When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necess...When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.展开更多
Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease i...Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease in the world. The objective was to determine the prevalence, treatment rate and control of hypertension. Methods: This was a cross-sectional and descriptive study which took place over a period of 6 months in a hospital environment and in the general population. Results: Of the 1000 participants, 637 had hypertension, giving a prevalence of 63.70% with a female predominance. Thirty-three percent (33%) were unaware of their high blood pressure. The age group 60 and more was the most represented (44%). A proportion of 33 and 23.20 were overweight and obese participants, respectively. Male subjects were more overweight than female, unlike obesity which was more common among female subjects. Sixty-two percent (62%) of hypertensives were treated, of whom 44% were non-compliant. The excessively high cost and consumption of medications as needed were the main factors in therapeutic non-compliance. Twenty-two percent (22%) of all hypertensive patients and 35% of treated hypertensive patients were controlled. Women were more treated but less observant and less controlled than men. Therapeutic coverage and combination therapy rates were lower in rural areas. Hypertensives who had a high level of education were better treated and controlled than those who had no level. Conclusion: High blood pressure remains a real public health problem in Mali. It is more common in people aged 60 and over and in females. One in three hypertensives were unaware of their hypertension. The majority received antihypertensive treatments, but only a minority of them had their hypertension controlled.展开更多
Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determin...Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determine the factors associated with blood pressure control. Methodology: This was a descriptive cross-sectional study with an analytical focus over 7 months. Patients were recruited as outpatients and all underwent ambulatory blood pressure measure, glycated hemoglobin and creatinine measurements, and assessment of compliance with treatment. Results: During this period 116 patients were collected. The predominance was female 69%. The mean age of the patients was 62 ± 7 years with a peak between 60 and 70 years. The average age of hypertension was 12 years and that of diabetes 6 1/2 years. The most frequently associated cardiovascular risk factor was a sedentary lifestyle (71.5%) after age. 57.8% of patients were not controlled at the office, with a predominance of systolic hypertension (58.2%). 61.6% of patients were controlled by ambulatory blood pressure measure, a rate of 47.8% of white coat hypertension. Glycemic control was observed in 42.2% of cases and 87% of patients had good renal function (glomerular filter rate ≥ 60 ml/mn). Therapeutic compliance was good in 53.4% of cases and dual therapy was the most used therapeutic modality 44.8% (52 patients) followed by triple therapy. The factors associated with poor blood pressure control were glycemic imbalance, non-compliance and monotherapy. Dual therapy had a protective effect. Conclusion: The association of hypertension and type 2 diabetes is frequent. The risk of occurrence increases with age. Ambulatory blood pressure measure is the best method to assess blood pressure control. Optimization of blood pressure control should also include optimization of glycemic control.展开更多
Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor...Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor(SCWR)is a fourth-generation conceptual reactor.In an SCWR,the non-linear dynamics of the reactor require a controller capable of control-ling the nonlinearities.In this study,a pressure-tube-type SCWR was controlled during reactor power maneuvering with a higher order sliding mode,and the reactor outgoing steam temperature and pressure were controlled simultaneously.In an SCWR,the temperature,pressure,and power must be maintained at a setpoint(desired value)during power maneuvering.Reactor point kinetics equations with three groups of delayed neutrons were used in the simulation.Higher-order and classic sliding mode controllers were separately manufactured to control the plant and were compared with the PI controllers speci-fied in previous studies.The controlled parameters were reactor power,steam temperature,and pressure.Notably,for these parameters,the PI controller had certain instabilities in the presence of disturbances.The classic sliding mode controller had a higher accuracy and stability;however its main drawback was the chattering phenomenon.HOSMC was highly accurate and stable and had a small computational cost.In reality,it followed the desired values without oscillations and chattering.展开更多
Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure t...Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.展开更多
