期刊文献+
共找到6,095篇文章
< 1 2 250 >
每页显示 20 50 100
Simulation of Underground Reservoir Stability of Pumped Storage Power Station Based on Fluid-Structure Coupling
1
作者 Peng Qiao Shuangshuang Lan +1 位作者 Hongbiao Gu Zhengtan Mao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1381-1399,共19页
Based on global initiatives such as the clean energy transition and the development of renewable energy,the pumped storage power station has become a new and significant way of energy storage and regulation,and its co... Based on global initiatives such as the clean energy transition and the development of renewable energy,the pumped storage power station has become a new and significant way of energy storage and regulation,and its construction environment is more complex than that of a traditional reservoir.In particular,the stability of the rock strata in the underground reservoirs is affected by the seepage pressure and rock stress,which presents some challenges in achieving engineering safety and stability.Using the advantages of the numerical simulation method in dealing deal with nonlinear problems in engineering stability,in this study,the stability of the underground reservoir of the Shidangshan(SDS)pumped storage power station was numerically calculated and quantitatively analyzed based on fluid-structure coupling theory,providing an important reference for the safe operation and management of the underground reservoir.First,using the COMSOL software,a suitablemechanicalmodel was created in accordance with the geological structure and project characteristics of the underground reservoir.Next,the characteristics of the stress field,displacement field,and seepage field after excavation of the underground reservoir were simulated in light of the seepage effect of groundwater on the nearby rock of the underground reservoir.Finally,based on the construction specifications and Molar-Coulomb criterion,a thorough evaluation of the stability of the underground reservoir was performed through simulation of the filling and discharge conditions and anti-seepage strengthening measures.The findings demonstrate that the numerical simulation results have a certain level of reliability and are in accordance with the stress measured in the project area.The underground reservoir excavation resulted in a maximum displacement value of the rock mass around the caverns of 3.56 mm in a typical section,and the safety coefficient of the parts,as determined using the Molar-Coulomb criterion,was higher than 1,indicating that the project as a whole is in a stable state. 展开更多
关键词 Underground reservoir fluid-structure coupling numerical simulation pumped storage power station filling and discharge
下载PDF
Study on integrated development and hybrid operation mode of nuclear power plant and pumped-storage power station 被引量:6
2
作者 Haizheng Wang Caide Peng 《Global Energy Interconnection》 2019年第4期336-341,共6页
The nuclear power plant is suitable for base-load operation, while the pumped-storage unit mainly gives play to capacity benefit in the electric power system;hence, the integrated development and hybrid operation mode... The nuclear power plant is suitable for base-load operation, while the pumped-storage unit mainly gives play to capacity benefit in the electric power system;hence, the integrated development and hybrid operation mode of the two can better meet the needs of the electric power system. This article first presents an analysis of the necessity and superiority of such mode, then explains its meaning and analyzes the working routes. Finally, it proposes the business modes as follows: low price pumping water electricity plus nuclear power in the near term;nuclear power shifted to pumped storage power participating in market competition in the middle term;and, in the long term, nuclear power shifted to pumped storage power as primary and serving as an electric power system when needed. 展开更多
关键词 NUCLEAR power PLANT pumped-storage power STATION Integrated development HYBRID operation MODES
下载PDF
Prospect of new pumped-storage power station 被引量:4
3
作者 Jingyan Li Chuanbao Yi Sujie Gao 《Global Energy Interconnection》 2019年第3期235-243,共9页
