The paper describes an experimental study of the characteristics of a pulse-modulated radiofrequency(RF)discharge sustained at low pressures,typical of the operating modes of RF gridded ion sources.The motivation for ...The paper describes an experimental study of the characteristics of a pulse-modulated radiofrequency(RF)discharge sustained at low pressures,typical of the operating modes of RF gridded ion sources.The motivation for the study is the question of whether the RF pulsemodulated mode can increase the efficiency of the ion source.The ion current values extracted from an RF inductive ion source operating in continuous and pulse-modulated modes were compared.The experimental data were also compared with the parameter calculations based on a0D numerical model of the discharge.The measurements showed that the pulse-modulated operation mode of the RF ion source had a noticeable advantage when the power of the RF generator was 140 W or lower.However,as the generator power increased,the advantage was lost because the pulse-modulated operation mode,having a higher RF power instant value,entered the region of existence sooner than the continuous mode,where the ion production cost begins to grow with RF power.展开更多
In this paper, we report a high power long-pulse single-frequency all-fiber amplifier at 1064 nm with near-diffraction-limited beam quality based on a polarization-maintaining tapered Yb-doped fiber (T-YDF). By applyi...In this paper, we report a high power long-pulse single-frequency all-fiber amplifier at 1064 nm with near-diffraction-limited beam quality based on a polarization-maintaining tapered Yb-doped fiber (T-YDF). By applying square wave pulse modulation to the diodes, with a frequency of 50 Hz and a pulse width of 668 μs, the peak power of the output laser reached 257 W with an average power of 8.65 W, linewidth of 10.6 kHz and M<sup>2</sup> < 1.5. .展开更多
Variable frequency,a new pattern of pulse hydraulic fracturing,is presented for improving permeability in coal seam.A variable frequency pulse hydraulic fracturing testing system was built,the mould with triaxial load...Variable frequency,a new pattern of pulse hydraulic fracturing,is presented for improving permeability in coal seam.A variable frequency pulse hydraulic fracturing testing system was built,the mould with triaxial loading was developed.Based on the monitor methods of pressure sensor and acoustic emission,the trials of two patterns of pulse hydraulic fracturing of single frequency and variable frequency were carried out,and at last fracturing mechanism was analyzed.The results show that the effect of variable frequency on fracture extension is better than that of single frequency based on the analysis of macroscopic figures and AE.And the shortage of single frequency is somewhat remedied when the frequency is variable.Under variable frequency,the pressure process can be divided into three stages:low frequency band,pressure stability band and high frequency band,and rupture pressure of the sample is smaller than that of the condition of single frequency.Based on the Miner fatigue theory,the effect of different loading sequences on sample rupture is discussed and the results show that it is better to select the sequence of low frequency at first and then high frequency.Our achievements can give a basis for the improvement and optimization of the pulse hydraulic fracturing technology.展开更多
In this paper, the linear propagation characteristics of the exponential optical pulse with initial linear and nonlinear frequency chirp are numerically studied in a single mode fibre for β2 〈 0. It can be found tha...In this paper, the linear propagation characteristics of the exponential optical pulse with initial linear and nonlinear frequency chirp are numerically studied in a single mode fibre for β2 〈 0. It can be found that the temporal full width at half maximum and time-bandwidth product of exponential pulse monotonically increase with the increase of propagation distance and decrease with the increase of linear chirp C for C 〈 0.5, go through an initial decreasing stage near ζ= 1, then increase with the increase of propagation distance and linear chirp C for C 〉 0.5. The broadening of pulses with negative chirp is faster than that with positive chirp. The exponential pulse with linear chirp gradually evolves into a near-Gaussian pulse. The effect of nonlinear chirp on waveform of the pulse is much greater than that of linear chirp. The temporal waveform breaking of exponential pulse with nonlinear chirp is first observed in linear propagation. Furthermore, the expressions of the spectral width and time-bandwidth product of the exponential optical pulse with the frequency chirp are given by use of the numerical analysis method.展开更多
