Development of a portable reflectance confocal microscope and its application in the noninvasive in vivo evaluation of mesenchymal stem cell-promoted cutaneous wound healing
1
作者 Lixing Zhang Xin Miao +6 位作者 Meijia Wang Aihua Shi Jingwen Wang Zhonglin Ma Yunhai Zhang Jingzhong Zhang Shuang Yu 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2023年第3期268-283,共16页
The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging... The process of wound healing is routinely evaluated by histological evaluation in the clinic,which may cause scarring and secondary injury.Reflectance confocal microscopy(RCM)represents a noninvasive,real-time imaging technique that allows in vivo evaluation of the skin.Traditional RCM was wide-probe-based,which limited its application on uneven and covered skin.In this study,we report the development of a portable reflectance confocal microscope(PRCM)in which all components were assembled in a handheld shell.Although the size and weight of the PRCM were reduced based on the use of a microelectromechanical system,the resolution was kept at 0.91μm,and the field of view of the system was 343μm×532μm.When used in vivo,the PRCM was able to visualize cellular and nuclear morphology for both mouse and human skin.PRCM evaluations were then performed on wounds after topically applied mesenchymal stem cells(MSCs)or saline treatment.The PRCM allowed visualization of the formation of collagen bundles,re-epithelization from the wound edge to the wound bed,and hair follicle regeneration,which were consistent with histological evaluations.Therefore,we offer new insights into monitoring the effects of topically applied MSCs on the process of wound healing by using PRCM.This study illustrates that the newly developed PRCM represents a promising device for real-time,noninvasive monitoring of the dynamic process of wound healing,which demonstrates its potential to diagnose,monitor,or predict disease in clinical wound therapy. 展开更多
关键词 portable reflectance confocal microscope Wound healing Noninvasive optical imaging Real-time in vivo visualization
下载PDF
Thermoacoustic imaging:From single-element scanning to portable and array-based imaging
2
作者 Yi-Jie Huang Qi-Kai-Yu Feng Lin Huang 《Journal of Electronic Science and Technology》 EI CAS CSCD 2023年第3期1-20,共20页
The microwave-induced thermoacoustic imaging(TAI)technology has both the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging(UI),so it has carried out exploratory application res... The microwave-induced thermoacoustic imaging(TAI)technology has both the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging(UI),so it has carried out exploratory application research in various areas,such as the early detection of breast tumors and cerebrovascular diseases.However,the microwave generator used in the traditional TAI technology is huge and expensive,and the temporal resolution is also too low due to the single-element scanning mechanism.Thus,it is difficult to meet the needs of clinical applications.In this paper,the iterative process and the analysis of related application scenarios from single-element scanning to portable and array-based TAI,such as the miniaturized microwave generator,handheld antenna,multi-channel data acquisition,and UI/TAIdual-modality imaging,are reviewed,and the future trends of this technology are discussed.This review helps researchers in the field of TAI learn the technological development process and future trends.It also deepens clinicians’understanding of TAI so as to put forward more application requirements. 展开更多
关键词 Array-based portable Single-element scanning Thermoacoustic imaging(TAI)
下载PDF
Portable FBAR based E-nose for cold chain real-time bananas shelf time detection
3
作者 Chen Wu Jiuyan Li 《Nanotechnology and Precision Engineering》 CAS CSCD 2023年第1期32-39,共8页
Being cheap,nondestructive,and easy to use,gas sensors play important roles in the food industry.However,most gas sensors are suitable more for laboratory-quality fast testing rather than for cold-chain continuous and... Being cheap,nondestructive,and easy to use,gas sensors play important roles in the food industry.However,most gas sensors are suitable more for laboratory-quality fast testing rather than for cold-chain continuous and cumulative testing.Also,an ideal electronic nose(E-nose)in a cold chain should be stable to its surroundings and remain highly accurate and portable.In this work,a portable film bulk acoustic resonator(FBAR)-based E-nose was built for real-time measurement of banana shelf time.The sensor chamber to contain the portable circuit of the E-nose is as small as a smartphone,and by introducing an air-tight FBAR as a reference,the E-nose can avoid most of the drift caused by surroundings.With the help of porous layer by layer(LBL)coating of the FBAR,the sensitivity of the E-nose is 5 ppm to ethylene and 0.5 ppm to isoamyl acetate and isoamyl butyrate,while the detection range is large enough to cover a relative humidity of 0.8.In this regard,the E-nose can easily discriminate between yellow bananas with green necks and entirely yellow bananas while allowing the bananas to maintain their biological activities in their normal storage state,thereby showing the possibility of real-time shelf time detection.This portable FBAR-based E-nose has a large testing scale,high sensitivity,good humidity tolerance,and low frequency drift to its surroundings,thereby meeting the needs of cold-chain usage. 展开更多