In this paper, a new type of pumped-storage power station with faster response speed, wider regulation range, and better stability is proposed. The operational flexible of the traditional pumped-storage power station ... In this paper, a new type of pumped-storage power station with faster response speed, wider regulation range, and better stability is proposed. The operational flexible of the traditional pumped-storage power station can be improved with variable-speed pumped-storage tech no logy. Combined with chemical en ergy storage, the failure to achieve sec on d-order response speed and the insufficient safety and reliability of pumped-storage power units could be solved. With the better solar en ergy and site resources, the in teg rated performance can be improved by an optical storage system in stalled in future pumped-storage stations. Through the characteristics analysis of the new type of pumped-storage power station, three types of optimal station locations are proposed, namely, the load concentration area, new energy concentration area, and ultrahigh- voltage direct current receiver area. Taking the new pumped-storage power station as an example, the advantages of multi-energy cooperation and joint operation are analyzed. It can be predicted that the frequency and load regulation of the power grid will be more flexible, and the service capacity to the main power grid will be much stronger in the future. 展开更多
关键词 pumped-storage power STATION Variable-speed pumped-storage technology CHEMICAL ENERGY STORAGE Solarenergy STORAGE system
下载PDF
A novel technology for control of variable speed pumped storage power plant 被引量:1
4
作者 Seyed Mohammad Hassan Hosseini Mohammad Reza Semsar 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2008-2023,共16页
Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V... Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux. 展开更多
关键词 direct torque and flux control(DTFC) two-level three-level voltage source converter(2LVSC&3LVSC) variable speed pumped storage power plant(VSPSP)
下载PDF
Energy-Transfer Processes of Xe(6p[1/2]0,6p[3/2]2,and 6p[5/2]2) Atoms under the Condition of Ultrahigh Pumped Power
5
作者 Shan He Jun-zhi Chu +9 位作者 Dong Liu Xue-yang Li Jing-wei Guo Jin-bo Liu Shu Hu Hui Li Peng-yuan Wang Ying Chen Feng-ting Sang Yu-qi Jin 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2018年第6期741-748,733,共9页
The kinetic processes of Xe(6p[1/2]0, 6p[3/2]2, and 6p[5/2]2) atoms under the focused condition were investigated. The atomic density of the laser prepared state significantly increases. Therefore, the probability of ... The kinetic processes of Xe(6p[1/2]0, 6p[3/2]2, and 6p[5/2]2) atoms under the focused condition were investigated. The atomic density of the laser prepared state significantly increases. Therefore, the probability of the energy-pooling between two high-lying atoms increases. There are three major types of the energy-pooling collisions. The first type is the energy-pooling ionization. Once the excitation laser is focused, the obvious ionization can be observed from the side window whenever the laser prepared state is 6p[1/2]0, 6p[3/2]2, or 6p[5/2]2 state. Ionization of Xe is attributed to the energy-pooling ionization or a Xe* atom reabsorbing another excitation photon. The second type is energy-pooling with big energy difference. When the 6p[1/2]0 state is the laser prepared state, the energy-pooling collision between two 6p[1/2]0 atoms can produce one 5d[3/2]1 atom and one 6s'[1/2]0 atom. The third type is energy-pooling with small energy difference. The intensities of fluorescence lines are much stronger that five secondary 6p states act as the upper states, and the rising edges of these fluorescence lines are much steeper. The primary mechanism of generating the secondary 6p atoms is energy-pooling collision instead of collision relaxation. Based on the collision probability, the rate of energy-pooling between two 6p[1/2]0 atoms is deduced (6.39x10^8s-1). In addition, the 6s atoms also increase under the focused condition. Therefore, all the fluorescence lines are serious trailing by radiation trapping. 展开更多
关键词 Energy-pooling KINETICS XE Ultrahigh pumped power
下载PDF
High power external-cavity surface-emitting laser with front and end pump
6
作者 Lidan Jiang Renjiang Zhu +4 位作者 Maohua Jiang Dingke Zhang Yuting Cui Peng Zhang Yanrong Song 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期265-269,共5页
