期刊文献+
共找到941篇文章
< 1 2 48 >
每页显示 20 50 100
Adaptive target and jamming recognition for the pulse doppler radar fuze based on a time-frequency joint feature and an online-updated naive bayesian classifier with minimal risk 被引量:6
1
作者 Jian Dai Xin-hong Hao +2 位作者 Ze Li Ping Li Xiao-peng Yan 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第3期457-466,共10页
This paper considers the problem of target and jamming recognition for the pulse Doppler radar fuze(PDRF).To solve the problem,the matched filter outputs of the PDRF under the action of target and jamming are analyzed... This paper considers the problem of target and jamming recognition for the pulse Doppler radar fuze(PDRF).To solve the problem,the matched filter outputs of the PDRF under the action of target and jamming are analyzed.Then,the frequency entropy and peak-to-peak ratio are extracted from the matched filter output of the PDRF,and the time-frequency joint feature is constructed.Based on the time-frequency joint feature,the naive Bayesian classifier(NBC)with minimal risk is established for target and jamming recognition.To improve the adaptability of the proposed method in complex environments,an online update process that adaptively modifies the classifier in the duration of the work of the PDRF is proposed.The experiments show that the PDRF can maintain high recognition accuracy when the signal-to-noise ratio(SNR)decreases and the jamming-to-signal ratio(JSR)increases.Moreover,the applicable analysis shows that he ONBCMR method has low computational complexity and can fully meet the real-time requirements of PDRF. 展开更多
关键词 pulse doppler radar fuze(pdRF) Target and jamming recognition Time-frequency joint feature Online-update naive Bayesian classifier minimal risk(ONBCMR)
下载PDF
Study on the method of polarization suppression of cheating jamming in pulse Doppler radar 被引量:5
2
作者 SongLizhong QiaoXiaolin MengXiande JinMing 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2005年第2期310-315,共6页
A jamming suppression method based on polarization signal detection is proposed under common range and velocity cheating jammingfor pulse Doppler radar. On the basis of the separation of the target and the jamming, th... A jamming suppression method based on polarization signal detection is proposed under common range and velocity cheating jammingfor pulse Doppler radar. On the basis of the separation of the target and the jamming, the range and velocity track on the true target are realized. Firstly the signal processing model of the full polarization pulse Doppler radar is introduced. Secondly the method of correct target separation is discussed, which is the twice detections of energy and polarization state on the two dimension resolution cells of range and velocity of the radar echo. Finally the simulations are performed and the results prove the validity. What's more, multiple range and velocity cheating jamming can be suppressed at the same time if the target and the jamming are different in the polarization domain. 展开更多
关键词 pulse doppler radar POLARIZATION signal detection.
下载PDF
Repeater jamming suppression method for pulse Doppler fuze based on identity recognition and chaotic encryption 被引量:6
3
作者 Jian Dai Xin-hong Hao +2 位作者 Qiang Liu Xiao-peng Yan Ping Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第3期1002-1012,共11页
