AIM: To evaluate the efficacy and safety of active removal of silicone oil with low and high viscosity through a 23-gauge transconjunctival cannula using an external vacuum pump.METHODS: This study was conducted as a ...AIM: To evaluate the efficacy and safety of active removal of silicone oil with low and high viscosity through a 23-gauge transconjunctival cannula using an external vacuum pump.METHODS: This study was conducted as a prospective, interventional case series. A total of 22 eyes of 21 patients [1000 centistokes(c St): 17 eyes, 5700 c St:5 eyes] were included in this study. All patients underwent active silicone oil removal via the entire lumen of a 23-gauge microcannula with suction pressure of a650-700 mm Hg vacuum using an external vacuum pump. A tubing adaptor from the Total Plus Pak誖(Alcon,Fort Worth, USA) was used to join the microcannula and silicone vacuum tube connected to an external vacuum pump. Main outcome measures were mean removal time,changes of intraocular pressure(IOP) and visual acuity,and intraoperative and postoperative complications.RESULTS: Mean removal time(min) was 1.49±0.43 for1000 c St and 7. 12 ± 1. 27 for 5700 c St. The IOP was18.57±7.48 mm Hg at baseline, 11.68 ±4.55 mm Hg at day1 postoperatively(P <0.001), and 15.95±4.92, 16.82±3.81,17.41 ±3.50, and 17.09 ±3.01 mm Hg after one week, one month, three months, and six months, respectively. All patients showed improved or stabilized visual acuity.There was no occurrence of intraoperative or postoperative complications during the follow up period.CONCLUSION: This technique for active removal of silicone oil through a 23-gauge cannula using an external vacuum pump is fast, effective, and safe as well as economical for silicone oil with both low and high viscosity in all eyes with pseudophakia, aphakia, or phakia.展开更多
A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis...A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis on the system are implemented in order to study the relationships among the characteristics, parameters and working points of the system. The experimental investigations on the system characteristics are presented with the adoption ofa fuzzy-PID controller. The simulation and experimental results indicate that the pressure and vacuum continuous control system based on hybrid pump has good dynamic and static performance, strong robustness and satisfactory adaptability to various system parameters. According to the results, system can successfully gain high accuracy and fast response signal. Also, the mathematical model of system is also testified by the experimental results.展开更多
Vacuum die casting is the optimal method to produce high quality aluminum alloy components.At present,there are still very few systematic studies on vacuum die casting theory and equipment design.On the basis of the e...Vacuum die casting is the optimal method to produce high quality aluminum alloy components.At present,there are still very few systematic studies on vacuum die casting theory and equipment design.On the basis of the existing theories of the vacuum die casting pumping and venting systems,a simplified model is established in this research.The model has an aggregate unit consisted of "vacuum pump + buffer tank" and a cylindrical container(including the shot sleeve,cavity and exhaust channel).The theoretical analysis is carried out between the cavity pressure and the pumping time under different volume models.An auxiliary system for high vacuum die casting is designed based on the above analysis.This system is composed of a vacuum control machine and a new vacuum stop valve.The machine has a human-computer control mode with "programmable logic controller(PLC) + touch screen" and a real-time monitoring function of vacuum degree for buffer tank and die cavity.The vacuum stop valve with the "compressed gas + piston rod + labyrinth groove" structure can realize the function of whole-process vacuum venting.The new system shows great advantages on vacuuming the cavity with a much faster speed by making tests on an existing die casting mold and a 250 t die casting machine.A die cavity pressure less than 10 kPa can be reached within 0.8 s in the experiment and the porosity of castings can be greatly decreased.The systematic studies on vacuum die casting theory and equipment have a great guiding significance for high vacuum die casting,and can also be applied to other high vacuum forming in related theoretical and practical research.展开更多
Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperformance of the cryopanel of the cryocondensatio...Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperformance of the cryopanel of the cryocondensation pumps which are the main vacuum pumps of NBI. In order to optimize the cryoperformance, the requirements for the temperature distribution and the heat load of the cryopanel are analysed and the factors that affect the cryopanel's temperature distribution are studied. The results indicate that the temperature difference of the cryopanel can be reduced by fabricating the cryopanel with high thermal conductivity material, increasing its thickness and cutting the distance between the two upward cooling pipes. The results may be applied to a cryopanel cooled by forced flow liquid helium.展开更多