In view of the unstable welding process of Tri-Arc DE,surfacing test with Q235 steel plate was completed with the help of the self-built high-speed camera and waveform synchronous acquisition system using the Tri-Arc ...In view of the unstable welding process of Tri-Arc DE,surfacing test with Q235 steel plate was completed with the help of the self-built high-speed camera and waveform synchronous acquisition system using the Tri-Arc DE technology. The effects of pulsed M-Arc frequency on Tri-Arc DE droplet transfer and weld formation were analyzed. The results show that while the gradual increase of pulse frequency,the droplet transfer frequency gradually decreases,which is followed by several drops per pulse,one drop per pulse,and one drop within several pulses. The most ideal transfer form is one drop per pulse,of which the welding process is the most stable,and the quality of weld formation is the most satisfied.展开更多
Micro arc oxidation(MAO)coatings were formed on magnesium alloy AZ31B to improve the corrosion resistance using environmental friendly electrolyte solution under single-polar pulse power supply.The effect of electrica...Micro arc oxidation(MAO)coatings were formed on magnesium alloy AZ31B to improve the corrosion resistance using environmental friendly electrolyte solution under single-polar pulse power supply.The effect of electrical parameters of pulse frequency on the coating performance was studied at frequencies of 2.5 Hz,25 Hz and 250 Hz.The coating performance at different frequencies was characterized by scanning electron microscopy(SEM),energy-dispersive X-ray spectroscopy(EDS)and potentiodynamic polarization testing method.It was found that the corrosion resistance of the MAO coatings was improved when increasing the pulse frequencies from 2.5 Hz to 250 Hz.The corrosion current in 250 Hz case decreased by three orders of magnitude as compared with bare Mg alloy and the corrosion impedance also increased remarkably,means significantly enhanced corrosion resistance than bare Mg alloy.The results give us more insight in the optimization of electrical parameters to improve the MAO coating performance.The MAO technology is attractive for application on magnesium and other light alloys for surface protection in automotive and space industries.展开更多
We report on the generation of optical pulses with a nearly one octave-spanning spectrum ranging from 1300 nm to2500 nm at 1 kHz repetition rate, which are based on intra-pulse difference frequency generation(DFG) in ...We report on the generation of optical pulses with a nearly one octave-spanning spectrum ranging from 1300 nm to2500 nm at 1 kHz repetition rate, which are based on intra-pulse difference frequency generation(DFG) in β-barium borate crystal(β-BBO) and passively carrier-envelope-phase(CEP) stabilized. The DFG is induced by few-cycle pulses initiated from spectral broadening in multiple thin plates driven by a Ti: sapphire chirped-pulse amplifier. Furthermore, a numerical simulation is developed to estimate the conversion efficiency and output spectrum of the DFG. Our results show that the pulses from the DFG have the potential for seeding intense mid-infrared(MIR) laser generation and amplification to study strong-field physics and attosecond science.展开更多
Atmospheric cascade discharges with pulsed discharge and radio frequency(RF)discharge were experimentally investigated by the temporal evolution of discharge spatial profile and intensity.The indium tin oxide(ITO)coat...Atmospheric cascade discharges with pulsed discharge and radio frequency(RF)discharge were experimentally investigated by the temporal evolution of discharge spatial profile and intensity.The indium tin oxide(ITO)coated glass was employed as the transparent electrode to capture the discharge distribution above the electrode surface.It is demonstrated that in the pulsed discharge with dielectric barrier,the first discharge at the rising edge of pulse voltage is uniformly ignited and then forms an expanding plasma ring on the ITO electrode surface,which shrinks to the same diameter as that of bare stainless steel electrode with the generation of second discharge at the falling edge of pulse voltage.The discharge profiles along the electrode surface and discharge gap of the successive RF discharge are dependent on the intensity and spatial distribution of residual plasma species generated by the pulsed discharge,which is determined by the time interval between the pulsed discharge and RF discharge.It is demonstrated that the residual plasma species before the RF discharge ignition help to achieve the stable operation of RF discharge with elevated intensity.展开更多
A high frequency pulse power source for TIG welding is developed. The structure of two powers is adopted. The by pass circuit effectively eliminates the effect of the cable equivalent inductance. The maximum frequenc...A high frequency pulse power source for TIG welding is developed. The structure of two powers is adopted. The by pass circuit effectively eliminates the effect of the cable equivalent inductance. The maximum frequency of the output pulse current reaches to 16 kHz . The base current and the peak current can be regulated separately.展开更多