High power optically pumped vertical-external-cavity surface-emitting lasers with front and end pump are re- ported. The gain chip consists of 15 repeats of In0.26GaAs/GaAsP0.02 multiple quantum wells and 30 pairs of ... High power optically pumped vertical-external-cavity surface-emitting lasers with front and end pump are re- ported. The gain chip consists of 15 repeats of In0.26GaAs/GaAsP0.02 multiple quantum wells and 30 pairs of Alo.2GaAs/Alo.98GaAs distributed Bragg reflectors. The maximum output power of 3 W, optical-to-optical conversion efficiency of 22.4%, and slope efficiency of 29.8% are obtained with 5-℃ heatsink temperature under the front pump, while the maximum output power of 1.1 W, optical-to-optical conversion efficiency of 23.2%, and slope efficiency of 30.8% are reached with 5-℃ heatsink temperature under the end pump. Influences of thermal effects on the output power of the laser with front and end pump are discussed. 展开更多
关键词 surface-emitting laser EXTERNAL-CAVITY high power pump geometry
下载PDF
Analytical Expression of the Threshold Pump Power of Erbium-doped Fiber Lasers Pumped at 980nm and 1480nm Wavelengths
7
作者 XIA Guangqiong WU Zhengmao ZHENG Ruilun(Southwest Normal University,Chongqing 630715,CHN)CHEN Jianguo(Sichuan University,Chengdu 610064,CHN ) 《Semiconductor Photonics and Technology》 CAS 1996年第2期99-102,共4页
The rate equations,which is suitable to erbium-doped fiber lasers pumped at 980 nm and 1 480nm wavelengths respectively,are investigated,and analytical expressions of the threshold pump powers under two pump wavelengt... The rate equations,which is suitable to erbium-doped fiber lasers pumped at 980 nm and 1 480nm wavelengths respectively,are investigated,and analytical expressions of the threshold pump powers under two pump wavelengths are derived.As a result,some important parameters can be quantitatively specified. 展开更多
关键词 Fiber Lasers Soliton Transmission Threshold pump power
下载PDF
Power Stabilization System with Counter-Rotating Type Pump-Turbine Unit for Renewable Energy
8
作者 Toru Miyaji Risa Kasahara +3 位作者 Toshiaki Kanemoto Jin-Hyuk Kim Young-Seok Choi Toshihiko Umekage 《Journal of Power and Energy Engineering》 2014年第4期47-52,共6页
Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. The pump-turbine unit is prepared for the power stabilization system, in this serial researc... Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. The pump-turbine unit is prepared for the power stabilization system, in this serial research, to provide the constant power with good quality for the grid system, even at the suddenly fluctuating/turbulent output from renewable energies. In the unit, the angular momentum changes through the front impeller/runner must be the same as that through the rear impeller/runner, that is, the axial flow at the outlet should be the same to the axial flow at the inlet. Such flow conditions are advantageous to work at not only the pumping mode but also the turbine mode. This work discusses experimentally the performance of the unit, and verifies that this type unit is very effective to both operating modes. 展开更多
关键词 power STABILIZATION pump-TURBINE Counter-Rotation IMPELLER Generator Motor
下载PDF
Power Stabilization by Windfarm Applied Statistical Model and Pumped Storage Generation Using Archimedean Screw
9
作者 Hiroya Mitsuyose Daichi Mizuse +1 位作者 Hiroatsu Fujiwara Akira Sugawara 《Journal of Mechanics Engineering and Automation》 2015年第12期681-686,共6页
In this paper, a method of stabilizing electric power by a system which is a combination of wind power generation and pumped storage power generation is proposed. The system operates based on the output predicted valu... In this paper, a method of stabilizing electric power by a system which is a combination of wind power generation and pumped storage power generation is proposed. The system operates based on the output predicted value of the windfarm. When the measured windfarm output is larger than the predicted value, the system is pumping up water with surplus power. When the windfarm output is smaller than the predicted value, the system is filling up lack power by hydro generator. Also, since hydro generator works with a start-up delay time, output shortage occurs at this time. To improve output shortage at the time, we estimate the time below the predicted value by a statistical model. As the result, the system succeeded in stabilizing the power and improving the start-up delay time of the hydro generator. 展开更多
关键词 Windfarm pumped storage power generation Archimedean screw statistical model.
