertical sheet-like structure of 3D-Mt establishes directional heat transport channels,facilitating efficient phonon transfer.This configuration results in highly anisotropic thermal conductivities that ensure swift thermal responses and efficient heat conduction.This study addresses the shortcomings of PCMs,including the issues of leakage and inadequate flame retardancy.It achieves the development and design of 3D-Mt/PEG with ultrahigh strength,superior flame retardancy,and directional heat transfer.Therefore,this work offers a design strategy for the preparation of high-performance composite PCMs.The 3D-Mt/PEG with vertically aligned and well-ordered array structure developed in this research shows great potential for thermal management and photothermal conversion applications. 展开更多
关键词 montmorillonite aerogel polyethylene glycol phase change materials solar thermal energy storage flame retardant
下载PDF
Hyponatremic encephalopathy due to polyethylene glycol-based bowel preparation for colonoscopy:A case report 被引量:1
5
作者 Yuan Zhao Hai-Sheng Dong 《World Journal of Clinical Cases》 SCIE 2023年第1期187-192,共6页
BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause ... BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause electrolyte disturbances and hyponatremia.However,hyponatremic encephalopathy due to hyponatremia induced by PEG solution,although rare,can lead to serious irreversible sequelae and even death.CASE SUMMARY In this report,we discuss a case of neurological dysfunction due to hyponatremia,also known as hyponatremic encephalopathy,observed in a 63-year-old woman who underwent PEG-based bowel preparation for colonoscopy.She was eventually transferred to our intensive care unit for treatment due to her Glasgow Coma Scale score of 9/15(Eye opening 2;Verbal response 1;Motor response 6)and abnormal laboratory tests.CONCLUSION Physicians should be thoroughly familiarized with the patient’s history before prescribing PEG for bowel preparation,and timely identification of patients with hyponatremic encephalopathy is essential as delayed treatment is associated with poor neurological outcomes.An intravenous infusion of 3%sodium chloride is recommended at the onset of early symptoms.The goal of treatment is to adequately treat cerebral edema while avoiding serum sodium correction beyond 15 to 20 m Eq/L within 48 h of treatment to prevent osmotic demyelination syndrome. 展开更多
关键词 polyethylene glycol Intestinal preparation Hyponatremic encephalopathy HYPONATREMIA BRAIN Case report
下载PDF
Polyethylene glycol crosslinked decellularized single liver lobe scaffolds with vascular endothelial growth factor promotes angiogenesis in vivo
6
作者 Jian-Se Zhang Zhi-Bin Wang +5 位作者 Zhi-Zhen Lai Jing-Wen Yang Wen-Jing Song Yu-Bing Wei Jin Mei Jian-Guang Wang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2023年第6期622-631,共10页
Background: Improving the mechanical properties and angiogenesis of acellular scaffolds before transplantation is an important challenge facing the development of acellular liver grafts. The present study aimed to eva... Background: Improving the mechanical properties and angiogenesis of acellular scaffolds before transplantation is an important challenge facing the development of acellular liver grafts. The present study aimed to evaluate the cytotoxicity and angiogenesis of polyethylene glycol(PEG) crosslinked decellularized single liver lobe scaffolds(DLSs), and establish its suitability as a graft for long-term liver tissue engineering. Methods: Using mercaptoacrylate produced by the Michael addition reaction, DLSs were first modified using N-succinimidyl S-acetylthioacetate(SATA), followed by cross-linking with PEG as well as vascular endothelial growth factor(VEGF). The optimal concentration of agents and time of the individual steps were identified in this procedure through biomechanical