AA 2219-0 Al-Cu alloy single bead welds were obtained by hybrid ultrahigh frequency pulse variable polarity gas tungsten arc welding (HPVP-GTAW) process with pulse frequency varying from 25 kHz to 70 kHz. Weld hardn...AA 2219-0 Al-Cu alloy single bead welds were obtained by hybrid ultrahigh frequency pulse variable polarity gas tungsten arc welding (HPVP-GTAW) process with pulse frequency varying from 25 kHz to 70 kHz. Weld hardness characteristics which mainly depicted by microhardness and its gradient were investigated systematically. The results show that pulse frequency has a great effect on the hardness characteristics. The weld zone microhardness and its gradient with different pulse frequency present an evident fluctuant trend. The fluctuation of gradient is slight, illustrating that the mierostructure is uniform with pulse frequcncy varied from 35 kHz to 60 kHz. The fusion zone microhardness and its gradient foUow the similar trends but fluetuate greatly. Maximum value of gradient appears around the fusion boundary due to the coarse and non- uniform microstrueture. The maximum gradient at 60 kHz is only 25.5 % of that at 45 kHz. According to the study, the best hardness characteristics are achieved at 60 kHz frequency.展开更多
The resistance between any two lattice points in an infinite,centered-triangular lattice of equal resistors is determined using the lattice Green function method.It is shown that the two-point resistance on the center...The resistance between any two lattice points in an infinite,centered-triangular lattice of equal resistors is determined using the lattice Green function method.It is shown that the two-point resistance on the centeredtriangular lattice is expressed in terms of the resistance of a triangular lattice.Some exact values for the resistance near the origin of the lattice are presented.For large separation between lattice points the asymptotic forms of the resistance are calculated.展开更多
A new type of window called combined window is designed to get higher Ratio of Mainlobe to Sidelobes (RMS) and lower Mainlobe Widening Factor (MWF). Simulation results prove that the new window can solve the contradic...A new type of window called combined window is designed to get higher Ratio of Mainlobe to Sidelobes (RMS) and lower Mainlobe Widening Factor (MWF). Simulation results prove that the new window can solve the contradiction between RMS and MWF better than classic windows.展开更多
The attitude control problem of the kinetic kill vehicle is studied in this work. A new mathematical model of the kinetic kill vehicle is proposed, the linear quadratic regulator technique is used to design the optima...The attitude control problem of the kinetic kill vehicle is studied in this work. A new mathematical model of the kinetic kill vehicle is proposed, the linear quadratic regulator technique is used to design the optimal attitude controller, and the pulse-width pulse-frequency modulator is used to shape the continuous control command to pulse or on-off signals to meet the requirements of the reaction thrusters. The methods to select the appropriate parameters of pulse-width pulse-frequency are presented in detail. Numerical simulations show that the performance of the LQR/PWPF approach can achieve good control performance such as pseudo-linear operation, high accuracy, and fast enough tracking speed.展开更多
AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: Th...AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.展开更多
A new type of variable polarity welding power modulated with high-frequency pulse current is developed. Series of high-frequency pulse current is superimposed on direct-current-electrode-negative (DCEN), which can i...A new type of variable polarity welding power modulated with high-frequency pulse current is developed. Series of high-frequency pulse current is superimposed on direct-current-electrode-negative (DCEN), which can improve the crystallization process in the weld bead as a result of the electromagnetic force generated by pulse current. Digital signal processor (DSP) is used to realize the closed-loop control of the first inverter, variable polarity output of the second inverter and high-frequency pulse current superposition.展开更多
Thin plates of 21% Cr ferritic stainless steel welded by pulsed gas tungsten arc welding at different pulse frequencies were investigated for the microstructure characteristics and hardness behavior.The welds containe...Thin plates of 21% Cr ferritic stainless steel welded by pulsed gas tungsten arc welding at different pulse frequencies were investigated for the microstructure characteristics and hardness behavior.The welds contained columnar grains in the outer part and fine equiaxed grains in the central region due to the pulsed process.展开更多
