The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tension...The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability.展开更多
The effect of deficiency in tunnel crown thickness on the Yellow River Crossing Tunnel with post-tensioned concrete inner lining was investigated by the elasto-plastic finite element method. Changes in the deformation...The effect of deficiency in tunnel crown thickness on the Yellow River Crossing Tunnel with post-tensioned concrete inner lining was investigated by the elasto-plastic finite element method. Changes in the deformations and circumferential stresses of the post-tensioned concrete inner lining with the gradual decrease of the tunnel crown thickness were compared, and the potential bearing risk of insufficient tunnel crown thickness for the Yellow River Crossing Tunnel was revealed. Based on the finite element calculation results of circumferential stresses under different defective cases, the corresponding reinforcement schemes were proposed. The calculation results show that the inner lining can still maintain a satisfactory stress state when the tunnel crown thickness is equal to or greater than 0. 28 m. When the tunnel crown thickness decreases below 0.28 m, the external surface of the crown and internal surface of the crown's adjacent areas may be under tension. The tension stresses will incrementally increase and ultimately exceed the tensile strength of the inner lining concrete as the tunnel crown thickness further decreases gradually. Then, the Yellow River Crossing Tunnel cannot operate normally, and severe cracking, leaking or even failure may occur. When the tunnel crown thickness is equal to or greater than 0.28 m, the reinforcement suggestions are that the void spaces between the inner lining and the outer lining should be back-filled with concrete. When the tunnel crown thickness is less than 0. 28 m, the inner lining should be reinforced by steel plates after concrete back-filling.展开更多
A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivatio...A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivation of the formulations. A tri-linear bond-slip constitutive law is used for modeling the tendon-grout interface behavior and debonding of this interface. The bearing plate width is also considered in the analysis. The obtained solutions are in the integral forms and numerical techniques that have been used for evaluation. In the illustrative example given, the major principal stress is compressive in the anchor free zone and compressive stress concentrations of 815 k Pa and 727 k Pa(for the anchor load of 300 k N) are observed under the bearing plate and the bond length proximal end, respectively. However, large values of tensile stresses with the maximum of-434 k Pa are formed at the bond length distal end. The results obtained using the proposed solution are compared very those of numerical method(FEM).展开更多
High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and...High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and safety standards. Despite the advances that have been made in rock mechanics and rock engineering during the last 80 years in which post-tensioned anchors have been used in dam en- gineering, some aspects of the rock engineering design of high-capacity rock anchors for dams have changed relatively little over the last 30 or 40 years. This applies, in particular, to the calculations usually carried out to establish the grouted embedment lengths required for deep, post-tensioned anchors. These calculations usually make simplified assumptions about the distribution and values of rock-grout interface shear strengths, the shape of the volume of rock likely to be involved in uplift failure under the influence of a system of post-tensioned anchors, and the mechanism of that failure. The resulting designs are generally conservative. It is concluded that these aspects of the rock engineering design of large, post- tensioned rock anchors for dams can be significantly improved by making greater use of modern, comprehensive, numerical analyses in conjunction with three-dimensional (3D) models of the rock mass structure, realistic rock and rock mass properties, and the results of prototype anchor tests in the rock mass concerned.展开更多
A multiple rocking wall-frame(MRWF)system,in which the wall panels are directly connected to the adjacent beams and foundation is presented herein.In the MRWF system,the unbonded post-tensioned(PT)tendons are used to ...A multiple rocking wall-frame(MRWF)system,in which the wall panels are directly connected to the adjacent beams and foundation is presented herein.In the MRWF system,the unbonded post-tensioned(PT)tendons are used to promote the self-centering ability,and O-shaped steel dampers are applied to enhance the energy dissipation capacity and reparability of the structure.First,analytical equations are proposed to determine the behavior of the O-shaped dampers.Then,the MRWF system is numerically evaluated for five different models consisting of rocking walls with varying numbers and arrangements while keeping the total effective width of wall panels constant.The numerical results show that with an increase in the number of wall panels and a decrease in the wall width,the hysteretic behavior of the MRWF system tends to the ideal flag-shaped pattern,resulting in little damage to the beams,insignificant strain in the wall toe,negligible residual drifts and damage index of less than 0.2 under severe earthquakes.In contrast,the conventional model demonstrates extensive damage to the structural elements due to undesirable wall-to-frame interaction,which leads to a damage index of 0.78 and residual drifts of 0.42%under seismic loads.展开更多
