In this paper,since the Avalanche Photo Diode(APD)for Light-to-Voltage LTV conversion uses a high voltage in the operating range unlike other Photo Diodes(PD),the quenching resistor must be connected in series to prev...In this paper,since the Avalanche Photo Diode(APD)for Light-to-Voltage LTV conversion uses a high voltage in the operating range unlike other Photo Diodes(PD),the quenching resistor must be connected in series to prevent overcurrent when using the Transimpedance Amplifier(TIA).In such a case,quenching resistance may affect the transfer function of the TIA circuit,resulting in serious stability.Therefore,in this paper,by analyzing the effect of APD quenching resistance on the voltage and current loop transfer function of TIA,we proposed a loop analysis and a method for determining the quenching resistance value to improve stability.A TIA circuit with quenching resistance was designed by the proposed method and its operational stability was verified through simulation and chip fabrication.展开更多
This report addresses the issues concerning the analysis of an electric circuit composed of multiple resistors configured in a 3-Dimension structure. Noting, all the standard textbooks of physics and engineering irres...This report addresses the issues concerning the analysis of an electric circuit composed of multiple resistors configured in a 3-Dimension structure. Noting, all the standard textbooks of physics and engineering irrespective of the used components are circuits assembled in two dimensions. Here, by deviating from the “norm” we consider a case where the resistors are arranged in a 3D structure;e.g., a cube. Although, independent of the dimension of the design the same physics principles apply, transitioning from a 2D to a 3D makes the corresponding analysis considerably challenging. In general, with no exception, depending on the used components the analysis faces with solving a set of either algebraic or differential-algebraic equations. Practically, this interfaces with a Computer Algebra System (CAS). The main objective is symbolically to identify the current distributions and the equivalent resistor (s) of cubically assembled resistors.展开更多
Purpose–This study aims to improve the availability of regenerative braking for urban metro vehicles by introducing a sensorless operational temperature estimation method for the braking resistor(BR)onboard the vehic...Purpose–This study aims to improve the availability of regenerative braking for urban metro vehicles by introducing a sensorless operational temperature estimation method for the braking resistor(BR)onboard the vehicle,which overcomes the vulnerability of having conventional temperature sensor.Design/methodology/approach–In this study,the energy model based sensorless estimation method is developed.By analyzing the structure and the convection dissipation process of the BR onboard the vehicle,the energy-based operational temperature model of the BR and its cooling domain is established.By adopting Newton’s law of cooling and the law of conservation of energy,the energy and temperature dynamic of the BR can be stated.To minimize the use of all kinds of sensors(including both thermal and electrical),a novel regenerative braking power calculation method is proposed,which involves only the voltage of DC traction network and the duty cycle of the chopping circuit;both of them are available for the traction control unit(TCU)of the vehicle.By utilizing a real-time iterative calculation and updating the parameter of the energy model,the operational temperature of the BR can be obtained and monitored in a sensorless manner.Findings–In this study,a sensorless estimation/monitoring method of the operational temperature of BR is proposed.The results show that it is possible to utilize the existing electrical sensors that is mandatory for the traction unit’s operation to estimate the operational temperature of BR,instead of adding dedicated thermal sensors.The results also validate the effectiveness of the proposal is acceptable for the engineering practical.Originality/value–The proposal of this study provides novel concepts for the sensorless operational temperature monitoring of BR onboard rolling stocks.The proposed method only involves quasi-global electrical variable and the internal control signal within the TCU.展开更多
Two cubical 3D electric circuits with single and double capacitors and twelve ohmic resistors are considered. The resistors are the sides of the cube. The circuit is fed with a single internal emf. The charge on the c...Two cubical 3D electric circuits with single and double capacitors and twelve ohmic resistors are considered. The resistors are the sides of the cube. The circuit is fed with a single internal emf. The charge on the capacitor(s) and the current distributions of all twelve sides of the circuit(s) vs. time are evaluated. The analysis requires solving twelve differential-algebraic intertwined symbolic equations. This is accomplished by applying a Computer Algebra System (CAS), specifically Mathematica. The needed codes are included. For a set of values assigned to the elements, the numeric results are depicted.展开更多
断路器的合闸电阻能够有效抑制合闸涌流以及操作过电压,对电网的稳定运行起着重要作用,合闸电阻一旦出现故障,无法正确投入或退出,将会造成巨大的设备和安全事故。由于1100 k V GIS断路器为多断口结构,断口间的配合时序偏差以及各触头...断路器的合闸电阻能够有效抑制合闸涌流以及操作过电压,对电网的稳定运行起着重要作用,合闸电阻一旦出现故障,无法正确投入或退出,将会造成巨大的设备和安全事故。由于1100 k V GIS断路器为多断口结构,断口间的配合时序偏差以及各触头弹跳因素的干扰,经常导致合闸电阻特性无法测量,或者测试结果误差较大。针对一起1100 kV GIS断路器合闸电阻预投入时间及阻值无法检测事件展开研究,分析其结构与测试原理,通过提高测试频率获取完整测试波形,推断得出合闸电阻的预投入时间及其阻值无法检测的原因是其中一侧的合闸电阻断口失效。解体检查,发现该断路器其中一侧合闸电阻动触头因固定螺栓断裂而导致该侧动触头脱落,验证了电阻断口失效导致动作特性无法检测的推断。最后从制作工艺、试验项目、试验仪器、检测手段等方面提出相应的建议及改进措施,为同类型设备的工艺管控和故障诊断提供参考。展开更多
文摘In this paper,since the Avalanche Photo Diode(APD)for Light-to-Voltage LTV conversion uses a high voltage in the operating range unlike other Photo Diodes(PD),the quenching resistor must be connected in series to prevent overcurrent when using the Transimpedance Amplifier(TIA).In such a case,quenching resistance may affect the transfer function of the TIA circuit,resulting in serious stability.Therefore,in this paper,by analyzing the effect of APD quenching resistance on the voltage and current loop transfer function of TIA,we proposed a loop analysis and a method for determining the quenching resistance value to improve stability.A TIA circuit with quenching resistance was designed by the proposed method and its operational stability was verified through simulation and chip fabrication.
