A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of...A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of the continuity equation allowed us to present the equations of photocurrent density, photovoltage and electric power. The influence of the angle of incidence of the magnetic field on the photocurrent density, the photovoltage and the electric power has been studied. The curves of electrical power versus dynamic junction velocity were used to extract the values of maximum electrical power and dynamic junction velocity and to calculate those of conversion efficiency. From this study, it is found that the conversion efficiency values increase with the angle of incidence of the magnetic field.展开更多
An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of succe...An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.展开更多
The technique of organic exhaust gas decomposition with impulse corono dischrge plasma has been investigated in this study. It has been discovered that the impulse electric field affected the decomposition efficiency ...The technique of organic exhaust gas decomposition with impulse corono dischrge plasma has been investigated in this study. It has been discovered that the impulse electric field affected the decomposition efficiency with the secondary electron emission coefficient (δ) of the corona electrode as an intermediary: when the impulse voltage power ( W ) was fixed the corona electrode material with higher δ could induce higher decomposition efficiency. In these experiments, wolfram electrode which has the highest δ has really induced the highest decomposition efficiency.展开更多
Removal of the electrical shielding from a type of Fourier transform seismometer overlays seismic information with Extremely Low Frequency-range (ELF) electromagnetic signals between about 0.3 Hz and 36 Hz (the ITU-de...Removal of the electrical shielding from a type of Fourier transform seismometer overlays seismic information with Extremely Low Frequency-range (ELF) electromagnetic signals between about 0.3 Hz and 36 Hz (the ITU-designated range of ELF is 3 to 30 Hz). The observed signals originate in the electric power grid, shown clearly by the fact that they are sum and difference heterodyne products with the power grid’s higher harmonics of 60 Hz, typically the 36th and 37th, because the seismometer’s chosen frequency modulation (FM) carrier frequency is roughly 2200 Hz. It is especially interesting that on 2017-03-19, prior to 14:25:12 UTC, the instrument recorded an 11 minute sequence of 20.3 Hz ELF outbursts that culminated intimately with a 3.2 magnitude earthquake located a few miles west of Bardwell KY. These ~20.3 Hz ELF signals, very near the third Schumann resonance frequency, have been recorded numerous times. They are distinctive and fairly strong, ranging 15 to 30 db or more above the noise floor, but definitely not an every-day event;months can pass without them. So far most of these ELF signals do not have an intimately associated earthquake, with the event of 2017-03-19 being one of only two exceptions recorded thus far. That quake’s location was more than one hundred miles from the instrument, in the New Madrid Seismic Zone (NMSZ). The second case, a quake in Kansas, was about three times farther from the instrument, and its ELF signals were correspondingly weaker. Those other, unassociated electromagnetic events might come from quakes too weak to detect, but it should be noted that stronger, easily detected quakes also rarely exhibit any ELF/seismic “connectivity”. This paper describes an instrument that overlays ELF, electric field and seismic signals. The instrument’s two-dimensional (2D) output has a time axis (horizontal) resolution of ~3 seconds and an ELF frequency (vertical) resolution of ~0.3 Hz.展开更多
The air breakdown is easily caused by the high-power microwave, which can have two mutually orthogonal and heterophase electric field components. For this case, the electron momentum conservation equation is employed ...The air breakdown is easily caused by the high-power microwave, which can have two mutually orthogonal and heterophase electric field components. For this case, the electron momentum conservation equation is employed to deduce the electric field power and effective electric field for heating electrons. Then the formula of the electric field power is introduced into the global model to simulate the air breakdown. The breakdown prediction from the global model agrees well with the experimental data. Simulation results show that the electron temperature is sensitive to the phase difference between the two electron field components, while the latter can affect obviously the growth of the electron density at low electron temperature amplitudes. The ionization of nitrogen and oxygen induces the growth of electron density, and the density loss due to the dissociative attachment and dissociative recombination is obvious only at low electron temperatures.展开更多
将无线电能传输技术引入航天器的旋转供电中是推动航天器进一步发展的重要手段。而现有应用最广的磁耦合式无线电能传输技术(inductive power transfer,IPT)因成本高、重量大、存在涡流损耗等缺陷而难以在航天领域中得到大规模应用。而...将无线电能传输技术引入航天器的旋转供电中是推动航天器进一步发展的重要手段。而现有应用最广的磁耦合式无线电能传输技术(inductive power transfer,IPT)因成本高、重量大、存在涡流损耗等缺陷而难以在航天领域中得到大规模应用。而电场耦合式无线电能传输技术(capacitive power transfer,CPT)以其成本低、重量轻等优点,近年来受到广泛关注,在航天领域具有巨大潜力。从传统IPT技术在航天领域应用的缺陷入手,分析将CPT技术引入航天领域无线供电场景的重要性。进而介绍了CPT技术的发展历程与基本原理,并对CPT技术在轻量化、大功率、旋转型三个领域的研究现状进行综述来论证其在航天领域应用的潜力。最后总结了CPT技术在航天领域应用存在的问题并分析了解决这些问题可行的技术手段。展开更多
文摘A three-dimensional approach to the effect of magnetic field incidence angle on electrical power and conversion efficiency is performed on a front-illuminated polycrystalline silicon bifacial solar cell. A solution of the continuity equation allowed us to present the equations of photocurrent density, photovoltage and electric power. The influence of the angle of incidence of the magnetic field on the photocurrent density, the photovoltage and the electric power has been studied. The curves of electrical power versus dynamic junction velocity were used to extract the values of maximum electrical power and dynamic junction velocity and to calculate those of conversion efficiency. From this study, it is found that the conversion efficiency values increase with the angle of incidence of the magnetic field.
