AIM: To study the impact of rejection at different levels of health care by retrospectively reviewing records of dried blood spot samples received at the molecular laboratory for human immunodeficiency virus(HIV) earl...AIM: To study the impact of rejection at different levels of health care by retrospectively reviewing records of dried blood spot samples received at the molecular laboratory for human immunodeficiency virus(HIV) early infant diagnosis(EID) between January 2008 and December 2012.METHODS: The specimen rejection rate, reasons for rejection and the impact of rejection at different levels of health care was examined. The extracted data were cleaned and checked for consistency and then deduplicated using the unique patient and clinic identifiers. The cleaned data were ciphered and exported to SPSS version 19(SPSS 2010 IBM Corp, New York, United States) for statistical analyses.RESULTS: Sample rejection rate of 2.4%(n = 786/32552) and repeat rate of 8.8%(n = 69/786) were established. The mean age of infants presenting for first HIV molecular test among accepted valid samples was 17.83 wk(95%CI: 17.65-18.01) vs 20.30 wk(95%CI: 16.53-24.06) for repeated samples. HIV infection rate was 9.8% vs 15.9% for accepted and repeated samples. Compared to tertiary healthcare clinics, secondary and primary clinics had twofold and three-fold higher likelihood of sample rejection, respectively(P < 0.05). We observed a significant increase in sample rejection rate with increasing number of EID clinics(r = 0.893, P = 0.041). The major reasons for rejection were improper sample collection(26.3%), improper labeling(16.4%) and insufficient blood(14.8%). CONCLUSION: Programs should monitor pre-analytical variables and incorporate continuous quality improvement interventions to reduce errors associated with sample rejection and improve patient retention.展开更多
Abstract: The pre and post analytical phase in a testing cycle contributes up to 93% of total laboratory errors. However, pre-analytical phase is primarily responsible for errors. Hence, it is of precise importance f...Abstract: The pre and post analytical phase in a testing cycle contributes up to 93% of total laboratory errors. However, pre-analytical phase is primarily responsible for errors. Hence, it is of precise importance for the laboratory to study error occurrence rates during the testing cycle and implement a quality improvement plan to release an accurate result. The present study was conducted during the period Jan-Nov 2014 in the Central Clinical Lab in Osmaniye State Hospital, Turkey. During period of 11 months, 626897 samples were monitored for major preanalytical problems at the receiving counter of the Central Clinical Laboratory. Among all preanalytic laboratory errors, 35.4% of the errors were associated with clotted sample, 25.5% errors with inadequate sample, and 25.3% errors with hemolysed sample in the laboratory. Assessment considering the departments showed that emergency unit had the highest error rates (hemolysis: 52.5%, lipemic: 42.9%, damaged: 34.6%, clotted: 34.2%, inadequate: 26.8%, wrong material: 17.6%, wrong barcode: 16.7%). There was significant difference among the departments in terms of preanalytic errors (p 〈 0.001). Based on these observations, major preanalytic errors are of great concern and needs corrective approach via proper educational programs to related personals. If this area is ignored, that can lead to negative patient outcome. However, a better specimen quality and patient satisfaction are achieved with the high quality personal-based education regarding pre-analytical errors.展开更多
Measurement of urinary β2M (beta 2-microglobulin) is a sensitive and reliable assay for detecting tubular injury, renal toxicity, lymphomas, leukemia, or myeloma. Some chemical substrates may increase the level of ...Measurement of urinary β2M (beta 2-microglobulin) is a sensitive and reliable assay for detecting tubular injury, renal toxicity, lymphomas, leukemia, or myeloma. Some chemical substrates may increase the level of β2M in-vivo. Elevated β2M level in urine is unusual because it rapidly degrades when pH is below 6. The level of β2M in the bladder can also be used as a marker to assess renal tubular maturation in neonates. β2M in the bladder could be a result of fetal megacystis, which is an abnormally enlarged bladder appearing after 10 weeks of gestation, when the fetus begins to produce urine. Identification of the pregnant women instead of the fetus is a common pre-analytical error with samples sent from the gynecology clinic to the laboratory. Here we present the case of a 24-year-old pregnant woman whose urine analysis results indicated excessively high β2M level in the urine. The present study could improve the understanding of urinary β2M analysis, laboratory errors, and the interpretation of test results.展开更多
Clinical and forensic toxicology are critically involved in the acquisition of basic skills to correctly suspect intoxication,collect biological and non-biological materials for toxicological analysis,comprehend the c...Clinical and forensic toxicology are critically involved in the acquisition of basic skills to correctly suspect intoxication,collect biological and non-biological materials for toxicological analysis,comprehend the complexities inherent to laboratory activity,and understand the fundamentals of toxicokinetics and toxicodynamics that underlie the interpretation of results.This works presents a pedagogical innovation proposal for the teaching of clinical and forensic toxicology based on a compilation of more than 3000 cases where the image was fulcra for suspicion.The experience in this article follows the model practiced in bachelors,masters,and PhD degrees,as well as in other continuing training courses,where we are teaching toxicology for more than 15 years.All these levels of education are considered fundamental to the sound development of this science.This approach aims also to offer strength to the intervention of the true toxicologist in all the toxicological phases,besides the classic analytical chemistry.Indeed,it is impossible to provide effective clinical and forensic toxicological interpretations without a proper and broad education,and not thinking exclusively in terms of laboratory techniques.In the future,it will be interesting to evaluate knowledge retention and to propose a database of videos of signs related to intoxications.展开更多