文摘This report addresses the issues concerning the analysis of an electric circuit composed of multiple resistors configured in a 3-Dimension structure. Noting, all the standard textbooks of physics and engineering irrespective of the used components are circuits assembled in two dimensions. Here, by deviating from the “norm” we consider a case where the resistors are arranged in a 3D structure;e.g., a cube. Although, independent of the dimension of the design the same physics principles apply, transitioning from a 2D to a 3D makes the corresponding analysis considerably challenging. In general, with no exception, depending on the used components the analysis faces with solving a set of either algebraic or differential-algebraic equations. Practically, this interfaces with a Computer Algebra System (CAS). The main objective is symbolically to identify the current distributions and the equivalent resistor (s) of cubically assembled resistors.
基金supported by the Fund of China Academy of Railway Sciences Corporation Limited(2022YJ230)the Scientific Research Projects of China Association of Metros(CAMET-KY-2022039).
文摘Purpose–This study aims to improve the availability of regenerative braking for urban metro vehicles by introducing a sensorless operational temperature estimation method for the braking resistor(BR)onboard the vehicle,which overcomes the vulnerability of having conventional temperature sensor.Design/methodology/approach–In this study,the energy model based sensorless estimation method is developed.By analyzing the structure and the convection dissipation process of the BR onboard the vehicle,the energy-based operational temperature model of the BR and its cooling domain is established.By adopting Newton’s law of cooling and the law of conservation of energy,the energy and temperature dynamic of the BR can be stated.To minimize the use of all kinds of sensors(including both thermal and electrical),a novel regenerative braking power calculation method is proposed,which involves only the voltage of DC traction network and the duty cycle of the chopping circuit;both of them are available for the traction control unit(TCU)of the vehicle.By utilizing a real-time iterative calculation and updating the parameter of the energy model,the operational temperature of the BR can be obtained and monitored in a sensorless manner.Findings–In this study,a sensorless estimation/monitoring method of the operational temperature of BR is proposed.The results show that it is possible to utilize the existing electrical sensors that is mandatory for the traction unit’s operation to estimate the operational temperature of BR,instead of adding dedicated thermal sensors.The results also validate the effectiveness of the proposal is acceptable for the engineering practical.Originality/value–The proposal of this study provides novel concepts for the sensorless operational temperature monitoring of BR onboard rolling stocks.The proposed method only involves quasi-global electrical variable and the internal control signal within the TCU.
文摘Two cubical 3D electric circuits with single and double capacitors and twelve ohmic resistors are considered. The resistors are the sides of the cube. The circuit is fed with a single internal emf. The charge on the capacitor(s) and the current distributions of all twelve sides of the circuit(s) vs. time are evaluated. The analysis requires solving twelve differential-algebraic intertwined symbolic equations. This is accomplished by applying a Computer Algebra System (CAS), specifically Mathematica. The needed codes are included. For a set of values assigned to the elements, the numeric results are depicted.
文摘断路器的合闸电阻能够有效抑制合闸涌流以及操作过电压,对电网的稳定运行起着重要作用,合闸电阻一旦出现故障,无法正确投入或退出,将会造成巨大的设备和安全事故。由于1100 k V GIS断路器为多断口结构,断口间的配合时序偏差以及各触头弹跳因素的干扰,经常导致合闸电阻特性无法测量,或者测试结果误差较大。针对一起1100 kV GIS断路器合闸电阻预投入时间及阻值无法检测事件展开研究,分析其结构与测试原理,通过提高测试频率获取完整测试波形,推断得出合闸电阻的预投入时间及其阻值无法检测的原因是其中一侧的合闸电阻断口失效。解体检查,发现该断路器其中一侧合闸电阻动触头因固定螺栓断裂而导致该侧动触头脱落,验证了电阻断口失效导致动作特性无法检测的推断。最后从制作工艺、试验项目、试验仪器、检测手段等方面提出相应的建议及改进措施,为同类型设备的工艺管控和故障诊断提供参考。