In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model wi...In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.展开更多
The flow patterns in the inlet and outlet conduits have a decisive effect on the safe, stable, and highly efficient operation of the pump in a large pumping station with low head. The numerical simulation of three-dim...The flow patterns in the inlet and outlet conduits have a decisive effect on the safe, stable, and highly efficient operation of the pump in a large pumping station with low head. The numerical simulation of three-dimensional (3D) turbulence flow in conduits is an important method to study the hydraulic performance and conduct an optimum hydraulic design for the conduits. With the analyses of the flow patterns in the inlet and outlet conduits, the boundary conditions of the numerical simulation for them can be determined. The main obtained conclusions are as follows: (i) Under normal operation conditions, there is essentially no pre-swirl flow at the impeller chamber inlet of an axial-flow pump system, based on which the boundary condition at the inlet conduit may be defined. (ii) The circulation at the guide vane outlet of an axial-flow pump system has a great effect on the hydraulic performance of the outlet conduit, and there is optimum circulation for the performance. Therefore, it is strongly suggested to design the guide vane according to the optimum circulation. (iii) The residual circulation at the guide vane outlet needs to be considered for the inlet boundary condition of the outlet conduit, and the value of the circulation may be measured in a specially designed test model.展开更多
Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak ...Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak heat load is proposed.First,on the basis of sewage characteristics,a freezing latent heat exchanger is developed to safely eliminate ice,continuously extract heat and remove sewage soft-dirt.A reasonable form of the urban sewage source heat pump system with freezing latent heat collection is presented.Then,the feasibility of the system is theoretically analyzed.The calculation results under typical operating conditions show that the heating ability of the new system is higher than that of the conventional one and the ratio of these two highest heating rates is between 4.5 and 8.7,which proves that the new system has great application potential in cold regions.展开更多
A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building...A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.展开更多
The relationship between the head loss and the discharge and circulation of the conduit of a pump system with low head is an important problem with an obvious influence on the improvement of its hydraulic performance....The relationship between the head loss and the discharge and circulation of the conduit of a pump system with low head is an important problem with an obvious influence on the improvement of its hydraulic performance. The velocity circulation from the pump guide vane makes the relationship more complicated, which has to be understood comprehensively. The results indicate that, under the condition of zero circulation, the head loss of the inlet and outlet conduits is in proportion to the square of discharge. Under the condition that the Reynolds number is satisfied with the resistant square area, the conduit loss is in proportion to the square of discharge for the similar working points with different speeds in a certain rotational speed range, indicating that the pump system efficiency is constant. The outlet conduit loss of design discharge for a pump system with low head depends on the velocity circulation from the guide vane exit, and the relationship between the loss and the circulation is an open curve with an upward direction, meaning that there is an optimal circulation for the loss. Under the condition of various working points for a pump system with low head, the head loss of the outlet conduit is under the cross influence of both the discharge and the circulation. As a result, the relationship between the head loss and the discharge is almost linear, and the mechanism needs to be further studied.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
This study proposed a battery management approach for the electric hydraulic pump system of a lifting trolley.The pump system was powered by two 12-V lead-acid batteries in series.Because direct measurement of the act...This study proposed a battery management approach for the electric hydraulic pump system of a lifting trolley.The pump system was powered by two 12-V lead-acid batteries in series.Because direct measurement of the actual battery state of charge is unlikely,it has mostly been determined through estimation based on the measured open-circuit voltage.A discharge current will result in a voltage drop and hence a lower voltage during discharge;however,the battery voltage will return to the original open-circuit voltage once the discharge stops.The operating current of the electric hydraulic pump system employed in this study was associated with three factors:the lifting height,lifting load,and battery state of charge.The operating current remained constant during the first half of the lifting phase and increased gradually with the lifting height in the second half.The operating current peaked when the lifting height reached the maximum.The power management approach for the electric hydraulic pump system featured the following basic functions:overcharge protection,overdischarge protection,short-circuit protection,overload protection,and an operating timer established in accordance with the system’s operating current variation.According to the manufacturer-defined maximum lifting load and lifting height of the lifting trolley,this study conducted experiments to obtain the maximum required operating time.An operating time greater than the maximum required operating time indicates the occurrence of an unexpected event,discharge should be stopped until the fault is resolved.展开更多