关键词 Film bulk acoustic resonator(FBAR) portable E-nose Real-time detection Layer by layer
下载PDF
Impact of Portable Executable Header Features on Malware Detection Accuracy
4
作者 Hasan H.Al-Khshali Muhammad Ilyas 《Computers, Materials & Continua》 SCIE EI 2023年第1期153-178,共26页
One aspect of cybersecurity,incorporates the study of Portable Executables(PE)files maleficence.Artificial Intelligence(AI)can be employed in such studies,since AI has the ability to discriminate benign from malicious... One aspect of cybersecurity,incorporates the study of Portable Executables(PE)files maleficence.Artificial Intelligence(AI)can be employed in such studies,since AI has the ability to discriminate benign from malicious files.In this study,an exclusive set of 29 features was collected from trusted implementations,this set was used as a baseline to analyze the presented work in this research.A Decision Tree(DT)and Neural Network Multi-Layer Perceptron(NN-MLPC)algorithms were utilized during this work.Both algorithms were chosen after testing a few diverse procedures.This work implements a method of subgrouping features to answer questions such as,which feature has a positive impact on accuracy when added?Is it possible to determine a reliable feature set to distinguish a malicious PE file from a benign one?when combining features,would it have any effect on malware detection accuracy in a PE file?Results obtained using the proposed method were improved and carried few observations.Generally,the obtained results had practical and numerical parts,for the practical part,the number of features and which features included are the main factors impacting the calculated accuracy,also,the combination of features is as crucial in these calculations.Numerical results included,finding accuracies with enhanced values,for example,NN_MLPC attained 0.979 and 0.98;for DT an accuracy of 0.9825 and 0.986 was attained. 展开更多
关键词 AI driven cybersecurity artificial intelligence CYBERSECURITY Decision Tree Neural Network Multi-Layer Perceptron Classifier portable executable(PE)file header features
下载PDF
In Search of Portable Water Supplies within a Brine and Mine Water-Invaded Region for Serving Some Communities around Ishiagu, Afikpo and Environs in Abakaliki Basin, Southeast Nigeria
5
作者 Charles Chibueze Ugbor 《International Journal of Geosciences》 CAS 2023年第2期209-225,共17页
The study investigates the hydrogeochemical characteristics of some towns in the Abakaliki Basin, comprising, Ishiagu, Aka Eze, Amaseri, Afikpo and Okposi communities, with the aim of sourcing for portable water in th... The study investigates the hydrogeochemical characteristics of some towns in the Abakaliki Basin, comprising, Ishiagu, Aka Eze, Amaseri, Afikpo and Okposi communities, with the aim of sourcing for portable water in the area. The basin is underlain by Albian sediments, essentially shales, in the lowlands, which were affected by low-grade metamorphism that had produced slates. The highlands comprise basic intrusives from episodes of magmatism and metallic ore mineralisation. Injection of brines into the aquifer system and low, seasonal aquifer recharge from rainfall results in poor water quality in the area. The study analyzes the geochemical distribution in water sources in the area and identifies sources of pollutants to guide the better choice of portable water. Results of hydrogeochemical analysis of both surface and groundwater from the communities were compared with World Health Organization to identify portable water locations in the area. While the salt lake at Okposi is the main source of brine intrusion in the study area, the Pb/Zn mine at Ishiagu is the main source of mine-water pollution in the study area. Most chemical parameters, (especially Cl<sup>-</sup>, Na<sup>+</sup>, Ca<sup>2+</sup>, Mg<sup>2+</sup>, SO<sub>4</sub><sup>2-</sup>, HCO<sub>3</sub><sup>-</sup>) maintain high concentrations within the salt lake area, with the values declining away from the salt lake. The main anthropogenic source of pollution in the area, especially at Ishiagu, is the indiscriminate surface mining of