期刊文献+
共找到4,350篇文章
< 1 2 218 >
每页显示 20 50 100
Resilience-incorporated seismic risk assessment of precast concrete frames with“dry”connections
1
作者 Wu Chenhao Tang Yuchuan +1 位作者 Cao Xuyang Wu Gang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期403-425,共23页
A resilience-incorporated risk assessment framework is proposed and demonstrated in this study to manifest the advantageous seismic resilience of precast concrete frame(PCF)structures with“dry”connections in terms o... A resilience-incorporated risk assessment framework is proposed and demonstrated in this study to manifest the advantageous seismic resilience of precast concrete frame(PCF)structures with“dry”connections in terms of their low damage and rapid recovery.The framework integrates various uncertainties in the seismic hazard,fragility,capacity,demand,loss functions,and post-earthquake recovery.In this study,the PCF structures are distinguished from ordinary reinforced concrete frame(RCF)structures by characterizing multiple limit states for the PCF based on its unique damage mechanisms.Accordingly,probabilistic story-wise pushover analyses are performed to yield story-wise capacities for the predefined limit states.In the seismic resilience analysis,a step-wise recovery model is proposed to idealize the functionality recovery process,with separate considerations of the repair and non-repair events.The recovery model leverages the economic loss and downtime to delineate the stochastic post-earthquake recovery curves for the resilience loss estimation.As such,contingencies in the probabilistic post-earthquake repairs are incorporated and the empirical judgments on the recovery parameters are largely circumvented.The proposed framework is demonstrated through a comparative study between two“dry”connected PCFs and one RCF designed as alternative structural systems for a prototype building.The results from the risk quantification indicate that the PCFs show reduced loss hazards and lower expected losses relative to the RCF.Particularly,the PCF equipped with energy dissipation devices at the“dry”connections largely reduces the expected economic loss,downtime,and resilience loss by 29%,56%,and 60%,respectively,compared to the RCF. 展开更多
关键词 precast concrete frame non-emulative precast system seismic resilience seismic risk functional recovery
下载PDF
Hysteretic behavior of post-tensioned precast segmental CFT double-column piers
2
作者 Li Xian Zhang Zilin +2 位作者 Zhou Tao Xiao Yu Sun Yushun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期747-762,共16页
Considering the desirable behavior of concrete filled steel tube(CFT)columns and the complicated behavior of segmental double-column piers under cyclic loads,three post-tensioned precast segmental CFT double-column pi... Considering the desirable behavior of concrete filled steel tube(CFT)columns and the complicated behavior of segmental double-column piers under cyclic loads,three post-tensioned precast segmental CFT double-column pier specimens were tested to extend their application in moderate and high seismicity areas.The effects of the number of CFT segments and the steel endplates as energy dissipaters on the seismic behavior of the piers were evaluated.The experimental results show that the segmental piers exhibited stable hysteretic behavior with small residual displacements under cyclic loads.All the tested specimens achieved a drift ratio no less than 13%without significant damage and strength deterioration due to the desirable behavior of CFT columns.Since the deformation of segmental columns was mainly concentrated at the column-footing interfaces,the increase of the segment numbers for each column had no obvious effects on the loading capacity but reduced the initial stiffness of the specimens.The use of steel endplates improved the bearing capacity,stiffness and energy dissipation of segmental piers,but weakened their self-centering capacity.Fiber models were also proposed to simulate the hysteretic behavior of the tested specimens,and the influences of segment numbers and prestress levels on seismic behavior were further studied. 展开更多
关键词 precast segmental piers cyclic loading test seismic behavior concrete filled tube column rockinganalysis
下载PDF
Development of a new connection for precast concrete walls subjected to cyclic loading 被引量:8
3
作者 Ramin Vaghei Farzad Hejazi +2 位作者 Hafez Taheri Mohd Saleh Jaafar Farah Nora Aznieta Abdul Aziz 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期97-117,共21页
The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures... The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions. 展开更多
关键词 industrial building system precast concrete structure precast wall connection finite element method nonlinear analysis energy dissipation concrete damage plasticity
下载PDF
An evaluation of force-based design vs.direct displacement-based design of jointed precast post-tensioned wall systems 被引量:10
4
作者 M. Ataur Rahman Sri Sritharan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第2期285-296,共12页
