Portable Analyzer for Rapid Analysis of Total Protein, Fat and Lactose Contents in Raw Milk Measured by Non-dispersive Short-wave Near-infrared Spectrometry 被引量:6
1
作者 FENG Xu-dong SU Rui XU Nan WANG Xing-hua YU Ai-min ZHANG Han-qi CAO Yan-bo 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2013年第1期15-19,共5页
A novel portable analyzer for raw milk quality control during the material purchase at dairy plants was developed, by which the percentages(mass fraction) of main components including total protein, fat, and lactose... A novel portable analyzer for raw milk quality control during the material purchase at dairy plants was developed, by which the percentages(mass fraction) of main components including total protein, fat, and lactose of an unhomogenized milk sample could be determinated in 1 min with the help of non-dispersive short-wave near-infrared (NDSWNIR) spectrometry in a wavelength range from 600 nm to 1100 nm and multivariate calibration. The analyzer was designed with a single-beam optical system, which comprised a temperature control module, a multi-channel narrow-band light source(16 wavelengths), a glass absorption cell with 15 mm sample thickness, a silicon photodiode detector, several compound lenses and a recorder module. A total of 80 raw milk samples were collected at a dairy farm twice a month for 4 months. The samples were scanned with a common UV-Vis-NIR spectrometer and analyzed according to China GB standard methods. The uninformative variables elimination(UVE) method was carried out on the spectrum data and the percentages of main components of all the samples to choose the peak emitting wavelength of each channel of the light source. Another 90 raw milk samples were collected from the same dairy farm thrice a month for 3 months. The samples were analyzed according to China GB standard methods and with the proposed analyzer. The percentages of the main components and the NDSWNIR absorption data of the samples were used for the construction and validation of the multivariate calibration model with partial least squares(PLS) method. The root-mean-square errors of prediction(RMSEP) of total protein, fat and lactose were 0.201, 0.172 and 0.247 and the coefficients of correlation(R) were 0.932, 0.981 and 0.933, respectively. 展开更多
关键词 portable analyzer Raw milk Non-dispersive short-wave near-infrared(NDSWNIR) spectrometry Multiva-riate calibration
原文传递
Condition Assessment of August A. Busch Bridge Deck Using Portable Seismic Property Analyzer and Ground Penetrating Radar 被引量:1
2
作者 Samie Hamad Wajdi Ammar +1 位作者 Salah Shaniba Abdelmajeed Altlomate 《Open Journal of Civil Engineering》 2022年第1期14-21,共8页
Ground penetrating radar (GPR) and the portable seismic property analyzer (PSPA) have been extensively used in the past two decades for monitoring, quantifying, and mapping the deterioration of bridge decks. Using PSP... Ground penetrating radar (GPR) and the portable seismic property analyzer (PSPA) have been extensively used in the past two decades for monitoring, quantifying, and mapping the deterioration of bridge decks. Using PSPA and GPR ensures regular monitoring of bridge conditions, leads to the early detection of deterioration. This research is to address the condition of August A. Busch bridge deck owned by the Missouri Department of Conservation. Visual inspection, GPR, and PSPA data were acquired on the bridge deck. Over 90% of the bridge deck was in fair to good condition with an average compressive strength of over 2500 psi. GPR data showed no indication of significant deterioration. The overall bridge deck was determined to be in fair to good condition. 展开更多
关键词 Ground Penetrating Radar portable Seismic Property analyzer Bridge Deck Concrete Deterioration
下载PDF
Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
3
作者 Xiaohao Wang Ran Liu +2 位作者 Fei Tang Yangchun Yu Zhaoying Zhou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (... In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. 展开更多
关键词 data processing portable blood sugar analyzer dynamic linear detecting method