The load-bearing performance(LBP)of pumpable supports(PPS)is crucial for the stability of longwall pre-driven recovery room(PRR)surrounding rock.However,the unbalanced bearing coefficient(UBC)of the PPS(undertaking un...The load-bearing performance(LBP)of pumpable supports(PPS)is crucial for the stability of longwall pre-driven recovery room(PRR)surrounding rock.However,the unbalanced bearing coefficient(UBC)of the PPS(undertaking unequal load along the mining direction)has not been investigated.A mechanical model of the PRR was established,considering the main roof cantilever beam structure,to derive an assessment formula for the load,the failure criteria,and the UBC of the PPS.Subsequently,the generation mechanisms,and influencing factors of the UBC were revealed.Global sensitivity analysis shows that the main roof hanging length(l_(2))and the spacing between the PPS(r)significantly impact the UBC.A novel design of the PPS and the coupling control technology were proposed and applied to reduce the UBC of the PPS in the adjacent longwall PRR.Monitor results showed no failure of the PPS at the test site,with the UBC(ζ)reduced to 1.1 consistent with the design value(1.15)basically,fully utilizing the collaborative LBP of the PPS.Finally,the maximum roof-to-floor convergence of the PRR was 234 mm,effectively controlling the stability of the surrounding rock of the PRR and ensuring the mining equipment recovery.展开更多
In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of t...In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.展开更多
Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled tr...Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.展开更多
In this paper, the optimal control problem of parabolic integro-differential equations is solved by gradient recovery based two-grid finite element method. Piecewise linear functions are used to approximate state and ...In this paper, the optimal control problem of parabolic integro-differential equations is solved by gradient recovery based two-grid finite element method. Piecewise linear functions are used to approximate state and co-state variables, and piecewise constant function is used to approximate control variables. Generally, the optimal conditions for the problem are solved iteratively until the control variable reaches error tolerance. In order to calculate all the variables individually and parallelly, we introduce a gradient recovery based two-grid method. First, we solve the small scaled optimal control problem on coarse grids. Next, we use the gradient recovery technique to recover the gradients of state and co-state variables. Finally, using the recovered variables, we solve the large scaled optimal control problem for all variables independently. Moreover, we estimate priori error for the proposed scheme, and use an example to validate the theoretical results.展开更多
Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has develop...Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has developed a fin-less control technology called Stagnation Pressure Reaction Control(SPRC)that takes stagnation pressure air and directs it sideways to control non-spinning projectiles.In a previous study,this technology was demonstrated at Mach 2 wind-tunnel conditions to achieve up to 1.5°controllable angle of incidence for a non-spinning,aerodynamically unstable projectile-like test object.In an operational scenario,the decelerating projectile will experience a decline in control force while the simultaneous forward shift of the center of pressure increases the need for control force.Furthermore,angles of incidence exceeding 1.5°will be experienced under realistic flight conditions,especially against maneuvering targets.This work addresses these challenges and presents an operational feasibility study for a practical application of SPRC in a non-spinning mid-caliber gun-launched projectile,using experiment data on control latency and force of the earlier study.It illustrates the combined effect of the control-and stability dynamics and underlines the potential of an SPRC projectile as a precisionoperation ammunition.This research revealed that SPRC technology can stabilize and control the hypothesized projectile in a direct fire scenario against stationary and maneuvering targets.展开更多
Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cor...Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cores and cannot guide the development of deep oil and gas resources on Earth. The fundamental reason is the lack of temperature and pressure control in in-situ coring environments. In this paper, a pressure control method of a coring device is studied. The theory and method of deep intelligent temperature-pressure coupling control are innovatively proposed, and a multifield coupling dynamic sealing model is established. The optimal cardinality three term PID (Proportional-Integral-Differential) intelligent control algorithm of pressure system is developed. The temperature-pressure characteristic of the gas-liquid two-phase cavity is analyzed, and the pressure intelligent control is carried out based on