After grouting the ducts in a large band beam and one-way slab post-tensioned floor system in a large shopping mall (in excess of 1.5 km2 in plan), doubts arose concerning the level of initial prestress and the stre...After grouting the ducts in a large band beam and one-way slab post-tensioned floor system in a large shopping mall (in excess of 1.5 km2 in plan), doubts arose concerning the level of initial prestress and the strength and serviceability of the slabs was questioned. To assess the strength of the slabs, it was assumed, as a worst case scenario, that some spans may have been constructed with zero initial prestress. Load tests on prototype specimens, with similar dimensions and reinforcement quantities as the floor slabs, were performed to assess the stress development in initially unstressed, but fully grouted, tendons. Unexpected bond failures occurred at the junctions of slab and band beam where the abrupt change in section depth caused a sudden change in tendon stress. The maximum stress that was developed in the initially unstressed tendons at these locations was about 60% of the strength of the tendons.展开更多
A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel...A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.展开更多
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ...The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.展开更多
The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analyt...The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analytical model of the overall structure was developed in OpenSees.The multi-spring contact element was adopted to simulate gap open-close behavior at connection interfaces.The limit states of external mild steel dampers and unbonded post-tensioning strands were considered.Static pushover analyses were performed up to the roof drift of 10%.The nonlinear dynamic responses under four groups of ground motions(with different fault distances and site conditions)at six hazard levels(from the service to the very rare earthquake(VRE))were compared.Incremental dynamic analyses were implemented to quantify the structural collapse risk.The results showed that the structural responses of SC-RCF were satisfactory under all levels of earthquakes.The collapse safety of the structure under earthquakes up to VRE1 was adequate,while the structure would collapse to a large extent under VRE2 and VRE3.展开更多
Fiber Reinforced Polymer (FRP) composites are an effective material for strengthening circular concrete columns. The effectiveness of FRP confinement for square and rectangular columns is greatly reduced due to stre...Fiber Reinforced Polymer (FRP) composites are an effective material for strengthening circular concrete columns. The effectiveness of FRP confinement for square and rectangular columns is greatly reduced due to stress concentrations at the sharp comers and loss of the membrane effect at the fiat sides of the cross-section. Shape modification can eliminate the effects of column comers and flat sides, and thereby restore the membrane effect and improve the compressive behavior of FRP-confined square and rectangular concrete columns. Shape modification using chemical post-tensioning, achieved by using expansive cement concrete, is described and several mix designs for obtaining the optimal level of expansion are presented. In addition, parametric studies regarding the optimal geometry of the shape-modified cross-section are presented utilizing the analytical model.展开更多
Post-tensioned(PT)self-centering moment frames have been developed as an alternative to typical moment-resisting frames(MRFs)for earthquake resistance.When a PT frame deforms laterally,gaps between the beams and colum...Post-tensioned(PT)self-centering moment frames have been developed as an alternative to typical moment-resisting frames(MRFs)for earthquake resistance.When a PT frame deforms laterally,gaps between the beams and columns open.However,the gaps are constrained by the columns and the slab in a real PT selfcentering building frame.This paper presents a methodology for evaluating the column restraint and beam compression force based on the column deformation and gap openings at all stories.The method is verified by cyclic tests of a full-scale,two-bay by one-story PT frame.Moreover,a sliding slab is proposed to minimize restraints on the expansion of the PT frame.Shaking table tests were conducted on a reduced-scale,two-by-two bay one-story specimen,which comprises one PT frame and two gravitational frames.The PT frame and gravitational frames are self-centering throughout the tests,responding in phase with only minor differences in peak drifts caused by expansion of the PT frame.When the specimen is excited by a simulation of the 1999 Chi-Chi earthquake with a peak ground acceleration of 1.87 g,the maximum interstory drift and the residual drift are 7.2%and 0.01%,respectively.展开更多