Many conventional methods of testing strong and pulsed electromagnetic fields,the ones used in radars for example,had deficiencies due to the difficulty in obtaining simultaneous information about the electromagnetic ...Many conventional methods of testing strong and pulsed electromagnetic fields,the ones used in radars for example,had deficiencies due to the difficulty in obtaining simultaneous information about the electromagnetic field's peak both in the time domain and in the frequency domain.With regard to this problem,after analyzing the time-domain and the frequency-domain characteristics of radar pulsed signals,we propose a new time-frequency combination test method based on the correction of the test parameters,as well as its correction method at different bandwidths.The test method is applied in a quick test of a high-power pulsed radar signal,and the corrected results have error less than 1 dB in both the time domain and the frequency domain,which indicates that the proposed time-frequency combined method is effective in testing strong and pulsed electromagnetic fields.展开更多
Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal d...Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal differentiation of BMSCs. Low-frequency PEMF can induce the neuronal differentiation of BMSCs in the absence of nerve growth factors. This study was designed to investigate the effects of low-frequency PEMF pretreatment on the proliferation and function of BMSCs and the effects of low-frequency PEMF pre-treated BMSCs on the regeneration of injured peripheral nerve using in vitro and in vivo experiments.In in vitro experiments, quantitative DNA analysis was performed to determine the proliferation of BMSCs, and reverse transcription-polymerase chain reaction was performed to detect S100 (Schwann cell marker), glial fibrillary acidic protein (astrocyte marker), and brain-derived neurotrophic factor and nerve growth factor (neurotrophic factors) mRNA expression. In the in vivo experiments, rat models of crush-injured mental nerve established using clamp method were randomly injected with low-frequency PEMF pretreated BMSCs, unpretreated BMSCs or PBS at the injury site (1 × 106 cells). DiI-labeled BMSCs injected at the injury site were counted under the fluorescence microscope to determine cell survival. One or two weeks after cell injection, functional recovery of the injured nerve was assessed using the sensory test with von Frey filaments. Two weeks after cell injection, axonal regeneration was evaluated using histomorphometric analysis and retrograde labeling of trigeminal ganglion neurons. In vitro experiment results revealed that low-frequency PEMF pretreated BMSCs proliferated faster and had greater mRNA expression of growth factors than unpretreated BMSCs. In vivo experiment results revealed that compared with injection of unpretreated BMSCs, injection of low-frequency PEMF pretreated BMSCs led to higher myelinated axon count and axon density and more DiI-labeled neurons in the trigeminal ganglia, contributing to rapider functional recovery of injured mental nerve. These findings suggest that low-frequency PEMF pretreatment is a promising approach to enhance the efficacy of cell therapy for peripheral nerve injury repair.展开更多
An electromagnetic coupling mathematical model is established by finite element method and is verified by the contrastive experiments of copper matrix Ni-TiN cylindrical coating electrode,copper electrode and Cu50 W e...An electromagnetic coupling mathematical model is established by finite element method and is verified by the contrastive experiments of copper matrix Ni-TiN cylindrical coating electrode,copper electrode and Cu50 W electrode.The wear mechanism of Ni-TiN/Cu composite electrode in the case of high-frequency pulse current is studied,and the influence of the fluctuation frequency of discharge current on electrode wear in micro-EDM is found out.Compared with the electrode made from homogeneous material,the high frequency electromagnetic properties of Ni-TiN composite layer can be used effectively to inhibit the effect of high frequency pulse on the electrode and improve the distribution trend of current density.展开更多
文摘The paper describes an experimental study of the characteristics of a pulse-modulated radiofrequency(RF)discharge sustained at low pressures,typical of the operating modes of RF gridded ion sources.The motivation for the study is the question of whether the RF pulsemodulated mode can increase the efficiency of the ion source.The ion current values extracted from an RF inductive ion source operating in continuous and pulse-modulated modes were compared.The experimental data were also compared with the parameter calculations based on a0D numerical model of the discharge.The measurements showed that the pulse-modulated operation mode of the RF ion source had a noticeable advantage when the power of the RF generator was 140 W or lower.However,as the generator power increased,the advantage was lost because the pulse-modulated operation mode,having a higher RF power instant value,entered the region of existence sooner than the continuous mode,where the ion production cost begins to grow with RF power.