The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tension... The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability. 展开更多
关键词 CONCRETE precast unbonded post-tensioning WALL building code performance-based evaluation force-baseddesign direct-displacement based design
下载PDF
Seismic performance of interior precast concrete beam-column connections with T-section steel inserts under cyclic loading 被引量:14
5
作者 Rattapon Ketiyot Chayanon Hansapinyo 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期355-369,共15页
An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/... An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region. 展开更多
关键词 precast concrete beam-column connection cyclic loading
下载PDF
Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular section 被引量:8
6
作者 Bu Zhanyu Guo Jian +2 位作者 Zheng Rongyue Song Jianwei George C.Lee 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期297-312,共16页
In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed ... In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The preeast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for preeast segmental columns with different design parameters. 展开更多
关键词 precast concrete segmental column simplified pushover fiber model
下载PDF
Shake-table testing of a self-centering precast reinforced concrete frame with shear walls 被引量:9
7
作者 Lu Xilin Yang Boya Zhao Bin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期221-233,共13页
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ... The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions. 展开更多
关键词 SELF-CENTERING shake-table test RC frame with shear walls precast unbonded post-tensioning seismicperformance
下载PDF
Experimental seismic behavior of squat shear walls with precast concrete hollow moulds 被引量:3
8
作者 Han Wenlong Zhao Zuozhou +2 位作者 Qian Jiaru Zhang Yingbao Ma Tao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期871-886,共16页
This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Nonc... This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Noncontact lap splices of rebars are used in vertical joints connecting adjacent precast panels for automated prefabrication and easy in situ erection. The seismic behavior of EVE walls was examined through a series of tests on six wall specimens with aspect ratios of 1.0~1.3. Test results showed that EVE wall specimens with inside cast-in situ concrete achieved the desired “strong bending and weak shear” and failed in shear mode. Common main diagonal cracks and brittle shear failure in squat cast-in situ walls were prevented. Inside cast-in situ concrete could signifi cantly improve the shear strength and stiff ness of EVE walls. The details of boundary elements (cast-in situ or prefabricated) and vertical joints (contiguous or spaced) had little eff ect on the global behavior of EVE walls. Noncontact lap splices in vertical joints could enable EVE walls to exhibit stable load-carrying capacity through extensive deformations. Evaluation on design codes revealed that both JGJ 3-2010 and ACI 318-14 provide conservative estimation of shear strength of EVE walls, and EVE walls achieved shear strength reserves comparative to cast-in situ walls. The recommended eff ective stiff ness for cast-in situ walls in ASCE 41-17 appeared to be appropriate for EVE walls. 展开更多
关键词 precast concrete HOLLOW mould low-aspect-ratio NONCONTACT lap splice prefabricated boundary element vertical and horizontal joints seismic behavior
下载PDF
Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls 被引量:3
9
作者 Li Wenfeng Wang Tao +2 位作者 Chen Xi Zhong Xiang Pan Peng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第3期587-597,共11页
A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system s... A retrofitting technology using precast steel reinforced concrete(PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests. 展开更多
关键词 masonry buildings precast SRC panel seismic retrofit pseudo-dynamic test seismic performance
下载PDF
Fuzzy rule based seismic risk assessment of one-story precast industrial buildings 被引量:2
10
作者 Mehmet Palanci 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第3期631-648,共18页
Effi cient tools capable of using uncertain data to produce fast and approximate results are more practical in rapid decision-making applications when compared to conventional methods. From this point of view, this st... Effi cient tools capable of using uncertain data to produce fast and approximate results are more practical in rapid decision-making applications when compared to conventional methods. From this point of view, this study introduces a risk assessment model for one-story precast industrial buildings by fuzzy logic which builds a bridge between uncertainty and precision. The input, output and relations of the fuzzy based risk assessment model (FBRAM) were determined by reference buildings. The Monte Carlo simulation method was used to handle uncertainties associated with the structural characteristics of the reference buildings. Section dimension, longitudinal reinforcement ratio, column height related to building elevation, confi nement ratio and seismic hazard are regarded as input and the plastic demand ratio is considered as the output parameter by the mathematical formulation of strength and deformation capacity of the buildings. The supervised learning method was used to determine the membership function of fuzzy sets. Fuzzy rules of FBRAM were constructed from Monte Carlo simulation by mapping of inputs and output. FBRAM was evaluated by a group of simulated buildings and two existing precast industrial buildings. Comparisons have shown signifi cant agreement with analytical model results in both cases. Consequently, it is anticipated that the proposed model can be used for the seismic risk mitigation of precast buildings. 展开更多