Pulse Doppler(PD) fuze is widely used in current battlefield. However, with the threat of repeater jamming, especially digital radio frequency memory technology, the deficiency in the anti-repeater jamming of a tradit... Pulse Doppler(PD) fuze is widely used in current battlefield. However, with the threat of repeater jamming, especially digital radio frequency memory technology, the deficiency in the anti-repeater jamming of a traditional PD fuze increasingly emerges. Therefore, a repeater jamming suppression method for a PD fuze based on identity(ID) recognition and chaotic encryption is proposed. Every fuze has its own ID which is encrypted with different chaotic binary sequences in every pulse period of the transmitted signal. The thumbtack-shaped ambiguity function shows a good resolution and distance cutoff characteristic. The ability of anti-repeater jamming is emphatically analyzed, and the results at different signal-to-noise ratio(SNR) show a strong anti-repeater jamming ability and range resolution that the proposed method possesses. Furthermore, the anti-repeater jamming ability is influenced by processing gain, bit error rate(BER) and correlation function. The simulation result validates the theoretical analysis, it shows the proposed method can significantly improve the anti-repeater jamming ability of a PD fuze. 展开更多
关键词 pulse doppler fuze ID Chaotic binary code ENCRYPTION Repeater jamming
下载PDF
Pulse wave Doppler ultrasound of testicular arteries and their relationship with semen characteristics in healthy bulls 被引量:1
4
作者 Alessia Gloria Augusto Carluccio +3 位作者 Laura Wegher Domenico Robbe Claudio Valorz Alberto Contri 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2018年第2期319-325,共7页
Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depicti... Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depiction of the actual function of the testis. Since testis vascularization might be critical for the gonad function, selected pulse wave Doppler ultrasound parameters were assessed in this study, for instance the peak systolic velocity, the end diastolic velocity and the resistive index of the testicular artery along the spermatic cord, the marginal portion of the testicular artery and the intratesticular branches of the testicular artery both in healthy adult and young bulls.Correlations between these parameters and characteristics of semen that was collected numerous times, before and after the Doppler ultrasound examination.Results: The peak systolic velocity and the end diastolic velocity measured in the testicular artery along the spermatic cord(supratesticular artery – SA) were variable among the bulls and within individual bulls, likely due to the convoluted course of the vessel. The resistive index was found highly repeatable in the same bull. A reduction in the resistive index was found between the supratesticular artery and the marginal portion of the testicular artery(P < 0.01), and between the marginal portion of the testicular artery and the intratesticular branches of the testicular artery(P < 0.05). No differences were recorded for the pulse wave Doppler ultrasound parameters in young bulls compared with adults. A significant correlation was found between the resistive index of the marginal portion of the testicular artery and total sperm in the ejaculate(r = 0.516, P < 0.05), the immature sperm(r = 0.462, P < 0.05), the teratoid sperm(r = 0.375, P < 0.05), and the "Dag defect" sperm(r = 0.389, P < 0.05). Similarly, the resistive index of the intratesticular branches of the testicular artery were found correlated with the total sperm number in the ejaculate(r = 0.568, P < 0.05), the immature sperm(r = 0.523, P < 0.05), the teratoid sperm(r = 0.418, P < 0.05), and the "Dag defect" sperm(r = 0.341, P < 0.05).Conclusions: The data presented in this study suggest that the resistive index, measured at the marginal portion of the testicular artery, could be an easy-to-perform parameter to evaluate the spermatogenesis quality in young bulls and normal adults. 展开更多
关键词 BULL pulse wave doppler SPERM morphology TESTIS Ultrasound
下载PDF
Hemodynamics in the portal vein evaluated by pulse wave Doppler ultrasonography in patients with chronic hepatitis C treated with interferon 被引量:1