The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC)...The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC) connections undergone cyclic loading up to 4% lateral drift have been investigated by finite element (FE) analysis using ABAQUS. The PTSC connection is comprised o f bolted top and bottom angles as energy dissipaters and steel strands to provide self-centering capacity. The FE analysis has also been validated against the experimental test. The new formulations derived from analytical method has been proposed to predict bending moment o f PTSC connections. The web-post buckling in hexagonal castellated beams has been identified as the dominant failure mode when excessive initial post-tensioning force is applied to reach greater bending moment resistance, so it is required to limit the highest initial post-tensioning force to prevent this failure. Furthermore, properties o f steel material has been simulated using bilinear elastoplastic modeling with 1.5% strain-hardening which has perfectly matched with the real material of steel angles. It is recommended to avoid using steel angles with high yielding strength since they lead to the yielding o f bolt shank. The necessity o f reinforcing plates to prevent beam flange from local buckling has been reaffirmed.展开更多
High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and...High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and safety standards. Despite the advances that have been made in rock mechanics and rock engineering during the last 80 years in which post-tensioned anchors have been used in dam engineering, some aspects of the rock engineering design of high-capacity rock anchors for dams have changed relatively little over the last 30 or 40 years. This applies, in particular, to the calculations usually carried out to establish the grouted embedment lengths required for deep, post-tensioned anchors.These calculations usually make simpli fi ed assumptions about the distribution and values of rock e grout interface shear strengths, the shape of the volume of rock likely to be involved in uplift failure under the in fl uence of a system of post-tensioned anchors, and the mechanism of that failure. The resulting designs are generally conservative. It is concluded that these aspects of the rock engineering design of large, posttensioned rock anchors for dams can be significantly improved by making greater use of modern,comprehensive, numerical analyses in conjunction with three-dimensional(3D) models of the rock mass structure, realistic rock and rock mass properties, and the results of prototype anchor tests in the rock mass concerned.展开更多
An experimental study is performed on five post-tensioned concrete beams to explore the effects of different fracture positions on secondary transfer length and residual prestress of fractured strand.A numerical model...An experimental study is performed on five post-tensioned concrete beams to explore the effects of different fracture positions on secondary transfer length and residual prestress of fractured strand.A numerical model is developed and used to predict the secondary transfer length and residual prestress of fractured strand in post-tensioned concrete beams.The model change interaction,which can deactivate and reactivate the elements for simulating the removal and reproduction of parts of the model,is used to reproduce the secondary anchorage of fractured strand.The numerical model is verified by experimental results.Results shows that the fractured strand can be reanchored in concrete through the secondary anchorage,and the secondary transfer length of fractured strand with the diameter of 15.2 mm is 1133 mm.The residual prestress of fractured strand increases gradually in the secondary transfer length,and tends to be a constant beyond it.When the fractured strand is fully anchored in concrete,a minor prestress loss will appear,and the average prestress loss is 2.28%in the present study.展开更多
Post-tensioned concrete rocking walls might be used to avoid severe seismic damage at the base of structural walls, decrease residual drift, and lessen post-earthquake repair costs. The prediction of load-induced dama...Post-tensioned concrete rocking walls might be used to avoid severe seismic damage at the base of structural walls, decrease residual drift, and lessen post-earthquake repair costs. The prediction of load-induced damage to the rocking wall resulting from seismic loading can provide an extremely valuable tool to evaluate the status and safety of structural concrete walls following earthquakes. In this study, the behavior and the damage state of monolithic, self-centering, rocking walls, as a new type of concrete rocking wall, are investigated. The nonlinear mechanical behavior of the wall is first modeled numerically, and subsequently the mechanical parameters from the numerical simulation are used to generate the local damage index. The results from the damage index model are compared with the full-scale test results, confirming the viability of the numerically based damage index method for estimating the seismically induced damage in concrete walls. Moreover, the estimated damage can be utilized as a qualitative and quantitative scale to assess the status of the wall following seismic loading events.Finally, an equation is proposed to estimate the repair cost based on the predicted damage state for the studied structural system.展开更多
Currently, traditional analysis and design methods are unreasonable in evaluating the performance and safety of pavements. The characteristic of shakedown theory lends itself particularly to the analysis of pavements....Currently, traditional analysis and design methods are unreasonable in evaluating the performance and safety of pavements. The characteristic of shakedown theory lends itself particularly to the analysis of pavements. Based on the lower bound shakedown theory, a simple and practical procedure for shakedown analysis of pavements has been developed using plastic strain energy as shakedown criteria via considering a special loading path. The proposed method is verified by using a homogeneous isotropic half space. Then, the method is applied to analyze a two-layered pavement. The dependence of shakedown limit on material properties of pavements is investigated in details. According to the analysis results, some valuable references are suggested for the selection of materials for accurate evaluation of the bearing performance of pavement under traffic loading.展开更多