lead-zinc without proposer waste management practices. Possible sourcing for portable water in the study area includes a deep borehole at Ishiagu, away from lead-zinc intrusives. At the Okposi axis, searching for portable water in boreholes should target shallower aquifers that do not communicate with the deeper-seated brine zones, likewise targeting zones farther away from these brine-invaded areas. A controlled pumping rate could potentially ensure that the cone of depression was not low enough to reach the brine zone at depth. In addition, desalination could also potentially render the salt water drinkable if properly handled to eliminate the high concentration of salts in the water to the level of acceptable limit by the WHO. Based on the study, the best area to target for portable water in the study area is Afikpo, with most geochemical elements naturally occurring within WHO’s standard concentration while portable water could be harnessed in areas further away from mining sites, especially at deep groundwater. 展开更多
关键词 Abakaliki Basin portable Water Brine Aquifer Salt Lake Pollution Desaline Water
下载PDF
Portable System for CWA Detection Using Micro Array Gas Sensor 被引量:4
6
作者 J.H.Kwak Y.T.Lim +6 位作者 G.H.Kim N.J.Choi H.D.Park G.H.Rue J.S.Huh J.C.Kim D.D.Lee 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期124-128,共5页
Biochemistry weapon is raising new tools of war and terror.This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system.CWAs were divided into four typ... Biochemistry weapon is raising new tools of war and terror.This research is an experiment about portable system for CWAs (chemical warfare agents) detection using micro array gas system.CWAs were divided into four types such as blood, nerve,vesicant,and choking agent.To detect various CWAs,semiconductor thick film sensor array based on tin oxide was fabricated and their gas responses were examined.Operating temperature was range of 250℃to 350℃and gas concentration was range of 0.1μg/g to 10μg/g.Sensor array was measured as operating temperatures,concentrations for four simulant agents of CWAs.Extracted parameters from results were carried out classification among CWAs through the principal component analysis (PCA).Also,classification of gases is studied using adaptive resonance theory (ART) that is one of neural network algorithm.Results displayed using PDA system. 展开更多
关键词 SNO2 chemical warfare agents(CWAs) portable system ART ARRAY PCA
下载PDF
An Information Hiding Algorithm Based on Bitmap Resource of Portable Executable File 被引量:2
7
作者 Jie Xu Li-Jun Feng Ya-Lan Ye Yue Wu 《Journal of Electronic Science and Technology》 CAS 2012年第2期181-184,共4页
An information hiding algorithm is proposed, which hides information by embedding secret data into the palette of bitmap resources of portable executable (PE) files. This algorithm has higher security than some trad... An information hiding algorithm is proposed, which hides information by embedding secret data into the palette of bitmap resources of portable executable (PE) files. This algorithm has higher security than some traditional ones because of integrating secret data and bitmap resources together. Through analyzing the principle of bitmap resources parsing in an operating system and the layer of resource data in PE files, a safe and useful solution is presented to solve two problems that bitmap resources are incorrectly analyzed and other resources data are confused in the process of data embedding. The feasibility and effectiveness of the proposed algorithm are confirmed through computer experiments. 展开更多
关键词 Bitmap resources data embedding information hiding portable executable file.
下载PDF
Use of portable X-ray fluorescence in the analysis of surficial sediments in the exploration of hydrothermal vents on the Southwest Indian Ridge 被引量:5
8
作者 LIAO Shili TAO Chunhui +3 位作者 LI Huaiming ZHANG Guoyin LIANG Jin YANG Weifang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第7期66-76,共11页
Hydrothermal plumes released from the eruption of sea floor hydrothermal fluids contain large amounts of oreforming materials. They precipitate within certain distances from the hydrothermal vent. Six surficial sedime... Hydrothermal plumes released from the eruption of sea floor hydrothermal fluids contain large amounts of oreforming materials. They precipitate within certain distances from the hydrothermal vent. Six surficial sediment samples from the Southwest Indian Ridge(SWIR) were analyzed by a portable X-ray fluorescence(PXRF) analyzer on board to find a favorable method fast and efficient enough for sea floor sulfide sediment geochemical exploration. These sediments were sampled near, at a moderate distance from, or far away from hydrothermal vents. The results demonstrate that the PXRF is