three term PID control algorithms. An in-situ condition-preserved coring (ICP-Coring) device is developed, and an intelligent control system for the temperature and pressure of the coring device is designed and verified by experiments. The results show that the temperature-pressure coupling control system can effectively realize stable sealing under temperature-pressure fields of 140 MPa and 150 °C. The temperature-pressure coupling control method can accurately realize a constant pressure inside the coring device. The maximum working pressure is 140 MPa, and the effective pressure compensation range is 20 MPa. The numerical simulation experiment of pressure system control algorithm is carried out, and the optimal cardinality and three term coefficients are obtained. The pressure steady-state error is less than 0.01%. The method of temperature-pressure coupling control has guiding significance for coring device research, and is also the basis for temperature-pressure decoupling control in ICP-Coring.展开更多
In this study,a duct is considered and special attention is paid to a passive method for the control of the base pressure relying on the use of a cavity with a variable aspect ratio.The Mach number considered is 1.8,a...In this study,a duct is considered and special attention is paid to a passive method for the control of the base pressure relying on the use of a cavity with a variable aspect ratio.The Mach number considered is 1.8,and the area ratio of the duct is 2.56.In particular,two cavities are examined,their sizes being 3:3 and 6:3.The used L/D spans the interval 1–10 while the NPRs(nozzle pressure ratio)range from 2 to 9.The results show that the control becomes effective once the nozzles are correctly expanded or under-expanded.The pressure contours at different NPR and L/D are presented.It is shown that the NPR and cavity location strongly influence the base pressure.The NPR,Mach number,and cavity aspect ratio have a strong effect on the base pressure in the wake region.展开更多
Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hy...Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.展开更多
Background: Hypertension is a common chronic disease and an important public health problem. The prevention of complications depends on hypertension control. Aim: To assess blood pressure control, complication presenc...Background: Hypertension is a common chronic disease and an important public health problem. The prevention of complications depends on hypertension control. Aim: To assess blood pressure control, complication presence, and their influencing factors. Methods: This cross-sectional study was conducted on patients with hypertension attending a private medical facility, a governmental facility, and a primary health care center in Khartoum, Sudan, between September 2022 and February 2023. Statistical Package for Special Sciences version 25 was used for data analysis;frequency and percentage were used to describe the qualitative variables. A chi-square test was used for co-relation analysis;a P-value ≤ 0.05 was considered statistically significant, and the confidence interval was 95%. Results: The study included 250 participants;55.6% were males. Their age was 58.77 ± 6.80 years, and they had hypertension for 10.7 ± 8.51 years. The duration of the disease was 10.7 ± 8.51 years. Systolic blood pressure was 127.1 ± 11.3 mm hg, and diastolic blood pressure was 81.6 ± 7.1 mm hg. Of the participants, 76.4% had controlled hypertension, while 27.6% had complications due to hypertension. Controlled blood pressure was associated with females, age group 40 - 60 years, normal waist circumference, and high adherence level (P ≤ 0.05). The presence of complications was associated with males, participants older than 60 years, and a low adherence level (P ≤ 0.05). Conclusions: In Sudan, the level of control is good;nonetheless, not all patients achieve it. Availability and access to treatment facilities and medications should be improved. Proper patient counseling should be offered, as well as continuous care.展开更多
Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and an...Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and another 80 patients with diabetes(diabetic group)who were admitted to the Department of Nephrology and Endocrinology at our hospital from October 2021 to October 2022 was conducted.The general data of the two groups were compared,the influencing factors associated with the two groups were analyzed unilaterally,and unconditional dichotomous logistic regression was performed to analyze the influencing factors in patients with diabetic nephropathy.Results:There were no significant differences in high-density lipoprotein,systolic blood pressure,diastolic blood pressure,and creatinine between the two groups(P>0.05);however,compared with the diabetic group,the DN group had significantly elevated glycated hemoglobin,low-density lipoprotein,24-h urine protein,insulin resistance,and diabetes duration≥10 years(P<0.05).Conclusion:The clinical research on the correlation between the incidence of hypertension and the control of blood pressure in patients with diabetic nephropathy should be strengthened in order to formulate reasonable and feasible treatment plans.展开更多