testing and morphological analysis. Subsequently, human umbilical vein endothelial cells(HUVECs) were seeded on the PEG crosslinked scaffolds to detect the proliferation and viability of cells. The scaffolds were then transplanted into the subcutaneous tissue of Sprague-Dawley rats to evaluate angiogenesis. In addition, the average number of blood vessels was evaluated in the grafts with or without PEG at days 7, 14, and 21 after implantation. Results: The PEG crosslinked DLS maintained their three-dimensional structure and were more translucent after decellularization than native DLS, which presented a denser and more porous network structure. The results for Young’s modulus proved that the mechanical properties of 0.5 PEG crosslinked DLS were the best and close to that of native livers. The PEG-VEGF-DLS could better promote cell proliferation and differentiation of HUVECs compared with the groups without PEG cross-linking. Importantly, the average density of blood vessels was higher in the PEG-VEGF-DLS than that in other groups at days 7, 14, and 21 after implantation in vivo. Conclusions: The PEG crosslinked DLS with VEGF could improve the biomechanical properties of native DLS, and most importantly, their lack of cytotoxicity provides a new route to promote the proliferation of cells in vitro and angiogenesis in vivo in liver tissue engineering. 展开更多
关键词 DECELLULARIZATION Single liver lobe polyethylene glycol ANGIOGENESIS Liver tissue engineering
下载PDF
Anaphylactic shock induced by polyethylene glycol after bowel preparation for the colorectal cancer surgery:A case report
7
作者 Go Woon Park Nahyeon Park +2 位作者 Jung Cheol Kuk Eung Jin Shin Dae Ro Lim 《World Journal of Clinical Cases》 SCIE 2023年第23期5589-5594,共6页
BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although the... BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although they are still rare.This case report aims to raise awareness,that the commonly used bowel cleansing agent containing PEG can cause serious allergic reactions.CASE SUMMARY Prior to surgery for sigmoid colon cancer,a 63-year-old man was prescribed a bowel cleansing agent containing PEG.Within 30 min of ingestion,he developed symptoms of anaphylactic shock and did not respond to initial intramuscular epinephrine injection.Under diagnosis of anaphylaxis to PEG,he was stabilized with fluid hydration and continuous norepinephrine infusion.CONCLUSION While allergic reactions to PEG are rare,they can be life-threatening.Therefore,it is crucial for clinicians to be aware of this possibility and to diagnose and resuscitate patients immediately. 展开更多
关键词 polyethylene glycol ANAPHYLAXIS Sigmoid colon cancer Bowel preparation Case report
下载PDF
Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing 被引量:10
8
作者 Yoon Suk Jung Chang Kyun Lee +3 位作者 Hyo Jong Kim Chang Soo Eun Dong Soo Han Dong Ⅱ Park 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15845-15851,共7页
AIM: To compare efficacy, patient compliance, acceptability, satisfaction, safety, and adenoma detection rate of sodium phosphate tablets (NaP, CLICOLON<sup>TM</sup>) to a standard 4 L polyethylene glycol ... AIM: To compare efficacy, patient compliance, acceptability, satisfaction, safety, and adenoma detection rate of sodium phosphate tablets (NaP, CLICOLON<sup>TM</sup>) to a standard 4 L polyethylene glycol (PEG) solution for bowel cleansing for adults undergoing colonoscopy. 展开更多
关键词 Sodium phosphate tablets polyethylene glycol COLONOSCOPY Bowel preparation
下载PDF
Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy 被引量:7
9
作者 Takafumi Ito Ken Ohata +4 位作者 Akiko Ono Hideyuki Chiba Yosuke Tsuji Hajime Sato Nobuyuki Matsuhashi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第15期1789-1792,共4页
