Analytical solution is obtained to predict the contaminant concentration with presence and absence of pollution source in finite aquifer subject to constant point source concentration. A longitudinal dispersion along ...Analytical solution is obtained to predict the contaminant concentration with presence and absence of pollution source in finite aquifer subject to constant point source concentration. A longitudinal dispersion along unsteady groundwater flow in homogeneous and finite aquifer is considered which is initially solute free that is, aquifer is supposed to be clean. The constant source concentration in intermediate portion of the aquifer system is considered with pulse type boundary condition and at the other end of the aquifer, concentration gradient is supposed to be zero. The Laplace Transformation Technique (LTT) is used to obtain the analytical solution of the formulated solute transport model with suitable initial and boundary conditions. The time varying velocities are considered. Analytical solutions are perhaps most useful for benchmarking the numerical codes and models. It may be used as the preliminary predictive tools for groundwater management.展开更多
Objectives: To evaluate the association of diastolic function of the left ventricle with flowme-diated dilatation (FMD) in uncomplicated Type 2 diabetes mellitus patients. Methods: Eighty-two uncomplicated Type 2 diab...Objectives: To evaluate the association of diastolic function of the left ventricle with flowme-diated dilatation (FMD) in uncomplicated Type 2 diabetes mellitus patients. Methods: Eighty-two uncomplicated Type 2 diabetic patients were examined by pulse and tissue Doppler echocardiography and FMD of brachial artery. The patients were divided into 2 groups according to the size of the left ventricular relaxation parameter—E’. Results: The average age of the patients was 61 ± 6 years. FMD was 5.0 ± 1.8% in 41 patients with E’ from 3 to 7.4 cm/s (mean 6 cm/s) comparing to 5.1 ± 1.9% (p = 0.96) in 41 patients with E’ from 7.5 to 10.9 cm/s (mean 8.9 cm/s). E/E’ was 11.2 ± 2.3 in the group with lower E’ and 9.1 ± 1.6 in the group with higher E’ (p 0.001). Linear negative correlation was found between E/E’ and FMD for the patients with E’ from 3 to 7.4 cm/s (R2 = 0.131;p = 0.025) but not for the group of patients with the higher E’. The significant association between FMD and E/E’ was confirmed by multivariate analysis ((Rc)2 = 0.233;p 0.05). Conclusion: FMD has no impact on the left ventricular relaxation. However FMD is negatively associated with E/E’ in Type 2 diabetic patients who have low E’ as a sign of an impaired early relaxation.展开更多
OBJECTIVE:To analyze the Doppler ultrasound blood flow of Renying(carotid artery)pulse,Cunkou(radial artery)pulse,and Fuyang(anterior tibial artery)pulse in the normal group and the functional constipation with gastro...OBJECTIVE:To analyze the Doppler ultrasound blood flow of Renying(carotid artery)pulse,Cunkou(radial artery)pulse,and Fuyang(anterior tibial artery)pulse in the normal group and the functional constipation with gastrointestinal heat(FCGH)group,and to compare and explore the differences of Renying,Cunkou and Fuyang pulses.METHODS:Sixty normal subjects and 60 patients with gastrointestinal heat constipation were collected in the department of ultrasound,Beijing Anzhen Hospital,Capital Medical University.Doppler ultrasound was used to observe the blood flow indexes including maximum systolic velocity(Vp),maximum diastolic velocity(Vd),mean velocity(Vm),pulse index(PI),resistance index(RI),vascular diameter(D),and circulation blood flow cycle(ET)of Renying pulse,Cunkou pulse and Fuyang pulse in the normal group and patients with gastrointestinal heat constipation.The differences of these three pulses were compared between the normal group and the FCGH group.RESULTS:The PI,Vp,Vm,RI,and D of the three pulses in the normal group were statistically significant different(P<0.01).In the comparison of Doppler flow diagram of three pulses in the FCGH group,there were significant differences in PI,Vd,Vp,Vm,RI,and D(P<0.01).CONCLUSION:Under normal conditions,the indexes of Renying pulse Doppler flow diagram,Cunkou pulse Doppler flow diagram,and Fuyang pulse Doppler flow diagram are significantly different.In the FCGH group,most of the indexes of Renying pulse Doppler flow diagram,Cunkou pulse Doppler flow diagram,and Fuyang pulse Doppler flow diagram are different.This result verified the necessity of simultaneous examinations of all Renying,Cunkou,and Fuyang pulses in modern Chinese medicine.展开更多
文摘Analytical solution is obtained to predict the contaminant concentration with presence and absence of pollution source in finite aquifer subject to constant point source concentration. A longitudinal dispersion along unsteady groundwater flow in homogeneous and finite aquifer is considered which is initially solute free that is, aquifer is supposed to be clean. The constant source concentration in intermediate portion of the aquifer system is considered with pulse type boundary condition and at the other end of the aquifer, concentration gradient is supposed to be zero. The Laplace Transformation Technique (LTT) is used to obtain the analytical solution of the formulated solute transport model with suitable initial and boundary conditions. The time varying velocities are considered. Analytical solutions are perhaps most useful for benchmarking the numerical codes and models. It may be used as the preliminary predictive tools for groundwater management.