5
作者 Shigeo Nakanishi Katsuya Shiraki +3 位作者 Kouji Yamamoto Mutsumi Koyama Noboru Kimura Takeshi Nakano 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第3期396-399,共4页
AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN)treatment.METHODS: The subjects in this stud... AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN)treatment.METHODS: The subjects in this study were 14 patients (13 men and 1 woman) with CHC who received IFN treatment. Portal blood flow velocity was measured in the vessels at the porta hepatis at four time points: before IFN administration (pre-IFN), 2 wk after the start of administration (wk 2), 24 wk after the start of administration (wk 24, i.e.,the end of IFN administration), and 24 wk after the end of administration (wk 48).RESULTS: The patients with CHC in whom IFN treatment resulted in complete elimination or effective elimination of viruses showed a significant increase in portal blood flow velocity at the end of IFN treatment compared with that before IFN treatment. In contrast, when IFN was ineffective, no significant increase in portal bloocl flow velocity was observed at wk 24 or 48 compared with the pre-IFN value. In addition,the patients with CHC in whom IFN was ineffective showed significantly lower portal blood flow velocity values than control subjects at all measurement time points.CONCLUSION: Pulse wave Doppler ultrasonography is a noninvasive and easily performed method for evaluating the effects of IFN treatment in patients with CHC. This technique is useful for measuring portal blood flow velocity before and 24 wk after IFN administration in order to evaluate the changes over time, thus assessing the effectiveness of IFN treatment. 展开更多
关键词 血流动力学 血管入口 脉搏 多普勒超生诊断法 慢性丙型肝炎 干扰素 CHC
下载PDF
QUANTITATIVE ANALYSIS ON CHANGES OF HEPATIC HEMODYNAMICS AFTER TRANSCUTANEOUS ELECTRIC PULSE STIMULATION OF LOCAL POINTS BY USING COLOR DOPPLER ULTRASOUND DIAGNOSTIC APPARATUS
6
作者 张均倡 王岭 +2 位作者 李红 李峻 张云 《World Journal of Acupuncture-Moxibustion》 2006年第3期3-7,共5页
Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer p... Objective: To evaluate the effect of transcutaneous electric pulse stimulation (TEPS) on hepatic blood flow and parenchymal microcirculation in patients with fatty liver. Methods: A total of 31 fatty liver volunteer patients were observed in this study. Changes of color Doppler energy (CDE) images before and after TEPS of local points nearby the liver were recorded by using color Doppler ultrasound diagnostic apparatus (ACUSON 128XP/10C). Sum of color pixel area (SCPA), average of color value (ACV) and SCPA×ACV (integral) of the hepatic flow images were analyzed by an image processing system, single blind method and paired t-test. Programmed TEPS (0.5- 150 Hz / 2 000 Hz , 10- 25 V ) was applied to the right Qimen (期门 LR 14)-Jingmen (京门 GB 25), Fuai (腹哀 SP 16)-Ganshu (肝俞 BL 18) respectively for 15 min. Results: Compared with basic values of pretreatment, SCPA, ACV and SCPA×ACV increased significantly (t=2.71, P<0.02; t=3.42, P<0.01; and t=8.15, P<0.001) after TEPS, meaning improvement of hepatic blood flow supply. Conclusion: TEPS of acupoints near the liver can improve hepatic blood flow and hepatic parenchymal microcirculation in patients with fatty liver. 展开更多
关键词 FATTY liver TRANSCUTANEOUS electric pulse STIMULATION Color doppler energy HEPATIC
下载PDF
SEVERAL PROBLEMS IN DESIGNING DBS SYSTEMS FOR AIRBORNE PULSE DOPPLER RADAR
7
作者 杨建航 《Chinese Journal of Aeronautics》 SCIE EI CSCD 1998年第2期20-28,共9页
SEVERALPROBLEMSINDESIGNINGDBSSYSTEMSFORAIRBORNEPULSEDOPPLERRADARYANGJianhang(杨建航)(DepartmentofAero-Electroni... SEVERALPROBLEMSINDESIGNINGDBSSYSTEMSFORAIRBORNEPULSEDOPPLERRADARYANGJianhang(杨建航)(DepartmentofAero-ElectronicEnginering,AirFo... 展开更多