基金supported by National Basic Research Program of China(973 Program)(2011CB209404)
文摘An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.
文摘The technique of organic exhaust gas decomposition with impulse corono dischrge plasma has been investigated in this study. It has been discovered that the impulse electric field affected the decomposition efficiency with the secondary electron emission coefficient (δ) of the corona electrode as an intermediary: when the impulse voltage power ( W ) was fixed the corona electrode material with higher δ could induce higher decomposition efficiency. In these experiments, wolfram electrode which has the highest δ has really induced the highest decomposition efficiency.
文摘Removal of the electrical shielding from a type of Fourier transform seismometer overlays seismic information with Extremely Low Frequency-range (ELF) electromagnetic signals between about 0.3 Hz and 36 Hz (the ITU-designated range of ELF is 3 to 30 Hz). The observed signals originate in the electric power grid, shown clearly by the fact that they are sum and difference heterodyne products with the power grid’s higher harmonics of 60 Hz, typically the 36th and 37th, because the seismometer’s chosen frequency modulation (FM) carrier frequency is roughly 2200 Hz. It is especially interesting that on 2017-03-19, prior to 14:25:12 UTC, the instrument recorded an 11 minute sequence of 20.3 Hz ELF outbursts that culminated intimately with a 3.2 magnitude earthquake located a few miles west of Bardwell KY. These ~20.3 Hz ELF signals, very near the third Schumann resonance frequency, have been recorded numerous times. They are distinctive and fairly strong, ranging 15 to 30 db or more above the noise floor, but definitely not an every-day event;months can pass without them. So far most of these ELF signals do not have an intimately associated earthquake, with the event of 2017-03-19 being one of only two exceptions recorded thus far. That quake’s location was more than one hundred miles from the instrument, in the New Madrid Seismic Zone (NMSZ). The second case, a quake in Kansas, was about three times farther from the instrument, and its ELF signals were correspondingly weaker. Those other, unassociated electromagnetic events might come from quakes too weak to detect, but it should be noted that stronger, easily detected quakes also rarely exhibit any ELF/seismic “connectivity”. This paper describes an instrument that overlays ELF, electric field and seismic signals. The instrument’s two-dimensional (2D) output has a time axis (horizontal) resolution of ~3 seconds and an ELF frequency (vertical) resolution of ~0.3 Hz.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61501358,61431010,and 61627901)the Fundamental Research Funds for the Central Universities,China
文摘The air breakdown is easily caused by the high-power microwave, which can have two mutually orthogonal and heterophase electric field components. For this case, the electron momentum conservation equation is employed to deduce the electric field power and effective electric field for heating electrons. Then the formula of the electric field power is introduced into the global model to simulate the air breakdown. The breakdown prediction from the global model agrees well with the experimental data. Simulation results show that the electron temperature is sensitive to the phase difference between the two electron field components, while the latter can affect obviously the growth of the electron density at low electron temperature amplitudes. The ionization of nitrogen and oxygen induces the growth of electron density, and the density loss due to the dissociative attachment and dissociative recombination is obvious only at low electron temperatures.
文摘将无线电能传输技术引入航天器的旋转供电中是推动航天器进一步发展的重要手段。而现有应用最广的磁耦合式无线电能传输技术(inductive power transfer,IPT)因成本高、重量大、存在涡流损耗等缺陷而难以在航天领域中得到大规模应用。而电场耦合式无线电能传输技术(capacitive power transfer,CPT)以其成本低、重量轻等优点,近年来受到广泛关注,在航天领域具有巨大潜力。从传统IPT技术在航天领域应用的缺陷入手,分析将CPT技术引入航天领域无线供电场景的重要性。进而介绍了CPT技术的发展历程与基本原理,并对CPT技术在轻量化、大功率、旋转型三个领域的研究现状进行综述来论证其在航天领域应用的潜力。最后总结了CPT技术在航天领域应用存在的问题并分析了解决这些问题可行的技术手段。