下载PDF
Research on single hole heat transfer power of ground source heat pump system 被引量:2
10
作者 ZHAO Fang-hua 《Journal of Groundwater Science and Engineering》 2018年第1期65-70,共6页
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe... In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data. 展开更多
关键词 GROUND source HEAT pump Monitoring HEAT TRANSFER power Thermal response test
下载PDF
STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY 被引量:1
11
作者 QiuBaoyun HuangJiyan YuanShouqi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第4期498-501,共4页
Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probabilit... Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probability density function is determined. Influences ofmultiple factors on pump shaft power are analyzed. Method of calculating none over-loadedprobability of motor by integration by successive reductions is put forward and then relationbetween power spare coefficient and none over-loaded reliability of electric motor is established.Influences of all factors on pump shaft power being considered completely; power spare coefficientsof motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-outconditions. Electrical motor power spare coefficients should be chosen as 1.20 approx 1.44, 1.11approx 1.19, 1.09 approx.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much toreasonable choose of electrical motors in large pump stations, increasing reliability of pump unitsand saving equipment investment. 展开更多
关键词 Large pump station Electrical motor power spare coefficient Probability ofnone over-loaded
下载PDF
Optimal Dispatching Model Considering the Pumped Sto-rage Power Plant in Hunan
12
作者 Xinfan Jiang Dunnan Liu +1 位作者 Siyuan Zhang Wenlei Zhang 《Energy and Power Engineering》 2013年第4期608-611,共4页
This paper made a research on the Intelligent Optimization Operating Modeling of Pumped Storage Power Station in Hunan Power Grid. First it introduces the characteristics of Hunan power grid and analysis the practical... This paper made a research on the Intelligent Optimization Operating Modeling of Pumped Storage Power Station in Hunan Power Grid. First it introduces the characteristics of Hunan power grid and analysis the practical requirement of dispatching. Then it brings forward the intelligent optimization model and set up running model for pumped storage power station of Hei Mi-feng. At last, it introduces the application of pumped storage power station in Hunan power grid and proves the effectiveness of the optimization models. 展开更多
关键词 Intelligent Optimization DISPATCHING Model pumpED Storage power STATION
下载PDF
Test Facility for Low Potential Pumped Storage Power Plants and Hydrokinetic Turbines
13
作者 Dominik Surek 《Journal of Energy and Power Engineering》 2013年第11期2037-2044,共8页
