This paper analyzed GPS data from the Topo-Iberia network spanning almost 12 years(2008-2020).The data quality information for all 26 Topo-Iberia stations is provided for the first time,complementing the Spanish Geolo...This paper analyzed GPS data from the Topo-Iberia network spanning almost 12 years(2008-2020).The data quality information for all 26 Topo-Iberia stations is provided for the first time,complementing the Spanish Geological Survey’s storage work.Data analyses based on quality indicators obtained using TEQC have been carried out.The guidelines and data quality information from the IGS stations have been considered as the quality references,with the stations ALJI,EPCU,and TIOU standing out as the worst stations,while on the contrary,FUEN,PALM,PILA,and TRIA meet the quality requirements to become an IGS station.The relationship between the GPS data quality and their GAMIT-and Gipsy X-derived postfit ionosphere-free phase residuals has also been investigated,and the results reveal an inversely proportional relationship.It has been found that the stations showing an increase in elevation of the horizon line,also show an increase in cycle slips and multipath,are among the poorest quality stations,and among those with the highest postfit RMS of phase residuals.Moreover,the evolution of the vegetation around the antenna should be considered as it could cause a progressive loss of quality,which is not complying with the IGS standards.The quality assessment shows that the Topo-Iberia stations are appropriate for geodetic purposes,but permanent monitoring would be necessary to avoid the least possible loss of data and quality.In addition,a method to characterize the GNSS data quality is proposed.展开更多
Acid mine drainage (AMD) is one of the major problems in high sulfur coal mining areas generating acidic water. The acidic mine water generated contain hazardous elements in varying concentrations. The Northeastern ...Acid mine drainage (AMD) is one of the major problems in high sulfur coal mining areas generating acidic water. The acidic mine water generated contain hazardous elements in varying concentrations. The Northeastern Indian coalfield produces considerable amounts of AMD. The AMD and metal leaching from coal and mine over burden (OB) are the two important naturally occurring processes. In order to know the AMD potential, the aqueous leaching experiment of a few coal and OB samples from the Ledo colliery of the Northeastern coalfield, Mergherita (India), at different time periods (1, 3, 5, and 8 h) and at different temperatures (25, 45, 65, and 90℃) were performed in the laboratory. The physico- chemical analysis of the aqueous leachates shows the pH, electrical conductivity (EC), and total dissolved solid (TDS) in the range of 1.62-3.52, 106-2006 μs/cm, and 106-1003 ppm for the raw coal samples respectively. The OB samples produced pH, EC, and TDS in the range of 3.68-6.92, 48.6-480 μs/cm, and 69.5-240 ppm respectively. From the study, it was revealed that the concentrations of major (Si, A1, K, Na, Fe, Ca, Mg), minor (Mn) and trace/hazardous elements (As, Ba, Cd, Co, Cr, Cu, Hg, Ni, Pb, Se, Zn) considerably change with leaching time as well as with leaching temperature. Out of these elements As, Cd, Hg, Pb, Cr, and Se are of greater environmental importance. Alteration of the physico-chemical structure of the coal and OB samples resulting from leaching was also studied by field emission scanning electron microscope- energy-dispersive X-ray spectroscopy method. The release of the potentially hazardous elements from the raw coal and OB during leaching time periods to the leachates was detected by inductively coupled plasma-atomic emission spectroscopy and ion-chromatographic analyses. The major minerals found in coal and OB are quartz (SiO2), pyrite (FeS2), hematite, marcasite, and kaolinite. The association of different functional groups in minerals and their mode of association were studied by Fourier-transform infrared spectroscopy and X-ray diffraction analytical techniques. The present laboratory study will be useful in relating the characteristics of aqueous leaching from coal and mine OB with the natural weathering condition at the coal mine area.展开更多
Quality assessment systems for business organisations and also for vocational schools were established in Estonia at the beginning of 2000s. Almost ten years later, corresponding systems were introduced also for highe...Quality assessment systems for business organisations and also for vocational schools were established in Estonia at the beginning of 2000s. Almost ten years later, corresponding systems were introduced also for higher education institutions (HEIs). All these assessment systems are based on the European Foundation of Quality Management (EFQM) excellence model. The aim of this paper is to analyse benefits, difficulties, and success factors of quality assessment processes in Estonian business organisations, vocational schools, and HEIs. The study is based on the analysis of feedback questionnaire of 404 representatives from participating organisations (HEIs, vocational schools, and business enterprises) and assessors. Our analysis revealed that quality assessment processes including self-assessment reporting had a positive effect on organisation development and it has given the participants certain benefits and new challenges. As a consequence, knowledge about quality management as well as the self-assessment skills has been improved. The main difficulties were connected to limited time resources and with problems to recognize direct benefits of quality assessment. As substantial difficulties, limitations of analytical and report-writing skills were considered. As the biggest success factor, an involvement of managers on different levels decision making was recognized. The analysis revealed that there are a number of similar benefits and difficulties in the quality assessment systems of different organizations.展开更多
