期刊文献+
共找到52,330篇文章
< 1 2 250 >
每页显示 20 50 100
Accurate method based on data filtering for quantitative multi-element analysis of soils using CF-LIBS
1
作者 韩伟伟 孙对兄 +7 位作者 张国鼎 董光辉 崔小娜 申金成 王浩亮 张登红 董晨钟 苏茂根 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期149-158,共10页
To obtain more stable spectral data for accurate quantitative analysis of multi-element,especially for the large-area in-situ elements detection of soils, we propose a method for a multielement quantitative analysis o... To obtain more stable spectral data for accurate quantitative analysis of multi-element,especially for the large-area in-situ elements detection of soils, we propose a method for a multielement quantitative analysis of soils using calibration-free laser-induced breakdown spectroscopy(CF-LIBS) based on data filtering. In this study, we analyze a standard soil sample doped with two heavy metal elements, Cu and Cd, with a specific focus on the line of Cu I324.75 nm for filtering the experimental data of multiple sample sets. Pre-and post-data filtering,the relative standard deviation for Cu decreased from 30% to 10%, The limits of detection(LOD)values for Cu and Cd decreased by 5% and 4%, respectively. Through CF-LIBS, a quantitative analysis was conducted to determine the relative content of elements in soils. Using Cu as a reference, the concentration of Cd was accurately calculated. The results show that post-data filtering, the average relative error of the Cd decreases from 11% to 5%, indicating the effectiveness of data filtering in improving the accuracy of quantitative analysis. Moreover, the content of Si, Fe and other elements can be accurately calculated using this method. To further correct the calculation, the results for Cd was used to provide a more precise calculation. This approach is of great importance for the large-area in-situ heavy metals and trace elements detection in soil, as well as for rapid and accurate quantitative analysis. 展开更多
关键词 laser-induced breakdown spectroscopy SOIL data filtering quantitative analysis multielement
下载PDF
Research on batch multielement rapid quantitative analysis based on the standard curve-assisted calibration-free laserinduced breakdown spectroscopy method
2
作者 Weiwei HAN Duixiong SUN +7 位作者 Guoding ZHANG Honglin WANG Kai GUO Yuzhuo ZHANG Haoliang WANG Denghong ZHANG Chenzhong DONG Maogen SU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期156-164,共9页
This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to ach... This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to achieve synchronous,rapid,and accurate measurement of elements in a large number of samples,namely,SC-assisted CF-LIBS.Al alloy standard samples,divided into calibration and test samples,were applied to validate the proposed method.SC was built based on the characteristic line of Pb and Cr in the calibration sample,and the contents of Pb and Cr in the test sample were calculated with relative errors of 6%and 4%,respectively.SC built using Cr with multiple characteristic lines yielded better calculation results.The relative contents of ten elements in the test sample were calculated using CF-LIBS.Subsequently,the SC-assisted CF-LIBS was executed,with the majority of the calculation relative errors falling within the range of 2%-5%.Finally,the Al and Na contents of the Al alloy were predicted.The results demonstrate that it effectively enables the rapid and accurate quantitative analysis of multiple elements after a single-element SC analysis of the tested samples.Furthermore,this quantitative analysis method was successfully applied to soil and Astragalus samples,realizing an accurate calculation of the contents of multiple elements.Thus,it is important to advance the LIBS quantitative analysis and its related applications. 展开更多
关键词 laser-induced breakdown spectroscopy standard curve quantitative analysis multielement
下载PDF
Simplified quantitative analysis method and its application in the insitu synthesized copper-based azide chips
3
作者 Jie Ren Yunfeng Li +3 位作者 Mingyu Li Xingyu Wu Jiabao Wang Qingxuan Zeng 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第2期309-316,共8页
Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ ... Copper-based azide(Cu(N_(3))2 or CuN_(3),CA)chips synthesized by in-situ azide reaction and utilized in miniaturized explosive systems has become a hot research topic in recent years.However,the advantages of in-situ synthesis method,including small size and low dosage,bring about difficulties in quantitative analysis and differences in ignition capabilities of CA chips.The aim of present work is to develop a simplified quantitative analysis method for accurate and safe analysis of components in CA chips to evaluate and investigate the corresponding ignition ability.In this work,Cu(N_(3))2 and CuN_(3)components in CA chips were separated through dissolution and distillation by utilizing the difference in solubility and corresponding content was obtained by measuring N_(3)-concentration through spectrophotometry.The spectrophotometry method was optimized by studying influencing factors and the recovery rate of different separation methods was studied,ensuring the accuracy and reproducibility of test results.The optimized method is linear in range from 1.0-25.0 mg/L,with a correlation coefficient R^(2)=0.9998,which meets the requirements of CA chips with a milligram-level content test.Compared with the existing ICP method,component analysis results of CA chips obtained by spectrophotometry are closer to real component content in samples and have satisfactory accuracy.Moreover,as its application in miniaturized explosive systems,the ignition ability of CA chips with different component contents for direct ink writing CL-20 and the corresponding mechanism was studied.This study provided a basis and idea for the design and performance evaluation of CA chips in miniaturized explosive systems. 展开更多
