期刊文献+
共找到14,214篇文章
< 1 2 250 >
每页显示 20 50 100
Carbon Emission Factors Prediction of Power Grid by Using Graph Attention Network
1
作者 Xin Shen Jiahao Li +3 位作者 YujunYin Jianlin Tang Weibin Lin Mi Zhou 《Energy Engineering》 EI 2024年第7期1945-1961,共17页
Advanced carbon emission factors of a power grid can provide users with effective carbon reduction advice,which is of immense importance in mobilizing the entire society to reduce carbon emissions.The method of calcul... Advanced carbon emission factors of a power grid can provide users with effective carbon reduction advice,which is of immense importance in mobilizing the entire society to reduce carbon emissions.The method of calculating node carbon emission factors based on the carbon emissions flow theory requires real-time parameters of a power grid.Therefore,it cannot provide carbon factor information beforehand.To address this issue,a prediction model based on the graph attention network is proposed.The model uses a graph structure that is suitable for the topology of the power grid and designs a supervised network using the loads of the grid nodes and the corresponding carbon factor data.The network extracts features and transmits information more suitable for the power system and can flexibly adjust the equivalent topology,thereby increasing the diversity of the structure.Its input and output data are simple,without the power grid parameters.We demonstrated its effect by testing IEEE-39 bus and IEEE-118 bus systems with average error rates of 2.46%and 2.51%. 展开更多
关键词 Predict carbon factors graph attention network prediction algorithm power grid operating parameters
下载PDF
Assessment of Axial Power Peaking Factors in GHARR-1 LEU Core: A Decadal Simulation Analysis
2
作者 Emmanuel Kwame Ahiave Emmanuel Ampomah-Amoako +1 位作者 Rex Gyeabour Abrefah Mathew Asamoah 《World Journal of Nuclear Science and Technology》 CAS 2024年第1期72-85,共14页
This study aims to thoroughly investigate the axial power peaking factors (PPF) within the low-enriched uranium (LEU) core of the Ghana Research Reactor-1 (GHARR-1). This study uses advanced simulation tools, like the... This study aims to thoroughly investigate the axial power peaking factors (PPF) within the low-enriched uranium (LEU) core of the Ghana Research Reactor-1 (GHARR-1). This study uses advanced simulation tools, like the MCNPX code for analysing neutron behavior and the PARET/ANL code for understanding power variations, to get a clearer picture of the reactor’s performance. The analysis covers the initial six years of GHARR-1’s operation and includes projections for its whole 60-year lifespan. We closely observed the patterns of both the highest and average PPFs at 21 axial nodes, with measurements taken every ten years. The findings of this study reveal important patterns in power distribution within the core, which are essential for improving the safety regulations and fuel management techniques of the reactor. We provide a meticulous approach, extensive data, and an analysis of the findings, highlighting the significance of continuous monitoring and analysis for proactive management of nuclear reactors. The findings of this study not only enhance our comprehension of nuclear reactor safety but also carry significant ramifications for sustainable energy progress in Ghana and the wider global context. Nuclear engineering is essential in tackling global concerns, such as the demand for clean and dependable energy sources. Research on optimising nuclear reactors, particularly in terms of safety and efficiency, is crucial for the ongoing advancement and acceptance of nuclear energy. 展开更多
关键词 GHARR-1 power Peaking factor Nuclear Reactor Safety Low Enriched Uranium Core Operational Longevity Thermal Hydraulics
下载PDF
Influencing Factors and Improvement Suggestions for Agricultural Green Development Performance:Empirical Insights from China
3
作者 LI Erling ZHANG Mengzhen +1 位作者 LI Ruolan DENG Qingqing 《Chinese Geographical Science》 SCIE CSCD 2023年第5期917-933,共17页
Agricultural green development is an essential direction for global sustainable agriculture.The academic literature,however,needs to place greater emphasis on studying the factors influencing agricultural green develo... Agricultural green development is an essential direction for global sustainable agriculture.The academic literature,however,needs to place greater emphasis on studying the factors influencing agricultural green development performance and how such performance can be improved.A theoretical framework for agricultural green development performance was constructed in this paper using the Super-SBM model,which considers undesirable outputs,to measure the agricultural green development performance of 330 cities at or above the prefecture level in China(excluding Tibet Autonomous Region,Hong Kong,Macao and Taiwan of China)from 2007 to2018.Furthermore,the influencing mechanism of agricultural green development performance was then