期刊文献+
共找到1,153篇文章
< 1 2 58 >
每页显示 20 50 100
A study of pulsed high voltage driven hollow-cathode electron beam sources through synchronous optical trigger
1
作者 霍卫杰 贺伟国 +2 位作者 韩罗峰 朱康武 王锋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期82-90,共9页
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t... In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam. 展开更多
关键词 hollow-cathode nanosecond pulsed electron beam sources optical trigger pulsed high voltage supply beam current distribution
下载PDF
Atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction
2
作者 Ding-Han Zhu Xiong Zhang +3 位作者 Xiao-Qiang Li Peng Li Yan-Bin Wang Shuang Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期40-52,共13页
In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detect... In high-altitude nuclear detonations,the proportion of pulsed X-ray energy can exceed 70%,making it a specific monitoring signal for such events.These pulsed X-rays can be captured using a satellite-borne X-ray detector following atmospheric transmission.To quantitatively analyze the effects of different satellite detection altitudes,burst heights,and transmission angles on the physical processes of X-ray transport and energy fluence,we developed an atmospheric transmission algorithm for pulsed X-rays from high-altitude nuclear detonations based on scattering correction.The proposed method is an improvement over the traditional analytical method that only computes direct-transmission X-rays.The traditional analytical method exhibits a maximum relative error of 67.79% compared with the Monte Carlo method.Our improved method reduces this error to within 10% under the same conditions,even reaching 1% in certain scenarios.Moreover,its computation time is 48,000 times faster than that of the Monte Carlo method.These results have important theoretical significance and engineering application value for designing satellite-borne nuclear detonation pulsed X-ray detectors,inverting nuclear detonation source terms,and assessing ionospheric effects. 展开更多
关键词 High-altitude nuclear detonation Atmospheric transmission pulsed x-rays Scattering correction Analytical method Monte Carlo method
下载PDF
Two Monte Carlo-based simulators for imaging-system modeling and projection simulation of flat-panel X-ray source
3
作者 Meng-Ke Qi Ting He +7 位作者 Yi-Wen Zhou Jing Kang Zeng-Xiang Pan Song Kang Wang-Jiang Wu Jun Chen Ling-Hong Zhou Yuan Xu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期31-46,共16页
The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and res... The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and resolving overlapping projection issues in FPXS.The conventional analytical ray-tracing approach is limited by the number of patterns and is not applicable to FPXS-projection calculations.However,the computation time of Monte Carlo(MC)simulation is independent of the size of the patterned arrays in FPXS.This study proposes two high-efficiency MC projection simulators for FPXS:a graphics processing unit(GPU)-based phase-space sampling MC(gPSMC)simulator and GPU-based fluence sampling MC(gFSMC)simulator.The two simulators comprise three components:imaging-system modeling,photon initialization,and physical-interaction simulations in the phantom.Imaging-system modeling was performed by modeling the FPXS,imaging geometry,and detector.The gPSMC simulator samples the initial photons from the phase space,whereas the gFSMC simulator performs photon initialization from the calculated energy spectrum and fluence map.The entire process of photon interaction with the geometry and arrival at the detector was simulated in parallel using multiple GPU kernels,and projections based on the two simulators were calculated.The accuracies of the two simulators were evaluated by comparing them with the conventional analytical ray-tracing approach and acquired projections,and the efficiencies were evaluated by comparing the computation time.The results of simulated and realistic experiments illustrate the accuracy and efficiency of the proposed gPSMC and gFSMC simulators in the projection calculation of various phantoms. 展开更多
关键词 Flat-panel x-ray source(FPXS) Imaging-system modeling Projection simulation Monte Carlo-based simulators
下载PDF
Factors Influencing the Electron Yield of Needle-Ring Pulsed Corona Discharge Electron Source for Negative Ion Mobility Spectrometer 被引量:4
4
作者 刘欣 李胜利 李铭书 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1215-1220,共6页
