A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel...A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.展开更多
The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC)...The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC) connections undergone cyclic loading up to 4% lateral drift have been investigated by finite element (FE) analysis using ABAQUS. The PTSC connection is comprised o f bolted top and bottom angles as energy dissipaters and steel strands to provide self-centering capacity. The FE analysis has also been validated against the experimental test. The new formulations derived from analytical method has been proposed to predict bending moment o f PTSC connections. The web-post buckling in hexagonal castellated beams has been identified as the dominant failure mode when excessive initial post-tensioning force is applied to reach greater bending moment resistance, so it is required to limit the highest initial post-tensioning force to prevent this failure. Furthermore, properties o f steel material has been simulated using bilinear elastoplastic modeling with 1.5% strain-hardening which has perfectly matched with the real material of steel angles. It is recommended to avoid using steel angles with high yielding strength since they lead to the yielding o f bolt shank. The necessity o f reinforcing plates to prevent beam flange from local buckling has been reaffirmed.展开更多
As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Ea...As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems.展开更多
基金National Natural Science Foundation of China under Nos.50808107,51178250 and 51261120377
文摘A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.
文摘The effects o f important parameters (beam reinforcing plates, initial post-tensioning, and material properties o f steel angles) on the behavior o f hexagonal castellated beams in post-tensioned self-centering (PTSC) connections undergone cyclic loading up to 4% lateral drift have been investigated by finite element (FE) analysis using ABAQUS. The PTSC connection is comprised o f bolted top and bottom angles as energy dissipaters and steel strands to provide self-centering capacity. The FE analysis has also been validated against the experimental test. The new formulations derived from analytical method has been proposed to predict bending moment o f PTSC connections. The web-post buckling in hexagonal castellated beams has been identified as the dominant failure mode when excessive initial post-tensioning force is applied to reach greater bending moment resistance, so it is required to limit the highest initial post-tensioning force to prevent this failure. Furthermore, properties o f steel material has been simulated using bilinear elastoplastic modeling with 1.5% strain-hardening which has perfectly matched with the real material of steel angles. It is recommended to avoid using steel angles with high yielding strength since they lead to the yielding o f bolt shank. The necessity o f reinforcing plates to prevent beam flange from local buckling has been reaffirmed.
文摘As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems.