In the present study, the ice slurry refrigeration system with pre-cooling heat exchanger (ISSH) is studied experimentally to achieve the system performance, ice crystal formation time and the temperature of ice cryst...In the present study, the ice slurry refrigeration system with pre-cooling heat exchanger (ISSH) is studied experimentally to achieve the system performance, ice crystal formation time and the temperature of ice crystal formation. The operating parameters considered in this paper include the concentration of salt solution, suction pressure, discharge pressure and Energy Efficiency Ratio (EER). The result shows that the temperature of critical time of ice crystal formation decreases with the increasing concentration of salt solution and that the ice crystal formation time increases with the increasing concentration of salt solution. In the same concentration of salt solution, the ice crystal formation temperature of ISSH is lower than that of basic ice slurry refrigeration system (BISS), and the ice crystal formation time of ISSH is shorter than that of BISS. On the whole, the EER of ice slurry refrigeration system with pre-cooling heat exchanger is higher than that of basic ice slurry refrigeration system.展开更多
Purpose: The purpose of this study was to examine the effects of pre-cooling and fluid replacement with either crushed ice or cold water.Methods: On 2 separate occasions, in a counterbalanced order, 9 recreationally-t...Purpose: The purpose of this study was to examine the effects of pre-cooling and fluid replacement with either crushed ice or cold water.Methods: On 2 separate occasions, in a counterbalanced order, 9 recreationally-trained males ingested 1.25 g/kg(80–100 g) of either crushed ice(0.5℃)or cold water(4℃) every 5 min for 30 min before exercise. They also ingested 2.0 g/kg(130–160 g) of the same treatment drink at 15 min, 30 min, and45 min after the commencement of cycling to exhaustion at 60%VO_(2max) until voluntary exhaustion in a hot environment(35℃ and 30% relative humidity).Results: The cycling time to exhaustion in the crushed ice trial(50.0 ± 12.2 min) was longer than the cold water trial(42.2 ± 10.1 min; p = 0.02).Although the rectal temperature fell by 0.37℃± 0.03℃(p = 0.01) at the end of the resting period after the crushed ice ingestion, the rates of rise in rectal temperature during the exercise period were not significantly different between these 2 conditions(crushed ice: 0.23℃± 0.07℃, 5 min;cold water: 0.22℃± 0.07℃, 5 min; p = 0.94).Conclusion: Crushed ice ingestion before and during exercise in a hot environment may be a preferred and effective approach for minimizing thermal strain, and for improving endurance performance as compared with cold water ingestion.展开更多
This research is aimed to develop a consumer demanding side response model to assist electricity consumers to mitigate peak demands during the peak season. The main contribution of this research is showing that consum...This research is aimed to develop a consumer demanding side response model to assist electricity consumers to mitigate peak demands during the peak season. The main contribution of this research is showing that consumers can mitigate peak demands by optimizing energy costs of an air conditioner(AC) when a spike happens. It may only occur in a one and a half hours spike during the peak season. This model also investigates how AC applies the pre-cooling method when there is a substantial risk of a price spike. The results indicate that the potential benefit of the model is achieving energy savings for consumers and aggregators,also reducing electricity bills for the consumers. The model is tested with selected characteristics of the room,and based on the standard room in a residential house in Makassar, a city of Indonesia.展开更多
Cryogenic ground supporting equipment (CGSE) developed for international cooperation scientific experimental item AMS-02 is the ground supporting and cooling system, which will complete the cooling process of the supe...Cryogenic ground supporting equipment (CGSE) developed for international cooperation scientific experimental item AMS-02 is the ground supporting and cooling system, which will complete the cooling process of the superconductor of AMS-02 from ambient temperature to 1.8 K. Obtaining 1.8 K He Ⅱ by vacuum-pumping is discussed in detail and compared with the other three schemes. The results show that the scheme of vacuum-pumping not only could meet the requirement of the project much better but also has higher reliability compared with other schemes. To select the vacuum pump, the energy conservation model is presented according to the experimental system of CGSE. Therefore, the pumping speed is also determined.展开更多