文摘In this paper, we report a high power long-pulse single-frequency all-fiber amplifier at 1064 nm with near-diffraction-limited beam quality based on a polarization-maintaining tapered Yb-doped fiber (T-YDF). By applying square wave pulse modulation to the diodes, with a frequency of 50 Hz and a pulse width of 668 μs, the peak power of the output laser reached 257 W with an average power of 8.65 W, linewidth of 10.6 kHz and M<sup>2</sup> < 1.5. .
基金Financial support for this work,provided by the National Basic Research Program of China(No.2011CB201205)the Natural Science Foundation of Jiangsu Province(No.BK2012571)+1 种基金the Program for New Century Excellent Talents in University(No.NCET-120959)the"Qing-Lan Project"and Collegial Graduate Research and Innovation Program of Jiangsu Province(No.CXZZ13_0955)
文摘Variable frequency,a new pattern of pulse hydraulic fracturing,is presented for improving permeability in coal seam.A variable frequency pulse hydraulic fracturing testing system was built,the mould with triaxial loading was developed.Based on the monitor methods of pressure sensor and acoustic emission,the trials of two patterns of pulse hydraulic fracturing of single frequency and variable frequency were carried out,and at last fracturing mechanism was analyzed.The results show that the effect of variable frequency on fracture extension is better than that of single frequency based on the analysis of macroscopic figures and AE.And the shortage of single frequency is somewhat remedied when the frequency is variable.Under variable frequency,the pressure process can be divided into three stages:low frequency band,pressure stability band and high frequency band,and rupture pressure of the sample is smaller than that of the condition of single frequency.Based on the Miner fatigue theory,the effect of different loading sequences on sample rupture is discussed and the results show that it is better to select the sequence of low frequency at first and then high frequency.Our achievements can give a basis for the improvement and optimization of the pulse hydraulic fracturing technology.
文摘In this paper, the linear propagation characteristics of the exponential optical pulse with initial linear and nonlinear frequency chirp are numerically studied in a single mode fibre for β2 〈 0. It can be found that the temporal full width at half maximum and time-bandwidth product of exponential pulse monotonically increase with the increase of propagation distance and decrease with the increase of linear chirp C for C 〈 0.5, go through an initial decreasing stage near ζ= 1, then increase with the increase of propagation distance and linear chirp C for C 〉 0.5. The broadening of pulses with negative chirp is faster than that with positive chirp. The exponential pulse with linear chirp gradually evolves into a near-Gaussian pulse. The effect of nonlinear chirp on waveform of the pulse is much greater than that of linear chirp. The temporal waveform breaking of exponential pulse with nonlinear chirp is first observed in linear propagation. Furthermore, the expressions of the spectral width and time-bandwidth product of the exponential optical pulse with the frequency chirp are given by use of the numerical analysis method.
