期刊文献+
共找到1,567篇文章
< 1 2 79 >
每页显示 20 50 100
Atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction
1
作者 Ding-Han Zhu Xiong Zhang +3 位作者 Xiao-Qiang Li Peng Li Yan-Bin Wang Shuang Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期40-52,共13页
In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detect... In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detector following atmospheric transmission.To quantitatively analyze the effects of different satellite detection altitudes,burst heights,and transmission angles on the physical processes of X-ray transport and energy fluence,we developed an atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction.The proposed method is an improvement over the traditional analytical method that only computes direct-transmission X-rays.The traditional analytical method exhibits a maximum relative error of 67.79% compared with the Monte Carlo method.Our improved method reduces this error to within 10% under the same conditions,even reaching 1% in certain scenarios.Moreover,its computation time is 48,000 times faster than that of the Monte Carlo method.These results have important theoretical significance and engineering application value for designing satellite-borne nuclear detonation pulsed X-ray detectors,inverting nuclear detonation source terms,and assessing ionospheric effects. 展开更多
关键词 High-altitude nuclear detonation Atmospheric transmission pulsed x-rays Scattering correction Analytical method Monte Carlo method
下载PDF
Insights into the hydrogen evolution reaction in vanadium redox flow batteries:A synchrotron radiation based X-ray imaging study
2
作者 Kerstin Köble Alexey Ershov +7 位作者 Kangjun Duan Monja Schilling Alexander Rampf Angelica Cecilia TomášFaragó Marcus Zuber Tilo Baumbach Roswitha Zeis 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期132-144,共13页
The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble fo... The parasitic hydrogen evolution reaction(HER)in the negative half-cell of vanadium redox flow batteries(VRFBs)causes severe efficiency losses.Thus,a deeper understanding of this process and the accompanying bubble formation is crucial.This benchmarking study locally analyzes the bubble distribution in thick,porous electrodes for the first time using deep learning-based image segmentation of synchrotron X-ray micro-tomograms.Each large three-dimensional data set was processed precisely in less than one minute while minimizing human errors and pointing out areas of increased HER activity in VRFBs.The study systematically varies the electrode potential and material,concluding that more negative electrode potentials of-200 m V vs.reversible hydrogen electrode(RHE)and lower cause more substantial bubble formation,resulting in bubble fractions of around 15%–20%in carbon felt electrodes.Contrarily,the bubble fractions stay only around 2%in an electrode combining carbon felt and carbon paper.The detected areas with high HER activity,such as the border subregion with more than 30%bubble fraction in carbon felt electrodes,the cutting edges,and preferential spots in the electrode bulk,are potential-independent and suggest that larger electrodes with a higher bulk-to-border ratio might reduce HER-related performance losses.The described combination of electrochemical measurements,local X-ray microtomography,AI-based segmentation,and 3D morphometric analysis is a powerful and novel approach for local bubble analysis in three-dimensional porous electrodes,providing an essential toolkit for a broad community working on bubble-generating electrochemical systems. 展开更多
关键词 Vanadium redox flow battery Synchrotron x-ray imaging Tomography Hydrogen evolution reaction Gas bubbles Deep learning
下载PDF
Anisotropy of Trabecular Bone from Ultra-Distal Radius Digital X-Ray Imaging: Effects on Bone Mineral Density and Age
3
作者 Jian-Feng Chen 《Open Journal of Radiology》 2024年第1期14-23,共10页