关键词 pulse doppler radar doppler beam sharpening (DBS) batch processing period frame scan time
下载PDF
Doppler shift of a laser pulse beam scattered by a rotating cone and cylinder
8
作者 王保平 王明军 +2 位作者 吴振森 李应乐 向宁静 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第5期60-65,共6页
Based on laser radar equations, a Doppler shift model of a laser pulse beam scattered by a rotating arbitrary convex target is reported in this paper. The boundary relations between an incident pulse beam and the dete... Based on laser radar equations, a Doppler shift model of a laser pulse beam scattered by a rotating arbitrary convex target is reported in this paper. The boundary relations between an incident pulse beam and the detected area elements are analyzed by geometric methods. The Doppler shift characteristics of the rotating cone and cylinder are discussed and the difference between the laser pulse beam and the plane wave scattered from the same rotating target is compared accordingly. Numerical simulations show that the Doppler shift is tightly relevant to their dimensions, speeds, and so on. In the same incidence conditions, the pulse beam and plane wave have difference peak values and the same Doppler shift bandwidth. If the waist radius of the pulse beam is larger, the peak value is higher, and the Doppler shifts are proportional to the speed of the rotating target. By virtue of our theoretical model, we probe into the scattered characteristics of the Doppler shifts of a laser pulse beam, which would benefit target identification in national defense. 展开更多
关键词 scattered characteristics of laser pulse beams doppler shift laser radar target identification
下载PDF
STUDY OF PULSED DOPPLER SIGNAL PROCESSING AND VELOCITY TRACKING TECHNIQUE
9
作者 Fan Laiyao Ji Hongbing (School of Electronic Engineering, Xi’dian University, Xi’an 710071) 《Journal of Electronics(China)》 1996年第2期122-128,共7页
This paper describes a signal processing system in a Pulsed Doppler (PD) radar. It mainly consists of a velocity tracking loop and a digital signal processing auxiliary channel. With many signal processing techniques,... This paper describes a signal processing system in a Pulsed Doppler (PD) radar. It mainly consists of a velocity tracking loop and a digital signal processing auxiliary channel. With many signal processing techniques, the system successfully solves the signal detection and tracking at low SNR and the interference identification and rejection. The idea of system design is introduced in detail. Finally, some simulation and experimental results are presented. 展开更多
关键词 pulseD doppler radar SEQUENTIAL detection α-β filter VELOCITY tracking LOOP ACCELERATION compensation integration
下载PDF
Prevalence of Atrial Fibrillation in Systolic Heart Failure, Pulsed and Tissue Doppler Echocardiographic Abnormalities
10
作者 Salih H. Gabani Taysir S. Garadah +3 位作者 Adela B. Hassan Ahmed A. Jaradat Mohamed E. Al Alawi Zuheir A. Hasan 《International Journal of Clinical Medicine》 2013年第11期504-509,共6页
Background: Heart failure (HF) is a common clinical syndrome mostly due to the impaired ability of the Left Ventricle (LV) to eject blood with reduced cardiac output. Heart failure is called systolic (SHF) if left ven... Background: Heart failure (HF) is a common clinical syndrome mostly due to the impaired ability of the Left Ventricle (LV) to eject blood with reduced cardiac output. Heart failure is called systolic (SHF) if left ventricle ejection fraction on echo-cardiogram is low (LVEF of ≤50%). Aim: To assess the echocardiographic characteristics of patients with SHF with Atrial Fibrillation (AF) and compare with those with Sinus Rhythm (SR) on 12 leads ECG. Furthermore, to evaluate the clinical and biochemical markers for the prediction of AF in SHF. Method: Over two years duration, each patient diagnosed with SHF was