[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was ...[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was extracted using the wa- ter extraction method, further isolated and purified by DEAE cellulose-52 columns. The obtained tea polysaccharide and four components TPS1, TPS2, TPS3 and TPS, were first derived by 1-phenyl-3-methyl-5-pyrazolone (PMP), and then the PMP derivatives of monosaccharide were analyzed by high performance liquid chromatog- raphy (HPLC). [Result] Pu-erh tea polysaccharide contained eight kinds of monosac- chaddes (mannose, rhamnose, glucuronic acid, galacturonic acid, grucose, galactose, arabinose, fucose), without xylose; so it was the same with TPS1; each of TPS2, TPS3 and TPS4 contained seven monosaccharides, while no fucose. [Conclusion] This method is simplified and rapid, which can be used to determine the monosac- charide composition of Pu-erh tea polysaccharide and monosaccharide content.展开更多
Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new met...Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new method is described for the determination of sparfloxacin in human urine. The linear range is 0.05 mg/L to 4.0 mg/L, the recoveries are 91.5%similar to 95.7% and the RSD is 1.2%similar to4.2%. The results showed that this method is suitable for the determination of sparfloxacin in human urine.展开更多
A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were...A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.展开更多
High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral der...High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.展开更多
A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, trigly...A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, triglycine and glutathione were separated on a reversed-phase C-18 column with methanol-water-triethylamine eluent, derivatization and chromatographic conditions were optimized. The five derivatives were eluted in 28 min with a good reproducibility. Linear range of the calibration graph was 0.08-260 nmol/ml(-1). The relative standard deviations(n=6) are < 5%. Detection limits (signal-to-noise ratio=3) for the five derivatives are 20-40 fmol.展开更多
It is found that in the presence of sulfuric acid carbohydrates condense withurea to afford the condensation products, which emit fluorescence. Under optimum conditions, thefluorescence intensities of system are propo...It is found that in the presence of sulfuric acid carbohydrates condense withurea to afford the condensation products, which emit fluorescence. Under optimum conditions, thefluorescence intensities of system are proportional to the concentrations of carbohydrates. Based onthis linear relationship, quantitative determination of kinds of carbohydrates has been made. Amongall the carbohydrates tested, the sensitivity of α-rhamnose is the highest and its limits ofdetection reaches 3. 5 * 10^(-8) mol/L. So α-rhamnose can be selectively determined in the presenceof other carbohydrates. A interaction mechanism is also discussed.展开更多
基金Supported by National Key Technologies R & D Program(2007BAD58B03)~~
文摘[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was extracted using the wa- ter extraction method, further isolated and purified by DEAE cellulose-52 columns. The obtained tea polysaccharide and four components TPS1, TPS2, TPS3 and TPS, were first derived by 1-phenyl-3-methyl-5-pyrazolone (PMP), and then the PMP derivatives of monosaccharide were analyzed by high performance liquid chromatog- raphy (HPLC). [Result] Pu-erh tea polysaccharide contained eight kinds of monosac- chaddes (mannose, rhamnose, glucuronic acid, galacturonic acid, grucose, galactose, arabinose, fucose), without xylose; so it was the same with TPS1; each of TPS2, TPS3 and TPS4 contained seven monosaccharides, while no fucose. [Conclusion] This method is simplified and rapid, which can be used to determine the monosac- charide composition of Pu-erh tea polysaccharide and monosaccharide content.
文摘Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new method is described for the determination of sparfloxacin in human urine. The linear range is 0.05 mg/L to 4.0 mg/L, the recoveries are 91.5%similar to 95.7% and the RSD is 1.2%similar to4.2%. The results showed that this method is suitable for the determination of sparfloxacin in human urine.
基金Supported by Open Project of the Key Laboratory of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base(201603)Basic Research Project of Application of Suzhou City(SNG201622)
文摘A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.
文摘High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.
文摘A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, triglycine and glutathione were separated on a reversed-phase C-18 column with methanol-water-triethylamine eluent, derivatization and chromatographic conditions were optimized. The five derivatives were eluted in 28 min with a good reproducibility. Linear range of the calibration graph was 0.08-260 nmol/ml(-1). The relative standard deviations(n=6) are < 5%. Detection limits (signal-to-noise ratio=3) for the five derivatives are 20-40 fmol.
基金theNationalNaturalScienceFoundationsofChina (No .2 9875 0 15 ),theNaturalScienceFoundationofShandongProvince (No .Z97B0 10 0 2 ),andtheVisitingScholarFoundationofKeyLaboratoryinShandongUniversity
文摘It is found that in the presence of sulfuric acid carbohydrates condense withurea to afford the condensation products, which emit fluorescence. Under optimum conditions, thefluorescence intensities of system are proportional to the concentrations of carbohydrates. Based onthis linear relationship, quantitative determination of kinds of carbohydrates has been made. Amongall the carbohydrates tested, the sensitivity of α-rhamnose is the highest and its limits ofdetection reaches 3. 5 * 10^(-8) mol/L. So α-rhamnose can be selectively determined in the presenceof other carbohydrates. A interaction mechanism is also discussed.