文摘AIM: To evaluate the efficacy and safety of active removal of silicone oil with low and high viscosity through a 23-gauge transconjunctival cannula using an external vacuum pump.METHODS: This study was conducted as a prospective, interventional case series. A total of 22 eyes of 21 patients [1000 centistokes(c St): 17 eyes, 5700 c St:5 eyes] were included in this study. All patients underwent active silicone oil removal via the entire lumen of a 23-gauge microcannula with suction pressure of a650-700 mm Hg vacuum using an external vacuum pump. A tubing adaptor from the Total Plus Pak誖(Alcon,Fort Worth, USA) was used to join the microcannula and silicone vacuum tube connected to an external vacuum pump. Main outcome measures were mean removal time,changes of intraocular pressure(IOP) and visual acuity,and intraoperative and postoperative complications.RESULTS: Mean removal time(min) was 1.49±0.43 for1000 c St and 7. 12 ± 1. 27 for 5700 c St. The IOP was18.57±7.48 mm Hg at baseline, 11.68 ±4.55 mm Hg at day1 postoperatively(P <0.001), and 15.95±4.92, 16.82±3.81,17.41 ±3.50, and 17.09 ±3.01 mm Hg after one week, one month, three months, and six months, respectively. All patients showed improved or stabilized visual acuity.There was no occurrence of intraoperative or postoperative complications during the follow up period.CONCLUSION: This technique for active removal of silicone oil through a 23-gauge cannula using an external vacuum pump is fast, effective, and safe as well as economical for silicone oil with both low and high viscosity in all eyes with pseudophakia, aphakia, or phakia.
基金This project is supported by National Natural Science Foundation of China (No.50675075).
文摘A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis on the system are implemented in order to study the relationships among the characteristics, parameters and working points of the system. The experimental investigations on the system characteristics are presented with the adoption ofa fuzzy-PID controller. The simulation and experimental results indicate that the pressure and vacuum continuous control system based on hybrid pump has good dynamic and static performance, strong robustness and satisfactory adaptability to various system parameters. According to the results, system can successfully gain high accuracy and fast response signal. Also, the mathematical model of system is also testified by the experimental results.
基金supported by Fujian Provincial Natural Science Foundation of China (Grant No.2007J0170)Xiamen Municipal Natural Science Foundation of China (Grant No.3502Z20093034)
文摘Vacuum die casting is the optimal method to produce high quality aluminum alloy components.At present,there are still very few systematic studies on vacuum die casting theory and equipment design.On the basis of the existing theories of the vacuum die casting pumping and venting systems,a simplified model is established in this research.The model has an aggregate unit consisted of "vacuum pump + buffer tank" and a cylindrical container(including the shot sleeve,cavity and exhaust channel).The theoretical analysis is carried out between the cavity pressure and the pumping time under different volume models.An auxiliary system for high vacuum die casting is designed based on the above analysis.This system is composed of a vacuum control machine and a new vacuum stop valve.The machine has a human-computer control mode with "programmable logic controller(PLC) + touch screen" and a real-time monitoring function of vacuum degree for buffer tank and die cavity.The vacuum stop valve with the "compressed gas + piston rod + labyrinth groove" structure can realize the function of whole-process vacuum venting.The new system shows great advantages on vacuuming the cavity with a much faster speed by making tests on an existing die casting mold and a 250 t die casting machine.A die cavity pressure less than 10 kPa can be reached within 0.8 s in the experiment and the porosity of castings can be greatly decreased.The systematic studies on vacuum die casting theory and equipment have a great guiding significance for high vacuum die casting,and can also be applied to other high vacuum forming in related theoretical and practical research.
基金National Natural Science Foundation of China(No.10575105)
文摘Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperformance of the cryopanel of the cryocondensation pumps which are the main vacuum pumps of NBI. In order to optimize the cryoperformance, the requirements for the temperature distribution and the heat load of the cryopanel are analysed and the factors that affect the cryopanel's temperature distribution are studied. The results indicate that the temperature difference of the cryopanel can be reduced by fabricating the cryopanel with high thermal conductivity material, increasing its thickness and cutting the distance between the two upward cooling pipes. The results may be applied to a cryopanel cooled by forced flow liquid helium.