基金Project was supported by the National Natural Science Foundation of China(Grant No.U1733125)Natural Science Foundation of Tianjin(Grant No.18JCYBJC19100,18JCYJC18700)
文摘In view of the unstable welding process of Tri-Arc DE,surfacing test with Q235 steel plate was completed with the help of the self-built high-speed camera and waveform synchronous acquisition system using the Tri-Arc DE technology. The effects of pulsed M-Arc frequency on Tri-Arc DE droplet transfer and weld formation were analyzed. The results show that while the gradual increase of pulse frequency,the droplet transfer frequency gradually decreases,which is followed by several drops per pulse,one drop per pulse,and one drop within several pulses. The most ideal transfer form is one drop per pulse,of which the welding process is the most stable,and the quality of weld formation is the most satisfied.
基金This work performed by the author was financially sup-ported by Singapore Ministry of Education innovation Fund(MOE2010-IF-027).
文摘Micro arc oxidation(MAO)coatings were formed on magnesium alloy AZ31B to improve the corrosion resistance using environmental friendly electrolyte solution under single-polar pulse power supply.The effect of electrical parameters of pulse frequency on the coating performance was studied at frequencies of 2.5 Hz,25 Hz and 250 Hz.The coating performance at different frequencies was characterized by scanning electron microscopy(SEM),energy-dispersive X-ray spectroscopy(EDS)and potentiodynamic polarization testing method.It was found that the corrosion resistance of the MAO coatings was improved when increasing the pulse frequencies from 2.5 Hz to 250 Hz.The corrosion current in 250 Hz case decreased by three orders of magnitude as compared with bare Mg alloy and the corrosion impedance also increased remarkably,means significantly enhanced corrosion resistance than bare Mg alloy.The results give us more insight in the optimization of electrical parameters to improve the MAO coating performance.The MAO technology is attractive for application on magnesium and other light alloys for surface protection in automotive and space industries.
基金Project supported by the National Key R&D Program of China(Grant No.2017YFB0405202)the Major Program of the National Natural Science Foundation of China(Grant No.61690221)+1 种基金the Key Program of the National Natural Science Foundation of China(Grant No.11434016)the National Natural Science Foundation of China(Grant Nos.11574384 and 11674386)
文摘We report on the generation of optical pulses with a nearly one octave-spanning spectrum ranging from 1300 nm to2500 nm at 1 kHz repetition rate, which are based on intra-pulse difference frequency generation(DFG) in β-barium borate crystal(β-BBO) and passively carrier-envelope-phase(CEP) stabilized. The DFG is induced by few-cycle pulses initiated from spectral broadening in multiple thin plates driven by a Ti: sapphire chirped-pulse amplifier. Furthermore, a numerical simulation is developed to estimate the conversion efficiency and output spectrum of the DFG. Our results show that the pulses from the DFG have the potential for seeding intense mid-infrared(MIR) laser generation and amplification to study strong-field physics and attosecond science.
基金National Natural Science Foundation of China(Nos.11875104 and 11475043)open fund of Shanghai center for high performance fibers and composites(X12811901/012).
文摘Atmospheric cascade discharges with pulsed discharge and radio frequency(RF)discharge were experimentally investigated by the temporal evolution of discharge spatial profile and intensity.The indium tin oxide(ITO)coated glass was employed as the transparent electrode to capture the discharge distribution above the electrode surface.It is demonstrated that in the pulsed discharge with dielectric barrier,the first discharge at the rising edge of pulse voltage is uniformly ignited and then forms an expanding plasma ring on the ITO electrode surface,which shrinks to the same diameter as that of bare stainless steel electrode with the generation of second discharge at the falling edge of pulse voltage.The discharge profiles along the electrode surface and discharge gap of the successive RF discharge are dependent on the intensity and spatial distribution of residual plasma species generated by the pulsed discharge,which is determined by the time interval between the pulsed discharge and RF discharge.It is demonstrated that the residual plasma species before the RF discharge ignition help to achieve the stable operation of RF discharge with elevated intensity.
文摘A high frequency pulse power source for TIG welding is developed. The structure of two powers is adopted. The by pass circuit effectively eliminates the effect of the cable equivalent inductance. The maximum frequency of the output pulse current reaches to 16 kHz . The base current and the peak current can be regulated separately.