AIM:To prospectively confirm whether a small amount of polyethylene glycol(PEG)ingested after swallowing endoscopy capsule improves image quality and completion rate.METHODS:Forty-four consecutive patients referred to... AIM:To prospectively confirm whether a small amount of polyethylene glycol(PEG)ingested after swallowing endoscopy capsule improves image quality and completion rate.METHODS:Forty-four consecutive patients referred to us for capsule endoscopy(CE)were randomized to two groups.All patients were restricted to clear fluids for 12 h before the examination.Patients in group A(22 cases)received no additional preparation,while those in group B(20 cases)ingested 500 mL of PEG within a 2 h period starting 30 min after swallowing the capsule.Clear fluids and meals were allowed 2 h and 4 h after capsule ingestion,respectively.Image quality was assessed as the percentage of visualized bowel surface area as follows:1:<25%;2:25%-49%;3:50%-74%;4:75%-89%;5:>90%.The small bowel record was divided into five segments by time,and the score for each segment was evaluated.All CE examinations were performed with the Pillcam SB capsule endoscopy sys-tem(Given Imaging Co.Ltd.,Yoqnem).RESULTS:This study ended in December 2009,because sample size was considered large enough.A total of 44 patients were enrolled.Two patients in group B were excluded from the analysis because small bowel images could not be obtained from these patients;one had a full stomach,while the other presented with a massive gastric bleed.Thus,22 patients from group A and 20 patients from group B completed the study.There was no significant difference in age(P=0.22),sex(P=0.31),and indication for CE.No significant adverse events occurred in any of the study patients.In group A,image quality deteriorated as the capsule progressed distally.However,in group B,image quality was maintained to the distal small bowel.In each of the five segments,the visibility score was significantly higher in group B than in group A(segment 1:4.3± 0.7vs 4.7±0.5,P=0.03;segment 2:4.2±0.9vs 4.8 ±0.4,P=0.01;segment 3:4.0±1.0 vs 4.6±0.7,P =0.04;segment 4:3.6±1.1 vs 4.5±0.6,P=0.003;segment 5:2.7±1.0vs 4.4±0.8,P=0.00004).Thus,the use of PEG during CE examination significantly improved image quality in all time segments,and this effect was more pronounced in the distal ileum.The completion rate to the cecum was not significantly different between groups A and B(81.8%vs 85.0%,P =0.89).There was no difference in the gastric transit time between groups(36.2±35.0 min vs 54.0±56.6 min,P=0.23),but the small bowel transit time was significantly longer in group A than in group B(246.0± 107.0 minvs 171.0±104.0 min,P=0.04).CONCLUSION:The ingestion of a small amount of PEG after the swallowing of an endoscopy capsule significantly improved CE image quality,but did not enhance the completion rate to the cecum. 展开更多
关键词 Capsule endoscopy Completion rate Image quality polyethylene glycol PREPARATION
下载PDF
Split-dose vs same-day reduced-volume polyethylene glycol electrolyte lavage solution for morning colonoscopy 被引量:8
10
作者 Wah-Kheong Chan Najib Azmi +1 位作者 Sanjiv Mahadeva Khean-Lee Goh 《World Journal of Gastroenterology》 SCIE CAS 2014年第39期14488-14494,共7页
AIM: To compare same-day whole-dose vs split-dose of 2-litre polyethylene glycol electrolyte lavage solution (PEG-ELS) plus bisacodyl for colon cleansing for morning colonoscopy.
关键词 Bowel preparation COLONOSCOPY Split-dose polyethylene glycol electrolyte lavage solution
下载PDF
Polyethylene glycol rinse solution:An effective way to prevent ischemia-reperfusion injury 被引量:6
11
作者 Mohamed Amine Zaouali Mohamed Bejaoui +7 位作者 Maria Calvo Emma Folch-Puy Eirini Pantazi Gianfranco Pasut Antoni Rimola Hassen Ben Abdennebi René Adam Joan Roselló-Catafau 《World Journal of Gastroenterology》 SCIE CAS 2014年第43期16203-16214,共12页
AIM: To test whether a new rinse solution containing polyethylene glycol 35 (PEG-35) could prevent ischemia-reperfusion injury (IRI) in liver grafts.