analyzed using a spatial econometric model.The results show that:1)from 2007 to 2018,China’s agricultural green development performance experienced three stages of evolution:‘rise,decline and rise’.2)The regions with high performance agricultural green development are mainly distributed in eastern China,northeastern China,and southern Qinghai Province.3)The agricultural economic level,industrialization process,and labor quality play significant roles in promoting local agricultural green development performance,while such performance is obviously inhibited by the openness level and the government’s environmental regulations.Local agricultural green development performance is significant inhibited by the agricultural economic level and accelerated industrialization process in neighboring cities,while significantly promoted by the agricultural industrial structure in neighboring cities.Some suggestions for improving agricultural green development performance are proposed based on these research results,which can provide scientific references for promoting sustainable agriculture. 展开更多
关键词 agricultural green development performance influencing factors improvement suggestions China
下载PDF
Low-frequency oscillation of train-network system considering traction power supply mode
4
作者 Yuchen Liu Xiaoqin Lyu +1 位作者 Mingyuan Chang Qiqi Yang 《Railway Engineering Science》 EI 2024年第2期244-256,共13页
The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified ra... The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified railway unilateral power supply system are not suitable for the LFO analysis in a bilateral power supply system,where the trains are supplied by two traction substations.In this work,based on the single-input and single-output impedance model of China CRH5 trains,the node admittance matrices of the train-network system both in unilateral and bilateral power supply modes are established,including three-phase power grid,traction transformers and traction network.Then the modal analysis is used to study the oscillation modes and propagation characteristics of the unilateral and bilateral power supply systems.Moreover,the influence of the equivalent inductance of the power grid,the length of the transmission line,and the length of the traction network are analyzed on the critical oscillation mode of the bilateral power supply system.Finally,the theoretical analysis results are verified by the time-domain simulation model in MATLAB/Simulink. 展开更多
关键词 Low-frequency oscillation Train-network system Modal analysis Bilateral power supply Participation factor
下载PDF
Economic Improvement of Power Factor Correction: A Case Study
5
作者 Kassem Wahab Mohamad Rahal Roger Achkar 《Journal of Power and Energy Engineering》 2021年第6期1-11,共11页
Power factor (PF) is simply an expression of energy efficiency, which is always expressed in terms of percentage. Technically, PF is a ratio of real power in Kilowatts to the apparent power, which is always expressed ... Power factor (PF) is simply an expression of energy efficiency, which is always expressed in terms of percentage. Technically, PF is a ratio of real power in Kilowatts to the apparent power, which is always expressed in kilovolts amperes. In AC power analysis, power is always expressed in three ways, the real power (<i></span><i><span style="font-family:Verdana;">P</span></i><span style="font-family:Verdana;"></i>), reactive power (<i></span><i><span style="font-family:Verdana;">Q</span></i><span style="font-family:Verdana;"></i>), and the apparent power (<i></span><i><span style="font-family:Verdana;">S</span></i><span style="font-family:Verdana;"></i>). The real power is the work useful power, while the reactive power is the wasted power in the 3-phase AC system, and the apparent power is the vectorial sum of the two powers. The increase of reactive power will reduce the presence of real power, thus making the power to be more expensive. In this paper, we will analyze the importance of improving the power factor by applying a bank of capacitors to a case study in Lebanon. Analysis of the economic improvement in the application of power factor correction is carried out. The result shows a reduction of 12 percent in the total cost. 展开更多
关键词 power factor Reactive power kVAR INDUCTIVE Apparent power Active power
下载PDF
Power Factor Improvement of AC-DC Converter Based on Separately Excited DC Motor Using Passive Filter
6
作者 Shazia Baloch Mukhtiar Ahmed Mahar +1 位作者 Raza Haider Shakeel Ahmed 《Open Journal of Energy Efficiency》 2016年第3期71-77,共8页