基金The research is supported by the National Natural Science Foundation of China (No. 51005011 ) the Fundamental Research Funds for the Central Universities.
文摘AA 2219-0 Al-Cu alloy single bead welds were obtained by hybrid ultrahigh frequency pulse variable polarity gas tungsten arc welding (HPVP-GTAW) process with pulse frequency varying from 25 kHz to 70 kHz. Weld hardness characteristics which mainly depicted by microhardness and its gradient were investigated systematically. The results show that pulse frequency has a great effect on the hardness characteristics. The weld zone microhardness and its gradient with different pulse frequency present an evident fluctuant trend. The fluctuation of gradient is slight, illustrating that the mierostructure is uniform with pulse frequcncy varied from 35 kHz to 60 kHz. The fusion zone microhardness and its gradient foUow the similar trends but fluetuate greatly. Maximum value of gradient appears around the fusion boundary due to the coarse and non- uniform microstrueture. The maximum gradient at 60 kHz is only 25.5 % of that at 45 kHz. According to the study, the best hardness characteristics are achieved at 60 kHz frequency.
基金Supported by the National Key Research and Development Program of China under Grant No 2016YFC1400902the National Natural Science Foundation of China under Grant Nos 61505230 and 61475170the Shanghai Natural Science Foundation under Grant No 15ZR1445000
文摘The resistance between any two lattice points in an infinite,centered-triangular lattice of equal resistors is determined using the lattice Green function method.It is shown that the two-point resistance on the centeredtriangular lattice is expressed in terms of the resistance of a triangular lattice.Some exact values for the resistance near the origin of the lattice are presented.For large separation between lattice points the asymptotic forms of the resistance are calculated.
文摘A new type of window called combined window is designed to get higher Ratio of Mainlobe to Sidelobes (RMS) and lower Mainlobe Widening Factor (MWF). Simulation results prove that the new window can solve the contradiction between RMS and MWF better than classic windows.
文摘The attitude control problem of the kinetic kill vehicle is studied in this work. A new mathematical model of the kinetic kill vehicle is proposed, the linear quadratic regulator technique is used to design the optimal attitude controller, and the pulse-width pulse-frequency modulator is used to shape the continuous control command to pulse or on-off signals to meet the requirements of the reaction thrusters. The methods to select the appropriate parameters of pulse-width pulse-frequency are presented in detail. Numerical simulations show that the performance of the LQR/PWPF approach can achieve good control performance such as pseudo-linear operation, high accuracy, and fast enough tracking speed.
基金The 2007 research fund of Wonkwang University and Wonkwang Clinical Research Institute
文摘AIM: To study the efficacy and the safety of laser lithotripsy without direct visual control by using a balloon catheter in patients with bile duct stones that could not be extracted by standard technique. METHODS: The seventeen patients (7 male and 10 female; mean age 67.8 years) with difficult common bile duct (CBD) stones were not amenable for conventional endoscopic maneuvers such as sphincterotomy and mechanical lithotripsy were included in this study. Laser wavelengths of 532 nm and 1064 nm as a double pulse were applied with pulse energy of 120 mJ. The laser fiber was advanced under fluoroscopic control through the ERCP balloon catheter. Laser lithotripsy was continued until the fragment size seemed to be less than 10 mm. Endoscopic extraction of the stones and fragments was performed with the use of the Dormia basket and balloon catheter. RESULTS: Bile duct clearance was achieved in 15 of 17 patients (88%). The mean number of treatment sessions was 1.7 ± 0.6. Endoscopic stone removal could not be achieved in 2 patients (7%). Adverse effects were noted in three patients (hemobilia, pancreatitis, and cholangitis). CONCLUSION: The Frequency Doubled Double Pulse Nd:YAG (FREDDY) laser may be an effective and safe technique in treatment of difficult bile duct stones.