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron... A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source. 展开更多
关键词 ion mobility spectrometer electron source pulsed corona discharge effectiveelectrons simulation
下载PDF
Optimization of 4.7-keV X-ray titanium sources driven by 100-ps laser pulses 被引量:1
5
作者 熊俊 董佳钦 +4 位作者 贾果 王瑞荣 王伟 傅思祖 郑无敌 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第6期454-458,共5页
An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ... An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ≈120 J, τL ≈100 ps) is injected into the underdense plasma and produces strong line emission from the titanium K shell (i.e., Hea at 4.7 keV). Data show that the intensity of 4.7-keV X-ray emission with the prepulse is approximately twice more than without the prepulse, and can be used as a backlighting source satisfying the diagnostic requirements for dense plasma probing. High- quality plasma images are obtained with the backlighfing 4.7-keV X-rays in a Rayleigh-Taylor hydrodynamic instability experiment. 展开更多
关键词 x-ray source PREpulsE titanium foil
下载PDF
Characteristics of Resistance Triggering of a Pulsed Vacuum Arc Ion Source 被引量:1
6
作者 蓝朝晖 龙继东 +4 位作者 郑乐 董攀 杨振 王韬 李杰 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期84-87,共4页
Triggering scheme is a significant factor that may influence the process of vacuum arc initiation. In this work, the characteristics of resistance triggering of a pulsed vacuum arc ion source are investigated and comp... Triggering scheme is a significant factor that may influence the process of vacuum arc initiation. In this work, the characteristics of resistance triggering of a pulsed vacuum arc ion source are investigated and compared with the independent pulse generator triggering. The results show that although the resistance triggering method is capable of triggering a vacuum arc ion source by properly choosing the resistance and electric parameters, it inevitably increases the rise time of the arc current. A high speed multiframe camera is used to reveal the transition process o~ arc initiation during one shot. From the images it is conjectured that the lower voltage between the cathode and the anode may be the reason that leads to the lower transition speed of discharge at the moment of arc initiation. 展开更多
关键词 In Characteristics of Resistance Triggering of a pulsed Vacuum Arc Ion source ARC
下载PDF
Study on welding power source used in intelligent control system for weld pool shape in pulsed GTAW
7
作者 张广军 陈善本 +1 位作者 吴林 耿正 《China Welding》 EI CAS 2001年第2期33-37,共5页
This paper analyses the performance request of arc welding power source used in intelligent control of weld pool shape in pulsed GTAW, and develops a sample power source. The main circuit of the power source takes the... This paper analyses the performance request of arc welding power source used in intelligent control of weld pool shape in pulsed GTAW, and develops a sample power source. The main circuit of the power source takes the structure of single ended inverter with two switches, and takes IGBTs as power switches. The working frequency of the inverter is set at 20 kHz. The control circuit takes PWM circuit as center, and uses single chip computer to complete the manage functions such as the control of working sequence, setting and changing of the welding parameters, sensing of the welding states and communication with outside computer etc. The dynamic reacting time of the whole power is 1 ms, the range of the output current is 5~250 A, the precision of the output current reaches to 1 A. The power strikes arc by contacting workpiece under 5 A, and have convenient interface with system computer. All above shows this power source is one with high performance. 展开更多
关键词 arc welding power source pulsed GTAW weld pool shape intelligent control
下载PDF
Ultraviolet Source Assisted Enhancement of Attosecond Pulse 被引量:3
8
作者 冯立强 刘航 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2015年第1期21-26,I0001,共7页
