In order to cut greenhouse-gas emissions and increase energy security,the European Commission stimulates the deployment of intermittent renewable energy sources(IRES) towards 2050.In an electricity system with high sh...In order to cut greenhouse-gas emissions and increase energy security,the European Commission stimulates the deployment of intermittent renewable energy sources(IRES) towards 2050.In an electricity system with high shares of IRES implemented in the network,energy balancing like storage is needed to secure grid stability and smooth demand satisfaction.Pumped hydro storage(PHS) is at this moment the best option for large scale storage.Switzerland has strong ambitions to further develop their PHS sector and become the battery of Europe.In this research,the potential of the Swiss PSH plants is explored,whilst taking inflow into the upper reservoirs of the PHS plants into consideration.To simulate electricity imbalance,Germany is used as a case study.Germany already has a high penetration of IRES and has plans to increase installed IRES capacity.By using an energy planning model(Power Plan),three future scenarios of the German electricity system were designed,each with a different set of IRES installed(solar,mixed and wind).Results show that the Swiss battery ambition offers most benefits to a wind-oriented scenario,reducing both shortages as well as surpluses.Water inflow in Swiss PHS-reservoirs is of minor importance when looking at security of supply,although it was shown that the solarscenario profits more from inflow in terms of system stability.However,a potential conflict was observed in the solar-scenario between the need for electricity storage and the storage of natural inflow,resulting in more surpluses in the system when inflow was taken into account.展开更多
The integration of solar and wind energy into the electrical grid has received global research attention due to their unpredictable characteristics.Because wind energy varies across all timescales of utility activity,...The integration of solar and wind energy into the electrical grid has received global research attention due to their unpredictable characteristics.Because wind energy varies across all timescales of utility activity,renewable energy generation should be supplemented and enhanced,from real-time,minute-to-minute variations to annual alterations influencing long-termstrategy.Wind energy generation does not only fluctuate but is also challenging to accurately forecast the timeframes of significance to electricity decision makers;day-ahead and long-term making plans of framework sufficiency such as meeting the network peak load annually.A utility that integrates wind and solar energy into its electricity mix would understand how to adapt to uncertainty and variability in operations while sustaining grid stability.Due to hydropower’s adaptability,a system using hydropower as one of its generating resources could be precisely adapted to absorb the variability of wind and solar energy.The objective of this research study is to create a hybrid system comprising hydro-wind and solar(Hybrid-HWS)integration for power balancing in an isolated electrical network in Klipkop village,Pretoria region,South Africa.The desirability of designing and building goaf storage tank in regard to capability,the fullness of line throughoutwater pumping,dispensing,storage tank spillage,and pressure difference throughout liquid flow within the storage tanks were preliminary assessed using geotechnical and weather forecasting data from a distinctive area of Klipkop town in Pretoria,South Africa.Different facility hours premised on daylight accessibility are scheduled to balance maximum load at early and late hours.However,in the scenario of electrical power,time shift requiring storage for extended periods of time,such as in terms of hours,Hybrid-HWS has been found to have a crucial role.The results of simulations showed a coordinated process design for Hybrid-HWS Energy Storage(ES)to determine everyday strategic planning in reducing the variability of the system resulting from wind-solar-pumped hydro ES output inadequacies and satisfy daily load demands.It could be recommended that by considering the adaptability characteristics,extremely rapidly,ramping,peaking support and maximum stabilizing aid of the system could be archived with pump-hydro into the energy mix which can provide specific guidelines for energy policymakers.展开更多
In this paper a new market based analytical model is proposed for optimal placement of Wind Turbines (WTs) in power systems. In addition to wind turbines, thermal units (THUs) and Pumped Storage Hydro Power Plants (PS...In this paper a new market based analytical model is proposed for optimal placement of Wind Turbines (WTs) in power systems. In addition to wind turbines, thermal units (THUs) and Pumped Storage Hydro Power Plants (PSHPPs) owners participate in power market. Objective function is defined as participants’ social welfare achieved from power pool and ancillary markets in yearly horizon. Wind turbines have been modeled by probability-generation tree scenarios based on statistical information. We concentrate on investment profits of WTs numbers and its generation capacity beside to PSHPPs and THUs power plants in power systems due to increase in high flexible tools for Independent system operator into the planning and operation planning time interval. For effectiveness evaluation of proposed model, simulation studies are applied on 14-Bus IEEE test power system.展开更多
Influences of water head variations on the performances of a prototype reversible pump turbine are experimentally studied in generating mode within a wide range of load conditions(from 25% to 96% of the rated power). ...Influences of water head variations on the performances of a prototype reversible pump turbine are experimentally studied in generating mode within a wide range of load conditions(from 25% to 96% of the rated power). The pressure fluctuations of the reversible pump turbine at three different water heads(with non-dimensional values being 0.48, 0.71 and 0.90) are measured and compared based on the pressure data recorded in the whole flow passage of the turbine. Furthermore, effects of monitoring points and load variations on the impeller-induced unstable behavior(e.g. blade passing frequency and its harmonics) are quantitatively discussed. Our findings reveal that water head variations play a significant role on the pressure fluctuations and their propagation mechanisms inside the reversible pump turbine.展开更多
文摘In order to cut greenhouse-gas emissions and increase energy security,the European Commission stimulates the deployment of intermittent renewable energy sources(IRES) towards 2050.In an electricity system with high shares of IRES implemented in the network,energy balancing like storage is needed to secure grid stability and smooth demand satisfaction.Pumped hydro storage(PHS) is at this moment the best option for large scale storage.Switzerland has strong ambitions to further develop their PHS sector and become the battery of Europe.In this research,the potential of the Swiss PSH plants is explored,whilst taking inflow into the upper reservoirs of the PHS plants into consideration.To simulate electricity imbalance,Germany is used as a case study.Germany already has a high penetration of IRES and has plans to increase installed IRES capacity.By using an energy planning model(Power Plan),three future scenarios of the German electricity system were designed,each with a different set of IRES installed(solar,mixed and wind).Results show that the Swiss battery ambition offers most benefits to a wind-oriented scenario,reducing both shortages as well as surpluses.Water inflow in Swiss PHS-reservoirs is of minor importance when looking at security of supply,although it was shown that the solarscenario profits more from inflow in terms of system stability.However,a potential conflict was observed in the solar-scenario between the need for electricity storage and the storage of natural inflow,resulting in more surpluses in the system when inflow was taken into account.
