This paper analyses a key problem in the quantification of pulse diagnosis. Due to the subjectivity and fuzziness of pulse diagnosis,quantitative methods are needed. To extract the parameters of pulse signals,the prer...This paper analyses a key problem in the quantification of pulse diagnosis. Due to the subjectivity and fuzziness of pulse diagnosis,quantitative methods are needed. To extract the parameters of pulse signals,the prerequisite is to detect the corners of pulse signals correctly. Up to now,the pulse parameters are mostly acquired by marking the pulse corners manually,which is an obstacle to modernize pulse diagnosis. Therefore,a new automatic parameters extraction approach for pulse signals using wavelet transform is presented. The results testified that the method we proposed is feasible and effective and can detect corners of pulse signals accurately,which can be expected to facilitate the modernization of pulse diagnosis.展开更多
In the design of filter shaping circuits for nuclear pulse signals,inverting filter shaping circuits perform better than non-inverting filter shaping circuits.Because these circuits facilitate changing the phase of a ...In the design of filter shaping circuits for nuclear pulse signals,inverting filter shaping circuits perform better than non-inverting filter shaping circuits.Because these circuits facilitate changing the phase of a pulse signal,they are widely used in processing nuclear pulse signals.In this study,the transfer functions of four types of inverting filter shaping circuits,namely the common inverting filter shaping,improved inverting filter shaping,multiple feedback low-pass filter shaping,and third-order multiple feedback low-pass filter shaping,in the Laplacian domain,are derived.We establish the numerical recursive function models and digitalize the four circuits,obtain the transfer functions in the Z domain,and analyze the filter performance and amplitude-frequency response characteristics in the frequency domain.Based on the actual nuclear pulse signal of the Si-PIN detector,we realize four types of inverting digital shaping.The results show that under the same shaping parameters,the common inverting digital shaping has better amplitude extraction characteristics,the third-order multiple feedback low-pass digital shaping has better noise suppression performance,and the multiple feedback digital shaping takes into account both pulse amplitude extraction and noise suppression performance.展开更多
In this letter, with the synthesis of usual cross-correlation detecting method andchaotic detecting method, a new detecting system for the weak periodic pulse signal is constituted,in which the two methods can play re...In this letter, with the synthesis of usual cross-correlation detecting method andchaotic detecting method, a new detecting system for the weak periodic pulse signal is constituted,in which the two methods can play respective preponderance. Theoretical analyses and simulationstudies have shown that the detecting system is very sensitive to the periodic pulse signal understrong noise background and has exceedingly powerful capability of suppressing complex noise.展开更多
This paper presents a quantitative method for automatic identification of human pulse signals. The idea is to start with the extraction of characteristic parameters and then to construct the recognition model based on...This paper presents a quantitative method for automatic identification of human pulse signals. The idea is to start with the extraction of characteristic parameters and then to construct the recognition model based on Bayesian networks. To identify depth, frequency and rhythm, several parameters are proposed. To distinguish the strength and shape, which cannot be represented by one or several parameters and are hard to recognize, the main time-domain feature parameters are computed based on the feature points of the pulse signal. Then the extracted parameters are taken as the input and five models for automatic pulse signal identification are constructed based on Bayesian networks. Experimental results demonstrate that the method is feasible and effective in recognizing depth, frequency, rhythm, strength and shape of pulse signals, which can be expected to facilitate the modernization of pulse diagnosis.展开更多
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result...The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.展开更多
The wavelet packet is presented as a new kind of multiscale analysis technique followed by Wavelet analysis. The fundamental and realization arithmetic of the wavelet packet analysis method are described in this paper...The wavelet packet is presented as a new kind of multiscale analysis technique followed by Wavelet analysis. The fundamental and realization arithmetic of the wavelet packet analysis method are described in this paper. A new application approach of the wavelet packed method to extract the feature of the pulse signal from energy distributing angle is expatiated. It is convenient for the microchip to process and judge by using the wavelet packet analysis method to make the pulse signals quantized and analyzed. Kinds of experiments are simulated in the lab, and the experiments prove that it is a convenient and accurate method to extract the feature of the pulse signal based on wavelet packed-energy spectrumanalysis.展开更多