A promising method to improve the attosecond pulse intensity has been theoretically pre- sented by properly adding an ultraviolet pulse into the orthogonal two-color field. The results show that by properly adding a 1... A promising method to improve the attosecond pulse intensity has been theoretically pre- sented by properly adding an ultraviolet pulse into the orthogonal two-color field. The results show that by properly adding a 125 nm ultraviolet pulse to the orthogonal two-color field, not only the harmonic yield is enhanced by 2 orders of magnitude compared with the original orthogonal two-color field case, but also the single short quantum path, which is selected to contribute to the harmonic spectrum, results in an ultrabroad 152 eV bandwidth. Moreover, by optimizing the laser parameters, we find that the harmonic enhancement is not very sen- sitive to the pulse duration and the polarized angle of the assisted ultraviolet pulse, which is much better for experimental realization. As a result, an isolated pulse with duration of 38 as can be obtained, which is 2 orders of magnitude improvement in comparison with the original two-color orthogonal field case. 展开更多
关键词 High-order harmonic generation Isolated pulse Two-color orthogonal field Ultraviolet source
下载PDF
Beam and image experiment of beam deflection electron gun for distributed X-ray sources 被引量:7
9
作者 Cheng-Jun Tan Chuan-Xiang Tang +7 位作者 Wen-Hui Huang Qing-Xiu Jin Ying-Chao Du Qun Luo Pei-Dong Wu Dong-Hai Liu Lu-Ming Zhang Cong Xu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期127-138,共12页
Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative s... Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk. 展开更多
关键词 BEAM DEFLECTION electron GUN x-ray imaging DISTRIBUTED x-ray sources STATIONARY CT
下载PDF
Effect of source parameters on forward-directivity velocity pulse for vertical strike slip fault in half space 被引量:3
10
作者 刘启方 袁一凡 金星 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第1期1-9,共9页
It has been found that the large velocity pulse is one of the most important characteristics of near-fault strong ground motions. Some statistical relationships between pulse period and the moment magnitude for near-f... It has been found that the large velocity pulse is one of the most important characteristics of near-fault strong ground motions. Some statistical relationships between pulse period and the moment magnitude for near-fault strong ground motions have been established by Somerville (1998); Alavi and Krawinkler (2000); and Mavroeidis and Papageorgiou (2003), where no variety of rupture velocity, fault depth, and fault distance, etc. were considered. Since near-fault ground motions are significantly influenced by the rupture process and source parameters, the effects of some source parameters on the amplitude and the period ofa forward-directivity velocity pulse in a half space are analyzed by the finite difference method combined with the kinematic source model in this paper. The study shows that the rupture velocity, fault depth, position of the initial rupture point and distribution of asperities are the most important parameters to the velocity pulse. Generally, the pulse period decreases and the pulse amplitude increases as the rupture velocity increases for shallow crustal earthquakes. In a definite region besides the fault trace, the pulse period increases as the fault depth increases. For a uniform strike slip fault, rupture initiating from one end of a fault and propagating to the other always generates a higher pulse amplitude and longer pulse period than in other cases. 展开更多
关键词 forward-directivity velocity pulse AMPLITUDE pulse period source parameters rupture velocity fault depth ASPERITY
下载PDF
Dielectric barrier discharge plasma-assisted catalytic ammonia synthesis:synergistic effect of Ni-MOF-74 catalyst and nanosecond pulsed plasma
11
作者 徐晓芳 孙萌 +4 位作者 宋勤龙 吴璇 陈冲冲 陈强 张海宝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期40-49,共10页
Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading t... Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading to significant energy consumption and environmental pollution.Non-thermal plasma(NTP) is a promising alternative approach to ammonia synthesis at low temperature and atmospheric pressure.In this study,the synergistic effect of nanosecond pulsed dielectric barrier discharge(np-DBD) and Ni-MOF-74 catalyst was investigated in ammonia synthesis by utilizing nitrogen and hydrogen as feedstock.The results demonstrated that the plasma catalytic-synthesis process parameters play a crucial role in the synthesis process of ammonia.The highest ammonia synthesis rate of 5145.16 μmol·g^(-1)·h^(-1)with an energy efficiency of 1.27 g·kWh^(-1)was observed in the presence of the Ni-MOF-74 catalyst,which was3.7 times higher than that without Ni-MOF-74 catalyst.The synergistic effect of Ni-MOF-74catalyst and nanosecond pulsed plasma was explored by in-situ plasma discharge diagnostics. 展开更多