In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to powe... In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to power electronic AC-DC converters. These power electronic converters are with prominent low power factor and higher Total Harmonic Distortion (THD). These converters operate only for short time resulting non-sinusoidal waveform. This problem of harmonic distortion can be mitigated by reshaping the non-sinusoidal waveform to pure sine wave. Different wave shaping techniques have been developed by using different filters among which one is tuned passive filter. This paper proposed power factor improvement and harmonic mitigation of AC-DC converters based on separately excited DC motor using tuned passive filter. In this context experimental model is designed and results are analyzed by power quality analyzer. 展开更多
关键词 DC Motors AC-DC Converters power factor Total Harmonic Distortion Passive Filters
下载PDF
Period-doubling bifurcation in two-stage power factor correction converters using the method of incremental harmonic balance and Floquet theory 被引量:4
7
作者 王发强 张浩 马西奎 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期153-162,共10页
In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correcti... In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correction converter typically employs a cascade configuration of a pre-regulator boost power factor correction converter with average current mode control to achieve a near unity power factor and a tightly regulated post-regulator DC-DC Buck converter with voltage feedback control to regulate the output voltage. Based on the assumption that the tightly regulated postregulator DC-DC Buck converter is represented as a constant power sink and some other assumptions, the simplified model of the two-stage power factor correction converter is derived and its approximate periodic solution is calculated by the method of IHB. And then, the stability of the system is investigated by using Floquet theory and the stable boundaries are presented on the selected parameter spaces. Finally, some experimental results are given to confirm the effectiveness of the theoretical analysis. 展开更多
关键词 two-stage power factor correction converter incremental harmonic balance Floquet theory period-doubling bifurcation
下载PDF
Fast-scale border collision bifurcation in SEPIC power factor pre-regulators 被引量:3
8
作者 刘芳 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第7期2394-2404,共11页
In this paper we report a kind of fast-scale instability occurring in the single-ended primary inductance converter (SEPIC) power factor pre-regulator, which is designed to operate in discontinuous conduction mode. ... In this paper we report a kind of fast-scale instability occurring in the single-ended primary inductance converter (SEPIC) power factor pre-regulator, which is designed to operate in discontinuous conduction mode. Main results are given by exact cycle-by-cycle computer simulations as well as theoretical analysis. It is found that the instability phenomenon manifests itself as a fast-scale bifurcation at the switching period, which implies the occurrence of border collision bifurcation, or is related to the transition of the regular operating mode of the SEPIC. According to the theoretical analysis and simulation results, the effects of parameters on system stability, and the locations of the bifurcation points are confirmed. Moreover, the effects of such an instability on power factor and switching stress are also discussed. Finally, the occurrence of the asymmetric bifurcation locations is investigated. The results show that this work provides a convenient means of predicting stability boundaries which can facilitate the selection of the practical parameters. 展开更多
关键词 fast-scale instability border collision bifurcation SEPIC power factor pre-regulator discontinuous current mode
下载PDF
A novel arc welding inverter with unit power factor based on DSP control 被引量:3
9
作者 陈树君 曾华 +2 位作者 杜利 殷树言 陈永刚 《China Welding》 EI CAS 2006年第1期53-56,共4页
A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stag... A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stage inverter bridge of the arc welding inverter. The fore-stage adopts double closed loop proportion and integration (PI) rectifier technique and the back- stage adopts digital pulse width modulation ( PWM) technique. Simulated waves can be obtained in Matlab/Simulink and validated by experiments. Experiments of the prototype showed that the total harmonic distortion (THD) can be controlled within 10% and the power factor is approximate to 1. 展开更多
关键词 arc welding inverter power factor correction (PFC) digital signal processor (DSP) HARMONIC
下载PDF
Unexpected low thermal conductivity and large power factor in Dirac semimetal Cd3As2 被引量:1
10
作者 张成 周通 +8 位作者 梁斯航 曹钧植 袁翔 刘彦闻 沈瑶 王奇思 赵俊 杨中芹 修发贤 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期378-383,共6页