Background: When applied to trabecular bone X-ray images, the anisotropic properties of trabeculae located at ultra-distal radius were investigated by using the trabecular bone scores (TBS) calculated along directions... Background: When applied to trabecular bone X-ray images, the anisotropic properties of trabeculae located at ultra-distal radius were investigated by using the trabecular bone scores (TBS) calculated along directions parallel and perpendicular to the forearm. Methodology: Data from more than two hundred subjects were studied retrospectively. A DXA (GE Lunar Prodigy) scan of the forearm was performed on each subject to measure the bone mineral density (BMD) value at the location of ultra-distal radius, and an X-ray digital image of the same forearm was taken on the same day. The values of trabecular bone score along the direction perpendicular to the forearm, TBS<sub>x</sub>, and along the direction parallel to the forearm, TBS<sub>y</sub>, were calculated respectively. The statistics of TBS<sub>x</sub> and TBS<sub>y</sub> were calculated, and the anisotropy of the trabecular bone, which was defined as the ratio of TBS<sub>y</sub> to TBS<sub>x</sub> and changed with subjects’ BMD and age, was reported and analyzed. Results: The results show that the correlation coefficient between TBS<sub>x</sub> and TBS<sub>y</sub> was 0.72 (p BMD and age was reported. The results showed that decreased trabecular bone anisotropy was associated with deceased BMD and increased age in the subject group. Conclusions: This study shows that decreased trabecular bone anisotropy was associated with decreased BMD and increased age. 展开更多
关键词 ANISOTROPY Trabecular Bone Score Bone Mineral Density Ultra-Distal Radius Digital x-ray image
下载PDF
The Soft X-ray Imager(SXI)on the SMILE Mission 被引量:4
4
作者 S.Sembay A.L.Alme +83 位作者 D.Agnolon T.Arnold A.Beardmore A.Belén Balado Margeli C.Bicknell C.Bouldin G.Branduardi-Raymont T.Crawford J.P.Breuer T.Buggey G.Butcher R.Canchal J.A.Carter A.Cheney Y.Collado-Vega H.Connor T.Crawford N.Eaton C.Feldman C.Forsyth T.Frantzen G.Galgóczi J.Garcia G.Y.Genov C.Gordillo H-P.Gröbelbauer M.Guedel Y.Guo M.Hailey D.Hall R.Hampson J.Hasiba O.Hetherington A.Holland S-Y.Hsieh M.W.J.Hubbard H.Jeszenszky M.Jones T.Kennedy K.Koch-Mehrin S.Kögl S.Krucker K.D.Kuntz C.Lakin G.Laky O.Lylund A.Martindale J.Miguel Mas Hesse R.Nakamura K.Oksavik N.Østgaard H.Ottacher R.Ottensamer C.Pagani S.Parsons P.Patel J.Pearson G.Peikert F.S.Porter T.Pouliantis B.H.Qureshi W.Raab G.Randal A.M.Read N.M.M.Roque M.E.Rostad C.Runciman S.Sachdev A.Samsonov M.Soman D.Sibeck S.Smit J.Søndergaard R.Speight S.Stavland M.Steller TianRan Sun J.Thornhill W.Thomas K.Ullaland B.Walsh D.Walton C.Wang S.Yang 《Earth and Planetary Physics》 EI CSCD 2024年第1期5-14,共10页
The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese... The Soft X-ray Imager(SXI)is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission.SMILE is a joint science mission between the European Space Agency(ESA)and the Chinese Academy of Sciences(CAS)and is due for launch in 2025.SXI is a compact X-ray telescope with a wide field-of-view(FOV)capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit.SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange(SWCX)process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere.SWCX provides a mechanism for boundary detection within the magnetosphere,such as the position of Earth’s magnetopause,because the solar wind heavy ions have a very low density in regions of closed magnetic field lines.The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours.SXI is led by the University of Leicester in the United Kingdom(UK)with collaborating organisations on hardware,software and science support within the UK,Europe,China and the United States. 展开更多
关键词 Soft x-ray imaging micropore optics large area CCD
下载PDF
SMILE soft X-ray Imager flight model CCD370 pre-flight device characterisation 被引量:1
5
作者 S.Parsons D.J.Hall +4 位作者 O.Hetherington T.W.Buggey T.Arnold M.W.J.Hubbard A.Holland 《Earth and Planetary Physics》 EI CSCD 2024年第1期25-38,共14页
Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the sof... Throughout the SMILE mission the satellite will be bombarded by radiation which gradually damages the focal plane devices and degrades their performance.In order to understand the changes of the CCD370s within the soft X-ray Imager,an initial characterisation of the devices has been carried out to give a baseline performance level.Three CCDs have been characterised,the two flight devices and the flight spa re.This has been carried out at the Open University in a bespo ke cleanroom measure ment facility.The results show that there is a cluster of bright pixels in the flight spa re which increases in size with tempe rature.However at the nominal ope rating tempe rature(-120℃) it is within the procure ment specifications.Overall,the devices meet the specifications when ope rating at -120℃ in 6 × 6 binned frame transfer science mode.The se rial charge transfer inefficiency degrades with temperature in full frame mode.However any charge losses are recovered when binning/frame transfer is implemented. 展开更多