enrolled in the study (n = 354) based on admission code. AF or sinus rhythm on 12 leads ECG was documented on each patient. Multiple logistic regression analysis was applied to assess the risk ratio of different clinical and Doppler derived variables for the development of AF in SHF. Results: Out of the total hospital medical admissions of 14,674 patients, there were 354 patients with diagnosis of SHF, a prevalence of 2.4%. The incidence of AF on ECG was 109 (31%) patients in the whole study population and 245 (69%) in SR. M Mode echocardiogram in patients with SHF and AF compared with those in SR showed significant dilation of LV cavity in systole with LVESD of 5.72 ± 0.63 vs. 5.23 ± 0.76 cm, P < 0.001 and in Diastole LVEDD of 6.83 ± 0.51 vs. 6.58 ± 0.63 cm, P < 0.001. Pulsed Doppler echocardiogram showed a severe restrictive-pattern with shorter Decellration Time (DT) of 163.73 ± 7.42 vs. 214.9 ± 31.81msec, P < 0.001 and higher Pulse to Tissue Doppler ratio of E/Em of 14.26 ± 1.34 vs. 9.99 ± 1.27, P , and the serum level of Brain Natriuretic Peptide (BNP) hormone of 723.72 ± 13.45 vs. 686.98 ± 72.57 pg/ml, P < 0.001. The predictive risks (odd ratio) of different clinical variables for the development of AF in SHF were positive for high BNP > 500 pg/ml of 2.8, history of hypertension of 1.8, history of DM of 1.7, BMI > 28 of 1.4, LV hypertrophy on ECG of 1.3. Conclusions: The prevalence of Systolic Heart Failure in the study population was 2.4%. The prevalence of AF in the study population was 31%. The best predictors of AF in SHF were high BNP > 500 pg/ml, history of hypertension, Diabete Mellitus and LV Hypertrophy on ECG. 展开更多
关键词 SYSTOLIC HEART Failure pulse doppler Tissue doppler PREVALENCE
下载PDF
加速器生产^(103)Pd的厚铑靶制备工艺研究
11
作者 马承伟 段菲 +6 位作者 褚浩淼 李光 王晓明 赵紫宇 李超 王成志 温凯 《同位素》 CAS 2024年第1期55-63,共9页
铑靶的制备是加速器生产核素^(103)Pd的关键技术。为制得致密、稳定、厚度高的铑靶,采用改性工艺对硫酸铑溶液进行预处理,并加入一定量电镀添加剂A,得到低应力镀铑液。实验靶片选择金属铜材质,靶片面积约100 mm×10 mm。分别针对电... 铑靶的制备是加速器生产核素^(103)Pd的关键技术。为制得致密、稳定、厚度高的铑靶,采用改性工艺对硫酸铑溶液进行预处理,并加入一定量电镀添加剂A,得到低应力镀铑液。实验靶片选择金属铜材质,靶片面积约100 mm×10 mm。分别针对电镀过程中的电源电流密度、电镀温度、H_(2)SO_(4)浓度、电镀添加剂A浓度等进行条件实验,获得最佳电镀条件。结果表明,选用最佳电镀条件下,连续四个批次制备的铑镀层质量厚度均大于150 mg/cm^(2),在热冲击实验和坠落实验中,镀层未出现起皮、脱落等问题,镀层致密、平整、与基底结合牢固。在C30回旋加速器内辐照5~51.5 h,可以获得产额5.18~6.04 MBq/(μA·h)、核纯度大于99.9%的^(103)Pd核素。本研究解决了脉冲电镀法制备铑靶工艺稳定性差的问题,制备的厚铑靶可满足^(103)Pd批量化生产要求。 展开更多
关键词 ^(103)pd 核素制备 回旋加速器 脉冲电镀 近距离治疗
下载PDF
Ankle-brachial index and brachial-ankle pulse wave velocity are risk factors for ischemic stroke in patients with type 2 diabetes 被引量:5
12
作者 Ting Li Xiu-juan Wu +3 位作者 Xiao-min Chen Si-bo Wang Kang-ding Liu Ying-qi Xing 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第11期1853-1859,共7页
The incidence of ischemic stroke in patients with diabetes is increasing. While brachial-ankle pulse wave velocity (BaPWV) and ankle-bra- chial index (ABI) are known to be associated with ischemic cardiovascular a... The incidence of ischemic stroke in patients with diabetes is increasing. While brachial-ankle pulse wave velocity (BaPWV) and ankle-bra- chial index (ABI) are known to be associated with ischemic cardiovascular and cerebrovascular diseases, whether these measures predict the risk of ischemic cerebrovascular disease in diabetic patients remains unclear. 117 patients with type 2 diabetes were enrolled in this study. According to the results of head magnetic resonance imaging, the patients were divided into a diabetes-only group (n = 55) and a diabetes and ischemic stroke group (n = 62). We then performed ABI and BaPWV examinations for all patients. Compared with the diabe- tes-only group, we found decreased ABI and increased BaPWV in the diabetes and ischemic stroke group. Multivariate logistic regression analyses revealed that BaPWV and ABI were risk factors for ischemic stroke in patients with type 2 diabetes. Our findings indicate that decreased ABI and increased BaPWV are objective indicators of increased risk of ischemic stroke in patients with type 2 diabetes. 展开更多