In this paper, the problem of locally optimum detection of weak pulse signals in narrow-band non-Gaussian noise is discussed. A generalized model is proposed for locally optimum detectors (LOD) and the corresponding p...In this paper, the problem of locally optimum detection of weak pulse signals in narrow-band non-Gaussian noise is discussed. A generalized model is proposed for locally optimum detectors (LOD) and the corresponding physical meaning is explained. On the basis of this generalized model, the LOD structures are derived for detecting both coherent- and incoherent-pulse signals in narrow-band non-Gaussian noise. The asymptotic relative efficiency (ARE) due to Pitman is used to evaluate the performance of these LODs. Finally, numerical calculations are carried out for the AREs of these LODs and some valuable results are obtained.展开更多
The statistical distribution of natural phenomena is of great significance in studying the laws of nature. In order to study the statistical characteristics of a random pulse signal, a random process model is proposed...The statistical distribution of natural phenomena is of great significance in studying the laws of nature. In order to study the statistical characteristics of a random pulse signal, a random process model is proposed theoretically for better studying of the random law of measured results. Moreover, a simple random pulse signal generation and testing system is designed for studying the counting distributions of three typical objects including particles suspended in the air, standard particles, and background noise. Both normal and lognormal distribution fittings are used for analyzing the experimental results and testified by chi-square distribution fit test and correlation coefficient for comparison. In addition, the statistical laws of three typical objects and the relations between them are discussed in detail. The relation is also the non-integral dimension fractal relation of statistical distributions of different random laser scattering pulse signal groups.展开更多
Pulse signal recovery is to extract useful amplitude and time information from the pulse signal contaminated by noise. It is a great challenge to precisely recover the pulse signal in loud background noise. The conven...Pulse signal recovery is to extract useful amplitude and time information from the pulse signal contaminated by noise. It is a great challenge to precisely recover the pulse signal in loud background noise. The conventional approaches,which are mostly based on the distribution of the pulse energy spectrum,do not well determine the locations and shapes of the pulses. In this paper,we propose a time domain method to reconstruct pulse signals. In the proposed approach,a sparse representation model is established to deal with the issue of the pulse signal recovery under noise conditions. The corresponding problem based on the sparse optimization model is solved by a matching pursuit algorithm. Simulations and experiments validate the effectiveness of the proposed approach on pulse signal recovery.展开更多
Objective: To explore characteristic of pulse signal to distinguish patients with coronary heart diseases (CHD) from patients without CHD and healthy adults, and accordingly evaluate the potential role of pulse sig...Objective: To explore characteristic of pulse signal to distinguish patients with coronary heart diseases (CHD) from patients without CHD and healthy adults, and accordingly evaluate the potential role of pulse signal to diagnosis CHD. Methods: Totally 407 patients enrolled from 4 collaborating medical centers were assigned to a CHD group (205 patients) and a non-CHD group (202 patients). The healthy control group (62 adults) enrolled from Shanghai University of Traditional Chinese Medicine. Pulse signals were collected using the synchronous multiplex pulse signal acquisition system. The pulse signals were analyzed and extracted using Hilbert-Huang transformation (HHT) and time-domain, respectively. The time-domain parameters of pulse signal were processed by the analysis of variance (SNK test). Results: Special patterns in the CHD group pulse signal were found in this study: (1) time-domain parameters of pulse signal, h1 , h3, h4, h3/h1, t, t5/t4 were increased and w was wider; (2) 44% of C2 waves in HHT were chaotic and disordered and 72% of C3 waves were exhibited irregularly with average amplitude over 10 g-forces, which were all significantly different from controls. Conclusion: Characteristic wave and time-domain parameters of pulse signal were extracted using HHT and time-domain which could be served as a non-invasive approach for assessing patients with CHD.展开更多
