We study the controlling of the Goos-Hanchen (GH) shifts in reflected and transmitted light beams in the triple coupled InGaAs/GaAs quantum dot (QD) nanostructures with electron tunneling and incoherent pumping fi...We study the controlling of the Goos-Hanchen (GH) shifts in reflected and transmitted light beams in the triple coupled InGaAs/GaAs quantum dot (QD) nanostructures with electron tunneling and incoherent pumping field. It is shown that the lateral shift can become either large negative or large positive, which can be controlled by the electron tunneling and the rate of incoherent pump field in different incident angles. It is also demonstrated that the properties of the OH shifts are strongly dependent on the probe absorption beam of the intracavity medium due to the switching from superluminal light propagation to subluminal behavior or vice versa. Our suggested system can be considered as a new theoretical method for developing a new nano-optoelectronic sensor.展开更多
Driving a hydraulic cylinder directly by a closed-loop hydraulic pump is currently a key research area in the field of electro-hydraulic control technology,and it is the most direct means to improve the energy efficie...Driving a hydraulic cylinder directly by a closed-loop hydraulic pump is currently a key research area in the field of electro-hydraulic control technology,and it is the most direct means to improve the energy efficiency of an electro-hydraulic control system.So far,this technology has been well applied to the pump-controlled symmetric hydraulic cylinder.However,for the differential cylinder that is widely used in hydraulic technology,satisfactory results have not yet been achieved,due to the asymmetric flow constraint.Therefore,based on the principle of the asymmetric valve controlled asymmetric cylinder in valve controlled cylinder technology,an innovative idea for an asymmetric pump controlled asymmetric cylinder is put forward to address this problem.The scheme proposes to transform the oil suction window of the existing axial piston pump into two series windows.When in use,one window is connected to the rod chamber of the hydraulic cylinder and the other is linked with a low-pressure oil tank.This allows the differential cylinders to be directly controlled by changing the displacement or rotation speed of the pumps.Compared with the loop principle of offsetting the area difference of the differential cylinder through hydraulic valve using existing technology,this method may simplify the circuits and increase the energy efficiency of the system.With the software SimulationX,a hydraulic pump simulation model is set up,which examines the movement characteristics of an individual piston and the compressibility of oil,as well as the flow distribution area as it changes with the rotation angle.The pump structure parameters,especially the size of the unloading groove of the valve plate,are determined through digital simulation.All of the components of the series arranged three distribution-window axial piston pump are designed,based on the simulation analysis of the flow pulse characteristics of the pump,and then the prototype pump is made.The basic characteristics,such as the pressure,flow and noise of the pumps under different rotation speeds,are measured on the test bench.The test results verify the correctness of the principle.The proposed research lays a theoretical foundation for the further development of a new pump-controlled cylinder system.展开更多
Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to ...Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to be improved. Microcomputer control of a pump controlled motor electrohydraulic servo system is studied. A PID controller is first adopted on the closed loop control system, and experimental results are obtained. Then, a model reference adaptive controller is designed and realised on the same system applying a single board microcomputer. Experimental results show that the dynamic properties of the adaptive control system is much better than those of the PID system under different inertia load conditions.展开更多
The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated. Considering the wide variat...The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated. Considering the wide variation of the cylinder equivalent mass caused by the transmission ratio of clamping unit and the severe instantaneous impact force acted on the cylinder during the mold closing and opening process, an adaptive control principle of parameter and structure is proposed to improve its kinetic performance. The adaptive correlation between the acceleration feedback gain and the variable mass is derived. The pressure differential feedback is introduced to improve the dynamic performance in the case of small inertia and heavy impact load. The adaptation of sum pressure to load is used to reduce the energy loss of the system. The research results are verified by the simulation and experiment, The investigation method and the conclusions are also suitable for the differential cylinder system controlled by the traditional servo pump unit.展开更多
A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis...A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis on the system are implemented in order to study the relationships among the characteristics, parameters and working points of the system. The experimental investigations on the system characteristics are presented with the adoption ofa fuzzy-PID controller. The simulation and experimental results indicate that the pressure and vacuum continuous control system based on hybrid pump has good dynamic and static performance, strong robustness and satisfactory adaptability to various system parameters. According to the results, system can successfully gain high accuracy and fast response signal. Also, the mathematical model of system is also testified by the experimental results.展开更多
The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation...The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time展开更多
The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a l...The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.展开更多
A linear quadric (LQ) optimal speed control algorithm is proposed for the speed control of a pump controlled motor hydraulic system. The control theme consists of optimal state feedback and disturbing compensation bas...A linear quadric (LQ) optimal speed control algorithm is proposed for the speed control of a pump controlled motor hydraulic system. The control theme consists of optimal state feedback and disturbing compensation based on observation. The optimal state feedback bases on LQ cost function. The disturbing compensation is realized through reconstructing the state of load torque. A series of simulation are performed, and the results show that the control performance is satisfactory and can be maintained under changes of load torque.展开更多