关键词 nerve regeneration brain injury ischemic stroke type 2 diabetes ankle-brachial index brachial-ankle pulse wave velocity magnetic resonance imaging low-density lipoprotein high-density lipoprotein transcranial doppler ultrasonography carotid ultrasound scans neural regeneration
下载PDF
Use of pocket pulse oximeters for detecting peripheral arterial disease in patients with diabetes mellitus 被引量:1
13
作者 Javier Ena Carlos R. Argente +3 位作者 Víctor González-Sánchez Natividad Algado Gema Verdú Teresa Lozano 《Journal of Diabetes Mellitus》 2013年第2期79-85,共7页
Recent Aims: New diagnostic methods are needed to detect peripheral arterial disease easier than using the ankle-brachial index measured by Doppler devices. We investigated whether the use of pocket pulse oximeters co... Recent Aims: New diagnostic methods are needed to detect peripheral arterial disease easier than using the ankle-brachial index measured by Doppler devices. We investigated whether the use of pocket pulse oximeters could meet sensitivity and specificity criteria as screening method to detect significant peripheral arterial perfusion deficits. Methods: We measured oxygen saturation (SaO2) at index fingers and great toes (on horizontal and elevated 30°) by a pocket pulse oximeter in 250 subjects with diabetes mellitus attending the outpatient clinic. A finger-to-toe SaO2 gradient greater than 2% was considered abnormal. Ankle-brachial index was measured by a hand held Doppler device. Peripheral arterial disease was defined as an ankle-brachial index less than 0.9. Results: A total of 1392 (93%) valid SaO2 readings were obtained. Twenty-seven (11%) patients were excluded due to not having measurable SaO2 finger-to-toe gradients. A total of 223 patients were analyzed. Peripheral arterial disease was detected in 47 (21%) patients. A finger-to-toe SaO2 gradient greater than 2% had sensitivity 42.6% (95% CI 30.0% - 55.3%), specificity 79.1% (95% CI 75.7% - 82.6%), positive predictive value 35.7% (95% CI 25.2% - 46.4%), negative predictive value 83.4% (95% CI 79.8 - 87.1), positive likelihood ratio 2.03 (95% CI 1.23 - 3.17) and negative likelihood ratio 0.73 (95% CI 0.54 - 0.93) to detect peripheral arterial disease. The area under the receiving operating characteristic curve was 0.69 (95% CI 0.62 - 0.77). Conclusion: Pocket pulse oximeters showed insufficient sensitivity as screening method for detecting peripheral arterial disease in patients with diabetes mellitus. 展开更多
关键词 Ankle-Brachial Pressure Index doppler Ultrasound pulse OXIMETRY Comparative Study Sensitivity SPECIFICITY LIKELIHOOD Ratio
下载PDF
Simultaneous range and radial velocity estimation with a single narrowband LFM pulse 被引量:6
14
作者 Chunmao Yeh Jian Yang +1 位作者 Xiuming Shan Yingning Peng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2012年第3期372-377,共6页
The mismatch effect induced by the radial motion of a target is analyzed for linear frequency modulated (LFM) signals. Then, a novel integrated processing scheme is proposed to re- solve the delay-Doppler coupling e... The mismatch effect induced by the radial motion of a target is analyzed for linear frequency modulated (LFM) signals. Then, a novel integrated processing scheme is proposed to re- solve the delay-Doppler coupling effect in LFM pulse compression. Therefore the range and radial velocity of the target can be si- multaneously estimated with a narrowband LFM pulse. Finally, numerical simulation results demonstrate the effectiveness and good performance of the proposed method. 展开更多
关键词 delay-doppler coupling motion estimation linear fre- quency modulated (LFM) pulse extended filtering.