Building air conditioning systems(ACs)can contribute to the stable operation of power grids by participating in peak load shaving programs,but the participants need a fast and accurate zone temperature prediction mode...Building air conditioning systems(ACs)can contribute to the stable operation of power grids by participating in peak load shaving programs,but the participants need a fast and accurate zone temperature prediction model,e.g.,the detailed room thermal-resistance(RC)model,to improve peak shaving effect and avoid obvious thermal discomfort.However,when applying the detailed room RC model to multi-zone buildings,conventional studies mostly consider the heat transfer among neighboring rooms,which contributes little to the prediction accuracy improvement,but leads to complicated model structure and heavy computation.Thus,a distributed RC model is developed for multi-zone buildings in this study.Compared to conventional models,the proposed model considers the total heat transfer between the building and the air,and ignores the heat transfer among indoor air in neighboring rooms through internal walls with heavy thermal mass,thereby having comparable temperature prediction accuracy,simpler structure,and stronger robustness.Based on the model,the effectiveness of passive pre-cooling strategies in reducing the air conditioning loads during peak periods is investigated.Results indicate that the thermal insulation performance of opaque building envelope is quite important to the flexibility enhancement of air conditioning loads.With an uninsulated building envelope,passive pre-cooling is useless for the peak load shaving.In comparison,well insulated opaque building envelope enables the building thermal mass to be utilized through passive pre-cooling,which leads to the air conditioning loads during peak periods being further reduced by about 12%.展开更多
Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat...Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat transfer experimental platform,the effect of mass flow rate in both cold and heat sides,as well as the cross-section aspect ratio of the rectangular straight channel,on the heat transfer performance of PCHE was investigated.The results show that the comprehensive heat transfer performance of the rectangular cross-section is better than that of the semicircular cross-section;increasing the aspect ratio can improve the comprehensive heat transfer performance of PCHE,but the strengthening effect diminishes as the aspect ratio increases.Increasing the mass flow rate on both sides not only enhances the pre-cooler's cooling capacity and heat transfer,but also raises the pressure drop.In addition,an improved heat transfer correlation for rectangular cross-section PCHE was proposed,considering the effects of cross-sectional aspect ratio and pseudo-critical temperature is proposed in the range of Re from 3169 to 48474 and Pr from 0.98 to 12.5,the fited results better predict the local Nu and f magnitudes and trends in the pre-cooler under different cooling conditions,outperforming the simulated data and Gnielinski and Blasius correlation.展开更多
To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building...To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building energy consumption,especially in tropical and subtropical areas.A proper way should be employed to reduce the cooling load of fresh air.Radiative sky cooling,which is the process that an object cools itself by emitting thermal radiation to outer space without any energy input,is a cost-effective and eco-friendly technology.In this work,a fresh air pre-cooling system using radiative sky cooling is proposed to reduce fresh air cooling load.The system,consisting of filters,a radiative air-cooling system,an air handling unit(AHU),fans,etc.,is installed on the rooftop of the modeled building.Six cities in low-latitude areas are selected and investigated.Results show that with the radiative air-cooling system installed,annual cooling energy consumption of the modeled building can be reduced by around 10%in most cities.For arid areas,e.g.,Abu Dhabi,the system has even better performance with 19.34%annual cooling energy saving.展开更多
In this study,an experimental system was built to investigate the global performance of an 80-k W zigzag printed circuit heat exchanger(PCHE).It could meet the requirement of the pre-cooler for the supercritical carbo...In this study,an experimental system was built to investigate the global performance of an 80-k W zigzag printed circuit heat exchanger(PCHE).It could meet the requirement of the pre-cooler for the supercritical carbon dioxide(S-CO_(2))Brayton power cycle and the modified effectiveness considering the pinch point is between 61.5%and 79.3%.When the outlet S-CO_(2)temperature is near the pseudo-critical point,the thermo-physical properties have more effects on heat transfer performance compared to flow characteristics.For the local performance,the mass flow rates of both sides have crucial influences on the location where the peak of S-CO_(2)Nusselt number occurs while only the S-CO_(2)flow rate affects the variation of the peak value.In addition,the influence of the radius of curvature on the secondary-flow should not be ignored.In the end,new empirical correlations were proposed considering the drastic variations of the Prandtl number.展开更多
文摘In the present study, the ice slurry refrigeration system with pre-cooling heat exchanger (ISSH) is studied experimentally to achieve the system performance, ice crystal formation time and the temperature of ice crystal formation. The operating parameters considered in this paper include the concentration of salt solution, suction pressure, discharge pressure and Energy Efficiency Ratio (EER). The result shows that the temperature of critical time of ice crystal formation decreases with the increasing concentration of salt solution and that the ice crystal formation time increases with the increasing concentration of salt solution. In the same concentration of salt solution, the ice crystal formation temperature of ISSH is lower than that of basic ice slurry refrigeration system (BISS), and the ice crystal formation time of ISSH is shorter than that of BISS. On the whole, the EER of ice slurry refrigeration system with pre-cooling heat exchanger is higher than that of basic ice slurry refrigeration system.