关键词 Copper-based azide chips SPECTROPHOTOMETRY Separation method quantitative analysis Ignition ability
下载PDF
Novel damage constitutive models and new quantitative identification method for stress thresholds of rocks under uniaxial compression
4
作者 DU Kun YI Yang +3 位作者 LUO Xin-yao LIU Kai LI Peng WANG Shao-feng 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第8期2658-2675,共18页
Four key stress thresholds exist in the compression process of rocks,i.e.,crack closure stress(σ_(cc)),crack initiation stress(σ_(ci)),crack damage stress(σ_(cd))and compressive strength(σ_(c)).The quantitative id... Four key stress thresholds exist in the compression process of rocks,i.e.,crack closure stress(σ_(cc)),crack initiation stress(σ_(ci)),crack damage stress(σ_(cd))and compressive strength(σ_(c)).The quantitative identifications of the first three stress thresholds are of great significance for characterizing the microcrack growth and damage evolution of rocks under compression.In this paper,a new method based on damage constitutive model is proposed to quantitatively measure the stress thresholds of rocks.Firstly,two different damage constitutive models were constructed based on acoustic emission(AE)counts and Weibull distribution function considering the compaction stages of the rock and the bearing capacity of the damage element.Then,the accumulative AE counts method(ACLM),AE count rate method(CRM)and constitutive model method(CMM)were introduced to determine the stress thresholds of rocks.Finally,the stress thresholds of 9 different rocks were identified by ACLM,CRM,and CMM.The results show that the theoretical stress−strain curves obtained from the two damage constitutive models are in good agreement with that of the experimental data,and the differences between the two damage constitutive models mainly come from the evolutionary differences of the damage variables.The results of the stress thresholds identified by the CMM are in good agreement with those identified by the AE methods,i.e.,ACLM and CRM.Therefore,the proposed CMM can be used to determine the stress thresholds of rocks. 展开更多
关键词 stress threshold acoustic emission damage constitutive model damage element quantitative method
下载PDF
Study on Quantitative Precipitation Estimation by Polarimetric Radar Using Deep Learning
5
作者 Jiang HUANGFU Zhiqun HU +2 位作者 Jiafeng ZHENG Lirong WANG Yongjie ZHU 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第6期1147-1160,共14页
Accurate radar quantitative precipitation estimation(QPE)plays an essential role in disaster prevention and mitigation.In this paper,two deep learning-based QPE networks including a single-parameter network and a mult... Accurate radar quantitative precipitation estimation(QPE)plays an essential role in disaster prevention and mitigation.In this paper,two deep learning-based QPE networks including a single-parameter network and a multi-parameter network are designed.Meanwhile,a self-defined loss function(SLF)is proposed during modeling.The dataset includes Shijiazhuang S-band dual polarimetric radar(CINRAD/SAD)data and rain gauge data within the radar’s 100-km detection range during the flood season of 2021 in North China.Considering that the specific propagation phase shift(KDP)has a roughly linear relationship with the precipitation intensity,KDP is set to 0.5°km^(-1 )as a threshold value to divide all the rain data(AR)into a heavy rain(HR)and light rain(LR)dataset.Subsequently,12 deep learning-based QPE models are trained according to the input radar parameters,the precipitation datasets,and whether an SLF was adopted,respectively.The results suggest that the effects of QPE after distinguishing rainfall intensity are better than those without distinguishing,and the effects of using SLF are better than those that used MSE as a loss function.A Z-R relationship and a ZH-KDP-R synthesis method are compared with deep learning-based QPE.The mean relative errors(MRE)of AR models using SLF are improved by 61.90%,51.21%,and 56.34%compared with the Z-R relational method,and by 38.63%,42.55%,and 47.49%compared with the synthesis method.Finally,the models are further evaluated in three precipitation processes,which manifest that the deep learning-based models have significant advantages over the traditional empirical formula methods. 展开更多
关键词 polarimetric radar quantitative precipitation estimation deep learning single-parameter network multi-parameter network
下载PDF
Quantitative analysis and prediction of the sound field convergence zone in mesoscale eddy environment based on data mining methods