关键词 CCD soft x-ray imager characterisation SMILE
下载PDF
Using restored two-dimensional X-ray images to reconstruct the three-dimensional magnetopause 被引量:1
6
作者 RongCong Wang JiaQi Wang +3 位作者 DaLin Li TianRan Sun XiaoDong Peng YiHong Guo 《Earth and Planetary Physics》 EI CSCD 2024年第1期133-154,共22页
Astronomical imaging technologies are basic tools for the exploration of the universe,providing basic data for the research of astronomy and space physics.The Soft X-ray Imager(SXI)carried by the Solar wind Magnetosph... Astronomical imaging technologies are basic tools for the exploration of the universe,providing basic data for the research of astronomy and space physics.The Soft X-ray Imager(SXI)carried by the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)aims to capture two-dimensional(2-D)images of the Earth’s magnetosheath by using soft X-ray imaging.However,the observed 2-D images are affected by many noise factors,destroying the contained information,which is not conducive to the subsequent reconstruction of the three-dimensional(3-D)structure of the magnetopause.The analysis of SXI-simulated observation images shows that such damage cannot be evaluated with traditional restoration models.This makes it difficult to establish the mapping relationship between SXIsimulated observation images and target images by using mathematical models.We propose an image restoration algorithm for SXIsimulated observation images that can recover large-scale structure information on the magnetosphere.The idea is to train a patch estimator by selecting noise–clean patch pairs with the same distribution through the Classification–Expectation Maximization algorithm to achieve the restoration estimation of the SXI-simulated observation image,whose mapping relationship with the target image is established by the patch estimator.The Classification–Expectation Maximization algorithm is used to select multiple patch clusters with the same distribution and then train different patch estimators so as to improve the accuracy of the estimator.Experimental results showed that our image restoration algorithm is superior to other classical image restoration algorithms in the SXI-simulated observation image restoration task,according to the peak signal-to-noise ratio and structural similarity.The restoration results of SXI-simulated observation images are used in the tangent fitting approach and the computed tomography approach toward magnetospheric reconstruction techniques,significantly improving the reconstruction results.Hence,the proposed technology may be feasible for processing SXI-simulated observation images. 展开更多
关键词 Solar wind Magnetosphere Ionosphere Link Explorer(SMILE) soft x-ray imager MAGNETOPAUSE image restoration
下载PDF
Simulation of the SMILE Soft X-ray Imager response to a southward interplanetary magnetic field turning 被引量:1
7
作者 Andrey Samsonov Graziella Branduardi-Raymont +3 位作者 Steven Sembay Andrew Read David Sibeck Lutz Rastaetter 《Earth and Planetary Physics》 EI CSCD 2024年第1期39-46,共8页
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne... The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning. 展开更多
关键词 MAGNETOPAUSE magnetic reconnection solar wind charge exchange southward interplanetary magnetic field numerical modeling Solar wind Magnetosphere Ionosphere Link Explorer(SMILE) Soft x-ray imager
下载PDF
Automated Algorithms for Detecting and Classifying X-Ray Images of Spine Fractures
8
作者 Fayez Alfayez 《Computers, Materials & Continua》 SCIE EI 2024年第4期1539-1560,共22页
