期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Q-Switching Pulse Operation in 1.5-μm Region Using Copper Nanoparticles as Saturable Absorber 被引量:1
1
作者 A.R.Muhammad M.T.Ahmad +6 位作者 R.Zakaria H.R.A.Rahim S.F.A.Z.Yusoff K.S.Hamdan H.H.M.Yusof H.Arof S.W.Harun 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期41-44,共4页
We demonstrate a passively Q-switched erbium-doped fiber laser (EDFL) using a copper nanoparticle (CuNP) thin film as the saturable absorber in a ring cavity. A stable Q-switched pulse operation is observed as the... We demonstrate a passively Q-switched erbium-doped fiber laser (EDFL) using a copper nanoparticle (CuNP) thin film as the saturable absorber in a ring cavity. A stable Q-switched pulse operation is observed as the CuNP saturable absorber (SA) is introduced in the cavity. The pulse repetition rate of the EDFL is observed to be proportional to the pump power, and is limited to 101.2kHz by the maximum pump power of 113.7mW. On the other hand, the pulse width reduces from 10.19μs to 4.28μs as the pump power is varied from 26.1 mW to 113.7mW. The findings suggest that CuNP SA could be useful as a potential saturable absorber for the development of the robust, compact, efficient and low cost Q-switched fiber laser operating at 1.5-μm region. 展开更多
关键词 Cu m Region Using Copper Nanoparticles as Saturable Absorber Q-Switching pulse operation in 1.5 SA kHz EDF
下载PDF
A Broadband Pulsed External-Cavity Quantum Cascade Laser Operating near 6.9μm
2
作者 罗威 段传喜 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第2期55-57,共3页
We report an external cavity quantum cascade laser (EC-QCL) operating near 6.9μm using the Littman Metcalf configuration. The EC-QCL works in a pulsed mode and can be tuned continuously from 1340 to 1640cm^-1 by on... We report an external cavity quantum cascade laser (EC-QCL) operating near 6.9μm using the Littman Metcalf configuration. The EC-QCL works in a pulsed mode and can be tuned continuously from 1340 to 1640cm^-1 by only tilting the tuning mirror. The fine tuning ability of the EC-QCL is demonstrated by measuring the absorption spectrum of water in the ambient air with a lock-in amplifier. 展开更多
关键词 QCL EC in A Broadband pulsed External-Cavity Quantum Cascade Laser Operating near 6.9 of MODE
下载PDF
Investigation on discharge characteristics of a coaxial dielectric barrier discharge reactor driven by AC and ns power sources 被引量:6
3
作者 王乾 刘峰 +2 位作者 苗传润 严冰 方志 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第3期78-86,共9页
A coaxial dielectric barrier discharge(DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond(ns)pulse to generate atmospheric ... A coaxial dielectric barrier discharge(DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond(ns)pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 ℃ and 64.3 ℃ after 900 s operation, respectively.The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs,reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications. 展开更多
关键词 coaxial dielectric barrier discharge discharge characteristics nanosecond pulse operation temperature
下载PDF
A Ka-band Solid-state Transmitter Cloud Radar and Data Merging Algorithm for Its Measurements 被引量:7
4
作者 Liping LIU Jiafeng ZHENG Jingya WU 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2017年第4期545-558,共14页
This study concerns a Ka-band solid-state transmitter cloud radar, made in China, which can operate in three different work modes, with different pulse widths, and coherent and incoherent integration numbers, to meet ... This study concerns a Ka-band solid-state transmitter cloud radar, made in China, which can operate in three different work modes, with different pulse widths, and coherent and incoherent integration numbers, to meet the requirements for cloud remote sensing over the Tibetan Plateau. Specifically, the design of the three operational modes of the radar(i.e., boundary mode M1, cirrus mode M2, and precipitation mode M3) is introduced. Also, a cloud radar data merging algorithm for the three modes is proposed. Using one month's continuous measurements during summertime at Naqu on the Tibetan Plateau,we analyzed the consistency between the cloud radar measurements of the three modes. The number of occurrences of radar detections of hydrometeors and the percentage contributions of the different modes' data to the merged data were estimated.The performance of the merging algorithm was evaluated. The results