关键词 AMMONIA SYNTHESIS low-temperature plasma nanosecond pulsed power source Ni-MOF-74
下载PDF
Experimental Study of the X-Ray Radiation Source at Approximately Constant Radiation Temperature 被引量:1
12
作者 宋天明 杨家敏 +2 位作者 杨冬 李志超 尚万里 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1108-1111,共4页
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the... An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
Development of high frequency pulse power source using two powersfor TIG welding 被引量:1
13
作者 张广军 耿正 +1 位作者 吴林 梁群 《China Welding》 EI CAS 1999年第2期38-42,共5页
A high frequency pulse power source for TIG welding is developed. The structure of two powers is adopted. The by pass circuit effectively eliminates the effect of the cable equivalent inductance. The maximum frequenc... A high frequency pulse power source for TIG welding is developed. The structure of two powers is adopted. The by pass circuit effectively eliminates the effect of the cable equivalent inductance. The maximum frequency of the output pulse current reaches to 16 kHz . The base current and the peak current can be regulated separately. 展开更多
关键词 high frequency pulse TIG welding arc welding power source
下载PDF
Linear Track Estimation Using Double Pulse Sources for Near-Field Underwater Moving Target 被引量:2
14
作者 Zhifei ChenI Hong Hou +2 位作者 Jianhua Yang Jincai Sun Qian Wang 《Journal of Marine Science and Application》 2013年第2期240-244,共5页
The double pulse sources (DPS) method is presented for linear track estimation in this work. In the field of noise identification of underwater moving target, the Doppler will distort the frequency and amplitude of ... The double pulse sources (DPS) method is presented for linear track estimation in this work. In the field of noise identification of underwater moving target, the Doppler will distort the frequency and amplitude of the radiated noise. To eliminate this, the track estimation is necessary. In the DPS method, we first estimate bearings of two sinusoidal pulse sources installed in the moving target through baseline positioning method. Meanwhile, the emitted and recorded time of each pulse are also acquired. Then the linear track parameters will be achieved based on the geometry pattern with the help of double sources spacing. The simulated results confirm that the DPS improves the performance of the previous double source spacing method. The simulated experiments were carried out using a moving battery car to further evaluate its performance. When the target is 40-60m away, the experiment results show that biases of track azimuth and abeam distance of DPS are under 0.6° and 3.4m, respectively. And the average deviation of estimated velocity is around 0.25m/s. 展开更多
关键词 linear track estimation double pulse sources (DPS) baseline positioning method time-of-arrival difference
下载PDF
Laser-produced plasma helium-like titanium Kα x-ray source and its application to Rayleigh-Taylor instability study 被引量:1
15
作者 王瑞荣 陈伟民 +2 位作者 王伟 董佳钦 肖沙里 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期362-368,共7页
Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of genera... Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of generating these high intensity sources. By using a time-integrated space-resolved keV spectroscope and pinhole camera, potential helium-like titanium Kα x-ray backlighting (radiography) line source is studied as a function of laser wavelength, ratio of pre-pulse intensity to main pulse intensity, and laser intensity (from 7.25 to ~ 11.3 × 10^15 W/cm2). One-dimensional radiography using a grid consisting of 5 #m Au wires on 16 μm period and the pinhole-assisted point projection is tested. The measurements show that the size of the helium-like titanium Ka source from a simple foil target is larger than 100 ~m, and relative x-ray line emission conversion efficiency ~x from the incident laser light energy to helium- like titanium K-shell spectrum increases significantly with pre-pulse intensity increasing, increases rapidly with laser wavelength decreasing, and increases moderately with main laser intensity increasing. It is also found that a gold gird foils can reach an imaging resolution better than 5-μm featured with high contrast. It is further demonstrated that the pinhole-assisted point projection at such a level will be a novel two-dimensional imaging diagnostic technique for inertial confinement fusion experiments. 展开更多