This paper emphasizes a faster digital processing time while presenting an accurate method for identifying spinefractures in X-ray pictures. The study focuses on efficiency by utilizing many methods that include pictu... This paper emphasizes a faster digital processing time while presenting an accurate method for identifying spinefractures in X-ray pictures. The study focuses on efficiency by utilizing many methods that include picturesegmentation, feature reduction, and image classification. Two important elements are investigated to reducethe classification time: Using feature reduction software and leveraging the capabilities of sophisticated digitalprocessing hardware. The researchers use different algorithms for picture enhancement, including theWiener andKalman filters, and they look into two background correction techniques. The article presents a technique forextracting textural features and evaluates three picture segmentation algorithms and three fractured spine detectionalgorithms using transformdomain, PowerDensity Spectrum(PDS), andHigher-Order Statistics (HOS) for featureextraction.With an emphasis on reducing digital processing time, this all-encompassing method helps to create asimplified system for classifying fractured spine fractures. A feature reduction program code has been built toimprove the processing speed for picture classification. Overall, the proposed approach shows great potential forsignificantly reducing classification time in clinical settings where time is critical. In comparison to other transformdomains, the texture features’ discrete cosine transform (DCT) yielded an exceptional classification rate, and theprocess of extracting features from the transform domain took less time. More capable hardware can also result inquicker execution times for the feature extraction algorithms. 展开更多
关键词 Feature reduction image classification x-ray images
下载PDF
Pulmonary Edema and Pleural Effusion Detection Using Efficient Net-V1-B4 Architecture and AdamW Optimizer from Chest X-Rays Images
9
作者 Anas AbuKaraki Tawfi Alrawashdeh +4 位作者 Sumaya Abusaleh Malek Zakarya Alksasbeh Bilal Alqudah Khalid Alemerien Hamzah Alshamaseen 《Computers, Materials & Continua》 SCIE EI 2024年第7期1055-1073,共19页
This paper presents a novelmulticlass systemdesigned to detect pleural effusion and pulmonary edema on chest Xray images,addressing the critical need for early detection in healthcare.A new comprehensive dataset was f... This paper presents a novelmulticlass systemdesigned to detect pleural effusion and pulmonary edema on chest Xray images,addressing the critical need for early detection in healthcare.A new comprehensive dataset was formed by combining 28,309 samples from the ChestX-ray14,PadChest,and CheXpert databases,with 10,287,6022,and 12,000 samples representing Pleural Effusion,Pulmonary Edema,and Normal cases,respectively.Consequently,the preprocessing step involves applying the Contrast Limited Adaptive Histogram Equalization(CLAHE)method to boost the local contrast of the X-ray samples,then resizing the images to 380×380 dimensions,followed by using the data augmentation technique.The classification task employs a deep learning model based on the EfficientNet-V1-B4 architecture and is trained using the AdamW optimizer.The proposed multiclass system achieved an accuracy(ACC)of 98.3%,recall of 98.3%,precision of 98.7%,and F1-score of 98.7%.Moreover,the robustness of the model was revealed by the Receiver Operating Characteristic(ROC)analysis,which demonstrated an Area Under the Curve(AUC)of 1.00 for edema and normal cases and 0.99 for effusion.The experimental results demonstrate the superiority of the proposedmulti-class system,which has the potential to assist clinicians in timely and accurate diagnosis,leading to improved patient outcomes.Notably,ablation-CAM visualization at the last convolutional layer portrayed further enhanced diagnostic capabilities with heat maps on X-ray images,which will aid clinicians in interpreting and localizing abnormalities more effectively. 展开更多
关键词 image classification decision support system EfficientNet-V1-B4 AdamW optimizer pulmonary edema pleural effusion chest x-rays
下载PDF
High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal 被引量:2
10
作者 司昊轩 董佳钦 +3 位作者 方智恒 蒋励 伊圣振 王占山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期181-186,共6页
Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ... Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility. 展开更多
关键词 laser plasma diagnostics toroidal crystal monochromatic x-ray imaging
下载PDF
Centimeter-sized Cs_(3)Cu_(2)I_(5)single crystals grown by oleic acid assisted inverse temperature crystallization strategy and their films for high-quality X-ray imaging 被引量:1