effective in determining the enrichment characteristics of the oreforming elements in the calcareous sediments from the mid-ocean ridge. Sediment samples(〉40 mesh) have high levels of elemental copper, zinc, iron, and manganese, and levels of these elements in sediments finer than 40 mesh are lower and relatively stable. This may be due to relatively high levels of basalt debris/glass in the coarse sediments, which are consistent with the results obtained by microscopic observation. The results also show clear zoning of elements copper, zinc, arsenic, iron, and manganese in the surficial sediments around the hydrothermal vent. Sediments near the vent show relatively high content of the ore-forming elements and either high ratios of copper to iron content and zinc to iron content or high ratios of copper to manganese content and zinc to manganese content. These findings show that the content of the ore-forming elements in the sediments around hydrothermal vents are mainly influenced by the distance of sediments to the vent, rather than grain size. In this way, the PXRF analysis of surface sediment geochemistry is found to satisfy the requirements of recognition geochemical anomaly in mid-ocean ridge sediments. Sediments with diameters finer than 40 mesh should be used as analytical samples in the geochemical exploration for hydrothermal vents on mid-oceanic ridges. The results concerning copper, zinc, arsenic, iron, and manganese and their ratio features can be used as indicators in sediment geochemical exploration of seafloor sulfides. 展开更多
关键词 mid-ocean ridge sediments hydrothermal activity portable X-ray fluorescence geochemical exploration
下载PDF
Portable and automated analyzer for rapid and high precision in vitro dissolution of drugs 被引量:1
9
作者 Zhongmei Chi Siqi Zhao +2 位作者 Xiujun Cui Yunxiang Feng Li Yang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第4期490-498,共9页
We developed a novel portable and automated dissolution test analyzer for rapid and high precision in vitro dissolution testing of drugs.The analyzer consists of a flow-through-cell drug dissolution system,an automate... We developed a novel portable and automated dissolution test analyzer for rapid and high precision in vitro dissolution testing of drugs.The analyzer consists of a flow-through-cell drug dissolution system,an automated sequential sampling system,a high-speed capillary electrophoresis(HSCE)system,and a data acquisition system.Combining the high-temporal resolution flow-gating sampling approach with HSCE,which has outstanding advantages of efficient separation and resolution,the analyzer can achieve rapid analysis and exhibits the ability in miniaturization for on-site assessment of different active pharmaceutical ingredients.To integrate the flow-through-cell dissolution system with HSCE,a specially designed flow-gating-injection(FGI)interface was employed.The performance of the analyzer was investigated by analyzing the dissolution of immediate-release drugs including single dose(amoxicillin dispersible tablets)and fixed dose combination(amoxicillin and clavulanate potassium)drug tablets with the high-temporal resolutions of 12 s and 20 s,respectively.The dissolution profiles of different active pharmaceutical ingredients could be simultaneously and automatically monitored with high repeatability and accuracy.The analyzer was successfully utilized for the pharmaceutical quality control and bio-relevant dissolution testing,as well as in vivo-in vitro correlation analysis.Our portable analyzer is miniaturized,convenient and of low-cost,and will provide a valuable tool for dissolution testing in pharmaceutical research and development. 展开更多
关键词 Dissolution test analyzer portable AUTOMATED Immediate-release drug Fixed dose combination drug
下载PDF
Occlusion of the middle cerebral artery Guidance by screen imaging using an EDA-H portable medium-soft electronic endoscope 被引量:1
10
作者 Xingbao Zhu Junli Luo +3 位作者 Song Liu Dongping Li Min Li Quanshui Fan 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第23期1806-1809,共4页
The present study aimed to verify the practicability of performing screen-based surgical operations under the guidance of a real-time viewing and recording system (RTVRS) using a portable medium-soft electronic endo... The present study aimed to verify the practicability of performing screen-based surgical operations under the guidance of a real-time viewing and recording system (RTVRS) using a portable medium-soft electronic endoscope (pmsEE). The middle cerebral artery in rats was occluded under screen-imaging guidance using a pmsEE RTVRS to reproduce an animal model of human cerebral infarction. The screen imaging of the pmsEE RTVRS was clear, life-like, stereoscopic and synchronous with the actual operation. Screen-imaging guidance led to an accurate, smooth, minimally invasive and comparatively easy surgical procedure. The surgical success rate, time of model establishment, neurological function scores, and infarct volume were similar to those using an operating microscope. These results indicate that the self-designed pmsEE RTVRS could be utilized for portable endoscopic screen-based surgical operations. 展开更多