In this paper controlled porosity osmotic pump tablets(CPOPT)for salvianolic acid(SA)were prepared and optimized with experimental design methods including an artificial neutral network(ANN)method.Three causal factors...In this paper controlled porosity osmotic pump tablets(CPOPT)for salvianolic acid(SA)were prepared and optimized with experimental design methods including an artificial neutral network(ANN)method.Three causal factors,i.e.,drug,osmotic pressure promoting agent rate,PEG400 content in coating solution and coating weight,were evaluated based on their effects on drug release rate.The linear correlation coefficient of the accumulative amount of drug release and the time of 12 h,r(Y_(1)),and the sum of the absolute value between measured and projected values,Y_(2),were used as outputs to optimize the formulation.The weight expression Y=(1-Y_(1))^(2)+Y_(2)^(2) was used in the calculation.Furthermore,the ANN and uniform design gave similar optimization results,but ANN projected the outputs better than the uniform design.This paper showed that the release rate of salvianolic acid B and that of the total salvianolic acid was consistent in the optimized formulation.展开更多
Background Ion pump control system of HIRFL is designed based on the real-time distributed control software,EPICS.The hardware architecture,communication principle,database design and interlock design are introduced a...Background Ion pump control system of HIRFL is designed based on the real-time distributed control software,EPICS.The hardware architecture,communication principle,database design and interlock design are introduced and elaborated in the paper.Methods PLC has been adopted to realize functions such as control monitoring and data communication.Interlock protect ion has been designed for ion pump control system to prevent damaging from high voltage.Results The test results show that the system has fast response function and high-speed data processing during the beam running and tuning.The response time of the system could reach 100 ms,the rate of data acquisition reaches to 10 time/s and the interlock protection time less than 40 ms.Conclusion The reliable and stable long-term operation of the vacuum system indicates that the performance has been constantly improved with the continuous optimization of the ion pump control system.展开更多
A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than ...A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than 0.5dB excursion and 0.25dB offset.展开更多
Temporal cavity solitons(CSs) have excellent properties that can sustain their shape in a temporal profile and with a broadband, smooth-frequency spectrum. We propose a method for controllable frequency line spacing...Temporal cavity solitons(CSs) have excellent properties that can sustain their shape in a temporal profile and with a broadband, smooth-frequency spectrum. We propose a method for controllable frequency line spacing soliton formation in a microresonator using two continuous-wave(CW) pumps with multi-free-spectral-range(FSR) spacing. The method we propose has better control over the amount and location of the solitons traveling in the cavity compared to the tuning pump method. We also find that by introducing a second pump with frequency N FSR from the first pump, solitons with N FSR comb spacing can be generated.展开更多
文摘We study the controlling of the Goos-Hanchen (GH) shifts in reflected and transmitted light beams in the triple coupled InGaAs/GaAs quantum dot (QD) nanostructures with electron tunneling and incoherent pumping field. It is shown that the lateral shift can become either large negative or large positive, which can be controlled by the electron tunneling and the rate of incoherent pump field in different incident angles. It is also demonstrated that the properties of the OH shifts are strongly dependent on the probe absorption beam of the intracavity medium due to the switching from superluminal light propagation to subluminal behavior or vice versa. Our suggested system can be considered as a new theoretical method for developing a new nano-optoelectronic sensor.
基金supported by National Natural Science Foundation of China (Grant No. 50775156)Open Fund of The State Key Lab of Fluid Power Transmission and Control of Zhejiang University, China (Grant No. GZKF-2008006)
文摘Driving a hydraulic cylinder directly by a closed-loop hydraulic pump is currently a key research area in the field of electro-hydraulic control technology,and it is the most direct means to improve the energy efficiency of an electro-hydraulic control system.So far,this technology has been well applied to the pump-controlled symmetric hydraulic cylinder.However,for the differential cylinder that is widely used in hydraulic technology,satisfactory results have not yet been achieved,due to the asymmetric flow constraint.Therefore,based on the principle of the asymmetric valve controlled asymmetric cylinder in valve controlled cylinder technology,an innovative idea for an asymmetric pump controlled asymmetric cylinder is put forward to address this problem.The scheme proposes to transform the oil suction window of the existing axial piston pump into two series windows.When in use,one window is connected to the rod chamber of the hydraulic cylinder and the other is linked with a low-pressure oil tank.This allows the differential cylinders to be directly controlled by changing the displacement or rotation speed of the pumps.Compared with the loop principle of offsetting the area difference of the differential cylinder through hydraulic valve using existing technology,this method may simplify the circuits and increase the energy efficiency of the system.With the software SimulationX,a hydraulic pump simulation model is set up,which examines the movement characteristics of an individual piston and the compressibility of oil,as well as the flow distribution area as it changes with the rotation angle.The pump structure parameters,especially the size of the unloading groove of the valve plate,are determined through digital simulation.All of the components of the series arranged three distribution-window axial piston pump are designed,based on the simulation analysis of the flow pulse characteristics of the pump,and then the prototype pump is made.The basic characteristics,such as the pressure,flow and noise of the pumps under different rotation speeds,are measured on the test bench.The test results verify the correctness of the principle.The proposed research lays a theoretical foundation for the further development of a new pump-controlled cylinder system.