11
作者 Tao Chen Xin Li +9 位作者 Yong Wang Feng Lin Ruliang Liu Wenhua Zhang Jie Yang Rongfei Wang Xiaoming Wen Bin Meng Xuhui Xu Chong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第4期382-389,共8页
Low-dimensional halide perovskites have become the most promising candidates for X-ray imaging,yet the issues of the poor chemical stability of hybrid halide perovskite,the high poisonousness of lead halides and the r... Low-dimensional halide perovskites have become the most promising candidates for X-ray imaging,yet the issues of the poor chemical stability of hybrid halide perovskite,the high poisonousness of lead halides and the relatively low detectivity of the lead-free halide perovskites which seriously restrain its commercialization.Here,we developed a solution inverse temperature crystal growth(ITCG)method to bring-up high quality Cs_(3)Cu_(2)I_(5)crystals with large size of centimeter order,in which the oleic acid(OA)is introduced as an antioxidative ligand to inhibit the oxidation of cuprous ions effieiently,as well as to decelerate the crystallization rate remarkalby.Based on these fine crystals,the vapor deposition technique is empolyed to prepare high quality Cs_(3)Cu_(2)I_(5)films for efficient X-ray imaging.Smooth surface morphology,high light yields and short decay time endow the Cs_(3)Cu_(2)I_(5)films with strong radioluminescence,high resolution(12 lp/mm),low detection limits(53 nGyair/s)and desirable stability.Subsequently,the Cs_(3)Cu_(2)I_(5)films have been applied to the practical radiography which exhibit superior X-ray imaging performance.Our work provides a paradigm to fabricate nonpoisonous and chemically stable inorganic halide perovskite for X-ray imaging. 展开更多
关键词 Inverse temperature crystal growth Cs_(3)Cu_(2)I_(5)single crystal Vapor deposition Cs_(3)Cu_(2)I_(5)films x-ray imaging
下载PDF
Analysis of refraction and scattering image artefacts in x-ray analyzer-based imaging
12
作者 赵立明 王天祥 +5 位作者 马润康 顾瑶 罗梦丝 陈恒 王志立 葛昕 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期535-540,共6页
X-ray analyzer-based imaging(ABI) is a powerful phase-sensitive technique that can provide a wide dynamic range of density and extract useful physical properties of the sample. It derives contrast from x-ray absorptio... X-ray analyzer-based imaging(ABI) is a powerful phase-sensitive technique that can provide a wide dynamic range of density and extract useful physical properties of the sample. It derives contrast from x-ray absorption, refraction, and scattering properties of the investigated sample. However, x-ray ABI setups can be susceptible to external vibrations, and mechanical imprecisions of system components, e.g., the precision of motor, which are unavoidable in practical experiments. Those factors will provoke deviations of analyzer angular positions and hence errors in the acquired image data.Consequently, those errors will introduce artefacts in the retrieved refraction and scattering images. These artefacts are disadvantageous for further image interpretation and tomographic reconstruction. For this purpose, this work aims to analyze image artefacts resulting from deviations of analyzer angular positions. Analytical expressions of the refraction and scattering image artefacts are derived theoretically and validated by synchrotron radiation experiments. The results show that for the refraction image, the artefact is independent of the sample’s absorption and scattering signals. By contrast, artefact of the scattering image is dependent on both the sample’s refraction and scattering signals, but not on absorption signal.Furthermore, the effect of deviations of analyzer angular positions on the accuracy of the retrieved images is investigated,which can be of use for optimization of data acquisition. This work offers the possibility to develop advanced multi-contrast image retrieval algorithms that suppress artefacts in the retrieved refraction and scattering images in x-ray analyzer-based imaging. 展开更多
关键词 x-ray imaging analyzer-based imaging image artefacts
下载PDF
Investigations of moiréartifacts induced by flux fluctuations in x-ray dark-field imaging
13
作者 王志立 陈子涵 +2 位作者 顾瑶 陈恒 葛昕 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期621-628,共8页
