Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportio...Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.展开更多
The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and stu...The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.展开更多
New design solutions have been proposed for a BRS-GPG type reactor circuit, which are different from transport and stationary low and medium-powered reactor installations cooled with heavy liquid-metal coolants, and w...New design solutions have been proposed for a BRS-GPG type reactor circuit, which are different from transport and stationary low and medium-powered reactor installations cooled with heavy liquid-metal coolants, and which correspond to the evolutionary development of such installations. While developing these solutions, the available experience in creating and operating So</span><span>viet pilot and commercial power plants cooled with lead-bismuth coolants</span><span> was used, including investigations, primarily experimental ones, carried out by team of authors in justification of a capacity range (50</span></span><span> </span><span>-</span><span> </span><span>250 MW) of low and medium-powered reactor plants with horizontal steam generators (BRS-</span><span> </span><span>GPG) proposed and elaborated at the NNSTU.展开更多
The design and implementation of a Generalized Predictive Control(GPC)strategy for the superheated steam temperature regulation in a supercritical(SC)coal-fired power plant is presented.A Controlled Auto-Regressive Mo...The design and implementation of a Generalized Predictive Control(GPC)strategy for the superheated steam temperature regulation in a supercritical(SC)coal-fired power plant is presented.A Controlled Auto-Regressive MovingAverage(CARMA)model of the plant is derived from using the experimental data to approximately predict the plant’s future behavior.This model is required by the GPC algorithm to calculate the future control inputs.A new GPC controller is designed and its performance is tested through extensive simulation studies.Compared with the performance of the plant using a conventional PID controller,the steam temperature controlled by the GPC controller is found to be more stable.The stable steam temperature leads to more efficient plant operation and energy saving,as demonstrated by the simulation results.Plant performance improvement is also tested while the plant experiences the load demand changes and disturbances resulting from the malfunctioning of coal mills.展开更多
基金Supported by the National Natural Science Foundation of China (61174059, 60934007, 61233004)the National Basic Research Program of China (2013CB035406)Shanghai Rising-Star Tracking Program (11QH1401300)
文摘Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.
文摘The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.
文摘New design solutions have been proposed for a BRS-GPG type reactor circuit, which are different from transport and stationary low and medium-powered reactor installations cooled with heavy liquid-metal coolants, and which correspond to the evolutionary development of such installations. While developing these solutions, the available experience in creating and operating So</span><span>viet pilot and commercial power plants cooled with lead-bismuth coolants</span><span> was used, including investigations, primarily experimental ones, carried out by team of authors in justification of a capacity range (50</span></span><span> </span><span>-</span><span> </span><span>250 MW) of low and medium-powered reactor plants with horizontal steam generators (BRS-</span><span> </span><span>GPG) proposed and elaborated at the NNSTU.
基金supported by the EPSRC Grant(EP/G062889/2),Advantage West Midlands and the European Regional Development Agency(Birmingham Science City Energy Efficiency&Demand Reduction project).
文摘The design and implementation of a Generalized Predictive Control(GPC)strategy for the superheated steam temperature regulation in a supercritical(SC)coal-fired power plant is presented.A Controlled Auto-Regressive MovingAverage(CARMA)model of the plant is derived from using the experimental data to approximately predict the plant’s future behavior.This model is required by the GPC algorithm to calculate the future control inputs.A new GPC controller is designed and its performance is tested through extensive simulation studies.Compared with the performance of the plant using a conventional PID controller,the steam temperature controlled by the GPC controller is found to be more stable.The stable steam temperature leads to more efficient plant operation and energy saving,as demonstrated by the simulation results.Plant performance improvement is also tested while the plant experiences the load demand changes and disturbances resulting from the malfunctioning of coal mills.