This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made usi...This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made using the error and process input parameters in a closed loop system in order to obtain better controller performance for set-point change and load disturbances. This on-line tuning method reduces operator involvement and enhances the controller performance to a wide operating range. The hierarchical control scheme consists of an intelligent upper level supervisory fuzzy controller and a lower level direct fuzzy controller. The upper level controller provides a mechanism to the main goal of the system and the lower level controller delivers the solutions to a particular situation. The control algorithm for the proposed scheme has been developed and tested using an ARM7 microcontroller-based embedded target board for a nonlinear pressure process having dead time. To demonstrate the effectiveness, the results of the proposed hierarchical controller, fuzzy controller and conventional proportional-integral (PI) controller are analyzed. The results prove that the SHFC performance is better in terms of stability and robustness than the conventional control methods.展开更多
The performance of the designed digital electro-pneumatic cabin pressure control system for the cabin pressure schedule of transport aircraft is investigated.For the purpose of this study,an experimental setup consist...The performance of the designed digital electro-pneumatic cabin pressure control system for the cabin pressure schedule of transport aircraft is investigated.For the purpose of this study,an experimental setup consisting of a simulated hermetic cabin and altitude simulation chamber is configured for cabin pressure control system operation.A series of experimental tests are executed to evaluate the performance of the cabin pressure control system.The parameters of the PID controller are optimized.In the optimization process,the variation regularity of the rate of cabin pressure change under various conditions is considered.An approach to prioritize the control of the rate of change of cabin pressure based on the flight status model is proposed and verified experimentally.The experimental results indicate that the proposed approach can be adopted for the designed digital electro-pneumatic cabin pressure control system to obtain a better cabin pressure schedule and rate of cabin pressure change.展开更多
Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In thi...Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In this study, we try to find out the association between methods above and prognostic indicators.展开更多
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonline...The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mecha- nisms employing the error and change in error of the controlled variable as input parameters, the current cham- ber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the pro- posed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consis- tent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.展开更多
This work aimed at revealing the mechanism of strong ground pressure behaviour(SGPB)induced by high-position hard roof(HHR).Based on the supporting structures model of HHR,a modified voussoir beam mechanical model for...This work aimed at revealing the mechanism of strong ground pressure behaviour(SGPB)induced by high-position hard roof(HHR).Based on the supporting structures model of HHR,a modified voussoir beam mechanical model for HHR was established by considering the gangue support coefficient,through which the modified expressions of limit breaking span and breaking energy of HHR were deduced.Combined with the relationship between the dynamic-static loading stress of supporting body(hydraulic support and coal wall)and its comprehensive supporting strength,the criteria of ground pressure behaviour(GPB)induced by HHR were discussed.The types of Ⅰ_(1),Ⅰ_(2),Ⅱ_(1),andⅡ_(2) of GPB were interpreted.Results showed that types Ⅰ_(1) and Ⅰ_(2) were the main forms of SGPB in extra-thick coal seam mining.The main manifestation of SGPB was static stress,which was mainly derived from the instability of HHR rather than fracture.Accordingly,an innovative control technology was proposed,which can weaken static load by vertical-well separated fracturing HHR.The research results have been successfully applied to the 8101 working face in Tashan coal mine,Shanxi Province,China.The results of a digital borehole camera observation and stress monitoring proved the rationality of the GPB criteria.The control technology was successful,paving the way for new possibilities to HHR control for safety mining.展开更多
基金supported by the Structures and Materials(S&M)Research Lab of Prince Sultan Universitysupport of Prince Sultan University in paying the article processing charges(APC)for this publication.
文摘When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.