关键词 x-ray source plasma diagnostic techniques x-ray spectra
下载PDF
Development of a seven-cell S-band standing-wave RF-deflecting cavity for Tsinghua Thomson scattering X-ray source 被引量:1
16
作者 Xian-Cai Lin Hao Zha +4 位作者 Jia-Ru Shi Liu-Yuan Zhou Shuang Liu Jian Gao Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期20-29,共10页
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p... A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented. 展开更多
关键词 Deflecting RF cavity Standing wave Bunchlength measurement Thomson x-ray source
下载PDF
Estimation of Ion Beam Trajectories for a Slot Aperture Accelerator of Long-Pulse Ion Source in Neutral Beam Injector 被引量:1
17
作者 Doo-Hee Chang 《Open Journal of Applied Sciences》 2013年第2期163-168,共6页
A neutral beam injection (NBI) system has been developed and is being tested for an Experimental Advanced Superconducting Tokamak (EAST) device. The NBI system needs to be employed for an auxiliary heating and current... A neutral beam injection (NBI) system has been developed and is being tested for an Experimental Advanced Superconducting Tokamak (EAST) device. The NBI system needs to be employed for an auxiliary heating and current drive of EAST plasmas. The first long pulse ion source (LPIS-1) has been installed in the neutral beam test bed (NBTB) system, and the performance is being tested in the NBTB. The LPIS-1 consists of a magnetic bucket plasma generator with multipole cusp-fields and a set of tetrode accelerators with slit-type apertures (a transparency of 60%). The ion beam trajectories of the accelerator column are estimated for the LPIS-1, including an original structure, with the change of slit aperture distance, plasma grid shape, grid gap distance, and voltage ratio between a plasma grid and a gradient grid using the IGUN code. This kind of calculation for the ion beam trajectory may be useful for the estimation of beam extraction characteristics and the direction of accelerator upgrade or modification, prior to the experiments of ion beam extraction. 展开更多
关键词 Long pulse ION source SLOT APERTURE ACCELERATOR EAST Neutral BEAM Injection ION BEAM Trajectory IGUN Code
下载PDF
Light-controlled pulsed x-ray tube with photocathode
18
作者 Hao Xuan Yong-An Liu +4 位作者 Peng-Fei Qiang Tong Su Xiang-Hui Yang Li-Zhi Sheng Bao-Sheng Zhao 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第11期650-655,共6页
Unstable mechanical structure,low energy efficiency,and cooling requirements limit the application of conventional x-ray tubes based on filament as cathode in several academic areas.In this paper,we demonstrate a ligh... Unstable mechanical structure,low energy efficiency,and cooling requirements limit the application of conventional x-ray tubes based on filament as cathode in several academic areas.In this paper,we demonstrate a light-controlled pulsed x-ray tube using multialkali cathode as electron generator.The photocathode active area of the light controlled x-ray tube is 13.2 cm^(2)(41 mm in diameter),which provides high photoelectron-emitting efficiency up to 0.288 mA/lm in 460-nm LED and 2.37-mA maximum tube current.Furthermore,the modulation ability from 1 kHz to 100 kHz of the x-ray tube is tested.The results suggest that the light-controlled pulsed x-ray tube has easy modulation and short x-ray pulse properties and is promising to be the next generation x-ray tube with wide applications in medical radiation therapy as well as the calibration for detectors and scintillators. 展开更多
关键词 x-ray source PHOTOCATHODE x-ray modulation
下载PDF
Numerical simulation for all-optical Thomson scattering X-ray source
19
作者 谭放 朱斌 +5 位作者 韩丹 辛建婷 赵宗清 曹磊峰 谷渝秋 张保汉 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期249-255,共7页
Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-... Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction. 展开更多
关键词 ultrashort laser wakefield acceleration Thomson scattering x-ray source
下载PDF
Biomedical X-ray Imaging Enabled by Carbon Nanotube X-ray Sources
20
作者 Guohua Cao 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2018年第4期529-536,615,共9页
Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the fiel... Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple. 展开更多
关键词 Biomedical imaging x-ray imaging x-ray source Carbon nanotube x-raysource Carbon nanotube Field emission Cornputed tornography Breast tornosynthesis
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部