关键词 fuzzy LOGIC supervised learning precast BUILDINGS RISK assessment MONTE Carlo simulation
下载PDF
Seismic performance of precast shear wall-slab connection under cyclic loading: experimental test vs. numerical analysis 被引量:4
11
作者 Arthi S Jaya KP 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第3期739-757,共19页
The structural behaviour of precast shear wall-diaphragm connection was compared with the monolithic connection under seismic loading.The monolithic connection was made by using U-bars connecting shear wall and slab,a... The structural behaviour of precast shear wall-diaphragm connection was compared with the monolithic connection under seismic loading.The monolithic connection was made by using U-bars connecting shear wall and slab,and the precast connection was made by using dowel bars in two steps.Firstly,U-shaped dowel bars from the precast shear wall lower panel and precast slab were connected by the longitudinal reinforcement,and screed concreting was done above the precast slab.Secondly,the shear wall upper panel was connected using the dowel bar protruding from the shear wall lower panel.The gap between the dowel bars and the duct was filled with non-shrink grout.The specimens were subjected to reverse cyclic loading at the ends of the slab.This study also aimed to develop a 3-D numerical model using ABAQUS software.The non-linear properties of concrete were defined by using the concrete damaged plasticity(CDP)model to analyse the response of the structure.The precast dowel connection between the shear wall and slab showed superior performance concerning ductility,strength,stiffness and energy dissipation.The developed finite element model exactly predicted the behaviour of connections as similar to that of experimental testing in the laboratory.The average difference between the results from finite element analysis and experimental testing was less than 20%.The results point to the conclusion that the shear resistance is provided by the dowel bars and the stiffness of the precast specimen is due to the diaphragm action of the precast slab.The damage parameter and the interaction between structural members play a crucial role in the modelling of precast connections. 展开更多
关键词 precast loading STIFFNESS
下载PDF
Seismic performance of precast bridge columns connected with grouted corrugated-metal duct through biaxial quasi-static experiment and modeling 被引量:3
12
作者 Xia Zhanghua Lin Shangshun +2 位作者 He Yongbo Ge Jiping Sun Jinlei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第3期747-770,共24页
In this paper,the seismic behaviors of precast bridge columns connected with grouted corrugated-metal duct(GCMD)were investigated through the biaxial quasi-static experiment and numerical simulation.With a geometric s... In this paper,the seismic behaviors of precast bridge columns connected with grouted corrugated-metal duct(GCMD)were investigated through the biaxial quasi-static experiment and numerical simulation.With a geometric scale ratio of 1:5,five specimens were fabricated,including four precast bridge columns connected with GCMD and one cast-in-place(CIP)bridge column.A finite element analysis model was also established by using OpenSees and was then calibrated by using the experimental results for parameter analysis.The results show the biaxial seismic performance of the precast bridge columns connected with GCMD was similar to the CIP bridge columns regarding ultimate bearing capacity and hysteresis energy,and further,that it could meet the design goal of equivalent performance.The seismic performance of the precast bridge columns connected with GCMD deteriorated more significantly under bi-directional load than under uni-directional load.A proper slenderness ratio(e.g.,7.0-10.0)and longitudinal reinforcement ratio could significantly improve the energy dissipation capacity and deformation capacity of the precast bridge columns,while the axial load ratio and concrete strength had little influence on the above properties.The research results could bring insights to the development of the seismic design of precast bridge columns connected with GCMD. 展开更多
关键词 precast bridge column cast-in-place column grouted corrugated-metal duct connection biaxial quasi-static test seismic performance hysteresis energy
下载PDF