Thermoelectrics has long been considered as a promising way of power generation for the next decades. So far, extensive efforts have been devoted to the search of ideal thermoelectric materials, which require both hig... Thermoelectrics has long been considered as a promising way of power generation for the next decades. So far, extensive efforts have been devoted to the search of ideal thermoelectric materials, which require both high electrical conductivity and low thermal conductivity. Recently, the emerging Dirac semimetal Cd3As2, a three-dimensional analogue of graphene, has been reported to host ultra-high mobility and good electrical conductivity as metals. Here, we report the observation of unexpected low thermal conductivity in Cd3As2, one order of magnitude lower than the conventional metals or semimetals with a similar electrical conductivity, despite the semimetal band structure and high electron mobility. The power factor also reaches a large value of 1.58 mW.m 1 .K-2 at room temperature and remains non-saturated up to 400 K. Corroborating with the first-principles calculations, we find that the thermoelectric performance can be well-modulated by the carrier concentration in a wide range. This work demonstrates the Dirac semimetal Cd3As2 as a potential candidate of thermoelectric materials. 展开更多
关键词 Dirac semimetal thermal conductivity power factor thermoelectric material
下载PDF
Power Transformer No-Load Loss Prediction with FEM Modeling and Building Factor Optimization 被引量:2
11
作者 Ehsan Hajipour Pooya Rezaei +1 位作者 Mehdi Vakilian Mohsen Ghafouri 《Journal of Electromagnetic Analysis and Applications》 2011年第10期430-438,共9页
Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for t... Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for the transformer manufacturer. In this paper an effective and novel method is proposed to determine all components of the iron core losses applying a combination of the empirical and numerical techniques. In this method at the first stage all computable components of the core losses are calculated, using Finite Element Method (FEM) modeling and analysis of the transformer iron core. This method takes into account magnetic sheets anisotropy, joint losses and stacking holes. Next, a Quadratic Programming (QP) optimization technique is employed to estimate the incomputable components of the core losses. This method provides a chance for improvement of the core loss estimation over the time when more measured data become available. The optimization process handles the singular deviations caused by different manufacturing machineries and labor during the transformer manufacturing and overhaul process. Therefore, application of this method enables different companies to obtain different results for the same designs and materials employed, using their historical data. Effectiveness of this method is verified by inspection of 54 full size distribution transformer measurement data. 展开更多
关键词 BUILDING factor CORE LOSSES FINITE ELEMENT Method power Transformer
下载PDF
Stimulated Brillouin Scattering Enhancement Factor Improvement in a 11.6-GHz-Linewidth 1.5-kW Yb-Doped Fiber Amplifier 被引量:2
12
作者 刘广柏 杨依枫 +7 位作者 王建华 郑也 陈晓龙 刘恺 赵纯 漆云凤 何兵 周军 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第7期94-97,共4页
The stimulated Brillouin scattering (SBS) threshold enhancement factor in a pure white noise linewidth broad- ening Yb-doped fiber amplifier (YDFA) with a short large mode area fiber is theoretically and experimen... The stimulated Brillouin scattering (SBS) threshold enhancement factor in a pure white noise linewidth broad- ening Yb-doped fiber amplifier (YDFA) with a short large mode area fiber is theoretically and experimentally studied. We demonstrate a 1064.08nm, 11.6 GHz finewidth, 1.5 k W output power YDFA with an SBS threshold enhancement of -57 (26 W SBS threshold with single frequency seed). The output beam is near-diffraction lim- ited with a beam quality factor elM2 = 1.15 and a slope efficiency of up to 87%. No SBS or stimulated Raman scattering effects are observed in the whole power range. Further power sealing is limited by the available pump power in our system. 展开更多
关键词 SBS of Stimulated Brillouin Scattering Enhancement factor improvement in a 11.6-GHz-Linewidth 1.5-kW Yb-Doped Fiber Amplifier Yb is in GHz
下载PDF
Economical Optimization of Grid Power Factor Using Predictive Data 被引量:1
13
作者 Chaojiong Huang Jason Gu +2 位作者 Haiying Liu Yuansheng Lu Jun Luo 《IEEE/CAA Journal of Automatica Sinica》 EI CSCD 2019年第1期258-267,共10页
We present an electrical grid optimization method for economical benefit. After simplifying an IEEE feeder diagram, we build a compact smart grid system including a photovoltaic-inverter system, a shunt capacitor, an ... We present an electrical grid optimization method for economical benefit. After simplifying an IEEE feeder diagram, we build a compact smart grid system including a photovoltaic-inverter system, a shunt capacitor, an on-load tapchanger(OLTC) and transmission lines. The system power factor(PF) regulation and reactive power dispatching are indispensable to improve power quality. Our control method uses predictive weather and load data to decide engaging or tripping the shunt capacitor, or reactive power injection by the photovoltaic-inverter system, ultimately to keep the system PF in a good range. From the perspective of economics, the economical model is considered as a decision maker in our predictive data control method.Capacitor-only control strategy is a common photovoltaic(PV)regulation method, which is treated as a baseline case. Simulations with GridLAB-D on profiled loads and residential loads have been carried out. The comparison results with baseline control strategy and our predictive data control method show the appreciable economical benefit of our method. 展开更多
