Real-time and on-line monitoring volatile organic compounds(VOCs) are valuable for real-time evalua- ting air quality and monitoring the key source of pollution. A self-developed proton transfer reaction-mass spectr...Real-time and on-line monitoring volatile organic compounds(VOCs) are valuable for real-time evalua- ting air quality and monitoring the key source of pollution. A self-developed proton transfer reaction-mass spectro- meter(PTR-MS) was constructed and applied to on-line monitoring trace VOCs in ambient air in Hefei, China. With the help of a self-developed catalytic converter, the background signal of the instrument was detected and the stability of the instrument was evaluated. The relative standard deviation of signal at m/z 21 was only 0.74% and the detection limit of PTR-MS was 97 part per trillion(97x 10-12, volume ratio). As a case of the air monitoring in Hefei, the am- bient air at Dongpu reservoir spot was on-line monitored for 13 d with our self-developed PTR-MS. Meanwhile, a solid-phase micro-extraction(SPME) technique coupled to gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS) was also used for the off-line detection of the air. The results show that our self-developed PTR-MS can be used for the on-line and long-term monitoring of VOCs in air at part per trillion level, and the change trend of VOCs concentration monitored with PTR-MS was consistent with that detected with the conventional SPME-GC-MS. This self-developed PTR-MS can fully satisfy the requirements of air quality monitoring and real-time monitoring of the key pollution sources.展开更多
研制可快速、在线分析挥发性有机物(volatile organic compounds,VOCs)的质谱仪器是现代气态有机质谱的重要发展方向。本研究自行研制了小型高性能质子转移反应飞行时间质谱仪(proton transfer reaction time of flight mass spectromet...研制可快速、在线分析挥发性有机物(volatile organic compounds,VOCs)的质谱仪器是现代气态有机质谱的重要发展方向。本研究自行研制了小型高性能质子转移反应飞行时间质谱仪(proton transfer reaction time of flight mass spectrometry,PTR-TOF MS),仪器采用结构简单可靠的空心阴极放电源作为水蒸气电离源,以产生水合质子;线性漂移管作为分子离子反应管。该离子源产生的水合离子纯度高,为水合离子与VOCs的分子离子反应提供可控的反应条件。传输接口部分使用射频四极杆作为离子导向装置,以提高离子传输效率;配合小尺寸飞行时间质量分析器,兼顾仪器的灵敏度与分辨率。质子转移反应的测定原理使该仪器可以分析除少数烷烃外的绝大多数VOCs,同时分析过程不受空气组分的影响。分子离子峰为主的产物离子形式使谱图便于解析,适合高通量分析。测试结果表明,该仪器在m/z 115处全高半峰宽(full width half maximum,FWHM)分辨率优于2500,对丙酮、苯、甲苯的检出限在6×10^(-12)~9.6×10^(-11) mol/mol之间。将该仪器应用于人体呼吸气的成分分析,取得了良好的结果。展开更多
以《大气污染物综合排放标准))(GB 16297-1996)中有机物的实时在线测量为目的,对自行研制的质子转移反应质谱(proton transfer reaction mass spectrometry,PTR-MS)装置的参数进行了优化和测量。利用高纯N_2稀释的单一有机物PTR-MS测量...以《大气污染物综合排放标准))(GB 16297-1996)中有机物的实时在线测量为目的,对自行研制的质子转移反应质谱(proton transfer reaction mass spectrometry,PTR-MS)装置的参数进行了优化和测量。利用高纯N_2稀释的单一有机物PTR-MS测量结果表明,在E/N=144 Td条件下,质子化的有机物离子为主要的产物离子峰,没有明显的碎片离子存在。测试了进样系统中催化转化装置的性能,给出了11种挥发性有机物的探测灵敏度和检测下限,讨论了PTR-MS的测量精度。测试结果表明,自行研制的PTR-MS能够实时在线监测《大气污染物综合排放标准》中规定的有机污染物。展开更多
基金Supported by the National Natural Science Foundation of China(Nos.21477132, 21577145), the National Key Technology Research and Development Program of China(No.2015BAI01B04), the National Key Research Program of China (No.2016YFC0200200), the Innovative Program of Development Foundation of Hefei Center for Physical Science and Technology of China(No.2014FXCX007) and the Functional Development Program of Instrument and Equipment in Chinese Academy of Sciences.
文摘Real-time and on-line monitoring volatile organic compounds(VOCs) are valuable for real-time evalua- ting air quality and monitoring the key source of pollution. A self-developed proton transfer reaction-mass spectro- meter(PTR-MS) was constructed and applied to on-line monitoring trace VOCs in ambient air in Hefei, China. With the help of a self-developed catalytic converter, the background signal of the instrument was detected and the stability of the instrument was evaluated. The relative standard deviation of signal at m/z 21 was only 0.74% and the detection limit of PTR-MS was 97 part per trillion(97x 10-12, volume ratio). As a case of the air monitoring in Hefei, the am- bient air at Dongpu reservoir spot was on-line monitored for 13 d with our self-developed PTR-MS. Meanwhile, a solid-phase micro-extraction(SPME) technique coupled to gas chromatography-mass spectrometry/mass spectrometry (GC-MS/MS) was also used for the off-line detection of the air. The results show that our self-developed PTR-MS can be used for the on-line and long-term monitoring of VOCs in air at part per trillion level, and the change trend of VOCs concentration monitored with PTR-MS was consistent with that detected with the conventional SPME-GC-MS. This self-developed PTR-MS can fully satisfy the requirements of air quality monitoring and real-time monitoring of the key pollution sources.
文摘研制可快速、在线分析挥发性有机物(volatile organic compounds,VOCs)的质谱仪器是现代气态有机质谱的重要发展方向。本研究自行研制了小型高性能质子转移反应飞行时间质谱仪(proton transfer reaction time of flight mass spectrometry,PTR-TOF MS),仪器采用结构简单可靠的空心阴极放电源作为水蒸气电离源,以产生水合质子;线性漂移管作为分子离子反应管。该离子源产生的水合离子纯度高,为水合离子与VOCs的分子离子反应提供可控的反应条件。传输接口部分使用射频四极杆作为离子导向装置,以提高离子传输效率;配合小尺寸飞行时间质量分析器,兼顾仪器的灵敏度与分辨率。质子转移反应的测定原理使该仪器可以分析除少数烷烃外的绝大多数VOCs,同时分析过程不受空气组分的影响。分子离子峰为主的产物离子形式使谱图便于解析,适合高通量分析。测试结果表明,该仪器在m/z 115处全高半峰宽(full width half maximum,FWHM)分辨率优于2500,对丙酮、苯、甲苯的检出限在6×10^(-12)~9.6×10^(-11) mol/mol之间。将该仪器应用于人体呼吸气的成分分析,取得了良好的结果。
文摘以《大气污染物综合排放标准))(GB 16297-1996)中有机物的实时在线测量为目的,对自行研制的质子转移反应质谱(proton transfer reaction mass spectrometry,PTR-MS)装置的参数进行了优化和测量。利用高纯N_2稀释的单一有机物PTR-MS测量结果表明,在E/N=144 Td条件下,质子化的有机物离子为主要的产物离子峰,没有明显的碎片离子存在。测试了进样系统中催化转化装置的性能,给出了11种挥发性有机物的探测灵敏度和检测下限,讨论了PTR-MS的测量精度。测试结果表明,自行研制的PTR-MS能够实时在线监测《大气污染物综合排放标准》中规定的有机污染物。