X-ray dark-field imaging using a grating interferometer has shown potential benefits for a variety of applications in recent years.X-ray dark-field image is commonly retrieved by using discrete Fourier transform from ... X-ray dark-field imaging using a grating interferometer has shown potential benefits for a variety of applications in recent years.X-ray dark-field image is commonly retrieved by using discrete Fourier transform from the acquired phasestepping data.The retrieval process assumes a constant phase step size and a constant flux for each stepped grating position.However,stepping errors and flux fluctuations inevitably occur due to external vibrations and/or thermal drift during data acquisition.Previous studies have shown that those influences introduce errors in the acquired phase-stepping data,which cause obvious moiréartifacts in the retrieved refraction image.This work investigates moiréartifacts in x-ray dark-field imaging as a result of flux fluctuations.For the retrieved mean intensity,amplitude,visibility and dark-field images,the dependence of moiréartifacts on flux fluctuation factors is theoretically derived respectively by using a first-order Taylor series expansion.Results of synchrotron radiation experiments verify the validity of the derived analytical formulas.The spatial frequency characteristics of moiréartifacts are analyzed and compared to those induced by phase-stepping errors.It illustrates that moiréartifacts can be estimated by a weighted mean of flux fluctuation factors,with the weighting factors dependent on the moiréphase and different greatly for each retrieved image.Furthermore,moiréartifacts can even be affected by object’s features not displayed in the particular contrast.These results can be used to interpret images correctly,identify sources of moiréartifacts,and develop dedicated algorithms to remove moiréartifacts in the retrieved multi-contrast images. 展开更多
关键词 x-ray imaging dark-field imaging moiréartifacts flux fluctuations
下载PDF
A cadaveric breast cancer tissue phantom for phase-contrast X-ray imaging applications
14
作者 Cody C.Rounds Chengyue Li +2 位作者 Wei Zhou Kenneth M.Tichauer Jovan G.Brankov 《Animal Models and Experimental Medicine》 CAS CSCD 2023年第5期427-432,共6页
Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advan... Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advanced imaging modalities such as refraction-based methods,it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production.This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods:Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results:The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging.Digital breast tomosynthesis was also performed.Conclusion:Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities. 展开更多
关键词 breast tumors digital mammography imaging phantoms orthotopic animal models phasecontrast x-ray imaging
下载PDF
Ultrafast two-dimensional x-ray imager with temporal fiducial pulses for laser-produced plasmas
15
作者 刘正东 仲佳勇 +21 位作者 远晓辉 张雅芃 姚嘉文 马作霖 徐向晏 薛彦华 张喆 袁大伟 张敏睿 李炳均 谷昊琛 戴羽 张成龙 董玉峰 周鹏 马鑫杰 马云峰 白雪洁 刘高扬 田进寿 赵刚 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期214-219,共6页
It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray s... It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments. 展开更多
关键词 ultrafast diagnosis double-cone ignition x-ray streak camera pinhole array temporal fiducial pulses
下载PDF
The new X-ray imaging and biomedical application beamline BL13HB at SSRF
16
作者 Jian‑Feng Ji Han Guo +6 位作者 Yan‑Ling Xue Rong‑Chang Chen Ya‑Nan Fu Guo‑Hao Du Biao Deng Hong‑Lan Xie Ti‑Qiao Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期190-205,共16页
A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1... A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021. 展开更多
关键词 x-ray imaging Dynamic micro-CT Shanghai Synchrotron Radiation Facility
下载PDF
ARRAY PULSED EDDY CURRENT IMAGING SYSTEM USED TO DETECT CORROSION 被引量:4
17
作者 YangBinfeng LuoFeilu CaoXiongheng XuXiaojie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第2期196-198,共3页
A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC... A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The testresults show that this system has the advantage of fast scanning speed, different imaging mode andquantitative detection, it has a broad application in the aviation nondestructive testing. 展开更多
