Precolumn derivatization LC-MS/MS method for the determination and pharmacokinetic study of glucosamine in human plasma and urine 被引量:3
1
作者 Min Songa, Tai-Jun Hanga, Cheng Wanga, Lin Yangb, Ai-Dong Wenb aDepartment of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing 210009, China bDepartment of Pharmacy, Xijing Hospital, Xi’an 710032, China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期19-28,共10页
A selective precolumn derivatization liquid chromatography–tandem mass spectrometric (LC–MS/MS) method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was... A selective precolumn derivatization liquid chromatography–tandem mass spectrometric (LC–MS/MS) method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was derivatized by o-phthalaldehyde/3-mercaptopropionic acid. Chromatographic separation was performed on a Phenomenex ODS column (150 mm 4.6 mm, 5 mm) using linear gradient elution by a mobile phase consisting of methanol (A), and an aqueous solution containing 0.2% ammonium acetate and 0.1% formic acid (B) at a flow rate of 1 mL/min. Tolterodine tartrate was used as the internal standard (IS). With protein precipitation by acetonitrile and then the simple one-step derivatization, a sensitive bio-assay was achieved with the lower limit of quantitation (LLOQ) as low as 12 ng/mL for plasma. The standard addition calibration curves suitable for clinical sample analysis showed good linearity over the range of 0.012–8.27 mg/mL in plasma and 1.80–84.1 mg/mL in urine. The fully validated method has been successfully applied to a pharmacokinetic study of compound glucosamine sulfate dispersible tablets in health Chinese volunteers receiving single oral doses at 500, 1000 and 1500 mg of glucosamine sulfate, as well as multiple oral doses of 500 mg t.i.d. for 7 consecutive days. 展开更多
关键词 GLUCOSAMINE PHARMACOKINETICS precolumn derivatization LC–MS/MS
下载PDF
Altered Taurine Release in Hypothalamus of Aquaporin-4 Knockout Mice
2
作者 ZHANG Hong-guo XIAO Ying-hong YANG Long-fei SU Wei-heng GUAN Xin-gang WANG Yu FENG Xue-chao MA Tong-hui 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第3期406-408,共3页
Taurine is concentrated in glial cells in the hypothalamus and released in an osmo-dependent manner through volume-sensitive anion channels. Released tanrine acts on glycine receptors on vasopressin neurons to control... Taurine is concentrated in glial cells in the hypothalamus and released in an osmo-dependent manner through volume-sensitive anion channels. Released tanrine acts on glycine receptors on vasopressin neurons to control vasopressin secretion. Water channel AQP4 is abundant in astrocytes in osmosensory areas such as the supraoptic nucleus of hypothalamus. An HPLC-based method was established to quantify taurine release from isolated hypothalamus tissues in wildtype and AQP4 knockout mice. Under the basal condition, there was no difference in taurine release from AQP4^+/+ and AQP4^-/- hypothalamuses. Taurine release from AQP4^-/- hypothalamus under hypoosmotic stimulation was significantly lower than that from AQP4^+/+ mice. AQP4 expression in the glial cells of the hypothalamus may play an important role in osmoregulation oftaurine release and subsequent vasopressin secretion. 展开更多
关键词 AQUAPORIN-4 TAURINE HYPOTHALAMUS HPLC precolumn derivatization
下载PDF
Sensitive analysis of amino acids in injection liquor by reversed-phase HPLC
3
作者 SHANG, ZH YU, YN +2 位作者 GUO, W JIANG, H ZHOU, LM 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1995年第2期163-168,共6页
A convenient derivatization method of amino acids with 1-fluoro-2,4-dinitrobezene as reaction reagent and a separation system were described. The derivative amino acids were separated on a specific chemically bonded p... A convenient derivatization method of amino acids with 1-fluoro-2,4-dinitrobezene as reaction reagent and a separation system were described. The derivative amino acids were separated on a specific chemically bonded phase column with a simple linear gradient elution consisting of aqueous buffer and methanol. The eluate was detected by common ultraviolet absorption detector at 360 nm. The detection limits of amino acids were as low as 10 picomole. This method has been successfully applied to assay amino acid injection liquor used in hospital. It has good reproducibility and precision. The procedures avoid the requirements of particular derivative equipment and analyzer employed in conventional amino acid analysis. 展开更多
关键词 AMINO ACIDS precolumn derivatization REVERSED PHASE SEPARATION UV ABSORPTION DETERMINATION