Seismic performance evaluation of a self-centering precast reinforced concrete frame structure 被引量:2
13
作者 Mao Chenxi Wang Zhenying 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第4期943-968,共26页
The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analyt... The seismic performance of a five-story,four-bay,self-centering precast reinforced concrete frame(SC-RCF),which was redesigned using the direct displacement-based design method,was analytically investigated.The analytical model of the overall structure was developed in OpenSees.The multi-spring contact element was adopted to simulate gap open-close behavior at connection interfaces.The limit states of external mild steel dampers and unbonded post-tensioning strands were considered.Static pushover analyses were performed up to the roof drift of 10%.The nonlinear dynamic responses under four groups of ground motions(with different fault distances and site conditions)at six hazard levels(from the service to the very rare earthquake(VRE))were compared.Incremental dynamic analyses were implemented to quantify the structural collapse risk.The results showed that the structural responses of SC-RCF were satisfactory under all levels of earthquakes.The collapse safety of the structure under earthquakes up to VRE1 was adequate,while the structure would collapse to a large extent under VRE2 and VRE3. 展开更多
关键词 self-centering system precast RC frame unbonded post-tensioning incremental dynamic analysis collapse fragility
下载PDF
Simplified full-depth precast concrete deck panel systems for accelerated bridge construction 被引量:4
14
作者 Zhongguo John Ma Yulin Zhan +2 位作者 Lin Xiao Lungui Li Weiwei Lu 《Journal of Modern Transportation》 2016年第4期251-260,共10页
A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses... A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses of this conceptual deck system. The FEA results are compared to those of the traditional full-depth precast concrete deck panel system. The comparison results show that the mechanical behavior of the new deck system is different from that of the traditional deck system. The concrete decks in the new system act as two-way slabs, instead of the one-way slab in the traditional system. Meanwhile, the connections in both the longitudinal and transverse direc- tions may need to accommodate the negative moments. Compared to those in the traditional system, the longitu- dinal nominal stress at middle span increases a lot in the new deck system and the effective flange width varies significantly. In addition, the dynamic results show that the impact factor is influenced by the spacing of connections. Finally, some design concerns of the new deck system are proposed. 展开更多
关键词 Simplified full-depth precast concrete deckpanel systems ~ Accelerated bridge construction ~ Structuralresponse
下载PDF
Numerical study of a multiple post-tensioned rocking wall-frame system for seismic resilient precast concrete buildings 被引量:1
15
作者 Afshin Naserpour Mojtaba Fathi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第2期377-393,共17页
A multiple rocking wall-frame(MRWF)system,in which the wall panels are directly connected to the adjacent beams and foundation is presented herein.In the MRWF system,the unbonded post-tensioned(PT)tendons are used to ... A multiple rocking wall-frame(MRWF)system,in which the wall panels are directly connected to the adjacent beams and foundation is presented herein.In the MRWF system,the unbonded post-tensioned(PT)tendons are used to promote the self-centering ability,and O-shaped steel dampers are applied to enhance the energy dissipation capacity and reparability of the structure.First,analytical equations are proposed to determine the behavior of the O-shaped dampers.Then,the MRWF system is numerically evaluated for five different models consisting of rocking walls with varying numbers and arrangements while keeping the total effective width of wall panels constant.The numerical results show that with an increase in the number of wall panels and a decrease in the wall width,the hysteretic behavior of the MRWF system tends to the ideal flag-shaped pattern,resulting in little damage to the beams,insignificant strain in the wall toe,negligible residual drifts and damage index of less than 0.2 under severe earthquakes.In contrast,the conventional model demonstrates extensive damage to the structural elements due to undesirable wall-to-frame interaction,which leads to a damage index of 0.78 and residual drifts of 0.42%under seismic loads. 展开更多
关键词 precast wall-frame system rocking behavior POST-TENSIONING O-shaped steel damper residual drift
下载PDF
Development of seismic fragility curves for precast concrete frames with cast-in-situ concrete shear-walls 被引量:1
16
作者 Aliakbar Yahyaabadi Roozbeh Talebkhah Mahdi Adibi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第1期149-167,共19页