The contradiction between the increasing material demand and resource,is the country has faced problems,to better solve the material demand and the contradiction between the environment and resources,is applied to the...The contradiction between the increasing material demand and resource,is the country has faced problems,to better solve the material demand and the contradiction between the environment and resources,is applied to the development of new energy,new energy,not only can alleviate people and resources,environment and resources,the contradiction between people and the environment,also can promote the sustainable development of world economy,HVAC technology has emerged a new generation of energysaving technology,HVAC has the characteristics of low consumption,low pollution,is a development of technology,to be promoted for environmentfriendly,resource-conserving society has an important role in promoting.This paper focuses on the HVAC technology,water source heat pump system operation control and energy consumption optimization,for the relevant personnel reference.展开更多
A highly precise and timely diagnosis technology can help effectively monitor and adjust the sucker rod production system(SRPS)used in oil wells to ensure a safe and efficient production.The current diagnosis method i...A highly precise and timely diagnosis technology can help effectively monitor and adjust the sucker rod production system(SRPS)used in oil wells to ensure a safe and efficient production.The current diagnosis method is pattern recognition of a dynamometer card(DC)based on feature extraction and perceptron.The premise of this method is that the training and target data have the same distribution.However,the training data are collected from a field SRPS with different system parameters designed to adapt to production conditions,which may significantly affect the diagnostic accuracy.To address this issue,in this study,an improved model of the sucker rod string(SRS)is derived by adding faultparameter dimensions,with which DCs under 16 working conditions could be generated.Subsequently an adaptive diagnosis method is proposed by taking simulated DCs generated near the working point of the target SRPS as training data.Meanwhile,to further improve the accuracy of the proposed method,the DC features are improved by relative normalization and using additional features of the DC position to increase the distance between different types of samples.The parameters of the perceptron are optimized to promote its discriminability.Finally,the accuracy and real-time performance of the proposed adaptive diagnosis method are validated using field data.展开更多
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system....This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.展开更多
Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditio...Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditions of the attribute index for the suitability zoning of the northwest of Shandong are determined, namely, hydrodynamic condition, geological and hydrogeological condition and geological environment condition. The assessment result is that the total area of the suitable zone is 205.88 km^2, that of relative suitable zone, 1 407.76 km^2, and that of unsuitable zone, 286.8 km^2. The result conforms to the real development situation and provides experience for similar regions needed for selecting and assigning a value to suitability zoning of GSHP.展开更多
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe...In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data.展开更多
Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar ene...Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year's running. It is beneficial for the system to operate for long period.展开更多
Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 syst...Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 system, which is widely used in heat pump systems in China nowadays. It can be indicated that R744/R290 mixture can work efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of R290 is increased, discharge pressure is reduced. Under the nominal working condition, there is an optimum mixture mass fraction of 20/80 for R744/R290 under conventional condensation pressure. Both the heating COPhs (coefficient of performance) and volumetric heating capacity are increased by about 12.62% and 34.24% respectively compared with those of R22 based system. But for the heat sink with a small temperature rise, R744/R290 system has poorer performances than R22 system. When heat transfer pinch point in evaporator and condensation processes is considered, the degree of superheat has a negative influence upon system performances under the given conditions.展开更多
