期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Development of data acquisition and over-current protection systems for a suppressor-grid current with a neutral-beam ion source
1
作者 刘伟 胡纯栋 +5 位作者 刘胜 宋士花 汪金新 王艳 赵远哲 梁立振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期154-158,共5页
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin... Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission. 展开更多
关键词 neutral beam injection high-current ion source suppression grid current data acquisition and protection system
下载PDF
Discussion on Cathodic Protection of HZ 21-1 Platform
2
作者 Chen Lisheng Engineer, Nanhai East Oil Corporation. CNOOC, 510240 Guangzhou 《China Ocean Engineering》 SCIE EI 1992年第2期243-250,共8页
The environmental conditions around the first offshore HZ 21- 1 steel wellhead platform in the South China Sea are characterized by deep water, frequent typhoons, rough waves, high water temperature, severely corrosiv... The environmental conditions around the first offshore HZ 21- 1 steel wellhead platform in the South China Sea are characterized by deep water, frequent typhoons, rough waves, high water temperature, severely corrosive seawater, and thick fouling organism attachments. The design and effectiveness of galvanic anode protection system are presented, and several methods are described, which are the calculation method of the protective current density considering the variation of water depth, the method of determining protection parameters considering various factors, the arrangement of anodes based on potential distribution and current requirements at different water depths, and the method of anode installation. Finally the effect of the accuracy of selected cathodic protection parameters on the economic benefits of offshore projects is also discussed.. 展开更多
关键词 offshore platform seawater corrosion cathodic protection galvanic anode protective current density
下载PDF
Hybrid Control Strategy for Matrix Converter Fed Wind Energy Conversion System
3
作者 Jamna Ayadathil Jamuna Venkatesan 《Circuits and Systems》 2016年第10期3038-3053,共16页
In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence i... In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence it is necessary to design a system that regulates output parameters, such as voltage and frequency, and thereby provides a constant voltage and frequency output from the wind energy conversion system. Matrix converter is used in the proposed solution as the main power conditioner as a more efficient alternative when compared to traditional back-back converter structure. To control the output voltage, a vector modulation based refined control structure is used. A power tracker is included to maximize the mechanical output power of the turbine. Over current protection and clamp circuit input protection have been introduced to protect the system from over current. It reduces the spikes generated at the output of the converter. The designed system is capable of supplying an output voltage of constant frequency and amplitude within the expected ranges of input during the operation. The matrix converter control using direct modulation method, modified Venturini modulation method and vector modulation method was simulated, the results were compared and it was inferred that vector modulation method was superior to the other two methods. With the proposed technique, voltage transfer ratio and harmonic profile have been improved compared to the other two modulation techniques. The behaviour of the system is corroborated by MATLAB Simulink, and hardware is realized using an FPGA controller. Experimental results are found to be matching with the simulation results. 展开更多
关键词 Hybrid Control Strategy Wind Energy Conversion System Three Phase Matrix Converter Space Vector Modulation Over current/Clamp Circuit Protection FPGA Controller
下载PDF
A novel complex current ratio-based technique for transmission line protection 被引量:2
4
作者 Suryanarayana Gangolu Saumendra Sarangi 《Protection and Control of Modern Power Systems》 2020年第1期259-267,共9页
With respect to sensitivity,selectivity and speed of operation,the current differential scheme is a better way to protect transmission lines than overcurrent and distance-based schemes.However,the protection scheme ca... With respect to sensitivity,selectivity and speed of operation,the current differential scheme is a better way to protect transmission lines than overcurrent and distance-based schemes.However,the protection scheme can be severely influenced by the Line Charging Capacitive Current(LCCC)with increased voltage level and Current Transformer(CT)saturation under external close-in faults.This paper presents a new UHV/EHV current-based protection scheme using the ratio of phasor summation of the two-end currents to the local end current,instead of summation of the two-end currents,to discriminate the internal faults.The accuracy and effectiveness of the proposed protection technique are tested on the 110 kV Western System Coordinating Council(WSCC)9-bus system using PSCAD/MATLAB.The simulation results confirm the reliable operation of the proposed scheme during internal/external faults and its independence from fault location,fault resistance,type of fault,and variations in source impedance.Finally,the effectiveness of the proposed scheme is also verified with faults during power swing and in series compensated lines. 展开更多
关键词 current differential protection Line charging capacitive current CT saturation Fault discrimination Phasor summation of currents
原文传递
A micro-power LDO with piecewise voltage foldback current limit protection 被引量:1
5
作者 魏海龙 刘佑宝 +1 位作者 郭仲杰 廖雪 《Journal of Semiconductors》 EI CAS CSCD 2012年第11期121-125,共5页
To achieve a constant current limit,low power consumption and high driving capability,a micro-power LDO with a piecewise voltage-foldback current-limit circuit is presented.The current-limit threshold is dynamically a... To achieve a constant current limit,low power consumption and high driving capability,a micro-power LDO with a piecewise voltage-foldback current-limit circuit is presented.The current-limit threshold is dynamically adjusted to achieve a maximum driving capability and lower quiescent current of only 300 nA.To increase the loop stability of the proposed LDO,a high impedance transconductance buffer under a micro quiescent current is designed for splitting the pole that exists at the gate of the pass transistor to the dominant pole,and a zero is designed for the purpose of the second pole phase compensation.The proposed LDO is fabricated in a BiCMOS process. The measurement results show that the short-circuit current of the LDO is 190 mA,the constant limit current under a high drop-out voltage is 440 mA,and the maximum load current under a low drop-out voltage is up to 800 mA. In addition,the quiescent current of the LDO is only 7μA,the load regulation is about 0.56%on full scale,the line regulation is about 0.012%/V,the PSRR at 120 Hz is 58 dB and the drop-out voltage is only 70 mV when the load current is 250 mA. 展开更多
关键词 power protection voltage foldback current limit micro-power LDO
原文传递
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
6
作者 Victor A.F.Almeida Glauco N.Taranto José M.T.Marinho 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1269-1278,共10页
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.... This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations. 展开更多
关键词 Converter-interfaced generator three-phase model power system protection negative-sequence current injection negative-sequence current protection unbalanced fault three-phase root-mean-square(RMS)dynamic simulation
原文传递
A review of the protection for the multi-terminal VSC-HVDC grid 被引量:23
7
作者 Bin Li Jiawei He +1 位作者 Ye Li Botong Li 《Protection and Control of Modern Power Systems》 2019年第1期251-261,共11页
The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this pap... The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid. 展开更多
关键词 Multi-terminal VSC-HVDC grid Traveling-wave based protection Transient-variable based protection Directional pilot protection current differential protection
原文传递
IEC61850 standard-based harmonic blocking scheme for power transformers 被引量:9
8
作者 Senthil Krishnamurthy Bwandakassy Elenga Baningobera 《Protection and Control of Modern Power Systems》 2019年第1期123-137,共15页
Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks th... Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay tripping during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have harmonic restraint element and trip the overcurrent relay during the inrush conditions. Therefore, major contribution of this research work is the developed harmonic blocking scheme for transformer which uses element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit from tripping during the transformer magnetizing inrush current conditions. The simulation results proved that IEC61850 standard-based protection scheme is faster than the hardwired signals. Therefore, the speed and reliability of the transformer scheme are improved using the IEC61850 standard-based GOOSE applications. 展开更多
关键词 Transformer protection Overcurrent protection Digital protection scheme current differential protection Transformer magnetizing inrush current Harmonic blocking IEC 61850 GOOSE message
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部