下载PDF
Simulation and experiment of the cooling effect of trapped ion by pulsed laser
15
作者 方长达人 黄垚 +2 位作者 管桦 钱源 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第7期226-233,共8页
We investigate the process of pulsed laser cooling using a self-constructed molecular dynamics simulation(MDSimulation)program.We simulate the Doppler cooling process and pulsed laser Doppler cooling process of a sing... We investigate the process of pulsed laser cooling using a self-constructed molecular dynamics simulation(MDSimulation)program.We simulate the Doppler cooling process and pulsed laser Doppler cooling process of a single^(40)Ca^(+)ion,and the comparison with the experimental results shows that this self-constructed MD-Simulation program works well in the weak laser intensity situation.Furthermore,we analyze the pulsed laser Doppler cooling process of a single^(27)Al^(+)ion.This program can be used to analyze the molecular dynamic process of various situations of Doppler cooling in an ion trap,which could give predictions and experimental guidance. 展开更多
关键词 doppler cooling pulsed laser cooling molecular dynamics simulation
下载PDF
PULSE CUMULATING METHOD FOR MULTI-TARGETS' JOINT AZIMUTH-ELEVATION FREQUENCY-DELAY ESTIMATION
16
作者 Wu Xianglin Yu Bianzhang +1 位作者 Xie Hongmei Song Zuxun 《Journal of Electronics(China)》 2006年第3期370-373,共4页
The Directions of Arrivals (DOAs), speeds and distances of targets are all required for array signal processing. Based on the periodic phase shift of coherent pulse sequence waveform, a new estimation of multi-targets... The Directions of Arrivals (DOAs), speeds and distances of targets are all required for array signal processing. Based on the periodic phase shift of coherent pulse sequence waveform, a new estimation of multi-targets' 2-Dimentional (2-D) DOA angle, Doppler frequency shift and relative time-delay is proposed. Based on a virtual sensor array constructed by pulse cumulating, the estimations of azimuth, elevation, Doppier frequency shift and time-delay can be obtained simultaneously, and the least number of pulses could be two. This method is computationally efficient even in heavier noised environment, and all estimations are automatically paired in calculation process with no spectrum searching. Further more, this algorithm can be used to any plane sensor array and deal with many targets at the same time only by few sensors. The targets number that can deal with simultaneously is several times to the sensor number, which is the upper limit for normal algorithms such as ESPRIT and MUSIC. These characteristics would be very useful, especially, for aerial systems. Simulations demonstrate the capabilities of this method efficiently. 展开更多