In order to investigate the role of the MexA-MexB-OprM efflux pump system in the pathogenesis of Pseudomonas aeruginosa(PA)-induced pulmonary infection,pulmonary infection models were established by intratracheal inje...In order to investigate the role of the MexA-MexB-OprM efflux pump system in the pathogenesis of Pseudomonas aeruginosa(PA)-induced pulmonary infection,pulmonary infection models were established by intratracheal injection of K767(wild type),nalB(MexA-MexB-OprM up-regulated mutant),and △m exB(knockout) strains,separately.All mice were treated with Meropenem(intraperitoneal injection,100 mg/kg body weight,twice every day),and strain-related pathology,bacteria count,cytokine level,myeloperoxidase(MPO,indicator of neutrophil recruitment) activity,and macrophage inflammatory protein-2(MIP-2) expression were evaluated at early(3rd day post-infection) and late(7th and 14th day post-infection) stages of infection.E-test showed that △mexB was more significantly sensitive to panipenan(ETP),meropenem(MP) and imipenem(IP) than K767 and nalB strains.There was no significant difference in sensitivity to cefepime(TM) among the three stains.In contrast to the K767 and nalB groups,the △ mexB group showed decreased bacteria burden over time and less extensive pathological change.Additionally,MPO activity and levels of inflammatory cytokines(IL-1b,IL-12,and TNF-α) were increased at the early stage(day 3) and decreased at the later stage(day 14).Serum MIP-2 expression level was steadily increased in all three groups from early to late stages,but significantly higher in △m exB group than in K767 and nalB groups(P<0.05).In conclusion,the MexA-MexB-OprM efflux pump system might play an important role in PA-induced chronic pulmonary infection.High expression of the MexA-MexB-OprM efflux pump could increase antibacterial resistance and promote infection.展开更多
Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and t...Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.展开更多
Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2...Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance.展开更多
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is...The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.展开更多
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h...This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.展开更多
A real-time operating system (RTOS), also named OS, is designed based on the hardware platform of MC68376, and is implemented in the electronic control system for unit pump in diesel engine. A parallel and time-base...A real-time operating system (RTOS), also named OS, is designed based on the hardware platform of MC68376, and is implemented in the electronic control system for unit pump in diesel engine. A parallel and time-based task division method is introduced and the multi-task software architecture is built in the software system for electronic unit pump (EUP) system. The V-model software development process is used to control algorithm of each task. The simulation results of the hardware-in-the-loop simulation system (HILSS) and the engine experimental results show that the OS is an efficient real-time kernel, and can meet the real-time demands of EUP system; The built multi-task software system is real-time, determinate and reliable. V-model development is a good development process of control algorithms for EUP system, the control precision of control system can be ensured, and the development cycle and cost are also decreased.展开更多
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B04)China Postdoctoral Science Foundation(No.20090461050)+1 种基金the Project of Researchand Development of Ministry of Housing and Urban-Rural Development ofChina(No.2008-K1-26)the New Century Talent Project of Yangzhou University for Excellent Young Backbone Teacher(2008)
文摘In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.
基金Project supported by the Natural Science Foundation of Jiangsu Higher Education Institutions ofChina(No.12KJD570001)
文摘The flow patterns in the inlet and outlet conduits have a decisive effect on the safe, stable, and highly efficient operation of the pump in a large pumping station with low head. The numerical simulation of three-dimensional (3D) turbulence flow in conduits is an important method to study the hydraulic performance and conduct an optimum hydraulic design for the conduits. With the analyses of the flow patterns in the inlet and outlet conduits, the boundary conditions of the numerical simulation for them can be determined. The main obtained conclusions are as follows: (i) Under normal operation conditions, there is essentially no pre-swirl flow at the impeller chamber inlet of an axial-flow pump system, based on which the boundary condition at the inlet conduit may be defined. (ii) The circulation at the guide vane outlet of an axial-flow pump system has a great effect on the hydraulic performance of the outlet conduit, and there is optimum circulation for the performance. Therefore, it is strongly suggested to design the guide vane according to the optimum circulation. (iii) The residual circulation at the guide vane outlet needs to be considered for the inlet boundary condition of the outlet conduit, and the value of the circulation may be measured in a specially designed test model.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B05-05)the Research Foundation of Education Bureau of Heilongjiang Province,China(No.11551114)the China Postdoctoral Science Foundation(No.20100471438).
文摘Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak heat load is proposed.First,on the basis of sewage characteristics,a freezing latent heat exchanger is developed to safely eliminate ice,continuously extract heat and remove sewage soft-dirt.A reasonable form of the urban sewage source heat pump system with freezing latent heat collection is presented.Then,the feasibility of the system is theoretically analyzed.The calculation results under typical operating conditions show that the heating ability of the new system is higher than that of the conventional one and the ratio of these two highest heating rates is between 4.5 and 8.7,which proves that the new system has great application potential in cold regions.
基金The National Natural Science Foundation of China(No. 51036001 )the Natural Science Foundation of Jiangsu Province(No. BK2010043)
文摘A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.