According to the problem of cognitive ultra wide-band (UWB) spectrum sensing, a novel UWB pulse signal detection algorithm based on cumulative sum (CUSUM) test is proposed in this paper. Based on the analysis of t...According to the problem of cognitive ultra wide-band (UWB) spectrum sensing, a novel UWB pulse signal detection algorithm based on cumulative sum (CUSUM) test is proposed in this paper. Based on the analysis of the existing spectrum sensing schemes for cognitive UWB system, some obvious facts are obtained that it is difficult to detect UWB pulse signal with conventional spectrum sensing schemes, due to its low average signal to noise ratio (SNR), large bandwidth, and low duty ratio. In this paper the detection algorithm of signal distribution change, which is application of CUSUM test, is considered to be applied to cognitive UWB spectrum sensing. But CUSUM test request that the pre-change and the post-change distributions are i.i.d, which cannot be satisfied in the detection process of UWB pulse signal. Since there are two time domain descriptions on UWB pulse signal, namely one contains only noise and the other one contains pulse signal plus noise, the existing detection algorithm of signal distribution change cannot be directly applied to detect UWB pulse signal. Hence the uniform probability density function expression of UWB pulse signal is first deduced, then CUSUM test is applied to cognitive UWB spectrum sensing. The proposed algorithm is a time sequential detection algorithm, with low complexity and minimal detection delay, which is suitable to detect the low duty ratio signal. Its performance is evaluated through theoretical analysis and numerical simulations. It is shown that this algorithm outperforms the conventional energy detection algorithm and conquers SNR wall phenomenon.展开更多
Objective: To study the regulation of blood pulse volume via photoplethysmography (PPG) signal detected from toe, while the lower limb is passively raised in different height positions. Methods: Use a modified non-inv...Objective: To study the regulation of blood pulse volume via photoplethysmography (PPG) signal detected from toe, while the lower limb is passively raised in different height positions. Methods: Use a modified non-invasive PPG technique to detect the blood pulse signal on toe with infrared (IR) photo sensor. A protocol consisting of two postures, i.e., supine and 45° reclining, was designed to conduct laboratory trial in this study. During the period of performing the protocol of these postures, the lower limb was passively raised from the heights of 10 cm to 60 cm randomly and individually with sponge blocks underneath the foot. Results: In the supine posture, the higher the foot was passively raised, the more the blood PPG signal decreased. In the 45° reclining posture, the blood PPG signal increased at the beginning and then decreased in the foot height position from 10 cm to 60 cm. In both postures the normalized AC signal changes significantly while the normalized DC signal changes little. Conclusion: The toe PPG signals can obviously indicate the regulated blood volume change with the designated postural procedures due to the heart level position.展开更多
It is an efficient method to model ship radiated noise as quasi-periodic random sound pulse sequences. Based on the model, this paper discusses the characteristics change of ship noise after through shallow-water wave...It is an efficient method to model ship radiated noise as quasi-periodic random sound pulse sequences. Based on the model, this paper discusses the characteristics change of ship noise after through shallow-water waveguides. Theoretical analysis and numerical simulation show that random waveguides and multi-path effects can bring much additional transmission loss for the noise line spectra, demonstrating the instability of ship radiated noise line spectra to a certain extent, and providing some theoretical support for advanced studies of ship radiated noise.展开更多
A computer simulation method for pulsed Doppler signals from vortices was pro- posed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequenc...A computer simulation method for pulsed Doppler signals from vortices was pro- posed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequency waveform, the mean frequency waveform and the bandwidth waveform, were obtained using the short time Fourier analysis of those simulated signals. The relations were studied between several spectrum parameters obtained from these waveforms and given simulation conditions, such as the position and the size of the sample volume, the distance between two vortices, the free stream velocity and the maximum tangent velocity of the vortex. The sensitive parameters were found to detect vortices using the pulsed Doppler techniques.展开更多
Abnormal disturbances, s uch as sharp pulses, w ere observed by vertical pendulum tiltmeters in Wudu, Hanzhong and Ningshaan seismic stations on August 6, 2008.According to the time and spatial location of the anomali...Abnormal disturbances, s uch as sharp pulses, w ere observed by vertical pendulum tiltmeters in Wudu, Hanzhong and Ningshaan seismic stations on August 6, 2008.According to the time and spatial location of the anomalies,we build a"source precursor"propagator to calculate possible focal region by aid of quasi-Newton least squares and grid search methods. The calculated focal region is located at the aftershock area of the Wenchuan earthquake on the northern section of Longmenshan fault zone,which may be related to the 54km-away M S5. 0 Pingwu-Beichuan earthquake,with starting time of about thirty three hours before the earthquake.展开更多