关键词 GRID OPTIMIZATION GridLAB-D inverter power factor PREDICTIVE DATA control SHUNT CAPACITOR
下载PDF
An Improved Non-isolated LED Converter with Power Factor Correction and Average Current Mode Control 被引量:1
14
作者 Renbo Xu Hongjian Li +1 位作者 Yongzhi Li Changqian Zhang 《Circuits and Systems》 2011年第3期242-248,共7页
A new type of high power LED drivers is proposed by adopting an improved two-stages non-isolated configuration. In order to improve power factor and achieve accurate average current control under universal input volta... A new type of high power LED drivers is proposed by adopting an improved two-stages non-isolated configuration. In order to improve power factor and achieve accurate average current control under universal input voltages ranging from 100 Vrms to 240 Vrms, the power factor correction and average current mode control methods operating in continuous current conduction mode are designed and implemented. With the LUMILEDS emitter type LEDs, a laboratory prototype is built and measured. And from the measured results, it could be concluded that the proposed driver has many better performances such as high power factor, low current harmonic, accurate average current control and switch protection. 展开更多
关键词 High power LED power factor CORRECTION AVERAGE Current Mode Control
下载PDF
Performance Evaluation of a Permanent Magnet Electric-Drive- Reconfigured Onboard Charger with Active Power Factor Correction 被引量:2
15
作者 Feng Yu Zhihao Zhu +1 位作者 Jingfeng Mao Juping Gu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期72-80,共9页
This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase perm... This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase permanent magnet synchronous motor(PMSM)propulsion system as a three-channel boost-type converter in which only a contactor and a small diode bridge are added.First,the operation scenario of the EDROC is introduced.Second,the relationship between electromagnetic torque and rotor position is investigated.Third,the current ripple cancellation of the EDROC is discussed in detail.Moreover,to implement the single-phase APFC along with charging voltage/current regulation of propulsion battery,control strategies including current balancing and synchronous/interleaving PWM strategies are incorporated.Finally,200W proof-of-concept prototype-based tests are conducted under different operation scenarios. 展开更多
关键词 Active power factor correction current balancing electric-drive-reconfigured electromagnetic torque INTERLEAVING onboard charger.
下载PDF
Power Factor Correction Rectifier with a Variable Frequency Voltage Source in Vehicular Application 被引量:1
16
作者 Amine Toumi Mohamed Radhouan Hachicha +1 位作者 Moez Ghariani Rafik Neji 《Intelligent Control and Automation》 2014年第1期1-11,共11页
This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in t... This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading effect on the alternator introduces harmonic currents and increases the alternator apparent power requirements. To overcome these problems and aiming more stability and better design of the alternator, a new third harmonic injection technique is proposed. This technique allows to preserve a good THD (Total Harmonic Distortion) of the input source at any frequency and to decrease losses in semiconductors switches, thereby allowing more stability and reducing the apparent power requirements. A comparative study between the standard and the new technique is made and highlights the effectiveness of the new design. A detailed analysis of the proposed topology is presented and simulations as well as experimental results are shown. 展开更多
关键词 ASYNCHRONOUS Machine Control-Oriented Vector of Rotor Flux PWM BOOST Converter HARMONIC Injection power factor Correction THREE-PHASE RECTIFIER JUNCTION Temperature
下载PDF
Dynamic grouping control of electric vehicles based on improved k-means algorithm for wind power fluctuations suppression 被引量:1
17
作者 Yang Yu Mai Liu +2 位作者 Dongyang Chen Yuhang Huo Wentao Lu 《Global Energy Interconnection》 EI CSCD 2023年第5期542-553,共12页