关键词 Liver washout Liver transplantation Rinse solution Ischemia-reperfusion injury polyethylene glycol 35 Nitric oxide Adenosine monophosphate-activated protein kinase Heme oxygenase 1 Heat shock protein 70 METALLOPROTEINASES
下载PDF
Prospective randomized comparison of oral sodium phosphate and polyethylene glycol lavage for colonoscopy preparation 被引量:7
12
作者 Kai-Lin Hwang William Tzu-Liang Chen +4 位作者 Koung-Hong Hsiao Hong-Chang Chen Ting-Ming Huang Chien-Ming Chiu Ger-Haur Hsu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第47期7486-7493,共8页
AIM: To compare the effectiveness, patient acceptability, and physical tolerability of two oral lavage solutions prior to colonoscopy in a Taiwan Residents population. METHODS: Eighty consecutive patients were randomi... AIM: To compare the effectiveness, patient acceptability, and physical tolerability of two oral lavage solutions prior to colonoscopy in a Taiwan Residents population. METHODS: Eighty consecutive patients were randomized to receive either standard 4 L of polyethylene glycol (PEG) or 90 mL of sodium phosphate (NaP) in a split regimen of two 45 mL doses separated by 12 h, prior to colonoscopic evaluation. The primary endpoint was the percent of subjects who had completed the preparation. Secondary endpoints included colonic cleansing evaluated with an overall assessment and segmental evaluation, the tolerance and acceptability assessed by a selfadministered structured questionnaire, and a safety profile such as any unexpected adverse events, electrolyte tests, physical exams, vital signs, and body weights. RESULTS: A significantly higher completion rate was found in the NaP group compared to the PEG group(84.2% vs 27.5%, P<0.001). The amount of fluid suctioned was significantly less in patients taking NaP vs PEG (50.13±54.8 cc vs 121.13±115.4 cc, P<0.001),even after controlling for completion of the oral solution(P = 0.031). The two groups showed a comparable overall assessment of bowel preparation with a rate of 'good' or 'excellent' in 78.9% of patients in the NaPgroup and 82.5% in PEG group (P = 0.778). Patients taking NaP tended to have significantly better colonic segmental cleansing relative to stool amount observedin the descending (94.7% vs 70%, P = 0.007) andtransverse (94.6% vs 74.4%, P = 0.025) colon. Slightly more patients graded the taste of NaP as 'good' or 'very good' compared to the PEG patients (32.5% vs 12.5%;P = 0.059). Patients' willingness to take the same preparation in the future was 68.4% in the NaP compared to 75% in the PEG group (P = 0.617). There was a significant increase in serum sodium and a significant decrease in phosphate and chloride levels in NaP group on the day following the colonoscopy without any clinical sequelae. Prolonged (>24 h) hemodynamic changes were also observed in 20-35% subjects of either group.CONCLUSION: Both bowel cleansing agents proved to be similar in safety and effectiveness, while NaP appeared to be more cost-effective. After identifying and excluding patients with potential risk factors, sodium phosphate should become an alternative preparation for patients undergoing elective colonoscopy in the Taiwan Residents population. 展开更多
关键词 COLONOSCOPY Bowel preparation Sodium phosphate polyethylene glycol
下载PDF
Mica-stabilized polyethylene glycol composite phase change materials for thermal energy storage 被引量:7
13
作者 Dongyao Zhang Chuanchang Li +2 位作者 Niangzhi Lin Baoshan Xie Jian Chen 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2022年第1期168-176,共9页
Mica was used as a supporting matrix for composite phase change materials(PCMs)in this work because of its distinctive morphology and structure.Composite PCMs were prepared using the vacuum impregnation method,in whic... Mica was used as a supporting matrix for composite phase change materials(PCMs)in this work because of its distinctive morphology and structure.Composite PCMs were prepared using the vacuum impregnation method,in which mica served as the supporting material and polyethylene glycol(PEG)served as the PCM.Fourier transform infrared and X-ray diffraction analysis confirmed that the addition of PEG had no effect on the crystal structure of mica.Moreover,no chemical reaction occurred between PEG and mica during the vacuum impregnation process,and no new substance was formed.The maximum load of mica-stabilized PEG was 46.24%,the phase change temperature of M_(400)/PEG was 46.03℃,and the latent heat values of melting and cooling were 77.75 and 77.73 J·g^(−1),respectively.The thermal conductivity of M_(400)/PEG was 2.4 times that of pure PEG.The thermal infrared images indicated that the thermal response of M_(400)/PEG improved relative to that of pure PEG.The leakage test confirmed that mica could stabilize PEG and that M_(400)/PEG had great form-stabilized property.These results demonstrate that M_(400)/PEG has potential in the field of building energy conservation. 展开更多