基金supported in part by the University of Jaén and the Spanish Ministry of Economy, Industry and Competitiveness (PTA2015-11507-I MINECO)。
文摘This paper analyzed GPS data from the Topo-Iberia network spanning almost 12 years(2008-2020).The data quality information for all 26 Topo-Iberia stations is provided for the first time,complementing the Spanish Geological Survey’s storage work.Data analyses based on quality indicators obtained using TEQC have been carried out.The guidelines and data quality information from the IGS stations have been considered as the quality references,with the stations ALJI,EPCU,and TIOU standing out as the worst stations,while on the contrary,FUEN,PALM,PILA,and TRIA meet the quality requirements to become an IGS station.The relationship between the GPS data quality and their GAMIT-and Gipsy X-derived postfit ionosphere-free phase residuals has also been investigated,and the results reveal an inversely proportional relationship.It has been found that the stations showing an increase in elevation of the horizon line,also show an increase in cycle slips and multipath,are among the poorest quality stations,and among those with the highest postfit RMS of phase residuals.Moreover,the evolution of the vegetation around the antenna should be considered as it could cause a progressive loss of quality,which is not complying with the IGS standards.The quality assessment shows that the Topo-Iberia stations are appropriate for geodetic purposes,but permanent monitoring would be necessary to avoid the least possible loss of data and quality.In addition,a method to characterize the GNSS data quality is proposed.
文摘Acid mine drainage (AMD) is one of the major problems in high sulfur coal mining areas generating acidic water. The acidic mine water generated contain hazardous elements in varying concentrations. The Northeastern Indian coalfield produces considerable amounts of AMD. The AMD and metal leaching from coal and mine over burden (OB) are the two important naturally occurring processes. In order to know the AMD potential, the aqueous leaching experiment of a few coal and OB samples from the Ledo colliery of the Northeastern coalfield, Mergherita (India), at different time periods (1, 3, 5, and 8 h) and at different temperatures (25, 45, 65, and 90℃) were performed in the laboratory. The physico- chemical analysis of the aqueous leachates shows the pH, electrical conductivity (EC), and total dissolved solid (TDS) in the range of 1.62-3.52, 106-2006 μs/cm, and 106-1003 ppm for the raw coal samples respectively. The OB samples produced pH, EC, and TDS in the range of 3.68-6.92, 48.6-480 μs/cm, and 69.5-240 ppm respectively. From the study, it was revealed that the concentrations of major (Si, A1, K, Na, Fe, Ca, Mg), minor (Mn) and trace/hazardous elements (As, Ba, Cd, Co, Cr, Cu, Hg, Ni, Pb, Se, Zn) considerably change with leaching time as well as with leaching temperature. Out of these elements As, Cd, Hg, Pb, Cr, and Se are of greater environmental importance. Alteration of the physico-chemical structure of the coal and OB samples resulting from leaching was also studied by field emission scanning electron microscope- energy-dispersive X-ray spectroscopy method. The release of the potentially hazardous elements from the raw coal and OB during leaching time periods to the leachates was detected by inductively coupled plasma-atomic emission spectroscopy and ion-chromatographic analyses. The major minerals found in coal and OB are quartz (SiO2), pyrite (FeS2), hematite, marcasite, and kaolinite. The association of different functional groups in minerals and their mode of association were studied by Fourier-transform infrared spectroscopy and X-ray diffraction analytical techniques. The present laboratory study will be useful in relating the characteristics of aqueous leaching from coal and mine OB with the natural weathering condition at the coal mine area.
文摘Quality assessment systems for business organisations and also for vocational schools were established in Estonia at the beginning of 2000s. Almost ten years later, corresponding systems were introduced also for higher education institutions (HEIs). All these assessment systems are based on the European Foundation of Quality Management (EFQM) excellence model. The aim of this paper is to analyse benefits, difficulties, and success factors of quality assessment processes in Estonian business organisations, vocational schools, and HEIs. The study is based on the analysis of feedback questionnaire of 404 representatives from participating organisations (HEIs, vocational schools, and business enterprises) and assessors. Our analysis revealed that quality assessment processes including self-assessment reporting had a positive effect on organisation development and it has given the participants certain benefits and new challenges. As a consequence, knowledge about quality management as well as the self-assessment skills has been improved. The main difficulties were connected to limited time resources and with problems to recognize direct benefits of quality assessment. As substantial difficulties, limitations of analytical and report-writing skills were considered. As the biggest success factor, an involvement of managers on different levels decision making was recognized. The analysis revealed that there are a number of similar benefits and difficulties in the quality assessment systems of different organizations.