关键词 portable medium-soft endoscope screen-based surgical operation occlusion of middle cerebral artery cerebral infarction
下载PDF
Collecting Traffic Video Data Using Portable Poles: Survey, Proposal, and Analysis 被引量:2
11
作者 Morten B. Jensen Chris H. Bahnsen +2 位作者 Harry S. Lahrmann Tanja K. O. Madsen Thomas B. Moeslund 《Journal of Transportation Technologies》 2018年第4期376-400,共25页
Several initiatives have been launched to help prevention of traffic accidents and near-accidents across the European Union. To aid the overall goal of reducing deaths and injuries related to traffic, one must underst... Several initiatives have been launched to help prevention of traffic accidents and near-accidents across the European Union. To aid the overall goal of reducing deaths and injuries related to traffic, one must understand the causation of the traffic accidents in order to prevent them. Rather than deploying a person to physically monitor a location, the task is eased by camera equipment installed in existing infrastructure, e.g. poles, and buildings, etc. In rural areas there is however a very limited infrastructure available which complicates the data acquisition. But even if there is infrastructure available in either the rural area or the urban area, this might not serve as an ideal position to capture video data from. In this work, we survey and provide an overview of available and relevant portable poles setups with respect to capturing data in both urban areas and rural areas. The conclusion of the survey shows a lack of a mobile, lightweight, compact, and easy deployable portable pole. We therefore design and develop a new portable pole meeting these requirements. The new proposed portable pole can be deployed by 2 persons in 2 hours in both rural areas as well as urban areas due to its compactness. The deployment and usage of the new portable pole is a complimentary tool, which may improve the camera capturing angle in case existing infrastructure is insufficient. This ultimately improves the traffic monitoring opportunities. Further, the survey of selected portable poles provides an excellent overview and can aid multiple applications within road traffic. 展开更多
关键词 Road TRAFFIC Video ANALYSIS Camera Mounting Pole portable
下载PDF
Real-Time Black Carbon Emissions from Light-Duty Passenger Vehicles Using a Portable Emissions Measurement System 被引量:1
12
作者 Xuan Zheng Liqiang He +4 位作者 Xiaoyi He Shaojun Zhang Yihuan Cao Jiming Hao Ye Wu 《Engineering》 SCIE EI CAS 2022年第9期73-81,共9页
Black carbon(BC)is considered the second largest anthropogenic climate forcer,but the radiative effects of BC are highly correlated with its combustion sources.On-road vehicles are an important source of anthropogenic... Black carbon(BC)is considered the second largest anthropogenic climate forcer,but the radiative effects of BC are highly correlated with its combustion sources.On-road vehicles are an important source of anthropogenic BC.However,there are major uncertainties in the estimates of the BC emissions from on-road light-duty passenger vehicles(LDPVs),and results obtained with the portable emissions measurement system(PEMS)method are particularly lacking.We developed a PEMS platform and evaluated the on-road BC emissions from ten in-use LDPVs.We demonstrated that the BC emission factors(EFs)of gasoline direction injection(GDI)engine vehicles range from 1.10 to 1.56 mg.km^(-1),which are higher than the EFs of port fuel injection(PFI)engine vehicles(0.10–0.17 mg.km^(-1))by a factor of 11.The BC emissions during the cold-start phase contributed 2%–33%to the total emissions.A strong correlation(R^(2)=0.70)was observed between the relative BC EFs and average vehicle speed,indicating that traffic congestion alleviation could effectively mitigate BC emissions.Moreover,BC and particle number(PN)emissions were linearly correlated(R^(2)=0.90),and compared to PFI engine vehicles,the instantaneous PN-to-BC emission rates of GDI engine vehicles were less sensitive to vehicle specific power-to-velocity(VSPV)increase in all speed ranges. 展开更多
关键词 Black carbon Light-duty gasoline vehicles portable emissions measurement system Real-time emissions
下载PDF
Automatic Measurement of Fetal Abdominal Biometric Parameters—Feasibility on a Portable Ultrasound Device 被引量:1
13