文摘Purpose: The purpose of this study was to examine the effects of pre-cooling and fluid replacement with either crushed ice or cold water.Methods: On 2 separate occasions, in a counterbalanced order, 9 recreationally-trained males ingested 1.25 g/kg(80–100 g) of either crushed ice(0.5℃)or cold water(4℃) every 5 min for 30 min before exercise. They also ingested 2.0 g/kg(130–160 g) of the same treatment drink at 15 min, 30 min, and45 min after the commencement of cycling to exhaustion at 60%VO_(2max) until voluntary exhaustion in a hot environment(35℃ and 30% relative humidity).Results: The cycling time to exhaustion in the crushed ice trial(50.0 ± 12.2 min) was longer than the cold water trial(42.2 ± 10.1 min; p = 0.02).Although the rectal temperature fell by 0.37℃± 0.03℃(p = 0.01) at the end of the resting period after the crushed ice ingestion, the rates of rise in rectal temperature during the exercise period were not significantly different between these 2 conditions(crushed ice: 0.23℃± 0.07℃, 5 min;cold water: 0.22℃± 0.07℃, 5 min; p = 0.94).Conclusion: Crushed ice ingestion before and during exercise in a hot environment may be a preferred and effective approach for minimizing thermal strain, and for improving endurance performance as compared with cold water ingestion.
基金supported by Ministy of Research,Technology and Higher Education of the Republic of Indonesia
文摘This research is aimed to develop a consumer demanding side response model to assist electricity consumers to mitigate peak demands during the peak season. The main contribution of this research is showing that consumers can mitigate peak demands by optimizing energy costs of an air conditioner(AC) when a spike happens. It may only occur in a one and a half hours spike during the peak season. This model also investigates how AC applies the pre-cooling method when there is a substantial risk of a price spike. The results indicate that the potential benefit of the model is achieving energy savings for consumers and aggregators,also reducing electricity bills for the consumers. The model is tested with selected characteristics of the room,and based on the standard room in a residential house in Makassar, a city of Indonesia.
基金The National Natural Science Foundation of China ( No. 50476022 )Ministries and Commissions of Science and Technology of Shanghai Government (No. 03DZ 14014)
文摘Cryogenic ground supporting equipment (CGSE) developed for international cooperation scientific experimental item AMS-02 is the ground supporting and cooling system, which will complete the cooling process of the superconductor of AMS-02 from ambient temperature to 1.8 K. Obtaining 1.8 K He Ⅱ by vacuum-pumping is discussed in detail and compared with the other three schemes. The results show that the scheme of vacuum-pumping not only could meet the requirement of the project much better but also has higher reliability compared with other schemes. To select the vacuum pump, the energy conservation model is presented according to the experimental system of CGSE. Therefore, the pumping speed is also determined.
基金supported by the National Natural Science Foundation of China(Grant No.52078096)the Natural Science Foundation Joint Fund of Liaoning Province(Grant No.2023-MSBA-023)+1 种基金2023 Dalian University of Technology-Cardiff University Cooperation and Exchange Foundation Project,2023 International Exchange Foundation Project of“Co-Creation of Excellence Program”from Dalian University of Technology(Grant No.DUTIO-ZG-202307)the Key Project of DUT for International Students Studying and Researching in China:Innovation and Practice of Talent Cultivation Model in the Field of Smart Buildings for the“Belt and Road"Initiative(Grant No.1103-82120001).