关键词 MICA polyethylene glycol phase change materials thermal energy storage
下载PDF
Rheological behavior of fumed silica suspension in polyethylene glycol 被引量:7
14
作者 伍秋美 阮建明 +2 位作者 黄伯云 周忠诚 邹俭鹏 《Journal of Central South University of Technology》 EI 2006年第1期1-5,共5页
The rheological behavior of fumed silica suspensions in polyethylene glycol(PEG) was studied at steady and oscillatory shear stress using AR 2000 stress controlled rheometer. The systems show reversible shear thickeni... The rheological behavior of fumed silica suspensions in polyethylene glycol(PEG) was studied at steady and oscillatory shear stress using AR 2000 stress controlled rheometer. The systems show reversible shear thickening behavior and the shear-thickening behavior can be explained by the clustering mechanism. The viscosity and the degree of shear-thickening of the systems strongly depend on the mass fraction of the silica, the molecular weigh of PEG and the frequency used in the rheological measurement. The silica volume fraction of the systems is 1.16% 3.62%, corresponding to the mass fraction of 4%9%. The shear-thickening taking place in the low volume fraction may contribute to the fractal nature of the silica. At oscillatory shear stress, when the shear stress is less than the critical stress, the storage modulus decreases significantly, meanwhile the loss modulus and the complex viscosity almost remain unchanged; when the shear stress is larger than the critical stress, the storage modulus, the loss modulus and the complex viscosity increase with the increase of shear stress. The loss modulus is larger than the storage modulus in the range of stress studied and both moduli depend on frequency. 展开更多
关键词 fumed silica suspension polyethylene glycol SHEAR-THICKENING storage modulus loss modulus
下载PDF
Polyethylene glycol (PEG) as a benign solvent for Knoevenagel condensation 被引量:7
15
作者 Yang Liu Jun Liang Xiu Hong Liu Ji Cai Fan Zhi Cai Shang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第9期1043-1046,共4页
The Knoevenagel condensation of aromatic aldehydes with active methylene compound proceeded efficiently in polyethylene glycol at room temperature with L-proline as catalyst. The yield is high and the products had E-i... The Knoevenagel condensation of aromatic aldehydes with active methylene compound proceeded efficiently in polyethylene glycol at room temperature with L-proline as catalyst. The yield is high and the products had E-isomer dominantly. Polyethylene glycol containing L-proline could be recycled and reused for several times without noticeably decreasing in productivity. 展开更多
关键词 polyethylene glycol L-PROLINE Knoevenagel condensation
下载PDF
Conundrums and confusions regarding how polyethylene glycol-fusion produces excellent behavioral recovery after peripheral nerve injuries 被引量:4
16
作者 George D.Bittner Dale R.Sengelaub Cameron L.Ghergherehchi 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第1期53-57,共5页
Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 ... Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 days) degeneration of severed distal axons, muscle atrophy, and poor behavioral recovery after many months (if ever, after ablations) by slowly-regenerating (1 mm/d), proximal-stump outgrowths that must specifically reinnervate denervated targets; (3) Poor acceptance of microsutured nerve allografts, even if tissue-matched and immune-suppressed. Repair of transections/ablations by neurorrhaphy and well-specified-sequences of PEG-fusion solutions (one containing polyethylene glycol, PEG) successfully address these problems. However, conundrums and confusions regarding unorthodox and dramatic results of PEG-fusion repair in animal model systems often lead to misunderstandings. For example, (1) Axonal continuity and signaling is re-established within minutes by non-specifically PEG-fusing (connecting) severed motor and sensory axons across each lesion site, but remarkable behavioral recovery to near-unoperated levels takes several weeks; (2) Many distal stumps of inappropriately-reconnected, PEG-fused axons do not ever (Wallerian) degenerate and continuously innervate muscle fibers that undergo much less atrophy than otherwise-denervated muscle fibers; (3) Host rats do not reject PEG-fused donor nerve allografts in a non-immuno-privileged environment with no tissue matching or immunosuppression; (4) PEG fuses apposed open axonal ends or seals each shut (thereby preventing PEG-fusion), depending on the experimental protocol; (5) PEG-fusion protocols produce similar results in animal model systems and early human case studies. Hence, iconoclastic PEG-fusion data appropriately understood might provoke a re-thinking of some Neuroscience dogma and a paradigm shift in clinical treatment of peripheral nerve injuries. 展开更多