文摘The relationship between the head loss and the discharge and circulation of the conduit of a pump system with low head is an important problem with an obvious influence on the improvement of its hydraulic performance. The velocity circulation from the pump guide vane makes the relationship more complicated, which has to be understood comprehensively. The results indicate that, under the condition of zero circulation, the head loss of the inlet and outlet conduits is in proportion to the square of discharge. Under the condition that the Reynolds number is satisfied with the resistant square area, the conduit loss is in proportion to the square of discharge for the similar working points with different speeds in a certain rotational speed range, indicating that the pump system efficiency is constant. The outlet conduit loss of design discharge for a pump system with low head depends on the velocity circulation from the guide vane exit, and the relationship between the loss and the circulation is an open curve with an upward direction, meaning that there is an optimal circulation for the loss. Under the condition of various working points for a pump system with low head, the head loss of the outlet conduit is under the cross influence of both the discharge and the circulation. As a result, the relationship between the head loss and the discharge is almost linear, and the mechanism needs to be further studied.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
文摘This study proposed a battery management approach for the electric hydraulic pump system of a lifting trolley.The pump system was powered by two 12-V lead-acid batteries in series.Because direct measurement of the actual battery state of charge is unlikely,it has mostly been determined through estimation based on the measured open-circuit voltage.A discharge current will result in a voltage drop and hence a lower voltage during discharge;however,the battery voltage will return to the original open-circuit voltage once the discharge stops.The operating current of the electric hydraulic pump system employed in this study was associated with three factors:the lifting height,lifting load,and battery state of charge.The operating current remained constant during the first half of the lifting phase and increased gradually with the lifting height in the second half.The operating current peaked when the lifting height reached the maximum.The power management approach for the electric hydraulic pump system featured the following basic functions:overcharge protection,overdischarge protection,short-circuit protection,overload protection,and an operating timer established in accordance with the system’s operating current variation.According to the manufacturer-defined maximum lifting load and lifting height of the lifting trolley,this study conducted experiments to obtain the maximum required operating time.An operating time greater than the maximum required operating time indicates the occurrence of an unexpected event,discharge should be stopped until the fault is resolved.
文摘The contradiction between the increasing material demand and resource,is the country has faced problems,to better solve the material demand and the contradiction between the environment and resources,is applied to the development of new energy,new energy,not only can alleviate people and resources,environment and resources,the contradiction between people and the environment,also can promote the sustainable development of world economy,HVAC technology has emerged a new generation of energysaving technology,HVAC has the characteristics of low consumption,low pollution,is a development of technology,to be promoted for environmentfriendly,resource-conserving society has an important role in promoting.This paper focuses on the HVAC technology,water source heat pump system operation control and energy consumption optimization,for the relevant personnel reference.
基金support by the Major Scientific and Technological Projects of CNPC under Grant no.ZD2019-184-004the National Research Council of Science and Technology Major Project under Grant no.2016ZX05042004+1 种基金the Fundamental Research Funds for the Central University under Grant no.20CX02307Athe Opening Fund of National Engineering Laboratory of Offshore Geophysical and Exploration Equipment under Grant no.20CX02307A
文摘A highly precise and timely diagnosis technology can help effectively monitor and adjust the sucker rod production system(SRPS)used in oil wells to ensure a safe and efficient production.The current diagnosis method is pattern recognition of a dynamometer card(DC)based on feature extraction and perceptron.The premise of this method is that the training and target data have the same distribution.However,the training data are collected from a field SRPS with different system parameters designed to adapt to production conditions,which may significantly affect the diagnostic accuracy.To address this issue,in this study,an improved model of the sucker rod string(SRS)is derived by adding faultparameter dimensions,with which DCs under 16 working conditions could be generated.Subsequently an adaptive diagnosis method is proposed by taking simulated DCs generated near the working point of the target SRPS as training data.Meanwhile,to further improve the accuracy of the proposed method,the DC features are improved by relative normalization and using additional features of the DC position to increase the distance between different types of samples.The parameters of the perceptron are optimized to promote its discriminability.Finally,the accuracy and real-time performance of the proposed adaptive diagnosis method are validated using field data.
基金Supported by Hubei Provincial Natural Science Foundation(2008CDB363)
文摘This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.
基金supported by survey and evaluation of shallow geothermal energy in the main cities,China(12120113077200)
文摘Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditions of the attribute index for the suitability zoning of the northwest of Shandong are determined, namely, hydrodynamic condition, geological and hydrogeological condition and geological environment condition. The assessment result is that the total area of the suitable zone is 205.88 km^2, that of relative suitable zone, 1 407.76 km^2, and that of unsuitable zone, 286.8 km^2. The result conforms to the real development situation and provides experience for similar regions needed for selecting and assigning a value to suitability zoning of GSHP.
文摘In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data.
基金Project(GC06A316) supported by the Key Technologies Research and Development Program of Heilongjiang Province, China Project(11531038) supported by the Program of the Educational Commission of Heilongjiang Province of China.
文摘Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year's running. It is beneficial for the system to operate for long period.
文摘Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 system, which is widely used in heat pump systems in China nowadays. It can be indicated that R744/R290 mixture can work efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of R290 is increased, discharge pressure is reduced. Under the nominal working condition, there is an optimum mixture mass fraction of 20/80 for R744/R290 under conventional condensation pressure. Both the heating COPhs (coefficient of performance) and volumetric heating capacity are increased by about 12.62% and 34.24% respectively compared with those of R22 based system. But for the heat sink with a small temperature rise, R744/R290 system has poorer performances than R22 system. When heat transfer pinch point in evaporator and condensation processes is considered, the degree of superheat has a negative influence upon system performances under the given conditions.
基金supported by grants from the National Natural Science Foundation of China (No. 30873189)the Natural Science Foundation of Hubei Province,China (No.2008CDB165)
文摘In order to investigate the role of the MexA-MexB-OprM efflux pump system in the pathogenesis of Pseudomonas aeruginosa(PA)-induced pulmonary infection,pulmonary infection models were established by intratracheal injection of K767(wild type),nalB(MexA-MexB-OprM up-regulated mutant),and △m exB(knockout) strains,separately.All mice were treated with Meropenem(intraperitoneal injection,100 mg/kg body weight,twice every day),and strain-related pathology,bacteria count,cytokine level,myeloperoxidase(MPO,indicator of neutrophil recruitment) activity,and macrophage inflammatory protein-2(MIP-2) expression were evaluated at early(3rd day post-infection) and late(7th and 14th day post-infection) stages of infection.E-test showed that △mexB was more significantly sensitive to panipenan(ETP),meropenem(MP) and imipenem(IP) than K767 and nalB strains.There was no significant difference in sensitivity to cefepime(TM) among the three stains.In contrast to the K767 and nalB groups,the △ mexB group showed decreased bacteria burden over time and less extensive pathological change.Additionally,MPO activity and levels of inflammatory cytokines(IL-1b,IL-12,and TNF-α) were increased at the early stage(day 3) and decreased at the later stage(day 14).Serum MIP-2 expression level was steadily increased in all three groups from early to late stages,but significantly higher in △m exB group than in K767 and nalB groups(P<0.05).In conclusion,the MexA-MexB-OprM efflux pump system might play an important role in PA-induced chronic pulmonary infection.High expression of the MexA-MexB-OprM efflux pump could increase antibacterial resistance and promote infection.
基金Project(50838009) supported by the National Science Key Foundation 1 tem
文摘Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.
基金Project (2015CB251403) supported by the National Key Basic Research Program of China(973)
文摘Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance.
基金Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,ChinaProject(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
文摘The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
文摘This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.
文摘A real-time operating system (RTOS), also named OS, is designed based on the hardware platform of MC68376, and is implemented in the electronic control system for unit pump in diesel engine. A parallel and time-based task division method is introduced and the multi-task software architecture is built in the software system for electronic unit pump (EUP) system. The V-model software development process is used to control algorithm of each task. The simulation results of the hardware-in-the-loop simulation system (HILSS) and the engine experimental results show that the OS is an efficient real-time kernel, and can meet the real-time demands of EUP system; The built multi-task software system is real-time, determinate and reliable. V-model development is a good development process of control algorithms for EUP system, the control precision of control system can be ensured, and the development cycle and cost are also decreased.