关键词 脉冲累积 虚拟传感器 DOA 多普勒频率
下载PDF
基于二相码的PD雷达解模糊及遮挡方法
17
作者 严济鸿 张欢 +2 位作者 倪伟涵 杨礼 何子述 《系统工程与电子技术》 EI CSCD 北大核心 2023年第6期1667-1674,共8页
为避免二相编码脉冲多普勒(pulse Doppler,PD)雷达的速度以及距离模糊,采用高脉冲重复频率工作(high pulse repetition frequency,HPRF)模式,并在多个脉冲间采用互相关峰值较低的二相编码信号,在接收端对多个发射脉冲间的回波信号进行... 为避免二相编码脉冲多普勒(pulse Doppler,PD)雷达的速度以及距离模糊,采用高脉冲重复频率工作(high pulse repetition frequency,HPRF)模式,并在多个脉冲间采用互相关峰值较低的二相编码信号,在接收端对多个发射脉冲间的回波信号进行数据重排,然后进行脉冲压缩、动目标检测,最终得到的峰值可无模糊体现目标的速度和距离。为减小PD雷达的工作盲区,采用了小的发射脉冲时间宽度,即二相编码信号的码片长度;为避免PD雷达的发射脉冲遮挡,采用两种HPRF发射正交二相编码脉冲信号。仿真结果验证了所提方法的有效性和可行性。 展开更多
关键词 脉冲多普勒雷达 二相编码信号 距离速度模糊 遮挡
下载PDF
方位向调制干扰对高分宽幅多通道SAR的影响
18
作者 邢世其 纪朋徽 +1 位作者 代大海 冯德军 《系统工程与电子技术》 EI CSCD 北大核心 2024年第6期1946-1956,共11页
多通道合成孔径雷达(synthetic aperture radar,SAR)能够利用方位向多通道重构处理去除多普勒模糊,获得高分宽幅SAR图像。针对此特殊的多通道重构处理方式,研究了传统SAR方位向调制干扰对高分宽幅多通道SAR的影响,包括多普勒调制干扰和... 多通道合成孔径雷达(synthetic aperture radar,SAR)能够利用方位向多通道重构处理去除多普勒模糊,获得高分宽幅SAR图像。针对此特殊的多通道重构处理方式,研究了传统SAR方位向调制干扰对高分宽幅多通道SAR的影响,包括多普勒调制干扰和脉冲延迟转发干扰两种类型的方位向调制干扰方式,为高分宽幅多通道SAR干扰决策提供理论基础。理论分析指出,多普勒调制干扰信号经成像处理后将在方位向生成等间隔分布的虚假目标,并且幅度受与多普勒调制频率相关的正弦函数和匹配滤波损失联合调制;而脉冲延迟转发干扰信号在成像后将只有单个干扰目标出现,且目标的方位位置仅与延迟的脉冲数有关。仿真实验验证了理论分析的正确性。 展开更多
关键词 合成孔径雷达 高分宽幅 多普勒调制干扰 脉冲延迟调制干扰
下载PDF
基于时域编码超表面脉内-脉间编码优化的雷达干扰方法 被引量:1
19
作者 许恒 许红 +5 位作者 全英汇 潘秦 沙明辉 陈珲 程强 周小阳 《雷达学报(中英文)》 EI CSCD 北大核心 2024年第1期215-226,共12页
时域编码超表面是一项可以对电磁波进行时变调制的新技术,针对该技术的调控特性,该文提出了一种基于时域编码超表面脉内-脉间编码优化的雷达干扰方法。首先分别在快时间域和慢时间域建立优化模型,通过优化脉内-脉间相位编码,实现目标能... 时域编码超表面是一项可以对电磁波进行时变调制的新技术,针对该技术的调控特性,该文提出了一种基于时域编码超表面脉内-脉间编码优化的雷达干扰方法。首先分别在快时间域和慢时间域建立优化模型,通过优化脉内-脉间相位编码,实现目标能量的搬移,形成距离-多普勒二维图上的欺骗干扰。然后通过遗传算法对该离散优化模型进行求解。另外,该文从超表面编码策略的角度分析了多种调控因素对干扰效果的影响,为实现欺骗干扰的最佳策略提供指导。 展开更多
关键词 电子对抗 雷达欺骗干扰 时域编码超表面 相位编码优化 脉冲多普勒雷达
下载PDF
一种PD雷达半实物仿真系统的研究 被引量:3
20
作者 刘 烽 初昀辉 +1 位作者 许家栋 郭陈江 《西北工业大学学报》 EI CAS CSCD 北大核心 2002年第1期58-61,共4页
针对脉冲多普勒雷达在航空火控系统中的广泛应用,提出了一套对脉冲多普勒雷达系统进行半实物仿真的设计方案。以目标回波特性的研究为基础,对目标回波的各种特性进行了模拟。在对目标航迹的模拟中,设计了一种新颖、简单的控制机构。... 针对脉冲多普勒雷达在航空火控系统中的广泛应用,提出了一套对脉冲多普勒雷达系统进行半实物仿真的设计方案。以目标回波特性的研究为基础,对目标回波的各种特性进行了模拟。在对目标航迹的模拟中,设计了一种新颖、简单的控制机构。利用频谱搬移解决了多普勒频移难以混频的问题。理论和实验的结果表明,该系统能有效模拟脉冲多普勒雷达的目标回波,具有重要的实际应用价值。 展开更多
关键词 脉冲多普勒雷达 半实物仿真 目标回波 pd雷达 目标航迹 航空失控系统
下载PDF
上一页 1 2 48 下一页 到第
使用帮助 返回顶部