Novel high-voltage, high-side and low-side power devices, whose control circuits are referred to as the tub, are proposed and investigated to reduce chip area and improve the reliability of high-voltage integrated cir...Novel high-voltage, high-side and low-side power devices, whose control circuits are referred to as the tub, are proposed and investigated to reduce chip area and improve the reliability of high-voltage integrated circuits. By using the tub circuit to control a branch circuit consisting of a PMOS and a resistor, a pulse signal is generated to control the low-side n-LDMOS after being processed by a low-voltage circuit. Thus, the high-voltage level-shifting circuit is not needed any more, and the parasitic effect of the conventional level-shifting circuit is eliminated. Moreover, the specific on-resistance of the proposed low-side device is reduced by more than 14.3% compared with the conventional one. In the meantime, integrated low-voltage power supplies for the low-voltage circuit and the tub circuit are also proposed. Simulations are performed with MEDICI and SPICE, and the results show that the expectant functions are achieved well.展开更多
In this paper, the problem of parameter estimation of the combined radar signal adopting chaotic pulse position modulation (CPPM) and linear frequency modulation (LFM), which can be widely used in electronic count...In this paper, the problem of parameter estimation of the combined radar signal adopting chaotic pulse position modulation (CPPM) and linear frequency modulation (LFM), which can be widely used in electronic countermeasures, is addressed. An approach is proposed to estimate the initial frequency and chirp rate of the combined signal by exploiting the second-order cyclostationarity of the intra-pulse signal. In addition, under the condition of the equal pulse width, the pulse repetition interval (PRI) of the combined signal is predicted using the low-order Volterra adaptive filter. Simulations demonstrate that the proposed cyclic autocorrelation Hough transform (CHT) algorithm is theoretically tolerant to additive white Gaussian noise. When the value of signal noise to ratio (SNR) is less than 4 dB, it can still estimate the intra-pulse parameters well. When SNR = 3 dB, a good prediction of the PRI sequence can be achieved by the Volterra adaptive filter algorithm, even only 100 training samples.展开更多
We propose and demonstrate a reconfigurable and single-shot incoherent optical signal processing system for chirped microwave signal compression, using a programmable optical filter and a multiwavelength laser(MWL). T...We propose and demonstrate a reconfigurable and single-shot incoherent optical signal processing system for chirped microwave signal compression, using a programmable optical filter and a multiwavelength laser(MWL). The system is implemented by temporally modulating a specially shaped MWL followed by a suitable linear dispersive medium. A microwave dispersion value up to 1.33 ns/GHz over several GHz bandwidth is achieved based on this approach. Here we demonstrate a singleshot compression for different linearly chirped microwave signals over several GHz bandwidth. In addition, the robustness of the proposed system when input RF signals are largely distorted is also discussed.展开更多
Time-frequency(TF)analysis(TFA)is one of the effective methods to deal with non-stationary signals.Due to their advantages,many experts and scholars have recently developed post-processing algorithms based on traditio...Time-frequency(TF)analysis(TFA)is one of the effective methods to deal with non-stationary signals.Due to their advantages,many experts and scholars have recently developed post-processing algorithms based on traditional TFA.Among them,shorttime Fourier transform(STFT)based post-processing algorithms have developed the fastest.However,these methods rely heavily on the window length selected in STFT,which has great influence on the post-processing algorithm.In this paper,a postprocessing algorithm for effectively processing pulse signals was proposed and called time-extracting S-transform(TEST).The time-domain extraction method based on S-transform avoids the influence of uncertain parameters.After comparing the performance of various TFA methods when processing analog signals,the proposed TEST can clearly show the pulse occurrence time under the premise of ensuring high TF aggregation.The actual signal proves that the method can be used for fault diagnosis of rolling bearings.展开更多
