For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model wi...In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.展开更多
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho...To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.展开更多
The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of buildin...The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of variable flow operation is superior to that of constant flow.It is also concluded that the climate region and function of the buildings are primary factors which affect the suitability of variable flow operation in GWSHP.展开更多
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo...Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is...The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.展开更多
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati...This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP.展开更多
Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditio...Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.展开更多
The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the Eur...The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system.展开更多
According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP...According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas.展开更多
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d...Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.展开更多
Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with ti...Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%.展开更多
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of...A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.展开更多
Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-fe...Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy.展开更多
The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D bor...The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D borehole and total internal thermal resistance(R_(b,3D)and R_(a,3D))and analyze the impacts of parameters on the R_(b,3D)and R_(a,3D).Firstly,eight parameters affecting the R_(b,3D)and R_(a,3D),including the borehole diameter,pipe diameter,pipe-pipe distance,borehole depth,soil thermal conductivity,grout thermal conductivity,pipe thermal conductivity,and fluid velocity inside the pipe,were considered and an L-54 design matrix was generated.Then,the 3D numerical model,coupling with the four-resistance model,was proposed to calculate R_(b,3D)and R_(a,3D)for each case.After that,the response surface methodology was employed to obtain and verify the correlation of R_(b,3D)and R_(a,3D),which were compared with the existing resistance calculation methods.Lastly,analysis of variance was carried out to reveal parameters that have statistically significant impacts on the R_(b,3D)and R_(a,3D).Results show that the rationality and accuracy of the correlation of R_(b,3D)and R_(a,3D)can be verified by the determination coefficient and P value of regression model,as well as the P value of lack-of-fit.The existing resistance calculation methods are more or less inaccurate and the discrepancies in some cases can be up to 86.74%and 111.35%for the borehole and total internal thermal resistance.The pipe and grout thermal conductivity,pipe and borehole diameter,and the pipe-pipe distance can be seen as the significant contributory factors to the variation of R_(b,3D)and R_(a,3D).展开更多
A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre...A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.展开更多
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t...The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.展开更多
Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume numerical model was established under the assumption that the...Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume numerical model was established under the assumption that the soil thermal conductivity had been known in the simulation of thermal response test.The thermal response curve was firstly obtained through numerical calculation.Then,the accuracy of the numerical model was verified with measured data obtained through a thermal response test.Based on the numerical and experimental thermal response curves,the thermal conductivity of the soil was calculated by different parameter identification methods.The calculated results were compared with the assumed value and then the accuracy of these methods was evaluated.Furthermore,the effects of test time,variable data quality,borehole radius,initial ground temperature,and heat injection rate were analyzed.The results show that the method based on cylinder-source model has a low precision and the identified thermal conductivity decreases with an increase in borehole radius.For parameter estimation,the measuring accuracy of the initial temperature of the deep ground soil has greater effect on identified thermal conductivity.展开更多
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B04)China Postdoctoral Science Foundation(No.20090461050)+1 种基金the Project of Researchand Development of Ministry of Housing and Urban-Rural Development ofChina(No.2008-K1-26)the New Century Talent Project of Yangzhou University for Excellent Young Backbone Teacher(2008)
文摘In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.
基金Project(50606007) supported by the National Natural Science Foundation of China
文摘To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.
基金Project(2006BAJ01B05) supported by the National Science and Technology Pillar Program during the 11th Five-Year Plane Period
文摘The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of variable flow operation is superior to that of constant flow.It is also concluded that the climate region and function of the buildings are primary factors which affect the suitability of variable flow operation in GWSHP.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2010DFA72740-05) supported by the International Science & Technology Cooperation Program of China
文摘Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
基金Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,ChinaProject(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
文摘The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
基金supported by the Estonian Research Council,with Institutional research funding grant IUT1-15with the project“Development of efficient tech-nologies for air change and ventilation necessary for the increase of energy efficiency of buildings,AR12045”,financed by SA Archimedesby the project“Civil and Environmental Engineering PhD School,DAR9085”.
文摘This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP.
基金the Science and Technology Program Project of the Ministry of Housing and Urban-Rural Development“Research on Indoor Thermal Environment Based on Zero Energy Building Technology in Hot Summer and Cold Winter Area”(2017-K1-014)Hubei Provincial Natural Fund Youth Fund“Technology and Evaluation of Multi-energy Complementary Energy Supply for Rural Residential Buildings in Hubei”(2017CFB311).
文摘Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.