The electric energy which is generated by wind power plants depends on the wind speed and exceeds with strong permissible wind speed the electric energy requirements of the country. In order not to reduce this electri... The electric energy which is generated by wind power plants depends on the wind speed and exceeds with strong permissible wind speed the electric energy requirements of the country. In order not to reduce this electrical energy, it must be stored. The sensible energy storage is currently the pumped storage power plants. As the mountain ranges for conventional pumped storage power plants with drop heights of H 〉 600 m are strictly limited, the development of low potential pumped storage power plants has begun. Increasing the capacity of pumped storage power plants with regard to the wind power plants is urgently needed. In this paper, it is shown using the example of an unneeded port facility, how a port facility can be used after low conversion as a test facility for low potential pumped storage power plants and at the same time for the testing of hydro-kinetic turbines. This type of pump storage power plants does not save the energy due to large drop heights, but primarily due to the large volume flow of water. 展开更多
关键词 Energy storage pumped storage power plant wind energy photovoltaic.
下载PDF
Behavioral Variations of Gain and NF Owing to Configurations and Pumping Powers
14
作者 Belloui Bouzid 《Optics and Photonics Journal》 2012年第1期8-12,共5页
Six configurations are proposed in this paper to explore the gain and noise figure (NF) variations under the pumping power effect. I propose a new investigation of gain and NF at different EDFA configurations. Configu... Six configurations are proposed in this paper to explore the gain and noise figure (NF) variations under the pumping power effect. I propose a new investigation of gain and NF at different EDFA configurations. Configurations such as SPSS, DPSS, DPSSF, TPDS, TPDSF, and QPDSF are designed, investigated and compared. A continuous progress of gain values is observed from SPSS to QPDSF, and a change of NF values related to configurations is recorded. The NF variations show different behaviors at different configurations. High gain of 59.49 dB and low NF value of 4.22 dB are recorded for the QPDSF configuration and low gain and low NF are recorded for the SPSS configuration. 展开更多
关键词 Double PASS Single PASS ERBIUM Doped Fiber Configuration pumpING power
下载PDF
Equivalent Substitution Based Method for Calculation of Best Installed Capacity of Pumped Storage Power Station
15
作者 Jinming Li Tao Yu Huaizhi Wang 《Energy and Power Engineering》 2013年第3期46-51,共6页
This paper proposes a novel method to calculate the best installed capacity of pumped storage power station. First, we choose the day with maximum load as the typical day for every month and simulate the system runnin... This paper proposes a novel method to calculate the best installed capacity of pumped storage power station. First, we choose the day with maximum load as the typical day for every month and simulate the system running in two cases of whether the pumped storage power station is put into operation. The difference of the total coal consumption between the two cases is the peak load shifting benefit. Furthermore, we build load model and power generation model to calculate the benefit of emergency use and frequency modulation, which are the major projects of dynamic benefits. At last, on the premise of ensuring the system requirements, the developed method employs the maximum benefit of the unit capacity as the objective function to get the best installed capacity of pumped storage power station by simulations. Tests on a provincial power grid have shown that the developed method which combines of load characteristics, electric structure and other factors can get the best installed capacity of pumped storage power station easily and has a certain guiding significance for the planning and construction of the pumped storage power station. 展开更多