Precast reinforced concrete buildings have been well received in some seismic zones worldwide due to advantages such as the ease and the speed of implementation,and the possibility of working in inappropriate atmosphe... Precast reinforced concrete buildings have been well received in some seismic zones worldwide due to advantages such as the ease and the speed of implementation,and the possibility of working in inappropriate atmospheric conditions.In this research,seismic fragility curves were developed for precast concrete frames with a cast-in-situ concrete shear-wall,concerning the important issues of modeling the precast beam-column joints,construction quality,and soil type effects.For this purpose,the incremental dynamic analysis(IDA)was conducted for three-dimensional models of 3-,5-,and 8-story buildings under two record sets corresponding to soil types C and D of the NEHRP code.Beam-column joints were modeled using nonlinear rotational springs with rigid links with respect to the finite size of the joint panel.Results demonstrate that the Weibull distribution can be fitted to the damage state capacities better than the lognormal distribution at the intensities that are more than one standard deviation away from the median damage capacity.The seismic vulnerability of precast structures increases at all damage states as the height of the building increases.It is also observed that soil type has almost no considerable effect on the fragility curve parameters for all damage states considered herein. 展开更多
关键词 fragility curve incremental dynamic analysis precast beam-column joints construction quality soil type effects
下载PDF
Influence of Steel and Carbon Fiber Reinforcement Bars on Seismic Performance of Precast Segmental Bridge Columns 被引量:4
17
作者 布占宇 《宁波大学学报(理工版)》 CAS 2012年第4期75-82,共8页
为了得到快速施工和利用新材料的预制节段桥墩设计方法,研究了部分钢筋替换为碳纤维筋时预制节段桥墩的水平承载力和破坏等级.首先通过与拟静力试验结果的比较证明了仿真分析的正确性,然后研究了部分普通钢筋替换为碳纤维筋,对拟静... 为了得到快速施工和利用新材料的预制节段桥墩设计方法,研究了部分钢筋替换为碳纤维筋时预制节段桥墩的水平承载力和破坏等级.首先通过与拟静力试验结果的比较证明了仿真分析的正确性,然后研究了部分普通钢筋替换为碳纤维筋,对拟静力循环荷载和地震地面运动分别作用时预制节段桥墩响应的影响.结果表明:碳纤维筋能提高桥墩水平承载力,增大有效刚度,降低等效粘滞阻尼比和滞回能量耗散.地震时程计算表明:部分普通钢筋替换为碳纤维筋时,使得预制节段桥墩在较强烈地震底面运动下不倒塌.利用绝对能量法分析了桥墩在地震地面运动下的能量吸收和耗散情况,并主要研究了4种桥墩试件在3种不同地震地面运动作用下的输入能量和滞回能量耗散,结果是随着桥墩输入地震能量的增大滞回能量耗散增长缓慢. 展开更多
关键词 预制施工 预制节段桥墩 地震响应 碳纤维筋 能量耗散
下载PDF
Seismic Behaviour of Beam-Column Joints of Precast and Partial Steel Reinforced Concrete 被引量:1
18
作者 Wanpeng Cheng Licheng Wang +1 位作者 Yupu Song Jun Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第2期108-117,共10页
A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is locate... A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints. 展开更多
关键词 precast and partial steel reinforced concrete(PPSRC) beam-column joints low cyclic test hysteretic curve degradations of strength and stiffness DUCTILITY
下载PDF
A Study on the Flexural Performance of UHPC Precast Deck-Joint Interface by the Exposure of Steel Fiber 被引量:1
19
作者 Kilje Jung Sung Yong Park +2 位作者 Sung Tae Kim Byung-Suk Kim Keunhee Cho 《Engineering(科研)》 2014年第13期1000-1006,共7页
As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corres... As a solution against the serviceability problem caused by the cracks occurring at the UHPC precast deck-joint interface, this study proposes a method exposing the steel fiber at the interface and evaluates the corresponding flexural performance of the lap spliced construction joint. After having slowed down the strength development of the concrete placed in the joint of the precast deck by means of a curing retardant, the concrete at the interface is crushed so as to expose the steel fibers and the change in the flexural performance is observed experimentally according to the exposure of the steel fibers. The results show that, even if the ultimate strength and stiffness of the UHPC precast deck including the joint are mostly determined by the arrangement details of the rebar lap splice, the exposure of the steel fibers can secure stable ductile behavior and reduce the width of the cracks generated at the precast deck-joint interface under service load. 展开更多
关键词 Ultra-High Performance Concrete precast DECK System Steel Fiber EXPOSURE Lap-Spliced Connection 4-Point BENDING Test
下载PDF
Application Prospect of 3D Printing Technology in Refractory Precast Components
20
作者 MAO Limin HU Chenxi +4 位作者 YANG Haiyun LIU Jiwang HE Zehong QING Xiaobin CAI Zhongkai 《China's Refractories》 CAS 2019年第2期7-11,共5页
3D printing is a rapid prototyping technology to shape materials or objects through printing layer by layer driven by digital models, which can be adopted for the manufacture of refractory precast components. Thus, th... 3D printing is a rapid prototyping technology to shape materials or objects through printing layer by layer driven by digital models, which can be adopted for the manufacture of refractory precast components. Thus, the production technology of refractory precast components as well as the technique and advantages of 3D printing was introduced. The feasibility and application prospect of 3D printing concrete, contour crafting and adhesive 3D printing in refractory precast components were presented. 展开更多
关键词 3D printing REFRACTORY precast components rapid PROTOTYPING application PROSPECT
下载PDF
上一页 1 2 218 下一页 到第
使用帮助 返回顶部