To address the significant lifecycle degradation and inadequate state of charge(SOC)balance of electric vehicles(EVs)when mitigating wind power fluctuations,a dynamic grouping control strategy is proposed for EVs base... To address the significant lifecycle degradation and inadequate state of charge(SOC)balance of electric vehicles(EVs)when mitigating wind power fluctuations,a dynamic grouping control strategy is proposed for EVs based on an improved k-means algorithm.First,a swing door trending(SDT)algorithm based on compression result feedback was designed to extract the feature data points of wind power.The gating coefficient of the SDT was adjusted based on the compression ratio and deviation,enabling the acquisition of grid-connected wind power signals through linear interpolation.Second,a novel algorithm called IDOA-KM is proposed,which utilizes the Improved Dingo Optimization Algorithm(IDOA)to optimize the clustering centers of the k-means algorithm,aiming to address its dependence and sensitivity on the initial centers.The EVs were categorized into priority charging,standby,and priority discharging groups using the IDOA-KM.Finally,an two-layer power distribution scheme for EVs was devised.The upper layer determines the charging/discharging sequences of the three EV groups and their corresponding power signals.The lower layer allocates power signals to each EV based on the maximum charging/discharging power or SOC equalization principles.The simulation results demonstrate the effectiveness of the proposed control strategy in accurately tracking grid power signals,smoothing wind power fluctuations,mitigating EV degradation,and enhancing the SOC balance. 展开更多
关键词 Electric vehicles Wind power fluctuation smoothing Improved k-means power allocation Swing door trending
下载PDF
Analysis of Starting Performance of High PowerFactor Induction Motor with Floating Windingin Parallel Connection with Capacitors
18
作者 ZHANG Qi XIE Guo dong (School of Automation, Shanghai University) 《Advances in Manufacturing》 SCIE CAS 1999年第4期299-303,共5页
In this paper, by using a matrix technique, a dynamic model of high power factor induction motor with floating winding in parallel connection with capacitors is established. Then, the starting performance of this mot... In this paper, by using a matrix technique, a dynamic model of high power factor induction motor with floating winding in parallel connection with capacitors is established. Then, the starting performance of this motor is analyzed by computer simulation. By comparison of the tested and computed results, which are in good agreement, the dynamic model and simulative method are verified. 展开更多
关键词 high power factor starting performance computer simulation
下载PDF
Isolated single stage high power factor AC/DC converter
19
作者 王卫 贲洪奇 高国安 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期334-337,共4页
The problem of harmonic pollution has brought wide attention with the increase of power customers. The adoption of the technology of active power factor correction (APFC) with advanced high frequency power converter i... The problem of harmonic pollution has brought wide attention with the increase of power customers. The adoption of the technology of active power factor correction (APFC) with advanced high frequency power converter is a more efficient solution to the problem of harmonic pollution. A single stage isolated high power factor AC/DC converter, which features wide range DC output, high power factor, lower harmonic pollution in input current, and phase shift PWM full bridge circuit can achieve soft switching. The principle of the circuit topology and the reasons of voltage surges across the power switch are analyzed. Experiment results illustrate that this circuit has the advantages of high power factor and lower harmonic distortion. 展开更多
关键词 single stage power factor correction CONVERTER voltage surge
下载PDF
The Security Correction of Large Consumers Long-Term Direct Power Trading Based on DC Power Transfer Distribution Factor
20
作者 Ouyang Xu Zhenggang Wang +3 位作者 Bifeng Lv Jinguo Zhang Jiangang Yao Bin Wang 《Energy and Power Engineering》 2017年第4期365-375,共11页
The experiments of large consumers direct power trading is conducting in china nationwide, and it’s important to the reform of electricity market. To compensated efficiencies in security correction of large consumers... The experiments of large consumers direct power trading is conducting in china nationwide, and it’s important to the reform of electricity market. To compensated efficiencies in security correction of large consumers direct power trading, a novel security correction method based on DC power transfer distribution factor was proposed. Using the presented method to comply security correction, all the transactions that satisfy the specific requirements of maximizing social welfare are able to enter security correction process, and when the power of transmission line is out of limit, this method avoid the transaction which causes this problem is abandoned directly by introducing supplement transactions. The simulation has shown that the proposed security correction method of large consumers direct power trading based on DC power transfer distribution factor is effective. 展开更多
关键词 Large CONSUMERS Direct power TRADING DC power TRANSFER Distribution factor SECURITY CORRECTION Electricity Markets
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部