In this paper,a novel,small,and compact planar antenna for ultra-wideband(UWB)applications is proposed.The antenna is an extension of microstrip slot antenna technology.To achieve ultra-wideband characteristics,a tape...In this paper,a novel,small,and compact planar antenna for ultra-wideband(UWB)applications is proposed.The antenna is an extension of microstrip slot antenna technology.To achieve ultra-wideband characteristics,a tapered microstrip fork-shaped stub has been employed.A symmetric polygon wide slot has been placed on the antenna ground.The design was investigated numerically to obtain proper dimensions for the antenna and a prototype was constructed.The return loss,pattern and gain of the prototype antenna have been measured.The transient pulse signal fidelity has also been investigated by finite-difference time-domain(FDTD)method.Experimental results show that the proposed antenna design has promising characteristics for UWB applications.展开更多
文摘This paper analyses a key problem in the quantification of pulse diagnosis. Due to the subjectivity and fuzziness of pulse diagnosis,quantitative methods are needed. To extract the parameters of pulse signals,the prerequisite is to detect the corners of pulse signals correctly. Up to now,the pulse parameters are mostly acquired by marking the pulse corners manually,which is an obstacle to modernize pulse diagnosis. Therefore,a new automatic parameters extraction approach for pulse signals using wavelet transform is presented. The results testified that the method we proposed is feasible and effective and can detect corners of pulse signals accurately,which can be expected to facilitate the modernization of pulse diagnosis.
基金supported by the National Key R&D Project(No.2017YFF0106503)National Natural Science Foundation of China(Nos.11665001 and 41864007)。
文摘In the design of filter shaping circuits for nuclear pulse signals,inverting filter shaping circuits perform better than non-inverting filter shaping circuits.Because these circuits facilitate changing the phase of a pulse signal,they are widely used in processing nuclear pulse signals.In this study,the transfer functions of four types of inverting filter shaping circuits,namely the common inverting filter shaping,improved inverting filter shaping,multiple feedback low-pass filter shaping,and third-order multiple feedback low-pass filter shaping,in the Laplacian domain,are derived.We establish the numerical recursive function models and digitalize the four circuits,obtain the transfer functions in the Z domain,and analyze the filter performance and amplitude-frequency response characteristics in the frequency domain.Based on the actual nuclear pulse signal of the Si-PIN detector,we realize four types of inverting digital shaping.The results show that under the same shaping parameters,the common inverting digital shaping has better amplitude extraction characteristics,the third-order multiple feedback low-pass digital shaping has better noise suppression performance,and the multiple feedback digital shaping takes into account both pulse amplitude extraction and noise suppression performance.
文摘In this letter, with the synthesis of usual cross-correlation detecting method andchaotic detecting method, a new detecting system for the weak periodic pulse signal is constituted,in which the two methods can play respective preponderance. Theoretical analyses and simulationstudies have shown that the detecting system is very sensitive to the periodic pulse signal understrong noise background and has exceedingly powerful capability of suppressing complex noise.
基金Project (No. 20070593) supported by the Scientific Research Fund of Zhejiang Provincial Education Department, China
文摘This paper presents a quantitative method for automatic identification of human pulse signals. The idea is to start with the extraction of characteristic parameters and then to construct the recognition model based on Bayesian networks. To identify depth, frequency and rhythm, several parameters are proposed. To distinguish the strength and shape, which cannot be represented by one or several parameters and are hard to recognize, the main time-domain feature parameters are computed based on the feature points of the pulse signal. Then the extracted parameters are taken as the input and five models for automatic pulse signal identification are constructed based on Bayesian networks. Experimental results demonstrate that the method is feasible and effective in recognizing depth, frequency, rhythm, strength and shape of pulse signals, which can be expected to facilitate the modernization of pulse diagnosis.
基金supported by the Users with Excellence Program of the Hefei Science Center CAS (No. 2020HSC-UE012)
文摘The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
文摘The wavelet packet is presented as a new kind of multiscale analysis technique followed by Wavelet analysis. The fundamental and realization arithmetic of the wavelet packet analysis method are described in this paper. A new application approach of the wavelet packed method to extract the feature of the pulse signal from energy distributing angle is expatiated. It is convenient for the microchip to process and judge by using the wavelet packet analysis method to make the pulse signals quantized and analyzed. Kinds of experiments are simulated in the lab, and the experiments prove that it is a convenient and accurate method to extract the feature of the pulse signal based on wavelet packed-energy spectrumanalysis.