基金Supported by The President’s Emergency Plan for AIDS Relief through cooperative agreement(5U2GGH000925-03)from HHS/Centers for Disease Control and Prevention(CDC),Global AIDS Program.The findings and conclusions in this report are those of the author(s)and do not necessarily represent the official position of the Centers for Disease Control and Prevention
文摘AIM: To study the impact of rejection at different levels of health care by retrospectively reviewing records of dried blood spot samples received at the molecular laboratory for human immunodeficiency virus(HIV) early infant diagnosis(EID) between January 2008 and December 2012.METHODS: The specimen rejection rate, reasons for rejection and the impact of rejection at different levels of health care was examined. The extracted data were cleaned and checked for consistency and then deduplicated using the unique patient and clinic identifiers. The cleaned data were ciphered and exported to SPSS version 19(SPSS 2010 IBM Corp, New York, United States) for statistical analyses.RESULTS: Sample rejection rate of 2.4%(n = 786/32552) and repeat rate of 8.8%(n = 69/786) were established. The mean age of infants presenting for first HIV molecular test among accepted valid samples was 17.83 wk(95%CI: 17.65-18.01) vs 20.30 wk(95%CI: 16.53-24.06) for repeated samples. HIV infection rate was 9.8% vs 15.9% for accepted and repeated samples. Compared to tertiary healthcare clinics, secondary and primary clinics had twofold and three-fold higher likelihood of sample rejection, respectively(P < 0.05). We observed a significant increase in sample rejection rate with increasing number of EID clinics(r = 0.893, P = 0.041). The major reasons for rejection were improper sample collection(26.3%), improper labeling(16.4%) and insufficient blood(14.8%). CONCLUSION: Programs should monitor pre-analytical variables and incorporate continuous quality improvement interventions to reduce errors associated with sample rejection and improve patient retention.
文摘Abstract: The pre and post analytical phase in a testing cycle contributes up to 93% of total laboratory errors. However, pre-analytical phase is primarily responsible for errors. Hence, it is of precise importance for the laboratory to study error occurrence rates during the testing cycle and implement a quality improvement plan to release an accurate result. The present study was conducted during the period Jan-Nov 2014 in the Central Clinical Lab in Osmaniye State Hospital, Turkey. During period of 11 months, 626897 samples were monitored for major preanalytical problems at the receiving counter of the Central Clinical Laboratory. Among all preanalytic laboratory errors, 35.4% of the errors were associated with clotted sample, 25.5% errors with inadequate sample, and 25.3% errors with hemolysed sample in the laboratory. Assessment considering the departments showed that emergency unit had the highest error rates (hemolysis: 52.5%, lipemic: 42.9%, damaged: 34.6%, clotted: 34.2%, inadequate: 26.8%, wrong material: 17.6%, wrong barcode: 16.7%). There was significant difference among the departments in terms of preanalytic errors (p 〈 0.001). Based on these observations, major preanalytic errors are of great concern and needs corrective approach via proper educational programs to related personals. If this area is ignored, that can lead to negative patient outcome. However, a better specimen quality and patient satisfaction are achieved with the high quality personal-based education regarding pre-analytical errors.
文摘Measurement of urinary β2M (beta 2-microglobulin) is a sensitive and reliable assay for detecting tubular injury, renal toxicity, lymphomas, leukemia, or myeloma. Some chemical substrates may increase the level of β2M in-vivo. Elevated β2M level in urine is unusual because it rapidly degrades when pH is below 6. The level of β2M in the bladder can also be used as a marker to assess renal tubular maturation in neonates. β2M in the bladder could be a result of fetal megacystis, which is an abnormally enlarged bladder appearing after 10 weeks of gestation, when the fetus begins to produce urine. Identification of the pregnant women instead of the fetus is a common pre-analytical error with samples sent from the gynecology clinic to the laboratory. Here we present the case of a 24-year-old pregnant woman whose urine analysis results indicated excessively high β2M level in the urine. The present study could improve the understanding of urinary β2M analysis, laboratory errors, and the interpretation of test results.
文摘Clinical and forensic toxicology are critically involved in the acquisition of basic skills to correctly suspect intoxication,collect biological and non-biological materials for toxicological analysis,comprehend the complexities inherent to laboratory activity,and understand the fundamentals of toxicokinetics and toxicodynamics that underlie the interpretation of results.This works presents a pedagogical innovation proposal for the teaching of clinical and forensic toxicology based on a compilation of more than 3000 cases where the image was fulcra for suspicion.The experience in this article follows the model practiced in bachelors,masters,and PhD degrees,as well as in other continuing training courses,where we are teaching toxicology for more than 15 years.All these levels of education are considered fundamental to the sound development of this science.This approach aims also to offer strength to the intervention of the true toxicologist in all the toxicological phases,besides the classic analytical chemistry.Indeed,it is impossible to provide effective clinical and forensic toxicological interpretations without a proper and broad education,and not thinking exclusively in terms of laboratory techniques.In the future,it will be interesting to evaluate knowledge retention and to propose a database of videos of signs related to intoxications.