This paper presents an application of strut-and-tie model(STM) to design the interior anchorage zone(IAZ) in the post-tensioned concrete structure.The STM theory and range of IAZ are introduced.Then,based on the finit...This paper presents an application of strut-and-tie model(STM) to design the interior anchorage zone(IAZ) in the post-tensioned concrete structure.The STM theory and range of IAZ are introduced.Then,based on the finite element analysis,a series of simplified equations to calculate internal forces in IAZ are presented.Finally,the STM model for IAZ is given.In the proposed STM model,internal forces in ties vary with the dimension ratio and the eccentricity of load.The U-turn of internal forces is suggested to allocate rebar to resist bearing flexural tensile force.Compared with the FIP(International Federation for Prestressing) model,the proposed STM model is more reasonable and applicable.展开更多
Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story se...Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story selfcentering wall building has now been designed and constructed using the state-of-art design methodologies and construction detailing,as described in this paper.The building is designed in accordance with direct displacement-based design methodology,with modification of seismic demand due to relevant issues including higher-mode effects,second order effects,torsional effects,and flexural deformation of wall panels.Wall sections are designed with external energydissipating devices of steel dampers,and seismic performance of such designed self-centering walls is evaluated through numerical simulation.It is the first engineering project that uses self-centering walls in a high-rise building.The seismic design procedure of such a high-rise building,using self-centering wall structures,is comprehensively reviewed in this work,and additional proposals are put forward.Description of construction detailing,including slotted beams,flexible wall-to-floor connections,embedded beams,and damper installation,is provided.The demonstration project promotes the concept of seismic resilient structures and contributes to the most appealing city planning strategy of resilient cities at present.The paper could be a reference for industry engineers to promote the self-centering wall systems worldwide.展开更多
As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Ea...As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems.展开更多
文摘The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability.
基金The Natural Science Foundation of Hubei Province(No.2017CFB667)the National Natural Science Foundation of China(No.51079107)
文摘The effect of deficiency in tunnel crown thickness on the Yellow River Crossing Tunnel with post-tensioned concrete inner lining was investigated by the elasto-plastic finite element method. Changes in the deformations and circumferential stresses of the post-tensioned concrete inner lining with the gradual decrease of the tunnel crown thickness were compared, and the potential bearing risk of insufficient tunnel crown thickness for the Yellow River Crossing Tunnel was revealed. Based on the finite element calculation results of circumferential stresses under different defective cases, the corresponding reinforcement schemes were proposed. The calculation results show that the inner lining can still maintain a satisfactory stress state when the tunnel crown thickness is equal to or greater than 0. 28 m. When the tunnel crown thickness decreases below 0.28 m, the external surface of the crown and internal surface of the crown's adjacent areas may be under tension. The tension stresses will incrementally increase and ultimately exceed the tensile strength of the inner lining concrete as the tunnel crown thickness further decreases gradually. Then, the Yellow River Crossing Tunnel cannot operate normally, and severe cracking, leaking or even failure may occur. When the tunnel crown thickness is equal to or greater than 0.28 m, the reinforcement suggestions are that the void spaces between the inner lining and the outer lining should be back-filled with concrete. When the tunnel crown thickness is less than 0. 28 m, the inner lining should be reinforced by steel plates after concrete back-filling.
文摘A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivation of the formulations. A tri-linear bond-slip constitutive law is used for modeling the tendon-grout interface behavior and debonding of this interface. The bearing plate width is also considered in the analysis. The obtained solutions are in the integral forms and numerical techniques that have been used for evaluation. In the illustrative example given, the major principal stress is compressive in the anchor free zone and compressive stress concentrations of 815 k Pa and 727 k Pa(for the anchor load of 300 k N) are observed under the bearing plate and the bond length proximal end, respectively. However, large values of tensile stresses with the maximum of-434 k Pa are formed at the bond length distal end. The results obtained using the proposed solution are compared very those of numerical method(FEM).
