A test bench of ABS/ASR integrated hydraulic system is developed by using pulse-width modulation (PWM) technology. The effective duty ratio range of ABS outlet valve has been tested in PWM control. With 50 Hz carrie...A test bench of ABS/ASR integrated hydraulic system is developed by using pulse-width modulation (PWM) technology. The effective duty ratio range of ABS outlet valve has been tested in PWM control. With 50 Hz carrier wave frequency, the tests are performed to determine the correspondence between duty ratio and the wheel cylinder pressure variation. The duty ratio range of ABS outlet valve in PWM control is determined and an experimental model of pressure reduction velocity (PRV) of wheel cylinder using PWM control is established. By comparison and test of the experimental model and realization of controlling the duty ratio of ABS outlet valves, the fine regulation of wheel cylinder PRV is realized in the working of ABS/ASR braking regulation, which is important and valuable to the improvement of the ABS/ASR controlling effect.展开更多
In order to output sine wave with small degree of distortion and improve stability,a type of inverter power supply is designed based on harmonic elimination pulse-width modulation(PWM)control.The rectifier and filter ...In order to output sine wave with small degree of distortion and improve stability,a type of inverter power supply is designed based on harmonic elimination pulse-width modulation(PWM)control.The rectifier and filter are added to input circuit of the inverter.Single-phrase full-bridge inverter performs the function of converting direct current into alternating current(DC/AC).In the control circuit,single chip micyoco(SCM)AT89C2051 is used for main control chip to accomplish the hardware design of the control system.A given value of output frequency of the inverter is input in the way of coding.According to the output frequency code which is read,SCM AT89C2051 defined harmonic elimination PWM control data which will be selected.Through internal timing control,the switches are switched under this provision of PWM control data.Then the driving signals of the switches in the inverter are output from I/O of SCM AT89C2051 to realize harmonic elimination PWM control.The results show that adding Newton homotopic algorithm of harmonic elimination PWM control to corresponding software of the control system can make the quality of output voltage of the inverter higher and it will have broad application prospects.展开更多
In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection sho...In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.展开更多
This study uses the smart phone with the Android system to construct a cloud-side smart switch system in the client-server architecture with the Android open platform system, using microprocessors(MCU 16F690) as the t...This study uses the smart phone with the Android system to construct a cloud-side smart switch system in the client-server architecture with the Android open platform system, using microprocessors(MCU 16F690) as the thermostat controller and combined with Raspberry Pi. The computing technology extends the control of the constant temperature from the local to the cloud, allowing the user to view the temperature status recorded by the cloud server using the smart phone application(App) or web browser. It can even remotely control the heating power of the smart switch for the heating device in the Internet control environment and use the proportional-integral-derivative(PID) control and the pulse-width modulation(PWM) technology to achieve intelligent constant temperature control.The proposed control system uses the expert PID control as the core to calculate the duty cycle of the PWM signal to control the power output of the smart switch for the constant temperature water tank. The experiment results verify the effectiveness of the proposed system.展开更多
This paper presents a novel dual-mode step-up (boost) DC/DC converter. Pulse-frequency modulation (PFM) is used to improve the efficiency at light load. This converter can operate between pulse-width modulation (...This paper presents a novel dual-mode step-up (boost) DC/DC converter. Pulse-frequency modulation (PFM) is used to improve the efficiency at light load. This converter can operate between pulse-width modulation (PWM) and pulse-frequency modulation. The converter will operate in PFM mode at light load and in PWM mode at heavy load. The maximum conversion efficiency of this converter is 96%. The conversion efficiency is greatly improved when load current is below 100 mA. Additionally, a soft-start circuit and a variable-sawtooth frequency circuit are proposed in this paper. The former is used to avoid the large switching current at the start up of the converter and the latter is utilized to reduce the EMI of the converter.展开更多
基金the National Natural Science Foundation of China (50122155)
文摘A test bench of ABS/ASR integrated hydraulic system is developed by using pulse-width modulation (PWM) technology. The effective duty ratio range of ABS outlet valve has been tested in PWM control. With 50 Hz carrier wave frequency, the tests are performed to determine the correspondence between duty ratio and the wheel cylinder pressure variation. The duty ratio range of ABS outlet valve in PWM control is determined and an experimental model of pressure reduction velocity (PRV) of wheel cylinder using PWM control is established. By comparison and test of the experimental model and realization of controlling the duty ratio of ABS outlet valves, the fine regulation of wheel cylinder PRV is realized in the working of ABS/ASR braking regulation, which is important and valuable to the improvement of the ABS/ASR controlling effect.
文摘In order to output sine wave with small degree of distortion and improve stability,a type of inverter power supply is designed based on harmonic elimination pulse-width modulation(PWM)control.The rectifier and filter are added to input circuit of the inverter.Single-phrase full-bridge inverter performs the function of converting direct current into alternating current(DC/AC).In the control circuit,single chip micyoco(SCM)AT89C2051 is used for main control chip to accomplish the hardware design of the control system.A given value of output frequency of the inverter is input in the way of coding.According to the output frequency code which is read,SCM AT89C2051 defined harmonic elimination PWM control data which will be selected.Through internal timing control,the switches are switched under this provision of PWM control data.Then the driving signals of the switches in the inverter are output from I/O of SCM AT89C2051 to realize harmonic elimination PWM control.The results show that adding Newton homotopic algorithm of harmonic elimination PWM control to corresponding software of the control system can make the quality of output voltage of the inverter higher and it will have broad application prospects.
文摘In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.
文摘This study uses the smart phone with the Android system to construct a cloud-side smart switch system in the client-server architecture with the Android open platform system, using microprocessors(MCU 16F690) as the thermostat controller and combined with Raspberry Pi. The computing technology extends the control of the constant temperature from the local to the cloud, allowing the user to view the temperature status recorded by the cloud server using the smart phone application(App) or web browser. It can even remotely control the heating power of the smart switch for the heating device in the Internet control environment and use the proportional-integral-derivative(PID) control and the pulse-width modulation(PWM) technology to achieve intelligent constant temperature control.The proposed control system uses the expert PID control as the core to calculate the duty cycle of the PWM signal to control the power output of the smart switch for the constant temperature water tank. The experiment results verify the effectiveness of the proposed system.
基金the National Science Council of Taiwan, China, under Grant No. NSC 95-2221-E-305010.
文摘This paper presents a novel dual-mode step-up (boost) DC/DC converter. Pulse-frequency modulation (PFM) is used to improve the efficiency at light load. This converter can operate between pulse-width modulation (PWM) and pulse-frequency modulation. The converter will operate in PFM mode at light load and in PWM mode at heavy load. The maximum conversion efficiency of this converter is 96%. The conversion efficiency is greatly improved when load current is below 100 mA. Additionally, a soft-start circuit and a variable-sawtooth frequency circuit are proposed in this paper. The former is used to avoid the large switching current at the start up of the converter and the latter is utilized to reduce the EMI of the converter.