文摘In this paper, the problem of locally optimum detection of weak pulse signals in narrow-band non-Gaussian noise is discussed. A generalized model is proposed for locally optimum detectors (LOD) and the corresponding physical meaning is explained. On the basis of this generalized model, the LOD structures are derived for detecting both coherent- and incoherent-pulse signals in narrow-band non-Gaussian noise. The asymptotic relative efficiency (ARE) due to Pitman is used to evaluate the performance of these LODs. Finally, numerical calculations are carried out for the AREs of these LODs and some valuable results are obtained.
文摘The statistical distribution of natural phenomena is of great significance in studying the laws of nature. In order to study the statistical characteristics of a random pulse signal, a random process model is proposed theoretically for better studying of the random law of measured results. Moreover, a simple random pulse signal generation and testing system is designed for studying the counting distributions of three typical objects including particles suspended in the air, standard particles, and background noise. Both normal and lognormal distribution fittings are used for analyzing the experimental results and testified by chi-square distribution fit test and correlation coefficient for comparison. In addition, the statistical laws of three typical objects and the relations between them are discussed in detail. The relation is also the non-integral dimension fractal relation of statistical distributions of different random laser scattering pulse signal groups.
基金Supported by the National Natural Science Foundation of China(61501385)Science and Technology Planning Project of Sichuan Province,China(2016JY0242,2016GZ0210)Foundation of Southwest University of Science and Technology(15kftk02,15kffk01)
文摘Pulse signal recovery is to extract useful amplitude and time information from the pulse signal contaminated by noise. It is a great challenge to precisely recover the pulse signal in loud background noise. The conventional approaches,which are mostly based on the distribution of the pulse energy spectrum,do not well determine the locations and shapes of the pulses. In this paper,we propose a time domain method to reconstruct pulse signals. In the proposed approach,a sparse representation model is established to deal with the issue of the pulse signal recovery under noise conditions. The corresponding problem based on the sparse optimization model is solved by a matching pursuit algorithm. Simulations and experiments validate the effectiveness of the proposed approach on pulse signal recovery.
基金Supported by the National 973 Basic Research and Development Program(No.2003CB517108)Supported by the National Natural Science Foundation of China(No.30600796,81373555,and 81403273)
文摘Objective: To explore characteristic of pulse signal to distinguish patients with coronary heart diseases (CHD) from patients without CHD and healthy adults, and accordingly evaluate the potential role of pulse signal to diagnosis CHD. Methods: Totally 407 patients enrolled from 4 collaborating medical centers were assigned to a CHD group (205 patients) and a non-CHD group (202 patients). The healthy control group (62 adults) enrolled from Shanghai University of Traditional Chinese Medicine. Pulse signals were collected using the synchronous multiplex pulse signal acquisition system. The pulse signals were analyzed and extracted using Hilbert-Huang transformation (HHT) and time-domain, respectively. The time-domain parameters of pulse signal were processed by the analysis of variance (SNK test). Results: Special patterns in the CHD group pulse signal were found in this study: (1) time-domain parameters of pulse signal, h1 , h3, h4, h3/h1, t, t5/t4 were increased and w was wider; (2) 44% of C2 waves in HHT were chaotic and disordered and 72% of C3 waves were exhibited irregularly with average amplitude over 10 g-forces, which were all significantly different from controls. Conclusion: Characteristic wave and time-domain parameters of pulse signal were extracted using HHT and time-domain which could be served as a non-invasive approach for assessing patients with CHD.