关键词 axonal repair AXOTOMY Wallerian degeneration polyethylene glycol ALLOGRAFT AUTOGRAFT nerve regeneration
下载PDF
Polyethylene glycol microspheres loaded with irinotecan for arterially directed embolic therapy of metastatic liver cancer 被引量:6
17
作者 Giammaria Fiorentini Riccardo Carandina +9 位作者 Donatella Sarti Michele Nardella Odysseas Zoras Stefano Guadagni Riccardo Inchingolo Massimiliano Nestola Alessandro Felicioli Daniel Barnes Navarro Fernando Munoz Gomez Camillo Aliberti 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2017年第9期379-384,共6页
AIM To study tumor response, and tolerability of arterially directed embolic therapy(ADET) with polyethylene glycol embolics loaded with irinotecan for the treatment of colorectal cancer liver metastases(CRC-LM). Seco... AIM To study tumor response, and tolerability of arterially directed embolic therapy(ADET) with polyethylene glycol embolics loaded with irinotecan for the treatment of colorectal cancer liver metastases(CRC-LM). Secondary objectives were to monitor quality of life, time to progression and survival of patients.METHODS Patients were included in the study if they were affected by CRC-LM, refractory to systemic chemotherapy, treated with ADET using polyethylene glycol embolics, and had liver involvement < 50%. Tumor response, performance status(PS), tumor marker antigens, and quality of life(QoL) were monitored at 1, 3 and 6 mo after ADET. QoL was assessed with the Palliative Performance Scale(PPS).RESULTS We treated 50 consecutive CRC-LM patients with ADET using polyethylene glycol embolics. Their tumor response one month after ADET was: 28% of complete response(CR), 48% of partial response(PR), 8% stable disease(SD), and 16% of progression. Tumor response 3 mo after ADET was CR 24%, PR 38%, SD 19% and progression disease(PD) 19%. Tumor response 6 mo after ADET was CR 18%, PR 44%, SD 21% and PD 18%. QoL was 90% PPS at each time point. Median time to progression for patients who progressed was 2.5 mo(range 0.8-6). Median follow-up was 14 mo(0.8-25 range). ADETs were performed with no complications. Observed side effects(mild or moderate intensity) were: Pain in 32% of patients, increase of transaminase levels in 20% and fever in 14%, whereas 30% of patients did not complain any adverse event. CONCLUSION The treatment of unresectable CRC-LM with ADET using polyethylene glycol microspheres loaded with irinotecan was effective in tumor response and resulted in mild toxicity, and good QoL. 展开更多
关键词 Liver metastases Arterially directed embolic therapy Colorectal cancer polyethylene glycol embolics IRINOTECAN
下载PDF
Noninferiority clinical trial comparing the bowel cleansing efficacy of sodium phosphate tablets(Quiklean®)with a polyethylene glycol/bisacodyl kit 被引量:5
18
作者 Shih-Ya Hung Hung-Chang Chen +10 位作者 Tao-Wei Ke Jiann-Hwa Chen Koung-Hung Hsiao Hwei-Ming Wang Hua-Che Chiang Sheng-Chi Chang Yi-Chang Chen Ming-Hao Hsieh Yuan-Yao Tsai Yo-Wen Hsieh William Tzu-Liang Chen 《World Journal of Gastroenterology》 SCIE CAS 2021年第5期428-441,共14页
BACKGROUND Efficient bowel cleansing is essential for a successful colonoscopy,but the ideal cleansing agent,volume,and pharmaceutical dosage form have yet to be determined.Small-volume cleansers enhance patient compl... BACKGROUND Efficient bowel cleansing is essential for a successful colonoscopy,but the ideal cleansing agent,volume,and pharmaceutical dosage form have yet to be determined.Small-volume cleansers enhance patient compliance.AIM To compare the bowel cleansing efficacy of 32-tablet sodium phosphate(Quiklean®)with 2-L polyethylene glycol(PEG)/bisacodyl(Klean-Prep/Dulcolax®)under identical dietary recommendations.METHODS This multicenter,randomized,parallel-group,noninferiority clinical trial enrolled 472 outpatients,randomized 456 subjects,and scheduled 442 subjects to undergo colonoscopy(Quiklean®=222 and Klean-Prep/Dulcolax®=220).After bowel preparation,a