作者 Naiad Hossain Khan Eva Tegnander +4 位作者 Sigurd Storve Johan Morten Dreier Sturla Eik-Nes Hans Torp Gabriel Kiss 《Open Journal of Obstetrics and Gynecology》 2017年第8期922-936,共15页
An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, t... An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, the location of fetal abdomen is detected by image processing. Thereafter, an active contour model is converged along the abdominal boundary for measurement purposes. The validation data set contained 310 images of fetuses with gestational age (GA) from 14 to 41 weeks. The measurement success rate was 88.1%. By manually indicating the location of the abdomen, the success rate was further improved to 95.8% for the failed cases. The correlation between manual and automatic measurements was 0.95 and the intraclass correlation coefficient (ICC) was 0.976 (95% confidence interval (CI);0.969 - 0.981). The average method execution time was 0.3 s. The mean error was lower in young fetuses (0.4%) than in older fetuses (-2.1%). The proposed cross-platform method was implemented on a portable, low-cost ultrasound machine prototype targeted for low- and middle-income countries (LMIC);the results achieved were comparable to those of other state-of-the-art automatic methods. 展开更多
关键词 portable ULTRASOUND Scanner AUTOMATIC Measurement Mean ABDOMINAL Diameter ABDOMINAL CIRCUMFERENCE PRENATAL ULTRASOUND ICT4D
下载PDF
Application of a Portable XRF Spectrometer for <i>In-Situ</i>and Nondestructive Investigation of Pigments in Two 15th Century Icons 被引量:1
14
作者 Eglantina Merkaj Nikolla Civici 《Open Journal of Applied Sciences》 2020年第6期305-317,共13页
<span style="font-family:Verdana;">A simple </span><span style="font-family:Verdana;">portable X-Ray Fluorescence (</span><span style="font-family:;" "=&qu... <span style="font-family:Verdana;">A simple </span><span style="font-family:Verdana;">portable X-Ray Fluorescence (</span><span style="font-family:;" "=""><span style="font-family:Verdana;">XRF) spectrometer was successfully used for </span><i><span style="font-family:Verdana;">in-situ</span></i><span style="font-family:Verdana;"> and nondestructive identification of the painting materials in two 15</span><sup><span style="font-family:Verdana;">th</span></sup><span style="font-family:Verdana;"> century icons from the Onufri Museum in Beart, Albania. </span></span><span style="font-family:Verdana;">The spectrometer is based on a low power X-ray tube, a thermoelectrically cooled Si PIN detector and the spectrum acquisition system. It was assembled and adjusted at our laboratory for the investigation of the icons. </span><span style="font-family:Verdana;">A small number of pigments were clearly identified by </span><span style="font-family:Verdana;">X-Ray Fluorescence (</span><span style="font-family:Verdana;">XRF) measurements in both icons. This include</span><span style="font-family:Verdana;">s</span><span style="font-family:;" "=""><span style="font-family:Verdana;"> Lead white for the white color, gold and yellow ochre for the yellow color, red lead, cinnabar and red ochre for the red color, as well as cooper based pigments for the green color. At the same time, the investigation raised some new questions that need further investigations by </span><span style="font-family:Verdana;">the use of additional analytical techniques. The results show that in both</span><span style="font-family:Verdana;"> icons are used similar pigments, which are in accordance with the Byzantine icon painting tradition.</span></span> 展开更多
关键词 portable X-Ray Fluorescence (XRF) Spectrometer Pigment Analysis Icons Albanian Icons Berat Albania
下载PDF
RESEARCH OF A NEW PORTABLE GC INSTRUMENTATION AND ITS APPLICATION IN BIOMEDICAL ENGINEERING 被引量:3
15
作者 Li Fucheng Li Zhiyi Pan Qi (College of Precision Instrumentation and photoelectron Engineering Tianjin University, Tianjin, 300072, China) 《Chinese Journal of Biomedical Engineering(English Edition)》 1997年第4期243-248,共6页
-A Portable gas chromatograPhy (GC) instrument is presented in this paper. In this GC instrument a new gaseous sampling device was used in place of conventional sampling valves.It has no quantitative tube or movable c... -A Portable gas chromatograPhy (GC) instrument is presented in this paper. In this GC instrument a new gaseous sampling device was used in place of conventional sampling valves.It has no quantitative tube or movable components in the sample Path. The sampling size si determined by time with a high precision,which is not sensitive to the sample temperature and pressure.Especially,the sample can not only inject into the column head,but also the carrier gas blow the column reversely and clean it.The portable GC instrument based on the sampling device can be used in enviromental and biomedical monitoring. 展开更多
关键词 GAS Chromatograpky Sampling DEVICE portable instrument.