indicated that the minimum detectable reflectivity for each mode was consistent with theoretical results. Merged data provided measurements with a minimum reflectivity of -35 dBZ at the height of 5 km, and obtained information above the height of 0.2 km. Measurements of radial velocity by the three operational modes agreed very well, and systematic errors in measurements of reflectivity were less than 2 dB. However,large discrepancies existed in the measurements of the linear depolarization ratio taken from the different operational modes.The percentage of radar detections of hydrometeors in mid- and high-level clouds increased by 60% through application of pulse compression techniques. In conclusion, the merged data are appropriate for cloud and precipitation studies over the Tibetan Plateau. 展开更多
关键词 data merging algorithm operational mode Ka-band radar cloud Tibetan Plateau pulse compression technique
下载PDF
Passively spatiotemporal gain-modulation-induced stable pulsing operation of a random fiber laser 被引量:4
5
作者 JIANGMING XU JUN YE +4 位作者 WEI LIU JIAN WU HANWEI ZHANG JINYONG LENG PU ZHOU 《Photonics Research》 SCIE EI 2017年第6期117-122,共6页
Unlike a traditional fiber laser with a defined resonant cavity, a random fiber laser(RFL), whose operation is based on distributed feedback and gain via Rayleigh scattering(RS) and stimulated Raman scattering in a lo... Unlike a traditional fiber laser with a defined resonant cavity, a random fiber laser(RFL), whose operation is based on distributed feedback and gain via Rayleigh scattering(RS) and stimulated Raman scattering in a long passive fiber, has fundamental scientific challenges in pulsing operation for its remarkable cavity-free feature. For the time being, stable pulsed RFL utilizing a passive method has not been reported. Here, we propose and experimentally realize the passive spatiotemporal gain-modulation-induced stable pulsing operation of counterpumped RFL. Thanks to the good temporal stability of an employed pumping amplified spontaneous emission source and the superiority of this pulse generation scheme, a stable and regular pulse train can be obtained.Furthermore, the pump hysteresis and bistability phenomena with the generation of high-order Stokes light is presented, and the dynamics of pulsing operation is discussed after the theoretical investigation of the counterpumped RFL. This work extends our comprehension of temporal property of RFL and paves an effective novel avenue for the exploration of pulsed RFL with structural simplicity, low cost, and stable output. 展开更多
关键词 RFL Passively spatiotemporal gain-modulation-induced stable pulsing operation of a random fiber laser
原文传递
Pulsed actuation avoids failure in dielectric elastomer artificial muscles
6
作者 Toma Kobayashi Stoyan K.Smoukov 《International Journal of Smart and Nano Materials》 SCIE EI 2014年第4期217-226,共10页
Dielectric elastomer actuators(DEAs)are a class of artificial muscles capable of large linear strains(well over 100%),and with high energy density,and low cost and weight.One of the most prominent failure modes of a D... Dielectric elastomer actuators(DEAs)are a class of artificial muscles capable of large linear strains(well over 100%),and with high energy density,and low cost and weight.One of the most prominent failure modes of a DEA is electrical breakdown,which can damage the device permanently,limiting its deformation capability.Breakdown is also common,since to maximize energy output,devices often operate near the breakdown limit.Elucidating breakdown mechanisms,as well as finding ways to prevent it,are of intense research interest.We show that by applying short electrical pulses,one could minimize the exposure of the DEAs to high leakage current,which is one of the main mechanisms for electrical breakdown.This allows one to operate at significantly higher potentials than the DC breakdown voltage.By applying pulses,we demonstrate up to 81.7%area strain repeatedly,at voltages more than twice the DC breakdown limit,without the risk of failure.The pulsed operation mode of DEAs accommodating higher voltages than possible with DC represents an opportunity for potential applications,safer and simpler device designs,and a technique for further study of DEA breakdown mechanisms. 展开更多
关键词 dielectric elastomer electrical breakdown pulsed operation leakage current high voltage design safety
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部