6
作者 Ming Li Yuhang Liu +1 位作者 Yiyuan Sun Kefeng Liu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第5期110-120,共11页
The mesoscale eddy(ME)has a significant influence on the convergence effect in deep-sea acoustic propagation.This paper use statistical approaches to express quantitative relationships between the ME conditions and co... The mesoscale eddy(ME)has a significant influence on the convergence effect in deep-sea acoustic propagation.This paper use statistical approaches to express quantitative relationships between the ME conditions and convergence zone(CZ)characteristics.Based on the Gaussian vortex model,we construct various sound propagation scenarios under different eddy conditions,and carry out sound propagation experiments to obtain simulation samples.With a large number of samples,we first adopt the unified regression to set up analytic relationships between eddy conditions and CZ parameters.The sensitivity of eddy indicators to the CZ is quantitatively analyzed.Then,we adopt the machine learning(ML)algorithms to establish prediction models of CZ parameters by exploring the nonlinear relationships between multiple ME indicators and CZ parameters.Through the research,we can express the influence of ME on the CZ quantitatively,and achieve the rapid prediction of CZ parameters in ocean eddies.The prediction accuracy(R)of the CZ distance(mean R:0.9815)is obviously better than that of the CZ width(mean R:0.8728).Among the three ML algorithms,Gradient Boosting Decision Tree has the best prediction ability(root mean square error(RMSE):0.136),followed by Random Forest(RMSE:0.441)and Extreme Learning Machine(RMSE:0.518). 展开更多
关键词 convergence zone mesoscale eddy statistic analysis quantitative prediction machine learning
下载PDF
Artificial Immune Detection for Network Intrusion Data Based on Quantitative Matching Method
7
作者 CaiMing Liu Yan Zhang +1 位作者 Zhihui Hu Chunming Xie 《Computers, Materials & Continua》 SCIE EI 2024年第2期2361-2389,共29页
Artificial immune detection can be used to detect network intrusions in an adaptive approach and proper matching methods can improve the accuracy of immune detection methods.This paper proposes an artificial immune de... Artificial immune detection can be used to detect network intrusions in an adaptive approach and proper matching methods can improve the accuracy of immune detection methods.This paper proposes an artificial immune detection model for network intrusion data based on a quantitative matching method.The proposed model defines the detection process by using network data and decimal values to express features and artificial immune mechanisms are simulated to define immune elements.Then,to improve the accuracy of similarity calculation,a quantitative matching method is proposed.The model uses mathematical methods to train and evolve immune elements,increasing the diversity of immune recognition and allowing for the successful detection of unknown intrusions.The proposed model’s objective is to accurately identify known intrusions and expand the identification of unknown intrusions through signature detection and immune detection,overcoming the disadvantages of traditional methods.The experiment results show that the proposed model can detect intrusions effectively.It has a detection rate of more than 99.6%on average and a false alarm rate of 0.0264%.It outperforms existing immune intrusion detection methods in terms of comprehensive detection performance. 展开更多
关键词 Immune detection network intrusion network data signature detection quantitative matching method
下载PDF
Clinical Value of the Quantitative Flow Ratio to Predict Long-term Target Vessel Failure in Patients with In-stent Restenosis after Drug-coated Balloon Angioplasty
8
作者 Xiang-qi WU Long-bo LI +6 位作者 Wei YOU Zhi-ming WU Lei ZHAO Zhi-hui WANG Pei-na MENG Bin LIU Fei YE 《Current Medical Science》 SCIE CAS 2024年第3期561-567,共7页
Objective The study sought to investigate the clinical predictive value of quantitative flow ratio(QFR)for the long-term target vessel failure(TVF)outcome in patients with in-stent restenosis(ISR)by using drug-coated ... Objective The study sought to investigate the clinical predictive value of quantitative flow ratio(QFR)for the long-term target vessel failure(TVF)outcome in patients with in-stent restenosis(ISR)by using drug-coated balloon(DCB)treatment after a long-term follow-up.Methods This was a retrospective study.A total of 186 patients who underwent DCB angioplasty for ISR in two hospitals from March 2014 to September 2019 were enrolled.The QFR of the entire target vessel was measured offline.The primary endpoint was TVF,including target vessel-cardiac death(TV-CD),target vessel-myocardial infarction(TV-MI),and clinically driven-target vessel revascularization(CD-TVR).Results The follow-up time was 3.09±1.53 years,and 50 patients had TVF.The QFR immediately after percutaneous coronary intervention(PCI)was significantly lower in the TVF group than in the no-TVF group.Multivariable Cox regression analysis indicated that the QFR immediately after PCI was an excellent predictor for TVF after the long-term follow-up[hazard ratio(HR):5.15×10−5(6.13×10−8−0.043);P<0.01].Receiver-operating characteristic(ROC)curve analysis demonstrated that the optimal cut-off value of the QFR immediately after PCI for predicting the long-term TVF was 0.925(area under the curve:0.886,95%confidence interval:0.834–0.938;sensitivity:83.40%,specificity:88.00;P<0.01).In addition,QFR≤0.925 post-PCI was strongly correlated with the TVF,including TV-MI and CD-TVR(P<0.01).Conclusion The QFR immediately after PCI showed a high predictive value of TVF after a long-term follow-up in ISR patients who underwent DCB angioplasty.A lower QFR immediately after PCI was associated with a worse TVF outcome. 展开更多