关键词 STATIC BENEFITS Dynamic BENEFITS pumpED STORAGE power STATION Best Installed Capacity
下载PDF
NB/T 35009-2024修订内容解读及抽水蓄能电站标准化工作历程回顾
16
作者 高洁 岳蕾 朱方亮 《中国标准化》 2024年第15期148-152,共5页
本文回顾了抽水蓄能电站选点规划标准化工作历程,从90年代选点规划工作范围逐步扩展,一批代表性站点规划落地,选点规划思想逐渐成熟,首版标准于2003年编制完成。到2009年全国范围抽水蓄能电站选点规划系统性开展,继22个省(区、市)完成... 本文回顾了抽水蓄能电站选点规划标准化工作历程,从90年代选点规划工作范围逐步扩展,一批代表性站点规划落地,选点规划思想逐渐成熟,首版标准于2003年编制完成。到2009年全国范围抽水蓄能电站选点规划系统性开展,继22个省(区、市)完成选点工作,第二版标准修订完成,有效指导了实践工作。随着抽水蓄能电站选点规划的管理流程和技术路线不断成熟,选点规划已成为前期工作和开工建设的重要基础。双碳目标提出以来,抽水蓄能中长期发展规划为行业发展带来新机遇新挑战,第三版标准修订工作适时开展,区分功能定位、明确技术要求,积极响应了当前新能源和抽水蓄能行业高质量发展的要求。 展开更多
关键词 抽水蓄能电站选点规划 抽水蓄能发展规划 抽水蓄能电站技术标准体系
下载PDF
计及深度调峰的风-光-水-火-抽蓄多能源联网系统优化调度研究 被引量:2
17
作者 李卫国 丁硕 +1 位作者 安祎宁 蔡婷婷 《东北电力大学学报》 2024年第3期83-93,共11页
多种能源联网运行逐步成为未来电力系统发展的方向,多能源联网系统的优化调度是应对规模化新能源并网消纳的重要手段。文中建立了计及火电机组深度调峰成本的风-光-水-火-抽蓄联网系统成本模型和考虑调峰主动性的风-光-水-火-抽蓄联网... 多种能源联网运行逐步成为未来电力系统发展的方向,多能源联网系统的优化调度是应对规模化新能源并网消纳的重要手段。文中建立了计及火电机组深度调峰成本的风-光-水-火-抽蓄联网系统成本模型和考虑调峰主动性的风-光-水-火-抽蓄联网系统日前优化调度模型。针对多能源耦合系统结构复杂的情况,提出了分层优化调度的模型求解策略。上层模型以净负荷波动最小为优化目标,得到等效负荷曲线;下层模型根据上层模型的调度结果,以调峰运行的经济性最优和新能源弃电率最低为目标函数,计及调峰主动性,求解考虑火电机组深度调峰煤耗特性的含新能源系统的经济调度问题。仿真算例表明所建模型实现了多能源联网系统的互补运行,提升了火电机组的深度调峰能力,降低新能源弃电率和系统运行成本。 展开更多
关键词 多能源系统 抽水蓄能电站 深度调峰 优化调度 调峰主动性
下载PDF
竖井式进出水口水力特性研究进展
18
作者 高学平 袁野 +1 位作者 朱洪涛 刘殷竹 《水力发电学报》 CSCD 北大核心 2024年第9期13-26,共14页
竖井式进出水口是抽水蓄能电站水道系统两端控制水流的常用进出水口型式之一。竖井式进出水口双向过流,水流在短距离内经历两次90°流向转变(水平-竖直-水平),流向变化剧烈,水力条件复杂,深入研究竖井式进出水口水力特性,进而优化... 竖井式进出水口是抽水蓄能电站水道系统两端控制水流的常用进出水口型式之一。竖井式进出水口双向过流,水流在短距离内经历两次90°流向转变(水平-竖直-水平),流向变化剧烈,水力条件复杂,深入研究竖井式进出水口水力特性,进而优化其体型结构,对抽水蓄能电站设计及施工具有重要意义。首先,介绍竖井式进出水口应用背景及体型特点,分析竖井式进出水口水力特性存在的问题;其次,对竖井式进出水口孔口流量分配、拦污栅断面流速分布、漩涡和水头损失等方面研究进展进行总结;最后,归纳了竖井式进出水口水力特性研究方法,探讨了今后研究应聚焦的主要方向。 展开更多
关键词 抽水蓄能电站 竖井式进出水口 水力特性 研究方法
下载PDF
混合式抽水蓄能电站对下泄水温影响的数值模拟研究
19
作者 余丹 杨世伟 +1 位作者 陈俊光 梁瑞峰 《灌溉排水学报》 CAS CSCD 2024年第9期75-81,共7页
【目的】混合式抽水蓄能电站运行特性与常规电站相比存在差异,本文旨在掌握抽水蓄能电站水温的变化规律,为水库管理调度提供参考。【方法】以紧水滩水库为研究对象,采用MIKE3水温模型模拟不同进/出水口高程以及不同抽水流量工况的下泄水... 【目的】混合式抽水蓄能电站运行特性与常规电站相比存在差异,本文旨在掌握抽水蓄能电站水温的变化规律,为水库管理调度提供参考。【方法】以紧水滩水库为研究对象,采用MIKE3水温模型模拟不同进/出水口高程以及不同抽水流量工况的下泄水温,据此探讨混合式抽水蓄能电站对下泄水温的影响。【结果】抽蓄水流会对下泄水温产生影响,相对于现状无抽水工况的下泄水温,抽蓄工况下的下泄水温基本表现为5—9月略有下降,其余月份略有升高,下泄水温的最大降幅不超过0.7℃,最大升幅不超过0.8℃。【结论】进/出水口高程对于下泄水温影响较大,且高程越低,下泄水温差异越大。然而抽水流量对于下泄水温差异影响并不显著,但整体上也呈现出随着抽水流量增加,水温差异增大的趋势。 展开更多
关键词 抽水蓄能电站 下泄水温 进/出水口高程 抽水流量 数值模拟
下载PDF
基于抽蓄协调的新能源纳入电力系统备用方法
20
作者 孟高军 钱聪聪 +2 位作者 于琳琳 程昱明 贾鹏 《太阳能学报》 EI CAS CSCD 北大核心 2024年第10期162-170,共9页
大规模新能源并网后,传统的备用体系制约含高比例新能源电力系统的新能源消纳能力。为此,该文提出基于抽蓄协调的新能源纳入电力系统备用方法。首先,采用改进K-均值聚类算法生成各时段新能源出力预测典型场景;然后,基于广义新能源预测... 大规模新能源并网后,传统的备用体系制约含高比例新能源电力系统的新能源消纳能力。为此,该文提出基于抽蓄协调的新能源纳入电力系统备用方法。首先,采用改进K-均值聚类算法生成各时段新能源出力预测典型场景;然后,基于广义新能源预测偏差及弃用风险约束,确定各时段各典型场景的最佳新能源纳入备用比例系数;最后,根据各时段的新能源预测数据和抽水蓄能机组的发电支撑状态,进一步调节所对应时段新能源纳入系统备用的最佳比例系数,将新能源合理地纳入系统备用。算例结果验证所提方法能够有效提升含高比例新能源电力系统新能源消纳能力,减少新能源弃用。 展开更多
关键词 新能源 电力系统备用 抽水蓄能 K-均值聚类 风险约束
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部