colonoscopist performed the colonoscopy with video recorded for rating.The primary efficacy endpoint was the bowel cleansing quality using the Aronchick Scale.The secondary endpoints were the bowel cleansing efficacy of three colon segments,tolerability and acceptability,safety using the Ottawa bowel preparation scale,questionnaires by subjects,and monitoring of adverse events.RESULTS Success rates(Excellent+Good)of the bowel cleansing quality by Aronchick Scale were 98.6%(n=205)and 97.6%(n=204)in the Quiklean®and Klean-Prep/Dulcolax®groups,respectively.Quiklean®demonstrated noninferiority over Klean-Prep/Dulcolax®in colon cleansing efficacy.Quicken showed better tolerability and acceptability in the overall experience(was rated as excellent;24.0%vs 17.2%;P=0.0016)and the taste of the study preparation(was rated as excellent,23.1%vs 13.4%;P<0.0001)than Klean-Prep/Dulcolax®.Safety profiles did not differ between the two groups.Our data indicate that Quiklean®is an adequate,well-tolerated bowel cleansing preparation compared with the standard comparator Klean-Prep/Dulcolax®.CONCLUSION Quiklean®is sodium phosphate tablets available on Taiwan’s market for bowel preparation;it potentially offers patients an alternative to standard large-volume bowel preparation regimens and may,therefore,increase positive attitudes toward colonoscopies and participation rates. 展开更多
关键词 Bowel preparation Clinical trial COLONOSCOPY polyethylene glycol Sodium phosphate
下载PDF
Synthesis and Characterization of Storage Energy Materials Prepared from Nano-crystalline Cellulose/Polyethylene Glycol 被引量:5
19
作者 Xiao Ping YUAN En Yong DING 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1129-1132,共4页
This paper gives a brief report of the synthesis of a new kind of solid-solid phase change materials (SSPCMs), nano-crystalline cellulose/polyethylene glycol (NCC/PEG). These PCMs have very high ability for energy... This paper gives a brief report of the synthesis of a new kind of solid-solid phase change materials (SSPCMs), nano-crystalline cellulose/polyethylene glycol (NCC/PEG). These PCMs have very high ability for energy storage, and their enthalpies reach 103.8 J/g. They are composed of two parts, PEG as functional branches for energy storage, and NCC as skeleton. The flexible polymer PEG was grafted onto the surface of rigid powder of NCC by covalent bonds. The results of DSC, FT-IR were briefly introduced, and some comments were also given. 展开更多
关键词 Nano-crystalline cellulose (NCC) polyethylene glycol (PEG) phase change materials(PCM) energy storage DSC.
下载PDF
Preparation and Hydrophilicity of Copolymerization of Chitosan Selectively Grafted by Polyethylene Glycol 被引量:3
20
作者 李若慧 SHAN Dantong DU Ying 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第2期334-338,共5页
Copolymerization of chitosan selectively grafted by polyethylene glycol was prepared. Chitosan was selectively grafted by monomethoxy polyethylene glycol(mPEG-OH), which contained a hydroxyl group combining with hex... Copolymerization of chitosan selectively grafted by polyethylene glycol was prepared. Chitosan was selectively grafted by monomethoxy polyethylene glycol(mPEG-OH), which contained a hydroxyl group combining with hexamethylene diisocyanate(HDI) to form a novel macromonomer namely monomethoxy polyethylene glycol isocyanate(mPEG-NCO) containing a isocyanate group with higher chemical activity in ethyl glyoxalate solution absolutely without water. The selective grafted copolymerization of Chitosan with mPEG-NCO was conducted under heterogeneous conditions as suspension in dimethylformamide. The hydrophilic copolymers of chitosan were prepared by condensation reaction of isocyanate group on mPEG- NCO with hydroxy groups on chitosan chains because amino groups on chitosan chains were protected by complexion formation with copper ions. The effect of reaction condition on the grafting extents was discussed. Swelling properties of mPEG-g-CS were researched. The graft copolymer mPEG-g-CS was characterized by the infrared spectra. The experimental result showed that the copper ions were very effective to protect amino groups from condensation reaction. The swelling degree in water increases with adding of grafting ratio. The maximum swelling degree was up to above 132% when the grafting ratio was about 270%. The graft copolymer can be soluble partially in pure water. 展开更多
关键词 CHITOSAN polyethylene glycol selectively graft grafting ratio HYDROPHILICITY swelling properties
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部