文摘Introduction: High blood pressure is defined as blood pressure greater than or equal to 140 mm Hg for systolic and or 90 mm Hg for diastolic. It constitutes a major public health problem, the leading chronic disease in the world. The objective was to determine the prevalence, treatment rate and control of hypertension. Methods: This was a cross-sectional and descriptive study which took place over a period of 6 months in a hospital environment and in the general population. Results: Of the 1000 participants, 637 had hypertension, giving a prevalence of 63.70% with a female predominance. Thirty-three percent (33%) were unaware of their high blood pressure. The age group 60 and more was the most represented (44%). A proportion of 33 and 23.20 were overweight and obese participants, respectively. Male subjects were more overweight than female, unlike obesity which was more common among female subjects. Sixty-two percent (62%) of hypertensives were treated, of whom 44% were non-compliant. The excessively high cost and consumption of medications as needed were the main factors in therapeutic non-compliance. Twenty-two percent (22%) of all hypertensive patients and 35% of treated hypertensive patients were controlled. Women were more treated but less observant and less controlled than men. Therapeutic coverage and combination therapy rates were lower in rural areas. Hypertensives who had a high level of education were better treated and controlled than those who had no level. Conclusion: High blood pressure remains a real public health problem in Mali. It is more common in people aged 60 and over and in females. One in three hypertensives were unaware of their hypertension. The majority received antihypertensive treatments, but only a minority of them had their hypertension controlled.
文摘Objective: The association hypertension and diabetes is important. The two pathologies may influence each other. The aim was to study the correlation between glycemic control and blood pressure control and to determine the factors associated with blood pressure control. Methodology: This was a descriptive cross-sectional study with an analytical focus over 7 months. Patients were recruited as outpatients and all underwent ambulatory blood pressure measure, glycated hemoglobin and creatinine measurements, and assessment of compliance with treatment. Results: During this period 116 patients were collected. The predominance was female 69%. The mean age of the patients was 62 ± 7 years with a peak between 60 and 70 years. The average age of hypertension was 12 years and that of diabetes 6 1/2 years. The most frequently associated cardiovascular risk factor was a sedentary lifestyle (71.5%) after age. 57.8% of patients were not controlled at the office, with a predominance of systolic hypertension (58.2%). 61.6% of patients were controlled by ambulatory blood pressure measure, a rate of 47.8% of white coat hypertension. Glycemic control was observed in 42.2% of cases and 87% of patients had good renal function (glomerular filter rate ≥ 60 ml/mn). Therapeutic compliance was good in 53.4% of cases and dual therapy was the most used therapeutic modality 44.8% (52 patients) followed by triple therapy. The factors associated with poor blood pressure control were glycemic imbalance, non-compliance and monotherapy. Dual therapy had a protective effect. Conclusion: The association of hypertension and type 2 diabetes is frequent. The risk of occurrence increases with age. Ambulatory blood pressure measure is the best method to assess blood pressure control. Optimization of blood pressure control should also include optimization of glycemic control.
文摘Nuclear power plants exhibit non-linear and time-variable dynamics.Therefore,designing a control system that sets the reactor power and forces it to follow the desired load is complicated.A supercritical water reactor(SCWR)is a fourth-generation conceptual reactor.In an SCWR,the non-linear dynamics of the reactor require a controller capable of control-ling the nonlinearities.In this study,a pressure-tube-type SCWR was controlled during reactor power maneuvering with a higher order sliding mode,and the reactor outgoing steam temperature and pressure were controlled simultaneously.In an SCWR,the temperature,pressure,and power must be maintained at a setpoint(desired value)during power maneuvering.Reactor point kinetics equations with three groups of delayed neutrons were used in the simulation.Higher-order and classic sliding mode controllers were separately manufactured to control the plant and were compared with the PI controllers speci-fied in previous studies.The controlled parameters were reactor power,steam temperature,and pressure.Notably,for these parameters,the PI controller had certain instabilities in the presence of disturbances.The classic sliding mode controller had a higher accuracy and stability;however its main drawback was the chattering phenomenon.HOSMC was highly accurate and stable and had a small computational cost.In reality,it followed the desired values without oscillations and chattering.
基金This study was funded by Major Science and Technology Projects of Jiangxi Provincial Science and Technology Department(20152ACG70009).
文摘Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice.