文摘A new type of variable polarity welding power modulated with high-frequency pulse current is developed. Series of high-frequency pulse current is superimposed on direct-current-electrode-negative (DCEN), which can improve the crystallization process in the weld bead as a result of the electromagnetic force generated by pulse current. Digital signal processor (DSP) is used to realize the closed-loop control of the first inverter, variable polarity output of the second inverter and high-frequency pulse current superposition.
文摘Thin plates of 21% Cr ferritic stainless steel welded by pulsed gas tungsten arc welding at different pulse frequencies were investigated for the microstructure characteristics and hardness behavior.The welds contained columnar grains in the outer part and fine equiaxed grains in the central region due to the pulsed process.
文摘Many conventional methods of testing strong and pulsed electromagnetic fields,the ones used in radars for example,had deficiencies due to the difficulty in obtaining simultaneous information about the electromagnetic field's peak both in the time domain and in the frequency domain.With regard to this problem,after analyzing the time-domain and the frequency-domain characteristics of radar pulsed signals,we propose a new time-frequency combination test method based on the correction of the test parameters,as well as its correction method at different bandwidths.The test method is applied in a quick test of a high-power pulsed radar signal,and the corrected results have error less than 1 dB in both the time domain and the frequency domain,which indicates that the proposed time-frequency combined method is effective in testing strong and pulsed electromagnetic fields.
基金supported by a grant of the Korea Health Technology R & D Project through the Korea Health Industry Development Institute(KHIDI)funded by the Ministry of Health&Welfare,Republic of Korea(grant number:HI15C1535)
文摘Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal differentiation of BMSCs. Low-frequency PEMF can induce the neuronal differentiation of BMSCs in the absence of nerve growth factors. This study was designed to investigate the effects of low-frequency PEMF pretreatment on the proliferation and function of BMSCs and the effects of low-frequency PEMF pre-treated BMSCs on the regeneration of injured peripheral nerve using in vitro and in vivo experiments.In in vitro experiments, quantitative DNA analysis was performed to determine the proliferation of BMSCs, and reverse transcription-polymerase chain reaction was performed to detect S100 (Schwann cell marker), glial fibrillary acidic protein (astrocyte marker), and brain-derived neurotrophic factor and nerve growth factor (neurotrophic factors) mRNA expression. In the in vivo experiments, rat models of crush-injured mental nerve established using clamp method were randomly injected with low-frequency PEMF pretreated BMSCs, unpretreated BMSCs or PBS at the injury site (1 × 106 cells). DiI-labeled BMSCs injected at the injury site were counted under the fluorescence microscope to determine cell survival. One or two weeks after cell injection, functional recovery of the injured nerve was assessed using the sensory test with von Frey filaments. Two weeks after cell injection, axonal regeneration was evaluated using histomorphometric analysis and retrograde labeling of trigeminal ganglion neurons. In vitro experiment results revealed that low-frequency PEMF pretreated BMSCs proliferated faster and had greater mRNA expression of growth factors than unpretreated BMSCs. In vivo experiment results revealed that compared with injection of unpretreated BMSCs, injection of low-frequency PEMF pretreated BMSCs led to higher myelinated axon count and axon density and more DiI-labeled neurons in the trigeminal ganglia, contributing to rapider functional recovery of injured mental nerve. These findings suggest that low-frequency PEMF pretreatment is a promising approach to enhance the efficacy of cell therapy for peripheral nerve injury repair.
基金the National Natural Science Foundation of China for financially supporting this research through project No.51005027
文摘An electromagnetic coupling mathematical model is established by finite element method and is verified by the contrastive experiments of copper matrix Ni-TiN cylindrical coating electrode,copper electrode and Cu50 W electrode.The wear mechanism of Ni-TiN/Cu composite electrode in the case of high-frequency pulse current is studied,and the influence of the fluctuation frequency of discharge current on electrode wear in micro-EDM is found out.Compared with the electrode made from homogeneous material,the high frequency electromagnetic properties of Ni-TiN composite layer can be used effectively to inhibit the effect of high frequency pulse on the electrode and improve the distribution trend of current density.