基金supported by the Aviation Science Fund (20095596014)
文摘According to the problem of cognitive ultra wide-band (UWB) spectrum sensing, a novel UWB pulse signal detection algorithm based on cumulative sum (CUSUM) test is proposed in this paper. Based on the analysis of the existing spectrum sensing schemes for cognitive UWB system, some obvious facts are obtained that it is difficult to detect UWB pulse signal with conventional spectrum sensing schemes, due to its low average signal to noise ratio (SNR), large bandwidth, and low duty ratio. In this paper the detection algorithm of signal distribution change, which is application of CUSUM test, is considered to be applied to cognitive UWB spectrum sensing. But CUSUM test request that the pre-change and the post-change distributions are i.i.d, which cannot be satisfied in the detection process of UWB pulse signal. Since there are two time domain descriptions on UWB pulse signal, namely one contains only noise and the other one contains pulse signal plus noise, the existing detection algorithm of signal distribution change cannot be directly applied to detect UWB pulse signal. Hence the uniform probability density function expression of UWB pulse signal is first deduced, then CUSUM test is applied to cognitive UWB spectrum sensing. The proposed algorithm is a time sequential detection algorithm, with low complexity and minimal detection delay, which is suitable to detect the low duty ratio signal. Its performance is evaluated through theoretical analysis and numerical simulations. It is shown that this algorithm outperforms the conventional energy detection algorithm and conquers SNR wall phenomenon.
文摘Objective: To study the regulation of blood pulse volume via photoplethysmography (PPG) signal detected from toe, while the lower limb is passively raised in different height positions. Methods: Use a modified non-invasive PPG technique to detect the blood pulse signal on toe with infrared (IR) photo sensor. A protocol consisting of two postures, i.e., supine and 45° reclining, was designed to conduct laboratory trial in this study. During the period of performing the protocol of these postures, the lower limb was passively raised from the heights of 10 cm to 60 cm randomly and individually with sponge blocks underneath the foot. Results: In the supine posture, the higher the foot was passively raised, the more the blood PPG signal decreased. In the 45° reclining posture, the blood PPG signal increased at the beginning and then decreased in the foot height position from 10 cm to 60 cm. In both postures the normalized AC signal changes significantly while the normalized DC signal changes little. Conclusion: The toe PPG signals can obviously indicate the regulated blood volume change with the designated postural procedures due to the heart level position.
基金supported by the National Natural Science Foundation of China(11174314,11474301,11204345)the State Key Laboratory of Acoustics,Chinese Academy of Sciences(SKLA201502)
文摘It is an efficient method to model ship radiated noise as quasi-periodic random sound pulse sequences. Based on the model, this paper discusses the characteristics change of ship noise after through shallow-water waveguides. Theoretical analysis and numerical simulation show that random waveguides and multi-path effects can bring much additional transmission loss for the noise line spectra, demonstrating the instability of ship radiated noise line spectra to a certain extent, and providing some theoretical support for advanced studies of ship radiated noise.
基金This work is supported by the Outstanding Young Teacher Funds of Chinese Ministry of Education.
文摘A computer simulation method for pulsed Doppler signals from vortices was pro- posed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequency waveform, the mean frequency waveform and the bandwidth waveform, were obtained using the short time Fourier analysis of those simulated signals. The relations were studied between several spectrum parameters obtained from these waveforms and given simulation conditions, such as the position and the size of the sample volume, the distance between two vortices, the free stream velocity and the maximum tangent velocity of the vortex. The sensitive parameters were found to detect vortices using the pulsed Doppler techniques.
基金funded by the Shaanxi Natural Science Foundation as a Subproject of the Project Entitled "Research on Origin of the Large-amplitude Deformation Anomaly in Hancheng and Qianxian Seismic Stations and the Seismic Hazard of Strong Earthquake in the Guanzhong Region"(2014JM2-4039)
文摘Abnormal disturbances, s uch as sharp pulses, w ere observed by vertical pendulum tiltmeters in Wudu, Hanzhong and Ningshaan seismic stations on August 6, 2008.According to the time and spatial location of the anomalies,we build a"source precursor"propagator to calculate possible focal region by aid of quasi-Newton least squares and grid search methods. The calculated focal region is located at the aftershock area of the Wenchuan earthquake on the northern section of Longmenshan fault zone,which may be related to the 54km-away M S5. 0 Pingwu-Beichuan earthquake,with starting time of about thirty three hours before the earthquake.
