期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Integrated transmission and generation planning model in a leregulated environment 被引量:2
1
作者 Enrique B. CEDENO Sant ARORA 《Frontiers in Energy》 SCIE CSCD 2013年第2期182-190,共9页
After the deregulation of the Power Sector in the U.S., planning for generation and transmission capacities is decentralized. There is, however, still need for the long term integrated planning of generation and trans... After the deregulation of the Power Sector in the U.S., planning for generation and transmission capacities is decentralized. There is, however, still need for the long term integrated planning of generation and transmission capacities at the macro level, since these two sectors must operate in a coordinated manner. This paper presents a model for integrating generation and transmission expansion planning to identify an indicative expansion plan for the total sector at the macro level. The argument for an integrated model is supported using evidence from integrated planning efforts in real life systems. The application of the proposed model is illustrated using an example that requires expansion of generation and transmission capacities over three regions in a deregulated power system. The example considers that addition of generating capacity should come from renewable sources. The test results show the potential cost saving from integrated planning. 展开更多
关键词 integrated planning indicative plans powergeneration TRANSMISSION DEREGULATION
原文传递
Analysis and control of wind-driven self-excited induction generators connected to the grid through power converters 被引量:1
2
作者 S. Senthil KUMAt N. KUMARESAN N. Ammasai GOUNDEN Namani RAKESH 《Frontiers in Energy》 SCIE CSCD 2012年第4期403-412,共10页
The analysis of the wind-driven self-excited induction generators (SEIGs) connected to the grid through power converters has been developed in this paper. For this analysis, a method of representing the grid power a... The analysis of the wind-driven self-excited induction generators (SEIGs) connected to the grid through power converters has been developed in this paper. For this analysis, a method of representing the grid power as equivalent load resistance in the steady-state equivalent circuit of SEIG has been formulated. The technique of genetic algorithm (GA) has been adopted for making the analysis of the proposed system simple and straightfor- ward. The control of SEIG is attempted by connecting an uncontrolled diode bridge rectifier (DBR) and a line commutated inverter (LCI) between the generator term- inals and three-phase utility grid. A simple control technique for maximum power point tracking (MPPT) in wind energy conversion systems (WECS), in which the firing angle of the LCI alone needs to be controlled by sensing the rotor speed of the generator has been proposed. The effectiveness of the proposed method of MPPT and method of analysis of this wind-driven SEIG-converter system connected to the grid through power converters has been demonstrated by experiments and simulation. These experimental and simulated results confirm the usefulness and successful working of the proposed system and its analysis. 展开更多
关键词 self-excited induction generator (SEIG) renewable power generation power converters maximumpower point tracking (MPPT) steady state analysis powergeneration systems
原文传递
Using crosslinked polyvinyl alcohol polymer membrane as a separator in the microbial fuel cell
3
作者 Yanping HOU Kaiming LI +4 位作者 Haiping LUO Guangli LIU Renduo ZHANG Bangyu QIN Shanshan CHEN 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2014年第1期137-143,共7页
Separator between anode and cathode is an essential part of the microbial fuel cell (MFC) and its property could significantly influence the system perfor- mance. In this study we used polyvinyl alcohol (PVA) poly... Separator between anode and cathode is an essential part of the microbial fuel cell (MFC) and its property could significantly influence the system perfor- mance. In this study we used polyvinyl alcohol (PVA) polymer membrane crosslinked with sulfosuccinic acid (SSA) as a new separator for the MFC. The highest power density of 7594-4 mW-m-2 was obtained when MFC using the PVA membrane crosslinked with 15% of SSA due to its desirable proton conductivity (5.16 x 10-2 S.cml). The power density significantly increased to 11064- 30 mW.m-2 with a separator-electrode-assembly config- uration, which was comparable with glass fiber (11704- 46 mW.m-2). The coulombic efficiencies of the MFCs with crosslinked PVA membranes ranged from 36.3% to 45.7% at a fix external resistance of lO00f2. The crosslinked PVA membrane could be a promising alter- native to separator materials for constructing practical MFC system. 展开更多
关键词 microbial fuel cell crosslinked polyvinylalcohol (PVA) membrane separator material powergeneration coulombic efficiency
原文传递