基金financial support provided by the Xinjiang Uygur Autonomous Region Key R&D Project Task Special-Department and Department Linkage Project(No.2022B01051)Major Project of Regional Joint Foundation of China(No.U21A20107)+1 种基金Hunan Provincial Natural Science Foundation of China(No.2024JJ4021)the Xinjiang Uygur Autonomous Region Tianchi Introduction Plan(No.2024XGYTCYC03)。
文摘The load-bearing performance(LBP)of pumpable supports(PPS)is crucial for the stability of longwall pre-driven recovery room(PRR)surrounding rock.However,the unbalanced bearing coefficient(UBC)of the PPS(undertaking unequal load along the mining direction)has not been investigated.A mechanical model of the PRR was established,considering the main roof cantilever beam structure,to derive an assessment formula for the load,the failure criteria,and the UBC of the PPS.Subsequently,the generation mechanisms,and influencing factors of the UBC were revealed.Global sensitivity analysis shows that the main roof hanging length(l_(2))and the spacing between the PPS(r)significantly impact the UBC.A novel design of the PPS and the coupling control technology were proposed and applied to reduce the UBC of the PPS in the adjacent longwall PRR.Monitor results showed no failure of the PPS at the test site,with the UBC(ζ)reduced to 1.1 consistent with the design value(1.15)basically,fully utilizing the collaborative LBP of the PPS.Finally,the maximum roof-to-floor convergence of the PRR was 234 mm,effectively controlling the stability of the surrounding rock of the PRR and ensuring the mining equipment recovery.
基金The authors are grateful for the financial support from the National Natural Science Foundation of China(No.51827901&No.52274133)the Program for Guangdong Introducing Innovative and Enterpreneurial Teams(No.2019ZT08G315)the Shenzhen National Science Fund for Distinguished Young Scholars(RCJC20210706091948015).
文摘In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.
基金The Project of the National Ministry of Industry and Information Technology[2020-0103-3-1-1]The Project of Beijing Science and technology“capital characteristics”[Z181100001718007]。
文摘Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.
文摘In this paper, the optimal control problem of parabolic integro-differential equations is solved by gradient recovery based two-grid finite element method. Piecewise linear functions are used to approximate state and co-state variables, and piecewise constant function is used to approximate control variables. Generally, the optimal conditions for the problem are solved iteratively until the control variable reaches error tolerance. In order to calculate all the variables individually and parallelly, we introduce a gradient recovery based two-grid method. First, we solve the small scaled optimal control problem on coarse grids. Next, we use the gradient recovery technique to recover the gradients of state and co-state variables. Finally, using the recovered variables, we solve the large scaled optimal control problem for all variables independently. Moreover, we estimate priori error for the proposed scheme, and use an example to validate the theoretical results.
文摘Controlled,guided munitions can reduce dispersion in the shot,while providing the capability of engaging both stationary and maneuvering targets.The Netherlands Organisation for Applied Scientific Research has developed a fin-less control technology called Stagnation Pressure Reaction Control(SPRC)that takes stagnation pressure air and directs it sideways to control non-spinning projectiles.In a previous study,this technology was demonstrated at Mach 2 wind-tunnel conditions to achieve up to 1.5°controllable angle of incidence for a non-spinning,aerodynamically unstable projectile-like test object.In an operational scenario,the decelerating projectile will experience a decline in control force while the simultaneous forward shift of the center of pressure increases the need for control force.Furthermore,angles of incidence exceeding 1.5°will be experienced under realistic flight conditions,especially against maneuvering targets.This work addresses these challenges and presents an operational feasibility study for a practical application of SPRC in a non-spinning mid-caliber gun-launched projectile,using experiment data on control latency and force of the earlier study.It illustrates the combined effect of the control-and stability dynamics and underlines the potential of an SPRC projectile as a precisionoperation ammunition.This research revealed that SPRC technology can stabilize and control the hypothesized projectile in a direct fire scenario against stationary and maneuvering targets.
基金supported by the National Natural Science Foundation of China(grant numbers 51827901,51805340)funded by the Program for Guangdong Introducing Innovative and Enterpreneurial Teams(No.2019ZT08G315)Shenzhen Basic Research Program(General Program)(No.JCYJ20190808153416970).