文摘Objectives: To evaluate the association of diastolic function of the left ventricle with flowme-diated dilatation (FMD) in uncomplicated Type 2 diabetes mellitus patients. Methods: Eighty-two uncomplicated Type 2 diabetic patients were examined by pulse and tissue Doppler echocardiography and FMD of brachial artery. The patients were divided into 2 groups according to the size of the left ventricular relaxation parameter—E’. Results: The average age of the patients was 61 ± 6 years. FMD was 5.0 ± 1.8% in 41 patients with E’ from 3 to 7.4 cm/s (mean 6 cm/s) comparing to 5.1 ± 1.9% (p = 0.96) in 41 patients with E’ from 7.5 to 10.9 cm/s (mean 8.9 cm/s). E/E’ was 11.2 ± 2.3 in the group with lower E’ and 9.1 ± 1.6 in the group with higher E’ (p 0.001). Linear negative correlation was found between E/E’ and FMD for the patients with E’ from 3 to 7.4 cm/s (R2 = 0.131;p = 0.025) but not for the group of patients with the higher E’. The significant association between FMD and E/E’ was confirmed by multivariate analysis ((Rc)2 = 0.233;p 0.05). Conclusion: FMD has no impact on the left ventricular relaxation. However FMD is negatively associated with E/E’ in Type 2 diabetic patients who have low E’ as a sign of an impaired early relaxation.
基金Supported by the Fundamental Research Funds for the Central Public Welfare Research Institutes:Theoretical Study of Combination of of Facial Color and Pulses Mode in Traditional Chinese Medicine(No.KJ-202013),Objective Study of“Wei Qi”in Pulse Based on Color Doppler Flow Imaging(CDFI)Technology(No.YZ-202124)。
文摘OBJECTIVE:To analyze the Doppler ultrasound blood flow of Renying(carotid artery)pulse,Cunkou(radial artery)pulse,and Fuyang(anterior tibial artery)pulse in the normal group and the functional constipation with gastrointestinal heat(FCGH)group,and to compare and explore the differences of Renying,Cunkou and Fuyang pulses.METHODS:Sixty normal subjects and 60 patients with gastrointestinal heat constipation were collected in the department of ultrasound,Beijing Anzhen Hospital,Capital Medical University.Doppler ultrasound was used to observe the blood flow indexes including maximum systolic velocity(Vp),maximum diastolic velocity(Vd),mean velocity(Vm),pulse index(PI),resistance index(RI),vascular diameter(D),and circulation blood flow cycle(ET)of Renying pulse,Cunkou pulse and Fuyang pulse in the normal group and patients with gastrointestinal heat constipation.The differences of these three pulses were compared between the normal group and the FCGH group.RESULTS:The PI,Vp,Vm,RI,and D of the three pulses in the normal group were statistically significant different(P<0.01).In the comparison of Doppler flow diagram of three pulses in the FCGH group,there were significant differences in PI,Vd,Vp,Vm,RI,and D(P<0.01).CONCLUSION:Under normal conditions,the indexes of Renying pulse Doppler flow diagram,Cunkou pulse Doppler flow diagram,and Fuyang pulse Doppler flow diagram are significantly different.In the FCGH group,most of the indexes of Renying pulse Doppler flow diagram,Cunkou pulse Doppler flow diagram,and Fuyang pulse Doppler flow diagram are different.This result verified the necessity of simultaneous examinations of all Renying,Cunkou,and Fuyang pulses in modern Chinese medicine.