基金The Project Supported by Doctoral Programme Foundation of Institution of Higher Education
文摘Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to be improved. Microcomputer control of a pump controlled motor electrohydraulic servo system is studied. A PID controller is first adopted on the closed loop control system, and experimental results are obtained. Then, a model reference adaptive controller is designed and realised on the same system applying a single board microcomputer. Experimental results show that the dynamic properties of the adaptive control system is much better than those of the PID system under different inertia load conditions.
基金This project is supported by National Natural Science Foundation of China (No.50275102)Opening Foundation of State Key Lab of Fluid Power Transmission and Control of Zhejiang University, China (No.GZKF2002004).
文摘The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated. Considering the wide variation of the cylinder equivalent mass caused by the transmission ratio of clamping unit and the severe instantaneous impact force acted on the cylinder during the mold closing and opening process, an adaptive control principle of parameter and structure is proposed to improve its kinetic performance. The adaptive correlation between the acceleration feedback gain and the variable mass is derived. The pressure differential feedback is introduced to improve the dynamic performance in the case of small inertia and heavy impact load. The adaptation of sum pressure to load is used to reduce the energy loss of the system. The research results are verified by the simulation and experiment, The investigation method and the conclusions are also suitable for the differential cylinder system controlled by the traditional servo pump unit.
基金This project is supported by National Natural Science Foundation of China (No.50675075).
文摘A novel pressure and vacuum continuous control system, which adopts a hybrid pump as pressure and vacuum source, is presented. The mathematical model of the system is developed. The theoretical simulation and analysis on the system are implemented in order to study the relationships among the characteristics, parameters and working points of the system. The experimental investigations on the system characteristics are presented with the adoption ofa fuzzy-PID controller. The simulation and experimental results indicate that the pressure and vacuum continuous control system based on hybrid pump has good dynamic and static performance, strong robustness and satisfactory adaptability to various system parameters. According to the results, system can successfully gain high accuracy and fast response signal. Also, the mathematical model of system is also testified by the experimental results.
文摘The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time
文摘The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.
文摘A linear quadric (LQ) optimal speed control algorithm is proposed for the speed control of a pump controlled motor hydraulic system. The control theme consists of optimal state feedback and disturbing compensation based on observation. The optimal state feedback bases on LQ cost function. The disturbing compensation is realized through reconstructing the state of load torque. A series of simulation are performed, and the results show that the control performance is satisfactory and can be maintained under changes of load torque.
文摘In this paper controlled porosity osmotic pump tablets(CPOPT)for salvianolic acid(SA)were prepared and optimized with experimental design methods including an artificial neutral network(ANN)method.Three causal factors,i.e.,drug,osmotic pressure promoting agent rate,PEG400 content in coating solution and coating weight,were evaluated based on their effects on drug release rate.The linear correlation coefficient of the accumulative amount of drug release and the time of 12 h,r(Y_(1)),and the sum of the absolute value between measured and projected values,Y_(2),were used as outputs to optimize the formulation.The weight expression Y=(1-Y_(1))^(2)+Y_(2)^(2) was used in the calculation.Furthermore,the ANN and uniform design gave similar optimization results,but ANN projected the outputs better than the uniform design.This paper showed that the release rate of salvianolic acid B and that of the total salvianolic acid was consistent in the optimized formulation.
基金National Nature Science Foundation of China under Grant No.U1632141 and Western Light Foundation of Chinese Academy of Science under Grant No.29Y926040.
文摘Background Ion pump control system of HIRFL is designed based on the real-time distributed control software,EPICS.The hardware architecture,communication principle,database design and interlock design are introduced and elaborated in the paper.Methods PLC has been adopted to realize functions such as control monitoring and data communication.Interlock protect ion has been designed for ion pump control system to prevent damaging from high voltage.Results The test results show that the system has fast response function and high-speed data processing during the beam running and tuning.The response time of the system could reach 100 ms,the rate of data acquisition reaches to 10 time/s and the interlock protection time less than 40 ms.Conclusion The reliable and stable long-term operation of the vacuum system indicates that the performance has been constantly improved with the continuous optimization of the ion pump control system.
文摘A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than 0.5dB excursion and 0.25dB offset.
基金supported by the National Natural Science Foundation of China (Grant Nos. 61475099, 61102053, 61378012, and 11574092)the Program of State Key Laboratory of Quantum Optics and Quantum Optics Devices (No. KF201405)the Open Fund of IPOC (BUPT) (No: IPOC2015B004)
文摘Temporal cavity solitons(CSs) have excellent properties that can sustain their shape in a temporal profile and with a broadband, smooth-frequency spectrum. We propose a method for controllable frequency line spacing soliton formation in a microresonator using two continuous-wave(CW) pumps with multi-free-spectral-range(FSR) spacing. The method we propose has better control over the amount and location of the solitons traveling in the cavity compared to the tuning pump method. We also find that by introducing a second pump with frequency N FSR from the first pump, solitons with N FSR comb spacing can be generated.