关键词 percutaneous coronary intervention in-stent restenosis target vessel failure quantitative flow ratio
下载PDF
Quantitative hepatitis B core antibody and quantitative hepatitis B surface antigen:Novel viral biomarkers for chronic hepatitis B management
9
作者 Wattana Leowattana Pathomthep Leowattana Tawithep Leowattana 《World Journal of Hepatology》 2024年第4期550-565,共16页
The management of hepatitis B virus(HBV)infection now involves regular and appropriate monitoring of viral activity,disease progression,and treatment response.Traditional HBV infection biomarkers are limited in their ... The management of hepatitis B virus(HBV)infection now involves regular and appropriate monitoring of viral activity,disease progression,and treatment response.Traditional HBV infection biomarkers are limited in their ability to predict clinical outcomes or therapeutic effectiveness.Quantitation of HBV core antibodies(qAnti-HBc)is a novel non-invasive biomarker that may help with a variety of diagnostic issues.It was shown to correlate strongly with infection stages,hepatic inflammation and fibrosis,chronic infection exacerbations,and the presence of occult infection.Furthermore,qAnti-HBc levels were shown to be predictive of spontaneous or treatment-induced HBeAg and HBsAg seroclearance,relapse after medication termination,re-infection following liver transplantation,and viral reactivation in the presence of immunosuppression.qAnti-HBc,on the other hand,cannot be relied on as a single diagnostic test to address all problems,and its diagnostic and prognostic potential may be greatly increased when paired with qHBsAg.Commercial qAnti-HBc diagnostic kits are currently not widely available.Because many methodologies are only semi-quantitative,comparing data from various studies and defining universal cut-off values remains difficult.This review focuses on the clinical utility of qAnti-HBc and qHBsAg in chronic hepatitis B management. 展开更多
关键词 quantitative hepatitis B core antibody quantitative hepatitis B surface antigen Chronic hepatitis B management Novels viral biomarkers
下载PDF
Quantitative lithium substitution of carboxyl hydrogens in polyacrylic acid binder enables robust SiO electrodes with durable lithium storage stability
10
作者 Weihua Wang Wenyi Li +7 位作者 Siyi Jing Huiping Yang Huiqun Wang Ling Huang Yuxiang Mao Xikun Pang Yudai Huang Li Zhang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第10期352-360,I0007,共10页
The design of advanced binders plays a critical role in stabilizing the cycling performance of large-volume-effect silicon monoxide(SiO)anodes.For the classic polyacrylic acid(PAA)binder,the self-association of-COOH g... The design of advanced binders plays a critical role in stabilizing the cycling performance of large-volume-effect silicon monoxide(SiO)anodes.For the classic polyacrylic acid(PAA)binder,the self-association of-COOH groups in PAA leads to the formation of intramolecular and intermolecular hydrogen bonds,greatly weakening the bonding force of the binder to SiO surface.However,strengthening the binder-material interaction from the perspective of binder molecular regulation poses a significant challenge.Herein,a modified PAA-Li_(x)(0.25≤x≤1)binder with prominent mechanical properties and adhesion strength is specifically synthesized for SiO anodes by quantitatively substituting the carboxylic hydrogen with lithium.The appropriate lithium substitution(x=0.25)not only effectively increases the number of hydrogen bonds between the PAA binder and SiO surface owing to charge repulsion effect between ions,but also guarantees moderate entanglement between PAA-Li_x molecular chains through the ion-dipole interaction.As such,the PAA-Li_(0.25)/SiO electrode exhibits exceptional mechanical properties and the lowest volume change,as well as the optimum cycling(1237.3 mA h g^(-1)after 100cycles at 0.1 C)and rate performance(1000.6 mA h g^(-1)at 1 C),significantly outperforming the electrode using pristine PAA binder.This work paves the way for quantitative regulation of binders at the molecular level. 展开更多
关键词 Polyacrylic acid binder SiO anode quantitative lithium substitution Charge repulsion effect Adhesion strength
下载PDF
Quantitative magnetic resonance imaging in prostate cancer:A review of current technology
11
作者 Ankita Dhiman Virendra Kumar Chandan Jyoti Das 《World Journal of Radiology》 2024年第10期497-511,共15页