关键词 Array probe pulsed eddy current Aircraft structure Corrosion imaging
下载PDF
Clinical evaluation of thyroid cancer in sound pulsed radiographic imaging and correlation analysis of OPN and OPN mRNA expression 被引量:1
18
作者 Lan Feng Xiang-Xiang Jing +4 位作者 Yang Tao Xiu-Hong Xing Ru-Liang Yuan Li-Ni Fang Fu-Xiong Zheng 《Journal of Hainan Medical University》 2018年第9期83-86,共4页
Objective:To investigate the clinical assessment of thyroid carcinoma in acoustic pulse radiation imaging and the correlation analysis of osteopontin expression.Methods: A total of 71 lesions of 60 patients with thyro... Objective:To investigate the clinical assessment of thyroid carcinoma in acoustic pulse radiation imaging and the correlation analysis of osteopontin expression.Methods: A total of 71 lesions of 60 patients with thyroid carcinoma (TC) in Hainan were selected. All patients were graded by TI-RADS grading and confirmed by pathology after operation. The expression of OPN was detected by immunohistochemical S-P method. The expression of OPN mRNA was detected by fluorescence quantitative polymerase chain reaction. The correlation between OPN expression and acoustic pulse radiation imaging was analyzed.Results:(1) 60 patients (93.33%) with primary TC and 4 (6.67%) patients with secondary TC were found in 60 patients with TC. Thirty-seven patients (61.67% according to the pathological features, 32 cases (53.33%) had papillary TC, diffuse sclerosis 19 cases of diffuse sclerosis PTC (31.67%), follicular carcinoma in 9 cases (15.00%). (2) The expression of OPN mRNA in 37 cases of calcified TC was significantly higher than that in non-calcified TC, and the increase of OPN expression was in direct proportion to the distribution of gritty calcification.Conclusions: The distribution of calcified microsomes in TC was positively correlated with the expression of OPN, suggesting that enhanced OPN expression may be related to the formation of psammoma bodies, the increased hardness of nodules and the increased malignancy. Acoustic pulse radiation imaging technology for early diagnosis of TC and prognosis of TC was of great significance. 展开更多
关键词 THYROID carcinoma Acoustic pulse radiation imaging OSTEOPONTIN
下载PDF
Methodology development and application of X-ray imaging beamline at SSRF 被引量:8
19
作者 Hong-Lan Xie Biao Deng +7 位作者 Guo-Hao Du Ya-Nan Fu Han Guo Yan-Ling Xue Guan-Yun Peng Fen Tao Ling Zhang Ti-Qiao Xiao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期74-94,共21页
This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the... This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided. 展开更多
关键词 x-ray imaging x-ray in-line phase-contrast imaging x-ray micro-CT Dynamic micro-CT x-ray speckle-tracking imaging 3DXRD SAXS-CT x-ray fluorescence CT x-ray nano-CT Move contrast x-ray imaging
下载PDF
Magnetic resonance imaging with three-dimensional fast imaging employing steady-state acquisition with phase-cycled and short T1 inversion recovery pulse sequence for evaluating brachial plexus injury 被引量:7
20
作者 Dianxiu Ning Meiyu Sun +11 位作者 Bo Sun Li Zhao Weisheng Zhang Lijun Wang Shaowu Wang Ailian Liu Jianlin Wu Zhijin Lang Di Ning Guanfu Liu Xiaochen Ji Xiufeng Wang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第14期1097-1102,共6页
There is a large amount of fat in the postganglionic segment of the brachial plexus nerve.The use of short T1 inversion recovery pulse sequence may improve signal strength of the brachial plexus postganglionic segment... There is a large amount of fat in the postganglionic segment of the brachial plexus nerve.The use of short T1 inversion recovery pulse sequence may improve signal strength of the brachial plexus postganglionic segment.The present study revealed that the combination of three-dimensional fast imaging employing steady-state acquisition with phase-cycled and short T1 inversion recovery pulse sequence clearly displayed the anatomical morphology and structure of the brachial plexus nerve,together with maximum intensity projection,volume rendering and other three-dimensional reconstruction techniques.Our results suggested that this method is also suitable for providing accurate assessment and diagnosis of the site,severity and scope of brachial plexus injury. 展开更多
关键词 brachial plexus i-njury magnetic resonance imaging pulse sequence reconstruction
下载PDF
上一页 1 2 79 下一页 到第
使用帮助 返回顶部