This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to De...This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.展开更多
AIM:To represent mathematically the intersection between the ectatic corneal geometry and the plane of intracorneal ring implants(ICRS)in order to determine the corneal response to ICRS surgery in keratoconus(KC)...AIM:To represent mathematically the intersection between the ectatic corneal geometry and the plane of intracorneal ring implants(ICRS)in order to determine the corneal response to ICRS surgery in keratoconus(KC).Thereafter,to present the concept and early results of a newly derived topography-guided nomogram for ICRS surgery for the treatment of keratectasia. METHODS:The corneal rings plane intersection was modelled to a conic section. Ring effect was the result of:the ring size,position(steep vs flat),location(distance from the geometric centre of the cornea),and the discrepancy between the ring's curvature and the tunnel's curvature.Femtosecond laser was used to create the tunnels and the incision sites were chosen according to the nomogram in order to place the thickest ring in the steepest portion of the cornea regardless of the astigmatism axis of refraction.RESULTS:The conic section had a more prolate shape in the steep area of the cornea than in the flat area,depending on the corneal sagittal curvature. Equal ring size had more flattening effect in the steep area than in the flat area. Thick segment should be implanted under the steep portion of the cornea regardless of the cylinder axis of refraction. Single segment in the steep area was sufficient in early and moderate cases of KC. The new nomogram provided more topographic regularity with significant reduction of astigmatism and better improvement in uncorrected visual acuity(UCVA)and best-corrected visual acuity(BCVA)than the conventional nomogram. CONCLUSION:The newly derived nomogram can produce better results than the conventional nomogram. Moreover,based on this concept,a new nomogram can be integrated into the femtosecond laser software to create topography-guided,customized,elliptical tunnels with modified focal asphericity that allows for customized focal flattening of the irregularly steepened ectatic cornea.展开更多
文摘This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.
文摘AIM:To represent mathematically the intersection between the ectatic corneal geometry and the plane of intracorneal ring implants(ICRS)in order to determine the corneal response to ICRS surgery in keratoconus(KC).Thereafter,to present the concept and early results of a newly derived topography-guided nomogram for ICRS surgery for the treatment of keratectasia. METHODS:The corneal rings plane intersection was modelled to a conic section. Ring effect was the result of:the ring size,position(steep vs flat),location(distance from the geometric centre of the cornea),and the discrepancy between the ring's curvature and the tunnel's curvature.Femtosecond laser was used to create the tunnels and the incision sites were chosen according to the nomogram in order to place the thickest ring in the steepest portion of the cornea regardless of the astigmatism axis of refraction.RESULTS:The conic section had a more prolate shape in the steep area of the cornea than in the flat area,depending on the corneal sagittal curvature. Equal ring size had more flattening effect in the steep area than in the flat area. Thick segment should be implanted under the steep portion of the cornea regardless of the cylinder axis of refraction. Single segment in the steep area was sufficient in early and moderate cases of KC. The new nomogram provided more topographic regularity with significant reduction of astigmatism and better improvement in uncorrected visual acuity(UCVA)and best-corrected visual acuity(BCVA)than the conventional nomogram. CONCLUSION:The newly derived nomogram can produce better results than the conventional nomogram. Moreover,based on this concept,a new nomogram can be integrated into the femtosecond laser software to create topography-guided,customized,elliptical tunnels with modified focal asphericity that allows for customized focal flattening of the irregularly steepened ectatic cornea.