文摘Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cores and cannot guide the development of deep oil and gas resources on Earth. The fundamental reason is the lack of temperature and pressure control in in-situ coring environments. In this paper, a pressure control method of a coring device is studied. The theory and method of deep intelligent temperature-pressure coupling control are innovatively proposed, and a multifield coupling dynamic sealing model is established. The optimal cardinality three term PID (Proportional-Integral-Differential) intelligent control algorithm of pressure system is developed. The temperature-pressure characteristic of the gas-liquid two-phase cavity is analyzed, and the pressure intelligent control is carried out based on three term PID control algorithms. An in-situ condition-preserved coring (ICP-Coring) device is developed, and an intelligent control system for the temperature and pressure of the coring device is designed and verified by experiments. The results show that the temperature-pressure coupling control system can effectively realize stable sealing under temperature-pressure fields of 140 MPa and 150 °C. The temperature-pressure coupling control method can accurately realize a constant pressure inside the coring device. The maximum working pressure is 140 MPa, and the effective pressure compensation range is 20 MPa. The numerical simulation experiment of pressure system control algorithm is carried out, and the optimal cardinality and three term coefficients are obtained. The pressure steady-state error is less than 0.01%. The method of temperature-pressure coupling control has guiding significance for coring device research, and is also the basis for temperature-pressure decoupling control in ICP-Coring.
文摘In this study,a duct is considered and special attention is paid to a passive method for the control of the base pressure relying on the use of a cavity with a variable aspect ratio.The Mach number considered is 1.8,and the area ratio of the duct is 2.56.In particular,two cavities are examined,their sizes being 3:3 and 6:3.The used L/D spans the interval 1–10 while the NPRs(nozzle pressure ratio)range from 2 to 9.The results show that the control becomes effective once the nozzles are correctly expanded or under-expanded.The pressure contours at different NPR and L/D are presented.It is shown that the NPR and cavity location strongly influence the base pressure.The NPR,Mach number,and cavity aspect ratio have a strong effect on the base pressure in the wake region.
文摘Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.
文摘Background: Hypertension is a common chronic disease and an important public health problem. The prevention of complications depends on hypertension control. Aim: To assess blood pressure control, complication presence, and their influencing factors. Methods: This cross-sectional study was conducted on patients with hypertension attending a private medical facility, a governmental facility, and a primary health care center in Khartoum, Sudan, between September 2022 and February 2023. Statistical Package for Special Sciences version 25 was used for data analysis;frequency and percentage were used to describe the qualitative variables. A chi-square test was used for co-relation analysis;a P-value ≤ 0.05 was considered statistically significant, and the confidence interval was 95%. Results: The study included 250 participants;55.6% were males. Their age was 58.77 ± 6.80 years, and they had hypertension for 10.7 ± 8.51 years. The duration of the disease was 10.7 ± 8.51 years. Systolic blood pressure was 127.1 ± 11.3 mm hg, and diastolic blood pressure was 81.6 ± 7.1 mm hg. Of the participants, 76.4% had controlled hypertension, while 27.6% had complications due to hypertension. Controlled blood pressure was associated with females, age group 40 - 60 years, normal waist circumference, and high adherence level (P ≤ 0.05). The presence of complications was associated with males, participants older than 60 years, and a low adherence level (P ≤ 0.05). Conclusions: In Sudan, the level of control is good;nonetheless, not all patients achieve it. Availability and access to treatment facilities and medications should be improved. Proper patient counseling should be offered, as well as continuous care.
文摘Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and another 80 patients with diabetes(diabetic group)who were admitted to the Department of Nephrology and Endocrinology at our hospital from October 2021 to October 2022 was conducted.The general data of the two groups were compared,the influencing factors associated with the two groups were analyzed unilaterally,and unconditional dichotomous logistic regression was performed to analyze the influencing factors in patients with diabetic nephropathy.Results:There were no significant differences in high-density lipoprotein,systolic blood pressure,diastolic blood pressure,and creatinine between the two groups(P>0.05);however,compared with the diabetic group,the DN group had significantly elevated glycated hemoglobin,low-density lipoprotein,24-h urine protein,insulin resistance,and diabetes duration≥10 years(P<0.05).Conclusion:The clinical research on the correlation between the incidence of hypertension and the control of blood pressure in patients with diabetic nephropathy should be strengthened in order to formulate reasonable and feasible treatment plans.
