This paper presents the model of a SVC (Static VAR Compensator) which is controlled externally by a PI (Proportional Integral) & PD (Proportional Differential) controllers for the improvements of voltage stabil...This paper presents the model of a SVC (Static VAR Compensator) which is controlled externally by a PI (Proportional Integral) & PD (Proportional Differential) controllers for the improvements of voltage stability and damping effect of an on line power system. Both controller parameters has been optimized by using Ziegler-Nichols close loop tuning method. Both single phase and three phase (L-L) faults have been considered in the research. In this paper, a power system network is considered which is simulated in the phasor simulation method & the network is simulated in four steps; without SVC, With SVC but no externally controlled, SVC with PI controller & SVC with PD controller. Simulation result shows that without SVC, the system parameters become unstable during faults. When SVC is imposed in the network, then system parameters become stable. Again, when SVC is controlled externally by PI & PD controllers, then system parameters becomes stable in faster way then without controller. It has been observed that the SVC ratings are only 50 MVA with controllers and 200 MVA without controllers. So, SVC with PI & PD controllers are more effective to enhance the voltage stability and increases power transmission capacity of a power system. The power system oscillations are also reduced with controllers in compared to that of without controllers. So with both controllers the system performance is greatly enhanced.展开更多
For the proportional directional valve controlled by two proportional solenoids, the normal control method(NCM) energizes only one solenoid at a time. The performance of the valve is greatly influenced by the nonlinea...For the proportional directional valve controlled by two proportional solenoids, the normal control method(NCM) energizes only one solenoid at a time. The performance of the valve is greatly influenced by the nonlinearity of the proportional solenoid, such as dead zone and low force gain with a small current, and this effect cannot be eliminated by a simple dead-zone current compensation. To avoid this disadvantage, we propose the differential control method(DCM). By employing DCM, the controller outputs differential signals to simultaneously energize both solenoids of the proportional valve, and the operating point is found by analyzing the force output of the two solenoids to make a minimum variation of the current force gain. The comparisons of the valve response characteristics are made between NCM and DCM by nonlinear dynamic simulation and experiments. Simulation and experimental results show that by using DCM, the frequency response of the valve is greatly enhanced, especially when the input is small, which means that the dynamic characteristics of the proportional valve are improved.展开更多
为了提高某随动系统的主要性能指标,根据机电一体化技术的发展趋势,现采用单芯片控制器ADM C 330+IGBT驱动模块+直流电机的随动系统模式取代原有电子管放大器(包括反馈部分)+放大电机+直流电机的模式,并运用速度并联比例微分(PD)反馈方...为了提高某随动系统的主要性能指标,根据机电一体化技术的发展趋势,现采用单芯片控制器ADM C 330+IGBT驱动模块+直流电机的随动系统模式取代原有电子管放大器(包括反馈部分)+放大电机+直流电机的模式,并运用速度并联比例微分(PD)反馈方法,对随动系统的核心部分——控制与驱动部分进行改造.经过大量分析、试验证明,完全满足实际的需要,取得了良好的效果.展开更多
文摘This paper presents the model of a SVC (Static VAR Compensator) which is controlled externally by a PI (Proportional Integral) & PD (Proportional Differential) controllers for the improvements of voltage stability and damping effect of an on line power system. Both controller parameters has been optimized by using Ziegler-Nichols close loop tuning method. Both single phase and three phase (L-L) faults have been considered in the research. In this paper, a power system network is considered which is simulated in the phasor simulation method & the network is simulated in four steps; without SVC, With SVC but no externally controlled, SVC with PI controller & SVC with PD controller. Simulation result shows that without SVC, the system parameters become unstable during faults. When SVC is imposed in the network, then system parameters become stable. Again, when SVC is controlled externally by PI & PD controllers, then system parameters becomes stable in faster way then without controller. It has been observed that the SVC ratings are only 50 MVA with controllers and 200 MVA without controllers. So, SVC with PI & PD controllers are more effective to enhance the voltage stability and increases power transmission capacity of a power system. The power system oscillations are also reduced with controllers in compared to that of without controllers. So with both controllers the system performance is greatly enhanced.
基金Project supported by the National Natural Science Foundation of China(No.51221004)the Program for Zhejiang Leading Team of S&T Innovation(No.2010R50036)
文摘For the proportional directional valve controlled by two proportional solenoids, the normal control method(NCM) energizes only one solenoid at a time. The performance of the valve is greatly influenced by the nonlinearity of the proportional solenoid, such as dead zone and low force gain with a small current, and this effect cannot be eliminated by a simple dead-zone current compensation. To avoid this disadvantage, we propose the differential control method(DCM). By employing DCM, the controller outputs differential signals to simultaneously energize both solenoids of the proportional valve, and the operating point is found by analyzing the force output of the two solenoids to make a minimum variation of the current force gain. The comparisons of the valve response characteristics are made between NCM and DCM by nonlinear dynamic simulation and experiments. Simulation and experimental results show that by using DCM, the frequency response of the valve is greatly enhanced, especially when the input is small, which means that the dynamic characteristics of the proportional valve are improved.
文摘为了提高某随动系统的主要性能指标,根据机电一体化技术的发展趋势,现采用单芯片控制器ADM C 330+IGBT驱动模块+直流电机的随动系统模式取代原有电子管放大器(包括反馈部分)+放大电机+直流电机的模式,并运用速度并联比例微分(PD)反馈方法,对随动系统的核心部分——控制与驱动部分进行改造.经过大量分析、试验证明,完全满足实际的需要,取得了良好的效果.