文摘Building air conditioning systems(ACs)can contribute to the stable operation of power grids by participating in peak load shaving programs,but the participants need a fast and accurate zone temperature prediction model,e.g.,the detailed room thermal-resistance(RC)model,to improve peak shaving effect and avoid obvious thermal discomfort.However,when applying the detailed room RC model to multi-zone buildings,conventional studies mostly consider the heat transfer among neighboring rooms,which contributes little to the prediction accuracy improvement,but leads to complicated model structure and heavy computation.Thus,a distributed RC model is developed for multi-zone buildings in this study.Compared to conventional models,the proposed model considers the total heat transfer between the building and the air,and ignores the heat transfer among indoor air in neighboring rooms through internal walls with heavy thermal mass,thereby having comparable temperature prediction accuracy,simpler structure,and stronger robustness.Based on the model,the effectiveness of passive pre-cooling strategies in reducing the air conditioning loads during peak periods is investigated.Results indicate that the thermal insulation performance of opaque building envelope is quite important to the flexibility enhancement of air conditioning loads.With an uninsulated building envelope,passive pre-cooling is useless for the peak load shaving.In comparison,well insulated opaque building envelope enables the building thermal mass to be utilized through passive pre-cooling,which leads to the air conditioning loads during peak periods being further reduced by about 12%.
基金supported by the National Natural Science Foundation of China(52276150).
文摘Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat transfer experimental platform,the effect of mass flow rate in both cold and heat sides,as well as the cross-section aspect ratio of the rectangular straight channel,on the heat transfer performance of PCHE was investigated.The results show that the comprehensive heat transfer performance of the rectangular cross-section is better than that of the semicircular cross-section;increasing the aspect ratio can improve the comprehensive heat transfer performance of PCHE,but the strengthening effect diminishes as the aspect ratio increases.Increasing the mass flow rate on both sides not only enhances the pre-cooler's cooling capacity and heat transfer,but also raises the pressure drop.In addition,an improved heat transfer correlation for rectangular cross-section PCHE was proposed,considering the effects of cross-sectional aspect ratio and pseudo-critical temperature is proposed in the range of Re from 3169 to 48474 and Pr from 0.98 to 12.5,the fited results better predict the local Nu and f magnitudes and trends in the pre-cooler under different cooling conditions,outperforming the simulated data and Gnielinski and Blasius correlation.
基金support from the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20200373).
文摘To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building energy consumption,especially in tropical and subtropical areas.A proper way should be employed to reduce the cooling load of fresh air.Radiative sky cooling,which is the process that an object cools itself by emitting thermal radiation to outer space without any energy input,is a cost-effective and eco-friendly technology.In this work,a fresh air pre-cooling system using radiative sky cooling is proposed to reduce fresh air cooling load.The system,consisting of filters,a radiative air-cooling system,an air handling unit(AHU),fans,etc.,is installed on the rooftop of the modeled building.Six cities in low-latitude areas are selected and investigated.Results show that with the radiative air-cooling system installed,annual cooling energy consumption of the modeled building can be reduced by around 10%in most cities.For arid areas,e.g.,Abu Dhabi,the system has even better performance with 19.34%annual cooling energy saving.
基金supported by the National Natural Science Foundation of China(No.51606191)the National Key Research and Development Program-China(2017YFB0601803)Key deployment project of Chinese Academy of Sciences(Y7220112H1)。
文摘In this study,an experimental system was built to investigate the global performance of an 80-k W zigzag printed circuit heat exchanger(PCHE).It could meet the requirement of the pre-cooler for the supercritical carbon dioxide(S-CO_(2))Brayton power cycle and the modified effectiveness considering the pinch point is between 61.5%and 79.3%.When the outlet S-CO_(2)temperature is near the pseudo-critical point,the thermo-physical properties have more effects on heat transfer performance compared to flow characteristics.For the local performance,the mass flow rates of both sides have crucial influences on the location where the peak of S-CO_(2)Nusselt number occurs while only the S-CO_(2)flow rate affects the variation of the peak value.In addition,the influence of the radius of curvature on the secondary-flow should not be ignored.In the end,new empirical correlations were proposed considering the drastic variations of the Prandtl number.