期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A Proposed Stereochemical Mechanism for the Improved Preparation of Maleic Anhydride Cycloadduct of CLA
1
作者 Jieyu He Jiashu Liao Junyan Qu 《Computational Chemistry》 2021年第3期144-160,共17页
The fatty acid derivatives, prepared from renewable natural oils, can be used as highly promising and potential substitutes for petrochemicals. The study of process improvement and stereochemical mechanism for prepari... The fatty acid derivatives, prepared from renewable natural oils, can be used as highly promising and potential substitutes for petrochemicals. The study of process improvement and stereochemical mechanism for preparing these derivatives would be beneficial for their industrial production. Conjugated linoleic acid (CLA) containing 9<em>cis</em>-11<em>trans</em> (9<em>c</em>, 11<em>t</em>) and 10<em>trans</em>-12<em>cis</em> (10<em>t</em>, 12<em>c</em>) isomers was prepared from <em>Salicornia herbacea</em> seed oil. Maleic anhydride cycloadduct of CLA (MAC) was prepared by an improved process, and it was characterized by FTIR, <sup>1</sup>H and <sup>13</sup>C NMR, <em>etc</em>. A new method to calculate conformers-ratio of CLA or MAC was also developed. Furthermore, the stereochemical mechanism for the improved preparation of MAC was proposed primarily by the calculation method above. The following observations were made: 1) The yield of MAC could reach as high as 96.7% under mild reaction conditions and with an easy and efficient product separation;2) The <em>trans-trans</em> CLA in the<em> s-cis</em> conformation acted as a predominant reactant to <em>Diels-Alder</em> [4 + 2] cycloaddition of maleic anhydride, which was the main reaction occurred simultaneously with catalytic configurational isomerizations of CLA in one step;3) From all studied CLA conformers, the most stable conformation was the s-trans conformation of trans-trans CLA, while the <em>s-cis</em> conformation of <em>trans-trans</em> CLA had the most favorable structural parameters for cyclohexenyl ring formation;4) Four MAC conformers derived from 9<em>c</em>, 11<em>t</em>- and 10<em>t</em>, 12c-CLA, were obtained as final main products that were determined to be <em>cis</em>-cycloadducts;5) The <em>endo/exo</em> ratios of the <em>cis</em>- cycloadducts derived from 9<em>c</em>, 11<em>t</em>- and 10<em>t</em>, 12<em>c</em>-CLA, were 2.14:1 and 1.99:1, respectively;and 6) The results obtained from the calculation method above were in excellent accordance with those from our experiments. 展开更多
关键词 Maleic Anhydride Cycloadducts Improved preparation Conjugated Linoleic Acid Stereochemical Mechanism Conformers-Ratio Calculation Conformational Isomerization
下载PDF
Colometer:A real-time quality feedback system for screening colonoscopy 被引量:2
2
作者 Dobromir Filip Xuexin Gao +5 位作者 Leticia Angulo-Rodriguez Martin P Mintchev Shane M Devlin Alaa Rostom Wayne Rosen Christopher N Andrews 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第32期4270-4277,共8页
AIM:To investigate the performance of a new software-based colonoscopy quality assessment system.METHODS:The software-based system employs a novel image processing algorithm which detects the levels of image clarity,w... AIM:To investigate the performance of a new software-based colonoscopy quality assessment system.METHODS:The software-based system employs a novel image processing algorithm which detects the levels of image clarity,withdrawal velocity,and level of the bowel preparation in a real-time fashion from live video signal.Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists.Subsequently,an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization(scored 1-5;1,when the percentage was 1%-20%;2,when the percentage was 21%-40%,etc.).In order to test the proposed velocity and blurriness thresholds,screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected,automatically processed and rated.Quality ratings on the withdrawal were compared to the insertion in the same patients.Then,3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal(scored 1-5;1,poor;3,average;5,excellent) based on 3 major aspects:image quality,colon preparation,and withdrawal velocity.The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient.RESULTS:Fourteen screening colonoscopies were assessed.Adenomatous polyps were detected in 4/14(29%) of the collected colonoscopy video samples.As a proof of concept,the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps(average percent time with adequate visualization:79% ± 5% for withdrawal and 50% ± 14% for insertion,P < 0.01).Withdrawal times during which no polyps were removed ranged from 4-12 min.The median quality rating from the automated system and the reviewers was 3.45 [interquartile range(IQR),3.1-3.68] and 3.00(IQR,2.33-3.67) respectively for all colonoscopy video samples.The automated rating revealed a strong correlation with the reviewer's rating(ρ coefficient= 0.65,P = 0.01).There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating(Spearman r coefficient= 0.59,P = 0.03).There was no correlation of automated overall quality rating with mean endoscopists image quality rating(Spearman r coefficient= 0.41,P = 0.15).CONCLUSION:The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments.Further study is required to validate this approach. 展开更多
关键词 Colonoscopy Quality assurance Quality improvement Withdrawal time Colon cancer Bowel preparation
下载PDF
AN IMPROVED METHOD FOR PREPARING 2—ALKOXY—5—FLUORO—3H—4—PYRIMIDONE~△
3
作者 Chang Jun SUN Zai Cheng CHEN +4 位作者 Yi MENG Yi Gui WANG Peng XUE Jian Guo ZHANG Gui Xiang CUI Department of Chemistry, Shandong University, Jinan 250100 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第7期591-592,共2页
In this paper, we report an improved method for preparing 2--alkoxy 5 fluoro--3H --4--pyrimidone from 2--chloro--5--fluoro--3H--4--pyrimidone and sodium alkoxide under normal pressure at reflux temperature. Some new c... In this paper, we report an improved method for preparing 2--alkoxy 5 fluoro--3H --4--pyrimidone from 2--chloro--5--fluoro--3H--4--pyrimidone and sodium alkoxide under normal pressure at reflux temperature. Some new compounds were synthesized in higher yield by this method. 展开更多
关键词 ALKOXY AN IMPROVED METHOD FOR PREPARING 2 FLUORO PYRIMIDONE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部