基金This study was supported by the DUT Scholarship Scheme Masters:2022(RFA Smart Grid)Funding.
文摘The integration of solar and wind energy into the electrical grid has received global research attention due to their unpredictable characteristics.Because wind energy varies across all timescales of utility activity,renewable energy generation should be supplemented and enhanced,from real-time,minute-to-minute variations to annual alterations influencing long-termstrategy.Wind energy generation does not only fluctuate but is also challenging to accurately forecast the timeframes of significance to electricity decision makers;day-ahead and long-term making plans of framework sufficiency such as meeting the network peak load annually.A utility that integrates wind and solar energy into its electricity mix would understand how to adapt to uncertainty and variability in operations while sustaining grid stability.Due to hydropower’s adaptability,a system using hydropower as one of its generating resources could be precisely adapted to absorb the variability of wind and solar energy.The objective of this research study is to create a hybrid system comprising hydro-wind and solar(Hybrid-HWS)integration for power balancing in an isolated electrical network in Klipkop village,Pretoria region,South Africa.The desirability of designing and building goaf storage tank in regard to capability,the fullness of line throughoutwater pumping,dispensing,storage tank spillage,and pressure difference throughout liquid flow within the storage tanks were preliminary assessed using geotechnical and weather forecasting data from a distinctive area of Klipkop town in Pretoria,South Africa.Different facility hours premised on daylight accessibility are scheduled to balance maximum load at early and late hours.However,in the scenario of electrical power,time shift requiring storage for extended periods of time,such as in terms of hours,Hybrid-HWS has been found to have a crucial role.The results of simulations showed a coordinated process design for Hybrid-HWS Energy Storage(ES)to determine everyday strategic planning in reducing the variability of the system resulting from wind-solar-pumped hydro ES output inadequacies and satisfy daily load demands.It could be recommended that by considering the adaptability characteristics,extremely rapidly,ramping,peaking support and maximum stabilizing aid of the system could be archived with pump-hydro into the energy mix which can provide specific guidelines for energy policymakers.
文摘In this paper a new market based analytical model is proposed for optimal placement of Wind Turbines (WTs) in power systems. In addition to wind turbines, thermal units (THUs) and Pumped Storage Hydro Power Plants (PSHPPs) owners participate in power market. Objective function is defined as participants’ social welfare achieved from power pool and ancillary markets in yearly horizon. Wind turbines have been modeled by probability-generation tree scenarios based on statistical information. We concentrate on investment profits of WTs numbers and its generation capacity beside to PSHPPs and THUs power plants in power systems due to increase in high flexible tools for Independent system operator into the planning and operation planning time interval. For effectiveness evaluation of proposed model, simulation studies are applied on 14-Bus IEEE test power system.
基金supported by the National Natural Science Foundation of China(Grant No.51506051)the Fundamental Research Funds for the Central Universities(Grant No.JB2015RCY04)+2 种基金the Open Research Fund Program of Key Laboratory of Fluid and Power Machinery(Xihua University)Ministry of Education(Grant No.szjj-2017-100-1-001)the Open Research Fund Program of State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources(Grant No.LAPS16014)
文摘Influences of water head variations on the performances of a prototype reversible pump turbine are experimentally studied in generating mode within a wide range of load conditions(from 25% to 96% of the rated power). The pressure fluctuations of the reversible pump turbine at three different water heads(with non-dimensional values being 0.48, 0.71 and 0.90) are measured and compared based on the pressure data recorded in the whole flow passage of the turbine. Furthermore, effects of monitoring points and load variations on the impeller-induced unstable behavior(e.g. blade passing frequency and its harmonics) are quantitatively discussed. Our findings reveal that water head variations play a significant role on the pressure fluctuations and their propagation mechanisms inside the reversible pump turbine.