文摘The objective of the present paper is to describe a technical and economical visibility study of the application of ground source heat pumps (GSHP) in a supermarket in Portugal. The study was developed under the European project "Integration of Geothermal Energy Into Industrial Application - IGEIA", project number EIE 06/001, supported by the Intelligent Energy for Europe, IEE, of EACI, European Commission. In general for supermarkets installed in single buildings, the building envelope has higher rates of envelope areas per indoor air volume. In Portugal this fact produces high need of heating during the winter season and high cooling needs during the summer season. Inside the building there are strong internal heat loads produced by high densities of lights and equipments. However these internal loads are not distributed uniformly. There are some areas with high production of heat but there are others with production of cooling. Therefore the acclimatization of this kind of buildings is not so easy and the balance of heating and cooling needs is depending of different parameters which should be well evaluated. The energy consummation of the cold display cases and deep freezers in market area and storage is also very high. The different energy needs could be studied in an integrated way and could be partially satisfied by geothermal energy using ground source heat pumps. At the same time the boreholes could be used as an energy reservoir increasing the efficiency of whole system. Four different climatic zones in Portugal were selected, (north coast, interior north, south coast and interior south) using the same system. The results of the study show that the all energy needs can by partially satisfied by geothermal energy but they need to be integrated to increase the global efficiency. The paper shows that the geothermal energy can be an attractive application for the supermarkets in Portugal if the energy solution is studied in an integrated way and if it is also considered as a cost the emissions of CO2 avoid by the new system.
基金Supported by project of Shallow Geothermal Energy Survey of Inner Mongolia Baotou Plain(No.2010-3-SK35)
文摘According to the elements of hydrogeological conditions,lithology,stratigraphic thermal physical parameters,construction technology and economic rational elements,the evaluation system of ground source heat pump( GSHP) were established in Baotou plain. The factor weights were determined by using analytic hierarchy process,and the comprehensive element method was selected to evaluate the region suitability of GSHP system. The results show that the suitable area is 559. 63 km2 for utilizing GSHP in the studied area,accounting for 62. 58% of the total area; while the unsuitable area is 334. 60 km2,accounting for37.42%. The evaluating results can provide not only a scientific basis for development and utilization rationally of shallow geothermal heat in Baotou,but also offer an important reference to the other areas.
文摘Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.
文摘Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%.
基金the National Natural Science Foundation of China(No.51776117)。
文摘A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.
基金The authors gratefully acknowledge the funding support from Sun Yat-Sen University(76140-18841230 and 2021qntd15)Guangdong Basic and Applied Basic Research Foundation(2021A1515011739,2020A1515110391 and 2020B1515120083).
文摘Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy.
基金This work was supported by the National Natural Science Foundation of China(No.51708551).
文摘The borehole and total internal thermal resistance are both significant parameters in evaluating the thermal performance of the ground source heat pump.This study aimed to obtain the accurate correlation of the 3D borehole and total internal thermal resistance(R_(b,3D)and R_(a,3D))and analyze the impacts of parameters on the R_(b,3D)and R_(a,3D).Firstly,eight parameters affecting the R_(b,3D)and R_(a,3D),including the borehole diameter,pipe diameter,pipe-pipe distance,borehole depth,soil thermal conductivity,grout thermal conductivity,pipe thermal conductivity,and fluid velocity inside the pipe,were considered and an L-54 design matrix was generated.Then,the 3D numerical model,coupling with the four-resistance model,was proposed to calculate R_(b,3D)and R_(a,3D)for each case.After that,the response surface methodology was employed to obtain and verify the correlation of R_(b,3D)and R_(a,3D),which were compared with the existing resistance calculation methods.Lastly,analysis of variance was carried out to reveal parameters that have statistically significant impacts on the R_(b,3D)and R_(a,3D).Results show that the rationality and accuracy of the correlation of R_(b,3D)and R_(a,3D)can be verified by the determination coefficient and P value of regression model,as well as the P value of lack-of-fit.The existing resistance calculation methods are more or less inaccurate and the discrepancies in some cases can be up to 86.74%and 111.35%for the borehole and total internal thermal resistance.The pipe and grout thermal conductivity,pipe and borehole diameter,and the pipe-pipe distance can be seen as the significant contributory factors to the variation of R_(b,3D)and R_(a,3D).
基金supported by the National Natural Science Foundation of China (Grant No. 51076147)
文摘A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.
文摘The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%.
基金Project(xjj20100078) supported by the Fundamental Research Funds for the Central Universities in China
文摘Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume numerical model was established under the assumption that the soil thermal conductivity had been known in the simulation of thermal response test.The thermal response curve was firstly obtained through numerical calculation.Then,the accuracy of the numerical model was verified with measured data obtained through a thermal response test.Based on the numerical and experimental thermal response curves,the thermal conductivity of the soil was calculated by different parameter identification methods.The calculated results were compared with the assumed value and then the accuracy of these methods was evaluated.Furthermore,the effects of test time,variable data quality,borehole radius,initial ground temperature,and heat injection rate were analyzed.The results show that the method based on cylinder-source model has a low precision and the identified thermal conductivity decreases with an increase in borehole radius.For parameter estimation,the measuring accuracy of the initial temperature of the deep ground soil has greater effect on identified thermal conductivity.