文摘High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and safety standards. Despite the advances that have been made in rock mechanics and rock engineering during the last 80 years in which post-tensioned anchors have been used in dam en- gineering, some aspects of the rock engineering design of high-capacity rock anchors for dams have changed relatively little over the last 30 or 40 years. This applies, in particular, to the calculations usually carried out to establish the grouted embedment lengths required for deep, post-tensioned anchors. These calculations usually make simplified assumptions about the distribution and values of rock-grout interface shear strengths, the shape of the volume of rock likely to be involved in uplift failure under the influence of a system of post-tensioned anchors, and the mechanism of that failure. The resulting designs are generally conservative. It is concluded that these aspects of the rock engineering design of large, post- tensioned rock anchors for dams can be significantly improved by making greater use of modern, comprehensive, numerical analyses in conjunction with three-dimensional (3D) models of the rock mass structure, realistic rock and rock mass properties, and the results of prototype anchor tests in the rock mass concerned.
文摘A multiple rocking wall-frame(MRWF)system,in which the wall panels are directly connected to the adjacent beams and foundation is presented herein.In the MRWF system,the unbonded post-tensioned(PT)tendons are used to promote the self-centering ability,and O-shaped steel dampers are applied to enhance the energy dissipation capacity and reparability of the structure.First,analytical equations are proposed to determine the behavior of the O-shaped dampers.Then,the MRWF system is numerically evaluated for five different models consisting of rocking walls with varying numbers and arrangements while keeping the total effective width of wall panels constant.The numerical results show that with an increase in the number of wall panels and a decrease in the wall width,the hysteretic behavior of the MRWF system tends to the ideal flag-shaped pattern,resulting in little damage to the beams,insignificant strain in the wall toe,negligible residual drifts and damage index of less than 0.2 under severe earthquakes.In contrast,the conventional model demonstrates extensive damage to the structural elements due to undesirable wall-to-frame interaction,which leads to a damage index of 0.78 and residual drifts of 0.42%under seismic loads.
文摘After grouting the ducts in a large band beam and one-way slab post-tensioned floor system in a large shopping mall (in excess of 1.5 km2 in plan), doubts arose concerning the level of initial prestress and the strength and serviceability of the slabs was questioned. To assess the strength of the slabs, it was assumed, as a worst case scenario, that some spans may have been constructed with zero initial prestress. Load tests on prototype specimens, with similar dimensions and reinforcement quantities as the floor slabs, were performed to assess the stress development in initially unstressed, but fully grouted, tendons. Unexpected bond failures occurred at the junctions of slab and band beam where the abrupt change in section depth caused a sudden change in tendon stress. The maximum stress that was developed in the initially unstressed tendons at these locations was about 60% of the strength of the tendons.
基金National Natural Science Foundation of China under Nos.50808107,51178250 and 51261120377
文摘A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.
基金National Natural Science Foundation of China(NSFC)under Grant Nos.51638012 and 51578401
文摘The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.
基金Key Project of the Key Laboratory of Earthquake Engineering and Engineering Vibration,China Earthquake Administration under Grant No.2019EEEVL0304National Natural Science Foundation of China(NSFC)under Grant No.51678543。
文摘The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analytical model of the overall structure was developed in OpenSees.The multi-spring contact element was adopted to simulate gap open-close behavior at connection interfaces.The limit states of external mild steel dampers and unbonded post-tensioning strands were considered.Static pushover analyses were performed up to the roof drift of 10%.The nonlinear dynamic responses under four groups of ground motions(with different fault distances and site conditions)at six hazard levels(from the service to the very rare earthquake(VRE))were compared.Incremental dynamic analyses were implemented to quantify the structural collapse risk.The results showed that the structural responses of SC-RCF were satisfactory under all levels of earthquakes.The collapse safety of the structure under earthquakes up to VRE1 was adequate,while the structure would collapse to a large extent under VRE2 and VRE3.
文摘Fiber Reinforced Polymer (FRP) composites are an effective material for strengthening circular concrete columns. The effectiveness of FRP confinement for square and rectangular columns is greatly reduced due to stress concentrations at the sharp comers and loss of the membrane effect at the fiat sides of the cross-section. Shape modification can eliminate the effects of column comers and flat sides, and thereby restore the membrane effect and improve the compressive behavior of FRP-confined square and rectangular concrete columns. Shape modification using chemical post-tensioning, achieved by using expansive cement concrete, is described and several mix designs for obtaining the optimal level of expansion are presented. In addition, parametric studies regarding the optimal geometry of the shape-modified cross-section are presented utilizing the analytical model.