文摘This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made using the error and process input parameters in a closed loop system in order to obtain better controller performance for set-point change and load disturbances. This on-line tuning method reduces operator involvement and enhances the controller performance to a wide operating range. The hierarchical control scheme consists of an intelligent upper level supervisory fuzzy controller and a lower level direct fuzzy controller. The upper level controller provides a mechanism to the main goal of the system and the lower level controller delivers the solutions to a particular situation. The control algorithm for the proposed scheme has been developed and tested using an ARM7 microcontroller-based embedded target board for a nonlinear pressure process having dead time. To demonstrate the effectiveness, the results of the proposed hierarchical controller, fuzzy controller and conventional proportional-integral (PI) controller are analyzed. The results prove that the SHFC performance is better in terms of stability and robustness than the conventional control methods.
文摘The performance of the designed digital electro-pneumatic cabin pressure control system for the cabin pressure schedule of transport aircraft is investigated.For the purpose of this study,an experimental setup consisting of a simulated hermetic cabin and altitude simulation chamber is configured for cabin pressure control system operation.A series of experimental tests are executed to evaluate the performance of the cabin pressure control system.The parameters of the PID controller are optimized.In the optimization process,the variation regularity of the rate of cabin pressure change under various conditions is considered.An approach to prioritize the control of the rate of change of cabin pressure based on the flight status model is proposed and verified experimentally.The experimental results indicate that the proposed approach can be adopted for the designed digital electro-pneumatic cabin pressure control system to obtain a better cabin pressure schedule and rate of cabin pressure change.
文摘Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In this study, we try to find out the association between methods above and prognostic indicators.
基金Supported by National Natural Science Foundation of China(Grant No.51575199)
文摘The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mecha- nisms employing the error and change in error of the controlled variable as input parameters, the current cham- ber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the pro- posed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consis- tent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.
基金This work was jointly supported by the National Natural Science Foundation of China(No.51974042)the Shanxi Province Science and Technology Plan Exposed Bidding Project(No.20191101015)+3 种基金the Open Project Program of Key Laboratory of Mine Disaster Prevention and Control(No.JMDPC202102)the Scientific Research Project of Introducing Talents in Guizhou University(No.202045)the Open Project Program of National Engineering Technology Research Center of Development and Utilization for Phosphorus Resources(NECP202210)the Growth Project of Young Scientific and Technological Talents in Universities of Guizhou Province(KY2022139).
文摘This work aimed at revealing the mechanism of strong ground pressure behaviour(SGPB)induced by high-position hard roof(HHR).Based on the supporting structures model of HHR,a modified voussoir beam mechanical model for HHR was established by considering the gangue support coefficient,through which the modified expressions of limit breaking span and breaking energy of HHR were deduced.Combined with the relationship between the dynamic-static loading stress of supporting body(hydraulic support and coal wall)and its comprehensive supporting strength,the criteria of ground pressure behaviour(GPB)induced by HHR were discussed.The types of Ⅰ_(1),Ⅰ_(2),Ⅱ_(1),andⅡ_(2) of GPB were interpreted.Results showed that types Ⅰ_(1) and Ⅰ_(2) were the main forms of SGPB in extra-thick coal seam mining.The main manifestation of SGPB was static stress,which was mainly derived from the instability of HHR rather than fracture.Accordingly,an innovative control technology was proposed,which can weaken static load by vertical-well separated fracturing HHR.The research results have been successfully applied to the 8101 working face in Tashan coal mine,Shanxi Province,China.The results of a digital borehole camera observation and stress monitoring proved the rationality of the GPB criteria.The control technology was successful,paving the way for new possibilities to HHR control for safety mining.