下载PDF
Condition Assessment of August A. Busch Bridge Deck Using Portable Seismic Property Analyzer and Ground Penetrating Radar 被引量:1
16
作者 Samie Hamad Wajdi Ammar +1 位作者 Salah Shaniba Abdelmajeed Altlomate 《Open Journal of Civil Engineering》 2022年第1期14-21,共8页
Ground penetrating radar (GPR) and the portable seismic property analyzer (PSPA) have been extensively used in the past two decades for monitoring, quantifying, and mapping the deterioration of bridge decks. Using PSP... Ground penetrating radar (GPR) and the portable seismic property analyzer (PSPA) have been extensively used in the past two decades for monitoring, quantifying, and mapping the deterioration of bridge decks. Using PSPA and GPR ensures regular monitoring of bridge conditions, leads to the early detection of deterioration. This research is to address the condition of August A. Busch bridge deck owned by the Missouri Department of Conservation. Visual inspection, GPR, and PSPA data were acquired on the bridge deck. Over 90% of the bridge deck was in fair to good condition with an average compressive strength of over 2500 psi. GPR data showed no indication of significant deterioration. The overall bridge deck was determined to be in fair to good condition. 展开更多
关键词 Ground Penetrating Radar portable Seismic Property Analyzer Bridge Deck Concrete Deterioration
下载PDF
Portable mixed abrasive water jet equipment for rescue in high gas mine shaft 被引量:7
17
作者 ZENG Rui DU Chang-long +1 位作者 XU Rui ZHAO Jing 《Journal of Coal Science & Engineering(China)》 2011年第2期207-211,共5页
关键词 高瓦斯矿井 水射流设备 混合磨料 应急救援 便携式 切削深度 磨料水射流 切割设备
下载PDF
Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
18
作者 Xiaohao Wang Ran Liu +2 位作者 Fei Tang Yangchun Yu Zhaoying Zhou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (... In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. 展开更多
关键词 data processing portable blood sugar analyzer dynamic linear detecting method
下载PDF
PHOTOTHERAPY FOR MILD TO MODERATE ACNE VULGARIS WITH PORTABLE BLUE AND RED LED
19
作者 GUANGDA LIU CHANGE PAN +2 位作者 KAI LI YUAN TAN XUNBIN WEI 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第1期45-52,共8页
In this paper,we studied portable blue and red light-emitting-diode(LED)light sources in phototherapy for mild to moderate acne vulgaris to evaluate the efficacy and tolerance of patients.Patients,randomly divided int... In this paper,we studied portable blue and red light-emitting-diode(LED)light sources in phototherapy for mild to moderate acne vulgaris to evaluate the efficacy and tolerance of patients.Patients,randomly divided into blue and red groups,received either blue or red LED phototherapy twice a week for four weeks.After complete treatment,the number of lesions reduced by 71.4% in the blue group,in contrast to 19.5% in the red group.No obvious side effects were observed during and one month after the treatment,except for some mild dryness mentioned by several patients. 展开更多
关键词 Acne vulgaris light emitting diode PHOTOTHERAPY portable light sources
下载PDF
Design and verification of portable direct shear tester with application to remolded colluvium geomaterials
20
作者 K.J.Shou Y.W.Lin 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE 2012年第4期326-332,共7页
The mechanical properties of colluvium strongly govern the stability of colluvial slopes, and they arc essential for the related analysis and design. Nevertheless, their measurement is not easy on account of heterogen... The mechanical properties of colluvium strongly govern the stability of colluvial slopes, and they arc essential for the related analysis and design. Nevertheless, their measurement is not easy on account of heterogeneity in property and difficulty of sampling. This study attempted to evaluate the shear strength of remolded colluvium by means of a simple direct shear test in the field. A portable direct shear tester was designed to overcome the inconvenience and expensiveness of the conventional large-scale in-situ direct shear test. It can be easily assembled and applied for the silnplc field direct shear test. For calibration, the results of the portable direct shear tester were compared with the results of the laboratory direct shear tester for four different types of soil samples, i.e. standard sand, slate debris, arenaceous shale debris and mixture of gravel and sand. Correlation formulas were established based on the calibration, enabling the portable direct shear tester to measure and estimate the shear strength of remoldcd colluvium in field. This study primarily focuses on the colluvium in Central Taiwan, including the lateritic Dadu Terrace and the arcnaceous shale of Taiping-Wufcng mounts. The portable direct shear tester was applied to sites selected in these areas, and the results were furthcr analyzed and discussed. 展开更多
关键词 direct shear test portable direct shear tester simple field direct shear test colluvial slope
下载PDF