基金The test programs were supported by the Science Council and Center for Research on Earthquake Engineering(NCREE),Taiwan.
文摘Post-tensioned(PT)self-centering moment frames have been developed as an alternative to typical moment-resisting frames(MRFs)for earthquake resistance.When a PT frame deforms laterally,gaps between the beams and columns open.However,the gaps are constrained by the columns and the slab in a real PT selfcentering building frame.This paper presents a methodology for evaluating the column restraint and beam compression force based on the column deformation and gap openings at all stories.The method is verified by cyclic tests of a full-scale,two-bay by one-story PT frame.Moreover,a sliding slab is proposed to minimize restraints on the expansion of the PT frame.Shaking table tests were conducted on a reduced-scale,two-by-two bay one-story specimen,which comprises one PT frame and two gravitational frames.The PT frame and gravitational frames are self-centering throughout the tests,responding in phase with only minor differences in peak drifts caused by expansion of the PT frame.When the specimen is excited by a simulation of the 1999 Chi-Chi earthquake with a peak ground acceleration of 1.87 g,the maximum interstory drift and the residual drift are 7.2%and 0.01%,respectively.
文摘The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC) connections undergone cyclic loading up to 4% lateral drift have been investigated by finite element (FE) analysis using ABAQUS. The PTSC connection is comprised o f bolted top and bottom angles as energy dissipaters and steel strands to provide self-centering capacity. The FE analysis has also been validated against the experimental test. The new formulations derived from analytical method has been proposed to predict bending moment o f PTSC connections. The web-post buckling in hexagonal castellated beams has been identified as the dominant failure mode when excessive initial post-tensioning force is applied to reach greater bending moment resistance, so it is required to limit the highest initial post-tensioning force to prevent this failure. Furthermore, properties o f steel material has been simulated using bilinear elastoplastic modeling with 1.5% strain-hardening which has perfectly matched with the real material of steel angles. It is recommended to avoid using steel angles with high yielding strength since they lead to the yielding o f bolt shank. The necessity o f reinforcing plates to prevent beam flange from local buckling has been reaffirmed.
文摘High-capacity, post-tensioned anchors have found wide-spread use, originally in initial dam design and construction, and more recently in the strengthening and rehabilitation of concrete dams to meet modern design and safety standards. Despite the advances that have been made in rock mechanics and rock engineering during the last 80 years in which post-tensioned anchors have been used in dam engineering, some aspects of the rock engineering design of high-capacity rock anchors for dams have changed relatively little over the last 30 or 40 years. This applies, in particular, to the calculations usually carried out to establish the grouted embedment lengths required for deep, post-tensioned anchors.These calculations usually make simpli fi ed assumptions about the distribution and values of rock e grout interface shear strengths, the shape of the volume of rock likely to be involved in uplift failure under the in fl uence of a system of post-tensioned anchors, and the mechanism of that failure. The resulting designs are generally conservative. It is concluded that these aspects of the rock engineering design of large, posttensioned rock anchors for dams can be significantly improved by making greater use of modern,comprehensive, numerical analyses in conjunction with three-dimensional(3D) models of the rock mass structure, realistic rock and rock mass properties, and the results of prototype anchor tests in the rock mass concerned.
基金the National Natural Science Foundation of China(Grant No.52008035)the Science Fund for Creative Research Groups of Hunan Province(No.2020JJ1006)+3 种基金the Science and Technology Innovation Program of Hunan Province(No.2020RC4024)the Special Funds for the Construction of Innovative Provinces in Hunan Province(No.2019SK2171)the Natural Science Foundation of Hunan Province(No.2021JJ40574)National-Local Joint Laboratory of Engineering Technology for Long-term Performance enhancement of Bridges in Southern District(Changsha University of Science&Technology)(No.19KB03).
文摘An experimental study is performed on five post-tensioned concrete beams to explore the effects of different fracture positions on secondary transfer length and residual prestress of fractured strand.A numerical model is developed and used to predict the secondary transfer length and residual prestress of fractured strand in post-tensioned concrete beams.The model change interaction,which can deactivate and reactivate the elements for simulating the removal and reproduction of parts of the model,is used to reproduce the secondary anchorage of fractured strand.The numerical model is verified by experimental results.Results shows that the fractured strand can be reanchored in concrete through the secondary anchorage,and the secondary transfer length of fractured strand with the diameter of 15.2 mm is 1133 mm.The residual prestress of fractured strand increases gradually in the secondary transfer length,and tends to be a constant beyond it.When the fractured strand is fully anchored in concrete,a minor prestress loss will appear,and the average prestress loss is 2.28%in the present study.
文摘Post-tensioned concrete rocking walls might be used to avoid severe seismic damage at the base of structural walls, decrease residual drift, and lessen post-earthquake repair costs. The prediction of load-induced damage to the rocking wall resulting from seismic loading can provide an extremely valuable tool to evaluate the status and safety of structural concrete walls following earthquakes. In this study, the behavior and the damage state of monolithic, self-centering, rocking walls, as a new type of concrete rocking wall, are investigated. The nonlinear mechanical behavior of the wall is first modeled numerically, and subsequently the mechanical parameters from the numerical simulation are used to generate the local damage index. The results from the damage index model are compared with the full-scale test results, confirming the viability of the numerically based damage index method for estimating the seismically induced damage in concrete walls. Moreover, the estimated damage can be utilized as a qualitative and quantitative scale to assess the status of the wall following seismic loading events.Finally, an equation is proposed to estimate the repair cost based on the predicted damage state for the studied structural system.
基金the National High Technology Research and Development Program (863) of China(No. 2006AA09A103)the Shanghai Leading Academic Discipline Project (No. B208)
文摘Currently, traditional analysis and design methods are unreasonable in evaluating the performance and safety of pavements. The characteristic of shakedown theory lends itself particularly to the analysis of pavements. Based on the lower bound shakedown theory, a simple and practical procedure for shakedown analysis of pavements has been developed using plastic strain energy as shakedown criteria via considering a special loading path. The proposed method is verified by using a homogeneous isotropic half space. Then, the method is applied to analyze a two-layered pavement. The dependence of shakedown limit on material properties of pavements is investigated in details. According to the analysis results, some valuable references are suggested for the selection of materials for accurate evaluation of the bearing performance of pavement under traffic loading.
基金Foundation item: the National High Technology Research and Development Program (863) of China (No. 2006AA09A103) and the Shanghai Leading Academic Discipline Project (No. B208)
文摘This paper presents an application of strut-and-tie model(STM) to design the interior anchorage zone(IAZ) in the post-tensioned concrete structure.The STM theory and range of IAZ are introduced.Then,based on the finite element analysis,a series of simplified equations to calculate internal forces in IAZ are presented.Finally,the STM model for IAZ is given.In the proposed STM model,internal forces in ties vary with the dimension ratio and the eccentricity of load.The U-turn of internal forces is suggested to allocate rebar to resist bearing flexural tensile force.Compared with the FIP(International Federation for Prestressing) model,the proposed STM model is more reasonable and applicable.
基金the Distinguished Young Scientists Fund of National Natural Science Foundation of China(Grant No.52025083)the technical support of Shanghai CITI-RAISE Construction Group.
文摘Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story selfcentering wall building has now been designed and constructed using the state-of-art design methodologies and construction detailing,as described in this paper.The building is designed in accordance with direct displacement-based design methodology,with modification of seismic demand due to relevant issues including higher-mode effects,second order effects,torsional effects,and flexural deformation of wall panels.Wall sections are designed with external energydissipating devices of steel dampers,and seismic performance of such designed self-centering walls is evaluated through numerical simulation.It is the first engineering project that uses self-centering walls in a high-rise building.The seismic design procedure of such a high-rise building,using self-centering wall structures,is comprehensively reviewed in this work,and additional proposals are put forward.Description of construction detailing,including slotted beams,flexible wall-to-floor connections,embedded beams,and damper installation,is provided.The demonstration project promotes the concept of seismic resilient structures and contributes to the most appealing city planning strategy of resilient cities at present.The paper could be a reference for industry engineers to promote the self-centering wall systems worldwide.
文摘As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems.