Measurment of gas-liquid two-phase slug flow with a Venturi meter based on blind source separation
1
作者 王微微 梁霄 张明柱 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第9期1447-1452,共6页
We propose a novel flow measurement method for gas–liquid two-phase slug flow by using the blind source separation technique. The flow measurement model is established based on the fluctuation characteristics of diff... We propose a novel flow measurement method for gas–liquid two-phase slug flow by using the blind source separation technique. The flow measurement model is established based on the fluctuation characteristics of differential pressure(DP) signals measured from a Venturi meter. It is demonstrated that DP signals of two-phase flow are a linear mixture of DP signals of single phase fluids. The measurement model is a combination of throttle relationship and blind source separation model. In addition, we estimate the mixture matrix using the independent component analysis(ICA) technique. The mixture matrix could be described using the variances of two DP signals acquired from two Venturi meters. The validity of the proposed model was tested in the gas–liquid twophase flow loop facility. Experimental results showed that for most slug flow the relative error is within 10%.We also find that the mixture matrix is beneficial to investigate the flow mechanism of gas–liquid two-phase flow. 展开更多
关键词 Two-phase slug flow Flow measurement Differential pressure Blind source separation Independent component analysis
下载PDF
Optimum Heating of Thick-Walled Pressure Components Assuming a Quasi-steady State of Temperature Distribution 被引量:1
2
作者 Piotr Dzierwa Marcin Trojan +2 位作者 Dawid Taler Katarzyna Kamińska Jan Taler 《Journal of Thermal Science》 SCIE EI CAS CSCD 2016年第4期380-388,共9页
As a result of the development of wind farms,the gas- steam blocks,which shall quickly ensure energy supply in case the wind velocity is too low,are introduced to the energy system.To shorten the start-up time of the ... As a result of the development of wind farms,the gas- steam blocks,which shall quickly ensure energy supply in case the wind velocity is too low,are introduced to the energy system.To shorten the start-up time of the gas-steam and conventional blocks,the structure of the basic components of the blocks are changed,e.g.by reducing the diameter of the boiler,the thickness of its wall is also reduced.The attempts were also made to revise the currently binding TRD 301 regulations,replacing them by the EN 12952-3 European Standard,to reduce the allowable heating and cooling rates of thick walled boiler components.The basic assumption,on which the boiler regulations allowing to calculate the allowable temperature change rates of pressure components were based,was the quasi- steady state of the temperature field in the simple shaped component,such as a slab,cylindrical or spherical wall. 展开更多
关键词 pressure component thermal stress quasi-steady state optimum heating