Prostate cancer(PCa)imaging forms an important part of PCa clinical management.Magnetic resonance imaging is the modality of choice for prostate imaging.Most of the current imaging assessment is qualitative i.e.,based... Prostate cancer(PCa)imaging forms an important part of PCa clinical management.Magnetic resonance imaging is the modality of choice for prostate imaging.Most of the current imaging assessment is qualitative i.e.,based on visual inspection and thus subjected to inter-observer disagreement.Quantitative imaging is better than qualitative assessment as it is more objective,and standardized,thus improving interobserver agreement.Apart from detecting PCa,few quantitative parameters may have potential to predict disease aggressiveness,and thus can be used for prognosis and deciding the course of management.There are various magnetic resonance imaging-based quantitative parameters and few of them are already part of PIRADS v.2.1.However,there are many other parameters that are under study and need further validation by rigorous multicenter studies before recommending them for routine clinical practice.This review intends to discuss the existing quantitative methods,recent developments,and novel techniques in detail. 展开更多
关键词 Prostate cancer quantitative imaging Magnetic resonance imaging Apparent diffusion coefficient
下载PDF
Establishment of Fluorescence Quantitative RT-PCR Assay for Detection of Equine Arteritis Virus
12
作者 Wang Keke Liang Xinxin +7 位作者 Jiang Gangqiang Long Zhixin Hudusi Aierken Liu Zhiling Wang Yan Wu Xiaowei Xiao Yuanyuan Bai Meihua 《Animal Husbandry and Feed Science》 CAS 2024年第1期21-25,共5页
[Objective]The paper was to establish a fluorescence quantitative RT-PCR method for detection of equine arteritis virus(EAV).[Method]Primers and probes were developed for the EAV ORF7 gene sequence,and the reaction sy... [Objective]The paper was to establish a fluorescence quantitative RT-PCR method for detection of equine arteritis virus(EAV).[Method]Primers and probes were developed for the EAV ORF7 gene sequence,and the reaction system was optimized.Standard curves were established,leading to the initial development of the EAV fluorescence quantitative RT-PCR assay.The accuracy,specificity,and sensitivity of this method were subsequently evaluated.[Result]The EAV fluorescence quantitative RT-PCR assay demonstrated optimal performance at an annealing temperature of 61 C,with a final concentration of primer and probe set at 0.6μmol/L.The plasmid standard demonstrated a strong linear correlation with Ct values within the range of 1.6×10^(7)-1.6×10^(2)copies/μL.The equation of the standard curve was determined to be y=-2.68x+32.88,with an R^(2) value of 0.9927.Consequently,the EAV fluorescence quantitative RT-PCR assay was successfully established.The methodology employed was effective in detecting EAV,Theileria equi,equine herpesvirus-1(EHV-1),equine herpesvirus-4(EHV-4),and equine influenza virus(EIV).The findings indicated that the method was specifically capable of detecting EAV,while the other pathogens tested yielded negative results.The method demonstrated a high degree of specificity.It was employed to detect the standard plasmid cRNA synthesized through in vitro transcription following a 10-fold dilution.The results indicated that the minimum detection limit of the method was 1.6×10^(2) copies/μL,and it exhibited high sensitivity.The coefficient of variation,both within and between groups,was maintained at 1.8%,indicating good reproducibility.In this study,the fluorescence quantitative RT-PCR assay developed was utilized alongside the EAV fluorescence quantitative RT-PCR assay established by previous researchers to analyze a total of 234 clinical samples.Both methods yielded a positive detection rate of 14.1%,and the coincidence rate between the two techniques was found to be 100%.[Conclusion]The fluorescence quantitative RT-PCR assay developed in this study offers a novel approach and concept for the prevention and control of equine viral arteritis(EVA). 展开更多
关键词 Equine arteritis virus(EAV) ORF7 gene Fluorescence quantitative RT-PCR
下载PDF
Incorporating empirical knowledge into data-driven variable selection for quantitative analysis of coal ash content by laser-induced breakdown spectroscopy
13
作者 吕一涵 宋惟然 +1 位作者 侯宗余 王哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期148-156,共9页
Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can a... Laser-induced breakdown spectroscopy(LIBS)has become a widely used atomic spectroscopic technique for rapid coal analysis.However,the vast amount of spectral information in LIBS contains signal uncertainty,which can affect its quantification performance.In this work,we propose a hybrid variable selection method to improve the performance of LIBS quantification.Important variables are first identified using Pearson's correlation coefficient,mutual information,least absolute shrinkage and selection operator(LASSO)and random forest,and then filtered and combined with empirical variables related to fingerprint elements of coal ash content.Subsequently,these variables are fed into a partial least squares regression(PLSR).Additionally,in some models,certain variables unrelated to ash content are removed manually to study the impact of variable deselection on model performance.The proposed hybrid strategy was tested on three LIBS datasets for quantitative analysis of coal ash content and compared with the corresponding data-driven baseline method.It is significantly better than the variable selection only method based on empirical knowledge and in most cases outperforms the baseline method.The results showed that on all three datasets the hybrid strategy for variable selection combining empirical knowledge and data-driven algorithms achieved the lowest root mean square error of prediction(RMSEP)values of 1.605,3.478 and 1.647,respectively,which were significantly lower than those obtained from multiple linear regression using only 12 empirical variables,which are 1.959,3.718 and 2.181,respectively.The LASSO-PLSR model with empirical support and 20 selected variables exhibited a significantly improved performance after variable deselection,with RMSEP values dropping from 1.635,3.962 and 1.647 to 1.483,3.086 and 1.567,respectively.Such results demonstrate that using empirical knowledge as a support for datadriven variable selection can be a viable approach to improve the accuracy and reliability of LIBS quantification. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) coal ash content quantitative analysis variable selection empirical knowledge partial least squares regression(PLSR)
下载PDF
Establishment of High-sensitivity Rapid Fluorescence Quantitative Detection Method for Antibody against Peste des Petits Ruminants Virus
14
作者 Zhao LIU Bo LIU +3 位作者 Zhida LIN Hang SUN Yu SUN Xiaohui SONG 《Agricultural Biotechnology》 2024年第5期22-27,共6页
[Objectives]This study was conducted to establish a rapid quantitative method for detecting antibody against Peste des Petits Ruminants Virus(PPR V)in sheep serum.[Methods]Soluble N protein and NH fusion protein were ... [Objectives]This study was conducted to establish a rapid quantitative method for detecting antibody against Peste des Petits Ruminants Virus(PPR V)in sheep serum.[Methods]Soluble N protein and NH fusion protein were obtained in Escherichia coli prokaryotic expression system by optimizing codons and expression conditions of E.coli.Furthermore,based on the purified soluble N protein and NH fusion protein,a high-sensitivity fluorescence immunoassay kit for detecting the antibody against PPR V was established.[Results]The method could quickly and quantitatively detect PPR V antibody in sheep serum,with high sensitivity and specificity,without any cross reaction to other related sheep pathogens.The intra-batch and inter-batch coefficients of variation were less than 10%and 15%,respectively,and the method had good repeatability.Through detection on 292 clinical serum samples,it was compared with the French IDVET competitive ELISA kit,and the coincidence rate of the two methods reached 93.84%.Compared with the serum neutralization test,the detected titer value of the high-sensitivity rapid fluorescence quantitative detection method was basically consistent with the tilter value obtained by the neutralization test on the standard positive serum(provided by the WOAH Brucellosis Reference Laboratory of France).[Conclusions]This method can realize rapid quantitative detection of PPR V antibody on site,and has high practical value and popularization value. 展开更多
关键词 Peste des Petits Ruminants N protein NH fusion protein Soluble expression and purification Rapid quantitative detection
下载PDF
Quantitative Precipitation Estimation Using X-band Phased Array Weather Radar
15
作者 Shaoyu HOU Xuejiao CHEN +1 位作者 Chunnan SUO Xiangfeng HU 《Meteorological and Environmental Research》 2024年第4期29-31,共3页
This study utilized data from an X-band phased array weather radar and ground-based rain gauge observations to conduct a quantitative precipitation estimation(QPE)analysis of a heavy rainfall event in Xiong an New Are... This study utilized data from an X-band phased array weather radar and ground-based rain gauge observations to conduct a quantitative precipitation estimation(QPE)analysis of a heavy rainfall event in Xiong an New Area from 20:00 on August 21 to 07:00 on August 22,2022.The analysis applied the Z-R relationship method for radar-based precipitation estimation and evaluated the QPE algorithm s performance using scatter density plots and binary classification scores.The results indicated that the QPE algorithm accurately estimates light to moderate rainfall but significantly underestimates heavy rainfall.The study identified disparities in the predictive accuracy of the QPE algorithm across various precipitation intensity ranges,offering essential insights for the further refinement of QPE techniques. 展开更多
关键词 X-band phased array radar quantitative precipitation estimation
下载PDF
Macroinvertebrate Community Index (MCI) and Quantitative Macroinvertebrate Community Index (QMCI) Analysis: A Comparative Study between Le Afe and Mulivaifagatoloa Rivers, Upolu Island, Samoa
16
作者 S. Taupega-Satau P. Amosa +2 位作者 A. Leauga J. Nunufolau T. Veni Nun Yan 《Journal of Geoscience and Environment Protection》 2024年第8期149-167,共19页
The diversity of Samoa’s freshwater macroinvertebrates remains largely unexplored, with past studies focusing on specific species without comprehensive cataloguing. This research evaluated the health of Upolu Island... The diversity of Samoa’s freshwater macroinvertebrates remains largely unexplored, with past studies focusing on specific species without comprehensive cataloguing. This research evaluated the health of Upolu Island’s rural rivers through macroinvertebrate analysis, particularly in the Le Afe and Mulivaifagatoloa Rivers. Collaborating with Samoa’s Water Resources Division in the Ministry of Natural Resources and Environment (MNRE), three sites along each river were sampled, representing a gradient from pristine to anthropogenically impacted areas. A total of 2953 macroinvertebrates were collected and classified into five categories using established identification keys. The Macroinvertebrate Community Index (MCI) and Quantitative Macroinvertebrate Community Index (QMCI) were applied for analysis. The results showed no clear pattern of pollutant-sensitive species prevalence or decline in less disturbed rivers. High MCI scores with low QMCI values indicated numerous low-scoring species, while the opposite suggested a richness of high-scoring taxa. Although MCI and QMCI are tools for monitoring freshwater health, this study lays the groundwork for future research to categorize Samoan macroinvertebrates and assign tolerance scores based on their presence in varying river conditions. . 展开更多
关键词 MACROINVERTEBRATES Macroinvertebrate Community Index (MCI) quantitative Macroinvertebrate Community Index (QMCI) Water Quality
下载PDF
Prevalence and Study of the Clonality of Extended-Spectrum Beta-Lactamase-Producing Klebsiella pneumoniae Strains in Neonatology at the University Hospitals of Abidjan by the Pulsed Field Gel Electrophoresis and the Quantitative Antibiogram
17
作者 Valérie M’Bengue Gbonon Sidjè Arlette Afran +6 位作者 Stanislas Assohoun Egomli Djeda Franck Arnaud Gnahoré Aboubakar Sylla N’Golo David Coulibaly Nathalie Guessennd Assanvo Simon-Pierre N’Guetta Mireille Dosso 《Advances in Microbiology》 CAS 2024年第9期416-429,共14页
Background: ESBL-producing strains of Klebsiella pneumoniae, one of the main causes of nosocomial and hospital-acquired infections, are commonly associated with therapeutic impasses. Surveillance of these multidrug-re... Background: ESBL-producing strains of Klebsiella pneumoniae, one of the main causes of nosocomial and hospital-acquired infections, are commonly associated with therapeutic impasses. Surveillance of these multidrug-resistant pathogens is a crucial tool for controlling and preventing infections. This surveillance involves the use of appropriate molecular and phenotypic typing techniques. The choice of techniques is based on criteria such as discriminatory power, intra- and inter-laboratory reproducibility, epidemiological concordance, ease of use and cost. The aim of our study was to identify clusters of Extended-Spectrum Beta-Lactamase-producing Klebsiella pneumoniae (ESBL-K. pneumoniae) strains circulating in neonatology using quantitative antibiogram (QA) and Pulsed Field Gel Electrophoresis (PFGE). Materials and Methods: This cross-sectional study included 55 K. pneumoniae strains isolated from a total of 513 samples. These various samples are taken from newborns, healthcare personnel, and the environment. K. pneumoniae identification followed standard bacteriological procedures and was confirmed using the Vitek® 2 (bioMérieux). The detection of the ESBL phenotype was performed using the synergy test. QA and PFGE were used to identify clonal relationships between the various strains isolated. Concordance between these two methods was assessed by calculating Cohen’s KAPPA coefficient and Simpson’s diversity index. Results: Among the 55 K. pneumoniae strains included in this study, 58.2% (32/55) were found to be Extended-Spectrum Beta-Lactamase (ESBL) producers. Most of these strains were isolated from neonatal samples (blood samples and rectal swabs). The quantitative antibiogram method applied to 28 out of the 32 ESBL-producing strains revealed that the isolates were grouped into 5 clusters. Pulsed Field Gel Electrophoresis performed on a total of 16 ESBL-producing strains showed the existence of four profiles. A perfect concordance was observed between the two methods. Conclusion: The results of this study highlighted the existence of clonal strains of various origins within neonatology units. 展开更多
关键词 Resistance-Clone-Klebsiella pneumoniae-Pulsed Field Gel Electrophoresis-quantitative Antibiogram
下载PDF
Quantitative parameters in novel spectral computed tomography:Assessment of Ki-67 expression in patients with gastric adenocarcinoma 被引量:5
18
作者 Li-Ting Mao Wei-Cui Chen +6 位作者 Jian-Ye Lu Han-Liang Zhang Yong-Song Ye Yu Zhang Bo Liu Wei-Wei Deng Xian Liu 《World Journal of Gastroenterology》 SCIE CAS 2023年第10期1602-1613,共12页
BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the... BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the Ki-67 expression status are unclear.AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma(GC).METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma.Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt(kev),the slope of the spectral curve(λ_(HU)),iodine concentration(IC),normalized IC(nIC),effective atomic number(Z^(eff))and normalized Z^(eff)(nZ^(eff))in the arterial phase(AP)and venous phase(VP)were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma.Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status.Receiver operating characteristic(ROC)curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression,respectively.CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),and Z^(eff)-related parameters were significantly higher,but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status,and other analyzed parameters showed no statistical difference between the two groups.Spearman’s correlation analysis showed that CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),Z^(eff),and n Z^(eff) exhibited a negative correlation with Ki-67 status,whereas IC and nIC had positive correlation with Ki-67 status.The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status[area under the curve(AUC)=0.967;sensitivity 95.77%;specificity 91.89%)].Nevertheless,the differentiating capabilities of singlevariable model were moderate(AUC value 0.630-0.835).In addition,the nZ_(VP)^(eff) and nIC_(VP)(AUC 0.835 and 0.805)showed better performance than CT_(40 kev-VP),CT_(70 kev-VP) and CT_(100 kev-VP)(AUC 0.630,0.631 and 0.662)in discriminating the Ki-67 status.CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma.Z^(eff) and IC may be useful parameters for evaluating the Ki-67 expression. 展开更多
关键词 Spectral computer tomography quantitative parameters Gastric carcinoma Iodine concentration Effective atomic number Ki-67 expression
下载PDF
Deep learning assisted variational Hilbert quantitative phase imaging 被引量:5
19
作者 Zhuoshi Li Jiasong Sun +7 位作者 Yao Fan Yanbo Jin Qian Shen Maciej Trusiak Maria Cywińska Peng Gao Qian Chen Chao Zuo 《Opto-Electronic Science》 2023年第4期1-11,共11页
We propose a high-accuracy artifacts-free single-frame digital holographic phase demodulation scheme for relatively lowcarrier frequency holograms-deep learning assisted variational Hilbert quantitative phase imaging(... We propose a high-accuracy artifacts-free single-frame digital holographic phase demodulation scheme for relatively lowcarrier frequency holograms-deep learning assisted variational Hilbert quantitative phase imaging(DL-VHQPI).The method,incorporating a conventional deep neural network into a complete physical model utilizing the idea of residual compensation,reliably and robustly recovers the quantitative phase information of the test objects.It can significantly alleviate spectrum-overlapping-caused phase artifacts under the slightly off-axis digital holographic system.Compared to the conventional end-to-end networks(without a physical model),the proposed method can reduce the dataset size dramatically while maintaining the imaging quality and model generalization.The DL-VHQPI is quantitatively studied by numerical simulation.The live-cell experiment is designed to demonstrate the method's practicality in biological research.The proposed idea of the deep learning-assisted physical model might be extended to diverse computational imaging techniques. 展开更多
关键词 quantitative phase imaging digital holography deep learning high-throughput imaging
下载PDF
Evaluation of Reference Genes for Quantitative Real-Time PCR Analysis in Manila Clam Ruditapes philippinarum Under Hypoxic Stress 被引量:1
20
作者 JING Hao ZHOU Liqing +4 位作者 GONG Miao TU Kang LIU Zhihong WU Biao SUN Xiujun 《Journal of Ocean University of China》 SCIE CAS CSCD 2023年第4期1059-1067,共9页
Quantitative real-time PCR(qRT-PCR)has been widely used for gene expression analysis,and selection of reference genes is a key point to obtain accurate results.To find out optimal reference genes for qRT-PCR in Manila... Quantitative real-time PCR(qRT-PCR)has been widely used for gene expression analysis,and selection of reference genes is a key point to obtain accurate results.To find out optimal reference genes for qRT-PCR in Manila clam Ruditapes philippinarum in response to hypoxia,different tissues were used and compared to evaluate the stability of candidate reference genes under low oxygen stress(DO 0.5mgL^(−1) and DO 2.0mgL^(−1))and normal condition(DO 7.5mgL^(−1)).Seven candidate reference genes were selected to evaluate the stability of their expression levels.The reference genes were evaluated by Delta Ct,BestKeeper,NormFinder and geNorm,and then screened by RefFinder calculation.Under hypoxic stress of 0.5mgL^(−1),the most suitable reference gene for gill and hepatopancreas was RPL31,and the optimal reference genes for axe foot and adductor muscle were TUB and HIS,respectively.For hypoxic stress of 2.0mgL^(−1),the most stable reference gene for gill and hepatopancreas was RPL31,and the optimal reference genes for axe foot and adductor muscle were RPS23 and EF1A,respectively.At the normal condition,HIS and EF1A were identified as the optimal internal reference genes in gill and hepatopancreas respectively,and GFRP2 was the best internal reference gene for axe foot and adductor muscle.The present findings will provide important basis for the selection of reference genes for qRT-PCR analysis of gene expression level in bivalves under hypoxic stress,which might be helpful for the analysis of other molluscs too. 展开更多
关键词 CLAM reference gene HYPOXIA quantitative real-time PCR
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部