基金supported by the 2011 Ph.D.Programs Foundation of the Ministry of Education of China(No.20110185110003)
文摘Novel high-voltage, high-side and low-side power devices, whose control circuits are referred to as the tub, are proposed and investigated to reduce chip area and improve the reliability of high-voltage integrated circuits. By using the tub circuit to control a branch circuit consisting of a PMOS and a resistor, a pulse signal is generated to control the low-side n-LDMOS after being processed by a low-voltage circuit. Thus, the high-voltage level-shifting circuit is not needed any more, and the parasitic effect of the conventional level-shifting circuit is eliminated. Moreover, the specific on-resistance of the proposed low-side device is reduced by more than 14.3% compared with the conventional one. In the meantime, integrated low-voltage power supplies for the low-voltage circuit and the tub circuit are also proposed. Simulations are performed with MEDICI and SPICE, and the results show that the expectant functions are achieved well.
基金supported by the National Natural Science Foundation of China under Grant 61172116
文摘In this paper, the problem of parameter estimation of the combined radar signal adopting chaotic pulse position modulation (CPPM) and linear frequency modulation (LFM), which can be widely used in electronic countermeasures, is addressed. An approach is proposed to estimate the initial frequency and chirp rate of the combined signal by exploiting the second-order cyclostationarity of the intra-pulse signal. In addition, under the condition of the equal pulse width, the pulse repetition interval (PRI) of the combined signal is predicted using the low-order Volterra adaptive filter. Simulations demonstrate that the proposed cyclic autocorrelation Hough transform (CHT) algorithm is theoretically tolerant to additive white Gaussian noise. When the value of signal noise to ratio (SNR) is less than 4 dB, it can still estimate the intra-pulse parameters well. When SNR = 3 dB, a good prediction of the PRI sequence can be achieved by the Volterra adaptive filter algorithm, even only 100 training samples.
基金supported by research grants from NSERC(Canada)agenciesalso partly supported by the National Natural Science Foundation of China(61522509,61377002 and 61090391)+2 种基金Beijing Natural Science Foundation(4152052)the National High-Tech Research and Development Program of China(2015AA017102)M.L.was supported partly by the Thousand Young Talent Program
文摘We propose and demonstrate a reconfigurable and single-shot incoherent optical signal processing system for chirped microwave signal compression, using a programmable optical filter and a multiwavelength laser(MWL). The system is implemented by temporally modulating a specially shaped MWL followed by a suitable linear dispersive medium. A microwave dispersion value up to 1.33 ns/GHz over several GHz bandwidth is achieved based on this approach. Here we demonstrate a singleshot compression for different linearly chirped microwave signals over several GHz bandwidth. In addition, the robustness of the proposed system when input RF signals are largely distorted is also discussed.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51775005 and 51675009)
文摘Time-frequency(TF)analysis(TFA)is one of the effective methods to deal with non-stationary signals.Due to their advantages,many experts and scholars have recently developed post-processing algorithms based on traditional TFA.Among them,shorttime Fourier transform(STFT)based post-processing algorithms have developed the fastest.However,these methods rely heavily on the window length selected in STFT,which has great influence on the post-processing algorithm.In this paper,a postprocessing algorithm for effectively processing pulse signals was proposed and called time-extracting S-transform(TEST).The time-domain extraction method based on S-transform avoids the influence of uncertain parameters.After comparing the performance of various TFA methods when processing analog signals,the proposed TEST can clearly show the pulse occurrence time under the premise of ensuring high TF aggregation.The actual signal proves that the method can be used for fault diagnosis of rolling bearings.
基金supported by the National Natural Science Foundation of China(Grant Nos.60432040 and 60471046).
文摘In this paper,a novel,small,and compact planar antenna for ultra-wideband(UWB)applications is proposed.The antenna is an extension of microstrip slot antenna technology.To achieve ultra-wideband characteristics,a tapered microstrip fork-shaped stub has been employed.A symmetric polygon wide slot has been placed on the antenna ground.The design was investigated numerically to obtain proper dimensions for the antenna and a prototype was constructed.The return loss,pattern and gain of the prototype antenna have been measured.The transient pulse signal fidelity has also been investigated by finite-difference time-domain(FDTD)method.Experimental results show that the proposed antenna design has promising characteristics for UWB applications.